Young Seok Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Young Seok Lee has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Chang-Hun Lee
Department of Orthopaedic Surgery, Hanyang University College of Medicine, Seoul 04763, Republic of Korea
6 shared publications - Jinsik Park
Department of Orthopaedic Surgery, Hanyang University Guri Hospital, Guri 11923, Republic of Korea
3 shared publications - Jaewan Soh
Department of Orthopaedic Surgery, Hanyang University Guri Hospital, Hanyang University College of Medicine, Guri, Korea
2 shared publications - Wan-Sun Choi
Department of Orthopaedic Surgery, Ajou University School of Medicine, Suwon, Korea
2 shared publications - Bong Gun Lee
Department of Orthopedic Surgery, Hanyang University College of Medicine, Seoul, Korea
1 shared publication - Chang-Woo Woo
Department of Orthopaedic Surgery, Hanyang University Guri Hospital, 153 Gyeongchun-ro, Guri-si 11923, Republic of Korea
1 shared publication
Latest Publications
- Open Access
- 23 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (19) , 7372
Clinical Outcomes of Semi-Occlusive Dressing for Allen Type III Fingertip Injuries
Background/Objectives: Local flap coverage is still widely regarded as the treatment of choice for Allen type III fingertip injuries, and outcome data for conservative treatment remain limited. We evaluated the outcomes of semi-occlusive dressing for Allen type III fingertip injuries with bone exposure. Methods: This retrospective single-centre case series included 15 patients with 17 digits sustaining Allen type III fingertip injuries with exposed bone treated with semi-occlusive dressing. Allen type I or II injuries, isolated pulp defects, infection-related tissue loss and incomplete follow-up were excluded. Finger and thumb motion were assessed as total active motion and interphalangeal joint motion, respectively, as a percentage of the contralateral digit. Sensation was assessed using two-point discrimination, Semmes–Weinstein monofilament testing and a subjective contralateral percentage scale. Results: All 17 digits healed at a mean of 36 days (range 21–60), with a mean follow-up of 25 months (range 12–63). No additional surgery or major complications occurred. Nail deformity developed in four of the 17 digits (24%). Among the 14 fingers, total active motion averaged 95% of the contralateral side (range 80–100) and ten regained full motion; the three thumbs regained mean interphalangeal joint motion of 80% (range 50–100). The mean two-point discrimination was 6 mm, the median Semmes–Weinstein value was 2.83 and the mean subjective sensation was 84%. Conclusions: In Allen type III fingertip injuries with bone exposure, semi-occlusive dressing achieved reliable healing with satisfactory functional and sensory recovery and may be a useful alternative or adjunct to surgical reconstruction.
- 23 September 2026
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 15 (19) , 7372
Open AccessClinical Outcomes of Semi-Occlusive Dressing for Allen Type III Fingertip Injuries
Background/Objectives: Local flap coverage is still widely regarded as the treatment of choice for Allen type III fingertip injuries, and outcome data for conservative treatment remain limited. We evaluated the outcomes of semi-occlusive dressing for Allen type III fingertip injuries with bone exposure. Methods: This retrospective single-centre case series included 15 patients with 17 digits sustaining Allen type III fingertip injuries with exposed bone treated with semi-occlusive dressing. Allen type I or II injuries, isolated pulp defects, infection-related tissue loss and incomplete follow-up were excluded. Finger and thumb motion were assessed as total active motion and interphalangeal joint motion, respectively, as a percentage of the contralateral digit. Sensation was assessed using two-point discrimination, Semmes–Weinstein monofilament testing and a subjective contralateral percentage scale. Results: All 17 digits healed at a mean of 36 days (range 21–60), with a mean follow-up of 25 months (range 12–63). No additional surgery or major complications occurred. Nail deformity developed in four of the 17 digits (24%). Among the 14 fingers, total active motion averaged 95% of the contralateral side (range 80–100) and ten regained full motion; the three thumbs regained mean interphalangeal joint motion of 80% (range 50–100). The mean two-point discrimination was 6 mm, the median Semmes–Weinstein value was 2.83 and the mean subjective sensation was 84%. Conclusions: In Allen type III fingertip injuries with bone exposure, semi-occlusive dressing achieved reliable healing with satisfactory functional and sensory recovery and may be a useful alternative or adjunct to surgical reconstruction.
- Open Access
Combined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation
Background and Objectives: Coracoid process (CP) fractures combined with acromioclavicular (AC) joint dislocation are extremely rare, and evidence guiding optimal surgical management remains limited. This retrospective, single-center case series study evaluated clinical and radiologic outcomes after simultaneous fixation of both lesions using a clavicular hook plate and a coracoid screw. Materials and Methods: We retrospectively reviewed 15 consecutive patients with Ogawa type I CP fractures combined with AC joint dislocation who underwent clavicular hook plate and coracoid screw fixation between March 2019 and May 2024. Clinical outcomes at final follow-up included shoulder range of motion (ROM), visual analog scale (VAS) for pain, and the Constant score. Radiologic outcomes included CP union confirmed by computed tomography (CT) and residual AC joint subluxation. Results: The cohort comprised 13 men and 2 women with a mean age of 55.2 years, and the mean final follow-up was 40.2 months. At final follow-up, mean ROM was 168° for forward elevation, 161° for abduction, and 69° for external rotation at the side, with internal rotation to L1. The mean VAS score was 0.4 and the mean Constant score was 97. CT-confirmed union of the CP fracture was achieved in all patients, and no residual AC joint subluxation was observed. All patients returned to sports and activities of daily living. Conclusions: In this series, simultaneous fixation using a clavicular hook plate and a coracoid screw provided reliable stabilization for CP fractures with AC joint dislocation, achieving consistent CP union, restoration of AC joint alignment, and favorable clinical outcomes. However, given the retrospective, non-comparative study design, these findings should be interpreted with caution, and further comparative studies are warranted.
Open AccessCombined Clavicular Hook Plate and Coracoid Screw Fixation for Coracoid Process Fractures Associated with Acromioclavicular Joint Dislocation
Background and Objectives: Coracoid process (CP) fractures combined with acromioclavicular (AC) joint dislocation are extremely rare, and evidence guiding optimal surgical management remains limited. This retrospective, single-center case series study evaluated clinical and radiologic outcomes after simultaneous fixation of both lesions using a clavicular hook plate and a coracoid screw. Materials and Methods: We retrospectively reviewed 15 consecutive patients with Ogawa type I CP fractures combined with AC joint dislocation who underwent clavicular hook plate and coracoid screw fixation between March 2019 and May 2024. Clinical outcomes at final follow-up included shoulder range of motion (ROM), visual analog scale (VAS) for pain, and the Constant score. Radiologic outcomes included CP union confirmed by computed tomography (CT) and residual AC joint subluxation. Results: The cohort comprised 13 men and 2 women with a mean age of 55.2 years, and the mean final follow-up was 40.2 months. At final follow-up, mean ROM was 168° for forward elevation, 161° for abduction, and 69° for external rotation at the side, with internal rotation to L1. The mean VAS score was 0.4 and the mean Constant score was 97. CT-confirmed union of the CP fracture was achieved in all patients, and no residual AC joint subluxation was observed. All patients returned to sports and activities of daily living. Conclusions: In this series, simultaneous fixation using a clavicular hook plate and a coracoid screw provided reliable stabilization for CP fractures with AC joint dislocation, achieving consistent CP union, restoration of AC joint alignment, and favorable clinical outcomes. However, given the retrospective, non-comparative study design, these findings should be interpreted with caution, and further comparative studies are warranted.
- Open Access
- 1 December 2025
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 30 (4) , 179-187
Dual miniplate internal fixation for forearm diaphysis fractures: a clinical and biomechanical study
Purpose: Forearm diaphyseal fractures require anatomical reduction and stable internal fixation to restore pronation and supination function. Conventional 3.5-mm plates are effective but can be associated with hardware irritation and refracture after implant removal. Dual miniplate fixation using low-profile plates may offer a technically advantageous alternative. This study investigated the clinical outcomes and biomechanical performance of dual miniplate fixation for forearm shaft fractures.Methods: A retrospective review was conducted of 24 patients (29 fractures) treated with dual low-profile plates. Biomechanical testing was performed using synthetic radius models with three fixation constructs: a single 3.5-mm locking compression plate (LCP), dual 2.4-mm LCPs with non-locking screws, and dual 2.4-mm LCPs with mixed locking and non-locking screws. Outcomes included torsional stiffness, axial distraction, cantilever bending stiffness, and failure load.Results: All fractures achieved union, with a mean union time of 119.2 days. Two cases of delayed union and one metal failure were observed. Torsional stiffness and failure load were significantly greater in patients treated with a single 3.5-mm plate, while no significant differences were noted in axial distraction or anteroposterior bending stiffness.Conclusion: Despite lower biomechanical performance than the conventional 3.5-mm plate, dual miniplate fixation achieved satisfactory clinical outcomes with appropriate postoperative protocols. This technique may be a reliable alternative for selected fracture patterns if appropriate postoperative protocols are followed.
- 1 December 2025
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 30 (4) , 179-187
Open AccessDual miniplate internal fixation for forearm diaphysis fractures: a clinical and biomechanical study
Purpose: Forearm diaphyseal fractures require anatomical reduction and stable internal fixation to restore pronation and supination function. Conventional 3.5-mm plates are effective but can be associated with hardware irritation and refracture after implant removal. Dual miniplate fixation using low-profile plates may offer a technically advantageous alternative. This study investigated the clinical outcomes and biomechanical performance of dual miniplate fixation for forearm shaft fractures.Methods: A retrospective review was conducted of 24 patients (29 fractures) treated with dual low-profile plates. Biomechanical testing was performed using synthetic radius models with three fixation constructs: a single 3.5-mm locking compression plate (LCP), dual 2.4-mm LCPs with non-locking screws, and dual 2.4-mm LCPs with mixed locking and non-locking screws. Outcomes included torsional stiffness, axial distraction, cantilever bending stiffness, and failure load.Results: All fractures achieved union, with a mean union time of 119.2 days. Two cases of delayed union and one metal failure were observed. Torsional stiffness and failure load were significantly greater in patients treated with a single 3.5-mm plate, while no significant differences were noted in axial distraction or anteroposterior bending stiffness.Conclusion: Despite lower biomechanical performance than the conventional 3.5-mm plate, dual miniplate fixation achieved satisfactory clinical outcomes with appropriate postoperative protocols. This technique may be a reliable alternative for selected fracture patterns if appropriate postoperative protocols are followed.
- Open Access
- 1 January 2025
- Published by XMLink in Journal of Korean Medical Science
- Vol. 40 (32) , e191
Compression Rate Progression of Osteoporotic Vertebral Compression Fracture in Conservative Treatments
Soh J, et al. J Korean Med Sci. 2025 Jun;40:e191. https://doi.org/10.3346/jkms.2025.40.e191
- 1 January 2025
- Published by XMLink in Journal of Korean Medical Science
- Vol. 40 (32) , e191
Open AccessCompression Rate Progression of Osteoporotic Vertebral Compression Fracture in Conservative Treatments
Soh J, et al. J Korean Med Sci. 2025 Jun;40:e191. https://doi.org/10.3346/jkms.2025.40.e191
- Open Access
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 308-316
Comparative Analysis of Ultrasound and Surgical Findings in Anatomical Variations of de Quervain’s Disease
Lee YS, et al. Clin Orthop Surg. 2025 Apr;17(2):308-316. https://doi.org/10.4055/cios24127
- 1 January 2025
- Published by XMLink in Clinics in Orthopedic Surgery
- Vol. 17 (2) , 308-316
Open AccessComparative Analysis of Ultrasound and Surgical Findings in Anatomical Variations of de Quervain’s Disease
Lee YS, et al. Clin Orthop Surg. 2025 Apr;17(2):308-316. https://doi.org/10.4055/cios24127
- 25 January 2024
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 14 (03) , 214-225
Primary Arthroscopy-Assisted Foveal Repair of Triangular Fibrocartilage Complex Associated with Acute Distal Radius Fractures in Young Adults
Background In distal radius fractures (DRFs) occurring in nonosteoporotic age groups, it is known that triangular fibrocartilage complex (TFCC) injuries are frequently combined, with some experiencing persistent symptomatic instability. However, a gold standard treatment for these associated lesions has not yet been established. Purpose Our purpose was to investigate the outcomes of primary arthroscopy-assisted transosseous foveal repair of the TFCC associated with DRFs in young adults. Materials and Methods Fifteen patients aged <65 years who underwent open reduction and internal fixation for DRF and arthroscopy-assisted repair for foveal tear of the TFCC were included. Those patients were observed to have complete peripheral TFCC tear on preoperative wrist magnetic resonance imaging and intraoperative distal radioulnar joint (DRUJ) stability tests. This was confirmed with an arthroscopic examination. The transosseous technique was used to repair the TFCC after firm fixation of the DRF. The patients were immobilized with the long-arm splint in a neutral position for 2 weeks postoperatively and a removable short-arm splint was applied for another 2 weeks. DRUJ stability, grip strength, and patient-reported outcomes, including disabilities of the arm, shoulder, and hand (DASH) and Patient-Rated Wrist Evaluation scores, were evaluated as primary outcomes at 3, 6, and 12 months postoperatively. Results All patients showed a stable DRUJ throughout the follow-up period. The average grip strength ratio compared to the unaffected side was 69, 83, and 90% at 3, 6, and 12 months after surgery, respectively. The mean DASH score was 26.9, 18.4, and 6.7 at 3, 6, and 12 months postoperatively, respectively. Conclusion Primary arthroscopy-assisted transosseous foveal repair of the TFCC with internal fixation of the distal radius resulted in early recovery and good clinical outcomes in young patients. Level of Evidence Therapeutic, level IV.
- 25 January 2024
- Published by Georg Thieme Verlag KG in Journal of Wrist Surgery
- Vol. 14 (03) , 214-225
Primary Arthroscopy-Assisted Foveal Repair of Triangular Fibrocartilage Complex Associated with Acute Distal Radius Fractures in Young Adults
Background In distal radius fractures (DRFs) occurring in nonosteoporotic age groups, it is known that triangular fibrocartilage complex (TFCC) injuries are frequently combined, with some experiencing persistent symptomatic instability. However, a gold standard treatment for these associated lesions has not yet been established. Purpose Our purpose was to investigate the outcomes of primary arthroscopy-assisted transosseous foveal repair of the TFCC associated with DRFs in young adults. Materials and Methods Fifteen patients aged <65 years who underwent open reduction and internal fixation for DRF and arthroscopy-assisted repair for foveal tear of the TFCC were included. Those patients were observed to have complete peripheral TFCC tear on preoperative wrist magnetic resonance imaging and intraoperative distal radioulnar joint (DRUJ) stability tests. This was confirmed with an arthroscopic examination. The transosseous technique was used to repair the TFCC after firm fixation of the DRF. The patients were immobilized with the long-arm splint in a neutral position for 2 weeks postoperatively and a removable short-arm splint was applied for another 2 weeks. DRUJ stability, grip strength, and patient-reported outcomes, including disabilities of the arm, shoulder, and hand (DASH) and Patient-Rated Wrist Evaluation scores, were evaluated as primary outcomes at 3, 6, and 12 months postoperatively. Results All patients showed a stable DRUJ throughout the follow-up period. The average grip strength ratio compared to the unaffected side was 69, 83, and 90% at 3, 6, and 12 months after surgery, respectively. The mean DASH score was 26.9, 18.4, and 6.7 at 3, 6, and 12 months postoperatively, respectively. Conclusion Primary arthroscopy-assisted transosseous foveal repair of the TFCC with internal fixation of the distal radius resulted in early recovery and good clinical outcomes in young patients. Level of Evidence Therapeutic, level IV.
- Open Access
- 1 January 2024
- Published by XMLink in Journal of Korean Society of Spine Surgery
- Vol. 31 (4) , 133-151
How to Write Spine-Related Medical Certificates
소재완, et al. J Korean Soc Spine Surg. 2024 Dec;31(4):133-151. https://doi.org/10.4184/jkss.2024.31.4.133
- 1 January 2024
- Published by XMLink in Journal of Korean Society of Spine Surgery
- Vol. 31 (4) , 133-151
Open AccessHow to Write Spine-Related Medical Certificates
소재완, et al. J Korean Soc Spine Surg. 2024 Dec;31(4):133-151. https://doi.org/10.4184/jkss.2024.31.4.133
- Open Access
Usefulness of a drill stopper to prevent iatrogenic soft tissue injury in orthopedic surgery
- Open Access
- 1 June 2022
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 27 (2) , 125-133
Comparative finite element analysis of an osseointegration system in transradial amputation: a proposal of a new design for osseointegration
Purpose: Conventional osseointegration systems have been applied in patients requiring transhumeral or transfemoral amputation. However, the application of these systems to transradial amputation is limited by the small diameter of the radius and ulna. Our study compared the biomechanical stability of a novel osseointegration system with that of a conventional system used in transradial amputation through an analysis of finite element (FE) models.Methods: We established three-dimensional FE models of transradial amputations, which were osseointegrated with both the novel and conventional systems. External loads were applied to the FE models with compressive force and tensile force along the long axis, horizontal shear force, and vertical shear force. The maximum equivalent stress (MES) and the distribution of stress through the radius and ulna were evaluated.Results: The MES of the radius and ulna was higher in the conventional system when compressive, tensile, and vertical shear forces were applied. However, when a horizontal shear force was applied, the opposite result was found. The distribution of stress was more effective in the novel system.Conclusion: Three-dimensional FE modeling showed that the novel system enabled a lower stress level and a more even distribution of stress for osseointegration in transradial amputation.
- 1 June 2022
- Published by Korean Society for Surgery of the Hand in Archives of Hand and Microsurgery
- Vol. 27 (2) , 125-133
Open AccessComparative finite element analysis of an osseointegration system in transradial amputation: a proposal of a new design for osseointegration
Purpose: Conventional osseointegration systems have been applied in patients requiring transhumeral or transfemoral amputation. However, the application of these systems to transradial amputation is limited by the small diameter of the radius and ulna. Our study compared the biomechanical stability of a novel osseointegration system with that of a conventional system used in transradial amputation through an analysis of finite element (FE) models.Methods: We established three-dimensional FE models of transradial amputations, which were osseointegrated with both the novel and conventional systems. External loads were applied to the FE models with compressive force and tensile force along the long axis, horizontal shear force, and vertical shear force. The maximum equivalent stress (MES) and the distribution of stress through the radius and ulna were evaluated.Results: The MES of the radius and ulna was higher in the conventional system when compressive, tensile, and vertical shear forces were applied. However, when a horizontal shear force was applied, the opposite result was found. The distribution of stress was more effective in the novel system.Conclusion: Three-dimensional FE modeling showed that the novel system enabled a lower stress level and a more even distribution of stress for osseointegration in transradial amputation.
- Open Access
- 1 January 2021
- Published by XMLink in Journal of Korean Medical Science
- Vol. 36 (2) , e6
Process of Obtaining Social Consensus and 3-Year Functional Outcomes of the First Hand Allotransplantation in Korea
Woo SH, et al. J Korean Med Sci. 2020 Oct;36(2):e6. https://doi.org/10.3346/jkms.2021.36.e6
- 1 January 2021
- Published by XMLink in Journal of Korean Medical Science
- Vol. 36 (2) , e6
Open AccessProcess of Obtaining Social Consensus and 3-Year Functional Outcomes of the First Hand Allotransplantation in Korea
Woo SH, et al. J Korean Med Sci. 2020 Oct;36(2):e6. https://doi.org/10.3346/jkms.2021.36.e6