Christina Antke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Christina Antke has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Eduards Mamlins
Department of Nuclear Medicine, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University Duesseldorf, Duesseldorf, Germany
4 shared publications - Emil Novruzov
Department of Nuclear Medicine, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University Duesseldorf, Düsseldorf, Germany
3 shared publications - Frederik Lars Giesel
Department of Nuclear Medicine, University Hospital Düsseldorf, 40225 Düsseldorf, Germany
3 shared publications - Gerald Antoch
Department of Diagnostic and Interventional Radiology, Medical Faculty, University Dusseldorf, 40225 Dusseldorf, Germany
3 shared publications - Benedikt Michael Schaarschmidt
Institute of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany
2 shared publications - Dominik Schmitt
Department of Nuclear Medicine, Medical Faculty and University Hospital Duesseldorf, Heinrich-Heine-University Duesseldorf, 40225 Düsseldorf, Germany
2 shared publications
Latest Publications
- Open Access
- 13 August 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (16) , 2025
Predictive Power of Baseline [18F]FDG PET/CT for Adverse Events in DLBCL Patients Undergoing CAR-T Cell Therapy
Objectives: Evaluation of the predictive potential of pre-CAR-T [18F]FDG PET/CT in Diffuse Large B-Cell Lymphoma (DLBCL) patients concerning Cytokine Release Syndrome (CRS) and Immune Effector Cell-associated Neurotoxicity Syndrome (ICANS). Methods: Eighteen DLBCL patients (mean age: 60 ± 12 years) who underwent pre-therapeutic [18F]FDG-PET/CT and CAR-T cell therapy were retrospectively included. Median follow-up time was ten months (IQR6-16) after CAR-T cell infusion. Age, sex, serum lactate dehydrogenase (LDH), interleukin-6 (IL-6), C-reactive protein (CRP), and modified Endothelial Activation and Stress Index (mEASIX) were obtained. Potential occurrence of CRS/ICANS and the SUVmax were evaluated. Pearson and Spearman correlations, group comparisons (Mann–Whitney U-test) and the odds ratio (OR) were calculated. P values below 0.05 were defined as statistically significant and 95%-confidence intervals (CI) were calculated. Results: Pre-therapeutic SUVmax correlated positively with LDH (r = 0.5; p = 0.02), with the grade of CRS (r = 0.5; p = 0.03) and with the grade of ICANS (r = 0.6; p = 0.01). Appearance of ICANS was significantly correlated with pre-therapeutic SUVmax (p = 0.03; U = 7.0; Z = −2.2). Using ROC analysis and Youden’s index, an SUVmax threshold of 17 (AUC: 0.865; p < 0.01) was defined. Patients exceeding a pre-therapeutic SUVmax of 17 had a significantly higher risk of CRS grade > 1 (OR = 22; CI 2, 314; p = 0.03) and ICANS grade > 1 (OR = 18; CI 1, 271; p = 0.04). Conclusions: Pre-therapeutic SUVmax may be a useful marker for identifying DLBCL patients at risk for CRS and ICANS.
- 13 August 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (16) , 2025
Open AccessPredictive Power of Baseline [18F]FDG PET/CT for Adverse Events in DLBCL Patients Undergoing CAR-T Cell Therapy
Objectives: Evaluation of the predictive potential of pre-CAR-T [18F]FDG PET/CT in Diffuse Large B-Cell Lymphoma (DLBCL) patients concerning Cytokine Release Syndrome (CRS) and Immune Effector Cell-associated Neurotoxicity Syndrome (ICANS). Methods: Eighteen DLBCL patients (mean age: 60 ± 12 years) who underwent pre-therapeutic [18F]FDG-PET/CT and CAR-T cell therapy were retrospectively included. Median follow-up time was ten months (IQR6-16) after CAR-T cell infusion. Age, sex, serum lactate dehydrogenase (LDH), interleukin-6 (IL-6), C-reactive protein (CRP), and modified Endothelial Activation and Stress Index (mEASIX) were obtained. Potential occurrence of CRS/ICANS and the SUVmax were evaluated. Pearson and Spearman correlations, group comparisons (Mann–Whitney U-test) and the odds ratio (OR) were calculated. P values below 0.05 were defined as statistically significant and 95%-confidence intervals (CI) were calculated. Results: Pre-therapeutic SUVmax correlated positively with LDH (r = 0.5; p = 0.02), with the grade of CRS (r = 0.5; p = 0.03) and with the grade of ICANS (r = 0.6; p = 0.01). Appearance of ICANS was significantly correlated with pre-therapeutic SUVmax (p = 0.03; U = 7.0; Z = −2.2). Using ROC analysis and Youden’s index, an SUVmax threshold of 17 (AUC: 0.865; p < 0.01) was defined. Patients exceeding a pre-therapeutic SUVmax of 17 had a significantly higher risk of CRS grade > 1 (OR = 22; CI 2, 314; p = 0.03) and ICANS grade > 1 (OR = 18; CI 1, 271; p = 0.04). Conclusions: Pre-therapeutic SUVmax may be a useful marker for identifying DLBCL patients at risk for CRS and ICANS.
- Open Access
Head-to-Head Intra-Individual Comparison of Biodistribution and Tumor Uptake of [18F]FAPI-74 with [18F]FDG in Patients with PDAC: A Prospective Exploratory Study
Background: Radiolabeled fibroblast activation protein (FAP) ligands, a novel class of tracers for PET/CT imaging, have demonstrated very promising results in various oncological, as well as in some benign, diseases with long-term potential to supplant the current pan-cancer agent [18F]FDG in some cancer types. Pancreatic ductal carcinoma (PDAC) belongs to the group of epithelial malignancies with a strong so-called “desmoplastic reaction”, leading to a prominent tumor stroma with cancer-associated fibroblasts that exhibit a marked overexpression of fibroblast activation protein (FAP). The first clinical experiences in PDAC with 68Ga-labeled FAP ligands suggested superior sensitivity to [18F]FDG. However, there is limited data with 18F-labeled FAP derivatives, i.e. [18F]FAPI-74, yet prospective single- and multicenter trials are already ongoing. In this proof-of-concept study, we sought to evaluate the biodistribution, tumor uptake, and lesion detectability in patients with PDAC using [18F]FAPI-74 PET/CT as compared to [18F]FDG PET/CT scans for staging. Methods: This study includes 7 patients (median age 69) who underwent both [18F]FDG PET/CT with contrast-enhancement and [18F]FAPI-74 PET with low-dose CT for primary staging (n = 3) and therapy response control after neoadjuvant (n = 1) or re-staging after palliative therapy (n = 3). The mean interval between PET scans was 11 ± 4 days (range 1–15 days). The [18F]FDG and [18F]FAPI-74 PET/CT scans were acquired at 64 ± 4.1 min (range 61–91 min) and 66.4 ± 6.3 min (range 60–76 min), respectively, after administration of 200 ± 94 MBq (range 79–318 MBq) and 235 ± 88 MBq (range 90–321 MBq), respectively. Quantification of tracer uptake was determined with SUVmax and SUVmean. Furthermore, the tumor-to-background ratio (TBR) was derived by dividing the SUVmax of tumor lesions by the SUVmax of adipose tissue, skeletal muscle, and blood pool. Results: Overall, 32 lesions were detected in 7 patients including primary (n = 7), lung (n = 7), bone (n = 3), lymph node (n = 13), and peritoneal metastases (n = 2). [18F]FAPI-74 detected 22% more lesions compared with [18F]FDG with a better TBR and visual lesion delineation. In one patient the primary lesion could be detected unequivocally with [18F]FAPI-74 but was missed by [18F]FDG imaging. Altogether, most of the lesions demonstrated markedly elevated uptake of [18F]FAPI-74 with a simultaneous lower uptake in the background, providing a very high visual contrast. Conclusion: To the best of our knowledge, this is the first, prospective, intra-individual investigation comparing [18F]FAPI-74 with [18F]FDG imaging in PDAC with encouraging results. These pivotalresults supporta larger, multicentric, prospective study to determine the value of [18F]FAPI-74 in detecting and staging PDAC in comparison with current standard of care imaging.
Open AccessHead-to-Head Intra-Individual Comparison of Biodistribution and Tumor Uptake of [18F]FAPI-74 with [18F]FDG in Patients with PDAC: A Prospective Exploratory Study
Background: Radiolabeled fibroblast activation protein (FAP) ligands, a novel class of tracers for PET/CT imaging, have demonstrated very promising results in various oncological, as well as in some benign, diseases with long-term potential to supplant the current pan-cancer agent [18F]FDG in some cancer types. Pancreatic ductal carcinoma (PDAC) belongs to the group of epithelial malignancies with a strong so-called “desmoplastic reaction”, leading to a prominent tumor stroma with cancer-associated fibroblasts that exhibit a marked overexpression of fibroblast activation protein (FAP). The first clinical experiences in PDAC with 68Ga-labeled FAP ligands suggested superior sensitivity to [18F]FDG. However, there is limited data with 18F-labeled FAP derivatives, i.e. [18F]FAPI-74, yet prospective single- and multicenter trials are already ongoing. In this proof-of-concept study, we sought to evaluate the biodistribution, tumor uptake, and lesion detectability in patients with PDAC using [18F]FAPI-74 PET/CT as compared to [18F]FDG PET/CT scans for staging. Methods: This study includes 7 patients (median age 69) who underwent both [18F]FDG PET/CT with contrast-enhancement and [18F]FAPI-74 PET with low-dose CT for primary staging (n = 3) and therapy response control after neoadjuvant (n = 1) or re-staging after palliative therapy (n = 3). The mean interval between PET scans was 11 ± 4 days (range 1–15 days). The [18F]FDG and [18F]FAPI-74 PET/CT scans were acquired at 64 ± 4.1 min (range 61–91 min) and 66.4 ± 6.3 min (range 60–76 min), respectively, after administration of 200 ± 94 MBq (range 79–318 MBq) and 235 ± 88 MBq (range 90–321 MBq), respectively. Quantification of tracer uptake was determined with SUVmax and SUVmean. Furthermore, the tumor-to-background ratio (TBR) was derived by dividing the SUVmax of tumor lesions by the SUVmax of adipose tissue, skeletal muscle, and blood pool. Results: Overall, 32 lesions were detected in 7 patients including primary (n = 7), lung (n = 7), bone (n = 3), lymph node (n = 13), and peritoneal metastases (n = 2). [18F]FAPI-74 detected 22% more lesions compared with [18F]FDG with a better TBR and visual lesion delineation. In one patient the primary lesion could be detected unequivocally with [18F]FAPI-74 but was missed by [18F]FDG imaging. Altogether, most of the lesions demonstrated markedly elevated uptake of [18F]FAPI-74 with a simultaneous lower uptake in the background, providing a very high visual contrast. Conclusion: To the best of our knowledge, this is the first, prospective, intra-individual investigation comparing [18F]FAPI-74 with [18F]FDG imaging in PDAC with encouraging results. These pivotalresults supporta larger, multicentric, prospective study to determine the value of [18F]FAPI-74 in detecting and staging PDAC in comparison with current standard of care imaging.
- Open Access
Intra-Individual Comparison of Physiologic [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 Uptake in Ganglia in Patients with Prostate Cancer: A Retrospective, Monocentric Analysis
Background: Several studies indicate, particularly in the case of [18F]PSMA-1007, a relatively high rate of detection of ganglia in PSMA PET imaging. Ganglia are an integral part of the sympathetic portion of the autonomous nervous system. To date, no studies have directly compared [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 ganglionic uptake intra-individually and analyzed the underlying molecular and physical mechanisms of different detection rates. With this monocentric retrospective study, we sought to evaluate the intra-individual physiological ganglion uptake of these different PSMA ligands in evidence-based imaging for prostate cancer. Methods: Our cohort consists of 19 male patients (median age 72 ± 9 with a range of 56–85) with biochemical recurrence of prostate cancer who underwent both [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 PET/CT in our clinic on the same scanner per standard care between March 2015 and March 2022. Tracer uptake was quantified according to maximum standardized uptake value (SUVmax) for both [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 PET/CT scans. Ganglia-to-background ratios (GBRs) were determined to quantify the image contrast through dividing the SUVmax of the ganglia by the background value (SUVmax of blood pool in the descending aorta, fatty tissue, and skeletal muscle in gluteal region). We used descriptive analyses for demographics and tumor characteristics and performed two-way repeated-measures ANOVA (analysis of variance) for SUV metrics including GBR measurements. Results: In total, we examined 101 ganglia with [18F]PSMA-1007 scanning, localized mostly in pairs as stellate, coeliac, and sacral, of which 76 were also detected with [68Ga]Ga-PSMA-11 PET/CT scanning. There was no statistically significant difference in PSMA uptake in terms of SUVmax between [18F]PSMA-1007 and [68Ga]Ga-PSMA-11 (p value: 0.052). In contrast, the comparison of GBRs revealed a higher detectability rate of ganglia with [18F]PSMA-1007 imaging (p < 0.001). Furthermore, a separate comparison of ganglia with respect to their anatomical location also demonstrated statistically significant differences both within and between [18F]PSMA-1007 and [68Ga]Ga-PSMA-11 PET/CT scans. Conclusion: Given the impression of more accentuated [18F]PSMA-1007 uptake in ganglia compared with 68Ga-labelled counterparts, our study demonstrated that the better detectability of ganglia is not due to more intense [18F]PSMA-1007 uptake by these small structures but to much more favorable physical properties of the radionuclide 18F. The most relevant limitations of our study are its retrospective design and the small patient cohort.
Open AccessIntra-Individual Comparison of Physiologic [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 Uptake in Ganglia in Patients with Prostate Cancer: A Retrospective, Monocentric Analysis
Background: Several studies indicate, particularly in the case of [18F]PSMA-1007, a relatively high rate of detection of ganglia in PSMA PET imaging. Ganglia are an integral part of the sympathetic portion of the autonomous nervous system. To date, no studies have directly compared [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 ganglionic uptake intra-individually and analyzed the underlying molecular and physical mechanisms of different detection rates. With this monocentric retrospective study, we sought to evaluate the intra-individual physiological ganglion uptake of these different PSMA ligands in evidence-based imaging for prostate cancer. Methods: Our cohort consists of 19 male patients (median age 72 ± 9 with a range of 56–85) with biochemical recurrence of prostate cancer who underwent both [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 PET/CT in our clinic on the same scanner per standard care between March 2015 and March 2022. Tracer uptake was quantified according to maximum standardized uptake value (SUVmax) for both [68Ga]Ga-PSMA-11 and [18F]PSMA-1007 PET/CT scans. Ganglia-to-background ratios (GBRs) were determined to quantify the image contrast through dividing the SUVmax of the ganglia by the background value (SUVmax of blood pool in the descending aorta, fatty tissue, and skeletal muscle in gluteal region). We used descriptive analyses for demographics and tumor characteristics and performed two-way repeated-measures ANOVA (analysis of variance) for SUV metrics including GBR measurements. Results: In total, we examined 101 ganglia with [18F]PSMA-1007 scanning, localized mostly in pairs as stellate, coeliac, and sacral, of which 76 were also detected with [68Ga]Ga-PSMA-11 PET/CT scanning. There was no statistically significant difference in PSMA uptake in terms of SUVmax between [18F]PSMA-1007 and [68Ga]Ga-PSMA-11 (p value: 0.052). In contrast, the comparison of GBRs revealed a higher detectability rate of ganglia with [18F]PSMA-1007 imaging (p < 0.001). Furthermore, a separate comparison of ganglia with respect to their anatomical location also demonstrated statistically significant differences both within and between [18F]PSMA-1007 and [68Ga]Ga-PSMA-11 PET/CT scans. Conclusion: Given the impression of more accentuated [18F]PSMA-1007 uptake in ganglia compared with 68Ga-labelled counterparts, our study demonstrated that the better detectability of ganglia is not due to more intense [18F]PSMA-1007 uptake by these small structures but to much more favorable physical properties of the radionuclide 18F. The most relevant limitations of our study are its retrospective design and the small patient cohort.
- Open Access
- 1 February 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 375
Impact of Different Metal Artifact Reduction Techniques on Attenuation Correction of Normal Organs in 18F-FDG-PET/CT
Purpose: To evaluate the impact of different metal artifact reduction algorithms on Hounsfield units (HU) and the standardized uptake value (SUV) in normal organs in patients with different metal implants. Methods: This study prospectively included 66 patients (mean age of 66.02 ± 13.1 years) with 87 different metal implants. CT image reconstructions were performed using weighted filtered back projection (WFBP) as the standard method, metal artifact reduction in image space (MARIS), and an iterative metal artifacts reduction (iMAR) algorithm for large implants. These datasets were used for PET attenuation correction. HU and SUV measurements were performed in nine predefined anatomical locations: liver, lower lung lobes, descending aorta, thoracic vertebral body, autochthonous back muscles, pectoral muscles, and internal jugular vein. Differences between HU and SUV measurements were compared using paired t-tests. The significance level was determined as p = 0.017 using Bonferroni correction. Results: No significant differences were observed between reconstructed images using iMAR and WFBP concerning HU and SUV measurements in liver (HU: p = 0.055; SUVmax: p = 0.586), lung (HU: p = 0.276; SUVmax: p = 1.0 for the right side and HU: p = 0.630; SUVmax: p = 0.109 for the left side), descending aorta (HU: p = 0.333; SUVmax: p = 0.083), thoracic vertebral body (HU: p = 0.725; SUVmax: p = 0.392), autochthonous back muscles (HU: p = 0.281; SUVmax: p = 0.839), pectoral muscles (HU: p = 0.481; SUVmax: p = 0.277 for the right side and HU: p = 0.313; SUVmax: p = 0.859 for the left side), or the internal jugular vein (HU: p = 0.343; SUVmax: p = 0.194). Conclusion: Metal artifact reduction algorithms such as iMAR do not alter the data information of normal organs not affected by artifacts.
- 1 February 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (2) , 375
Open AccessImpact of Different Metal Artifact Reduction Techniques on Attenuation Correction of Normal Organs in 18F-FDG-PET/CT
Purpose: To evaluate the impact of different metal artifact reduction algorithms on Hounsfield units (HU) and the standardized uptake value (SUV) in normal organs in patients with different metal implants. Methods: This study prospectively included 66 patients (mean age of 66.02 ± 13.1 years) with 87 different metal implants. CT image reconstructions were performed using weighted filtered back projection (WFBP) as the standard method, metal artifact reduction in image space (MARIS), and an iterative metal artifacts reduction (iMAR) algorithm for large implants. These datasets were used for PET attenuation correction. HU and SUV measurements were performed in nine predefined anatomical locations: liver, lower lung lobes, descending aorta, thoracic vertebral body, autochthonous back muscles, pectoral muscles, and internal jugular vein. Differences between HU and SUV measurements were compared using paired t-tests. The significance level was determined as p = 0.017 using Bonferroni correction. Results: No significant differences were observed between reconstructed images using iMAR and WFBP concerning HU and SUV measurements in liver (HU: p = 0.055; SUVmax: p = 0.586), lung (HU: p = 0.276; SUVmax: p = 1.0 for the right side and HU: p = 0.630; SUVmax: p = 0.109 for the left side), descending aorta (HU: p = 0.333; SUVmax: p = 0.083), thoracic vertebral body (HU: p = 0.725; SUVmax: p = 0.392), autochthonous back muscles (HU: p = 0.281; SUVmax: p = 0.839), pectoral muscles (HU: p = 0.481; SUVmax: p = 0.277 for the right side and HU: p = 0.313; SUVmax: p = 0.859 for the left side), or the internal jugular vein (HU: p = 0.343; SUVmax: p = 0.194). Conclusion: Metal artifact reduction algorithms such as iMAR do not alter the data information of normal organs not affected by artifacts.
- 1 November 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1105) , 20190069
Impact of different metal artifact reduction techniques on attenuation correction in 18F-FDG PET/CT examinations
Objective: To evaluate the impact of different metal artifact reduction (MAR) algorithms on Hounsfield unit (HU) and standardized uptake values (SUV) in a phantom setting and verify these results in patients with metallic implants undergoing oncological PET/CT examinations. Methods and materials: In this prospective study, PET-CT examinations of 28 oncological patients (14 female, 14 male, mean age 69.5 ± 15.2y) with 38 different metal implants were included. CT datasets were reconstructed using standard weighted filtered back projection (WFBP) without MAR, MAR in image space (MARIS) and iterative MAR (iMAR, hip algorithm). The three datasets were used for PET attenuation correction. SUV and HU measurements were performed at the site of the most prominent bright and dark band artifacts. Differences between HU and SUV values across the different reconstructions were compared using paired t-tests. Bonferroni correction was used to prevent alpha-error accumulation (p < 0.017). Results: For bright band artifacts, MARIS led to a non-significant mean decrease of 12.0% (345 ± 315 HU) in comparison with WFBP (391 ± 293 HU), whereas iMAR led to a significant decrease of 68.3% (125 ± 185 HU, p < 0.017). For SUVmean, MARIS showed no significant effect in comparison with WFBP (WFBP: 0.99 ± 0.40, MARIS: 0.96 ± 0.39), while iMAR led to a significant decrease of 11.1% (0.88 ± 0.35, p < 0.017). Similar results were observed for dark band artifacts. Conclusion: iMAR significantly reduces artifacts caused by metal implants in CT and thus leads to a significant change of SUV measurements in bright and dark band artifacts compared with WFBP and MARIS, thus probably improving PET quantification. Advances in knowledge: The present work indicates that MAR algorithms such as iMAR algorithm in integrated PET/CT scanners are useful to improve CT image quality as well as PET quantification in the evaluation of tracer uptake adjacent to large metal implants. A detailed analysis of oncological patients with various large metal implants using different MAR algorithms in PET/CT has not been conducted yet.
- 1 November 2019
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 93 (1105) , 20190069
Impact of different metal artifact reduction techniques on attenuation correction in 18F-FDG PET/CT examinations
Objective: To evaluate the impact of different metal artifact reduction (MAR) algorithms on Hounsfield unit (HU) and standardized uptake values (SUV) in a phantom setting and verify these results in patients with metallic implants undergoing oncological PET/CT examinations. Methods and materials: In this prospective study, PET-CT examinations of 28 oncological patients (14 female, 14 male, mean age 69.5 ± 15.2y) with 38 different metal implants were included. CT datasets were reconstructed using standard weighted filtered back projection (WFBP) without MAR, MAR in image space (MARIS) and iterative MAR (iMAR, hip algorithm). The three datasets were used for PET attenuation correction. SUV and HU measurements were performed at the site of the most prominent bright and dark band artifacts. Differences between HU and SUV values across the different reconstructions were compared using paired t-tests. Bonferroni correction was used to prevent alpha-error accumulation (p < 0.017). Results: For bright band artifacts, MARIS led to a non-significant mean decrease of 12.0% (345 ± 315 HU) in comparison with WFBP (391 ± 293 HU), whereas iMAR led to a significant decrease of 68.3% (125 ± 185 HU, p < 0.017). For SUVmean, MARIS showed no significant effect in comparison with WFBP (WFBP: 0.99 ± 0.40, MARIS: 0.96 ± 0.39), while iMAR led to a significant decrease of 11.1% (0.88 ± 0.35, p < 0.017). Similar results were observed for dark band artifacts. Conclusion: iMAR significantly reduces artifacts caused by metal implants in CT and thus leads to a significant change of SUV measurements in bright and dark band artifacts compared with WFBP and MARIS, thus probably improving PET quantification. Advances in knowledge: The present work indicates that MAR algorithms such as iMAR algorithm in integrated PET/CT scanners are useful to improve CT image quality as well as PET quantification in the evaluation of tracer uptake adjacent to large metal implants. A detailed analysis of oncological patients with various large metal implants using different MAR algorithms in PET/CT has not been conducted yet.