Claudia Rosa Do Espirito Santo Nóbrega
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Claudia Rosa Do Espirito Santo Nóbrega has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Fátima A.M. Lino
2 shared publicationsJanayna Rocha Silva
Energy Department, Faculty of Mechanical Engineering, State University of Campinas, Campinas, Brazil
2 shared publicationsKamal A. R. Ismail
Energy Department, Faculty of Mechanical Engineering, State University of Campinas, Campinas, Brazil
2 shared publicationsKamal A.R. Ismail
UNICAMP: Universidade Estadual de Campinas
2 shared publications- Kamal Abdel Radi Ismail
Faculty of Mechanical Engineering, Department of Energy, State University of Campinas, Mendeleiev Street, 200, Cidade Universitaria “Zeferino Vaz”, Barão Geraldo, Campinas 130.83-860, SP, Brazil
2 shared publications Fatima A. M. Lino
Energy Department, Faculty of Mechanical Engineering, State University of Campinas, Campinas, Brazil
1 shared publication
Latest Publications
- 19 January 2024
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 46 (2) , 1-20
Thermal evaluation of geometrical innovations in concentric and eccentric evacuated single and double solar collectors
- 19 January 2024
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 46 (2) , 1-20
Thermal evaluation of geometrical innovations in concentric and eccentric evacuated single and double solar collectors
- Open Access
- 21 September 2023
- Published by Springer Nature in Research Square
Thermal evaluation of geometrical innovations in concentric and eccentric evacuated single and double solar collectors
In this study, an experimental and numerical investigation of eight geometrical configurations of evacuated tube solar collectors was conducted. The configurations were tested simultaneously in outdoor installation under the same test conditions. The parameters such as collector eccentricity, solar concentration, vacuum, collector absorber, and cover tube materials were investigated. The numerical model developed in MATLAB was validated with experimental results. The results show that the eccentricity and the absorptivity of the material of the absorber are the parameters that have the highest influence on the collector performance. The use of reflective film in the eccentric solar collectors’ configurations can increase efficiency by 33%. The vacuum presented an efficiency increase variation between 1% and 4% in the eccentric tube collectors. For the concentric collectors configurations, the use of the vacuum between the tubes can reach an increase of 9% in its performance. The eccentricity of the collector using reflective film and vacuum allows an effective solar concentration in the collector absorber presenting a 26% higher efficiency when compared with the concentric collector.
- 21 September 2023
- Published by Springer Nature in Research Square
Open AccessThermal evaluation of geometrical innovations in concentric and eccentric evacuated single and double solar collectors
In this study, an experimental and numerical investigation of eight geometrical configurations of evacuated tube solar collectors was conducted. The configurations were tested simultaneously in outdoor installation under the same test conditions. The parameters such as collector eccentricity, solar concentration, vacuum, collector absorber, and cover tube materials were investigated. The numerical model developed in MATLAB was validated with experimental results. The results show that the eccentricity and the absorptivity of the material of the absorber are the parameters that have the highest influence on the collector performance. The use of reflective film in the eccentric solar collectors’ configurations can increase efficiency by 33%. The vacuum presented an efficiency increase variation between 1% and 4% in the eccentric tube collectors. For the concentric collectors configurations, the use of the vacuum between the tubes can reach an increase of 9% in its performance. The eccentricity of the collector using reflective film and vacuum allows an effective solar concentration in the collector absorber presenting a 26% higher efficiency when compared with the concentric collector.
- 14 July 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (12) , 12355-12372
Crushed Rubber from Used Tires for Thermal Insulation of Walls and Flat Roofs: Modeling, Validation and Comparison with Conventional Technology
- 14 July 2021
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 46 (12) , 12355-12372
Crushed Rubber from Used Tires for Thermal Insulation of Walls and Flat Roofs: Modeling, Validation and Comparison with Conventional Technology
- 2 January 2021
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 43 (1) , 1-14
Thermal performance of bare and finned tubes submersed in nano-PCM mixture
- 2 January 2021
- Published by Springer Nature in Journal of the Brazilian Society of Mechanical Sciences and Engineering
- Vol. 43 (1) , 1-14
Thermal performance of bare and finned tubes submersed in nano-PCM mixture
- 1 December 2019
- Published by Elsevier in Journal of Energy Storage
- Vol. 26
Correlations for predicting the performance of axial finned tubes submersed in PCM
- 1 December 2019
- Published by Elsevier in Journal of Energy Storage
- Vol. 26
Correlations for predicting the performance of axial finned tubes submersed in PCM
- 1 March 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 99, 251-263
Enhancement of ice formation around vertical finned tubes for cold storage applications
- 1 March 2019
- Published by Elsevier in International Journal of Refrigeration
- Vol. 99, 251-263
Enhancement of ice formation around vertical finned tubes for cold storage applications