FBFabrício Reichert Barin

Fabrício Reichert Barin

*This is an algorithmically generated author record based on publicly available information.

Fabrício Reichert Barin has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effects of amino acid supplementation on muscle mass, muscle performance and functional capacity in subjects undergoing total knee arthroplasty: a systematic review of randomized clinical trials

    by Jose Humberto de Souza Borges, Paulo Lobo Junior, Felipe Fagundes de Brito, Heitor Paes Rezende, Marcos Vinicius de Souza Silva, Marcio Oliveira, Fabrício Reichert Barin

    The aim of the present study was to summarize the effectiveness of amino acid supplementation on muscle strength, muscle volume, and functional capacity in patients undergoing total knee arthroplasty. For this, in November 2022, a search was carried out in the PubMed, Cochrane Library, and EMBASE databases, identifying a total of 2182 documents, of which only 4 were included in the present review. The included studies had 148 participants (47 men and 101 women), with a minimum age of 53 and a maximum of 92 years, and supplementation times of 13 to 30 days (1 to 3 times a day). For the results, in relation to muscle performance, when comparing the control and experimental groups, greater muscle atrophy was observed in the pre- and post-moments of the control group, in relation to the experimental group. In addition, studies suggest a good tendency for muscle mass gain, and improvement in the functional capacities of patients who used supplementation. Therefore, the use of amino acids after TKA surgery reduces muscle atrophy, which preserves muscle mass and leads to better performance in tests of strength and functional capacity, when compared to the use of a placebo.


  • Open Access

    Effects of Home-Based Electrical Stimulation on Plasma Cytokines Profile, Redox Biomarkers, and Metalloproteinases in the Heart Failure with Reduced Ejection Fraction: A Randomized Trial

    by Marianne Lucena da Silva, Ivo Vieira de Sousa Neto, Alexandra C. G. B. de Lima, Fabrício Barin, Otávio de Toledo Nóbrega, Rita de Cássia Marqueti, Graziella F. B. Cipriano, João Luiz Quagliotti Durigan, Eduardo Antônio Ferreira, Martim Bottaro, et al.

    Background: Low-frequency electrical stimulation (LFES) is an adjuvant method for heart failure (HF) patients with restrictions to start an exercise. However, the impact on molecular changes in circulating is unknown. We investigated the effects of 10 weeks of home-based LFES on plasma cytokines profile, redox biomarkers, metalloproteinases (MMPs) activity, and exercise performance in HF patients. Methods: Twenty-four HF patients (52.45 ± 9.15 years) with reduced ejection fraction (HFrEF) (EF < 40%), were randomly assigned to a home-based LFES or sham protocol. Plasma cytokines profile was assessed through interleukins, interferon-gamma, and tumor necrosis factor levels. Oxidative stress was evaluated through ferric reducing antioxidant power, thiobarbituric acid-reactive substances, and inducible nitric oxide synthase. The MMPs activity were analyzed by zymography. Cardiorespiratory capacity and muscle strength were evaluated by cardiopulmonary test and isokinetic. Results: LFES was able to increase the active-MMP2 activity post compared to pre-training (0.057 to 0.163, p = 0.0001), while it decreased the active-MMP9 (0.135 to 0.093, p = 0.02). However, it did not elicit changes in cytokines, redox biomarkers, or exercise performance (p > 0.05). Conclusion: LFES protocol is a promising intervention to modulate MMPs activity in HFrEF patients, although with limited functional effects. These preliminary responses may help the muscle to adapt to future mechanical demands dynamically.


  • Open Access

    Fratura da cabeça femoral de tipo II de Pipkin: Avaliação biomecânica pelo método de elementos finitos

    by Anderson Freitas, Nathallie Campos Demeneghi, Fabrício Reichert Barin, Leonardo Rigobello Battaglion, Robinson Esteves Pires, Vincenzo Giordano

    Objetivo Avaliar a capacidade biomecânica de duas formas de fixação de fraturas tipo II de Pipkin descrevendo o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Materiais e Métodos Dois fixadores internos foram desenvolvidos para tratar a fratura tipo II de Pipkin por meio de elementos finitos: parafuso cortical de 3,5 mm e parafuso de Herbert. Sob as mesmas condições, foram avaliados o desvio da fratura no sentido vertical, as tensões máxima e mínima principais, e a tensão equivalente de Von Mises nas sínteses utilizadas. Resultados Os deslocamentos verticais avaliados foram de 1,5 mm e 0,5 mm. Os valores de tensão máxima obtidos na região superior do colo femoral foram de 9,7 KPa e 1,3 KPa, e os valores de tensão mínima obtidos na região inferior do colo femoral foram de -8,7KPa e -9,3 KPa. Por fim, os valores de pico da tensão equivalente de Von Mises foram de 7,2 GPa e 2,0 GPa para os modelos de fixação com o uso do parafuso cortical de 3,5 mm e do parafuso de Herbert, respectivamente. Conclusão O sistema de fixação com parafuso de Herbert gerou os melhores resultados em termos de redução do deslocamento vertical, distribuição da tensão máxima e do pico da tensão equivalente de Von Mises, o que demonstra sua superioridade mecânica comparada à do parafuso cortical de 3,5 mm no tratamento da fratura tipo II de Pipkin. Os autores declaram que não receberam apoio financeiro de fontes públicas, comerciais, ou sem fins lucrativos para a realização deste estudo. * Trabalho desenvolvido no Instituto de Pesquisa e Ensino, Hospital Ortopédico e Medicina Especializada (IPE-HOME), Brasília, Distrito Federal, Brasil. Received: 16 January 2022 Accepted: 26 July 2022 Article published online: 03 October 2022 © 2022. Sociedade Brasileira de Ortopedia e Traumatologia. This is an open access article published by Thieme under the terms of the Creative Commons Attribution-NonDerivative-NonCommercial License, permitting copying and reproduction so long as the original work is given appropriate credit. Contents may not be used for commercial purposes, or adapted, remixed, transformed or built upon. (https://creativecommons.org/licenses/by-nc-nd/4.0/) Thieme Revinter Publicações Ltda. Rua do Matoso 170, Rio de Janeiro, RJ, CEP 20270-135, Brazil


  • Open Access

    FABREX: A NEW CLINICAL TEST FOR DIAGNOSIS GLUTEAL TENDINOPATHY

    by Anderson Freitas, Tatiane Morelati Rosa, Silvio Leite DE Macedo Neto, Vanessa DE Carvalho Bandeira, Diogo Ranier DE Macedo Souto, Fabrício Reichert Barin

    Objective: This study aims to describe a simple and accurate semiological method executing a specific maneuver with the lower limb to direct the semiological investigation towards the tendinopathies in the gluteus medius and minimus. Methods: Fifty patients participated in the study, with a mean age of 44.1 ± 13 years, with persistent pain on the side of the hip for more than three months. To compare the FABREX (proposed test) and Lequesne semiological tests, in the diagnosis of tendinopathies in the gluteus medius and minimus, Magnetic Resonance Imaging (MRI) was adopted as the gold standard. Results: FABREX presented high sensitivity and moderate specificity for tendinopathy in the gluteus medius and high sensitivity and specificity for tendinopathy in the gluteus minimus. Conclusion: The proposed test, when positive, can be used to determine the diagnosis of gluteal tendinopathies (high specificity). Moreover, it has high sensitivity, excluding the diagnosis when negative. This study represents the initial step for validating the FABREX test, and can therefore be considered a simple and accurate procedure to identify patients with or without gluteal tendinopathies. Level of Evidence III, Case Control Study.

  • Effects of proprioceptive exercises and strengthening on pain and functionality for patellofemoral pain syndrome in women: A randomized controlled trial

    by Marcos Vinicius da Silva Boitrago, Nayara Nepomuceno de Mello, Fabrício Reichert Barin, Paulo Lobo Júnior, José Humberto de Souza Borges, Marcio Oliveira


  • Proposal for a New Fixation Method for Pauwels Type III Femoral Neck Fracture-Metaphyseal Stem: A Finite-Element Analysis

    by Anderson Freitas, Fabrício Reichert Barin, Leonardo Rigobello Battaglion, Hélio Ismael da Costa, Eduardo Duarte Santos, Hugo Amando Rosado, Marcos Giordano, Vincenzo Giordano, Antonio Carlos Shimano

    Objective To evaluate the biomechanical behavior of a metaphyseal stem specifically designed for the fixation of Pauwels type-III femoral neck fractures using finite-element analysis. Methods Three different constructions were studied: the dynamic hip screw with a superior anti-rotation screw (DHS + ARS), multiple cannulated screws in an inverted triangle configuration (ASNIS), and the Metaphyseal Nailing System (MNS), a new implant developed by the authors. Vertical and total displacement, localized and total maximum and minimum principal, and the Von Mises peak stresses were evaluated. Results Results are shown for the DHS + ARS, ASNIS, and MNS models, respectively. Vertical displacement (mm) was 1.49, 3.63, and 1.90; total displacement (mm) was: 5.33, 6.02, and 6.30; localized maximum principal (Mpa) was: 2.77, 4.5, and 1.7; Total maximum principal (Mpa) was: 126, 223, and 531; localized minimum principal (Mpa) was: −1.8, −3.15, and −0.39; total minimum (Mpa) was: −121, −449, and −245; and Von Mises peak stress (MPA) was: 315.5, 326.1, and 286.0. Conclusion The present FEM study showed that the MNS device increases general stresses and reduces localized stresses, when compared to the DHS + ARS and ASNIS constructions used to fix Pauwels type-III femoral neck fracture in synthetic models. In this sense, the MNS showed a low fracture focus shift, conducive to the consolidation environment. The significant reduction in the maximum principal stress, allows to affirm that the main deforming force, the shear, in this fracture pattern, was considerably reduced and the low value of Von Mises obtained, consistent with an implant capable of making an effective load sharing.


  • New fixation method for Pauwels type III femoral neck fracture: a finite element analysis of sliding hip screw, L-shaped, and L-shaped with medial plate

    by Anderson Freitas, Ricardo Lourenço Bontempo, Frank Anderson Ramos Azevedo, Leonardo Rigobello Battaglion, Marcos Noberto Giordano, Fabrício Reichert Barin, Vincenzo Giordano

    Objective In this study, we aimed to evaluate the biomechanical behavior of three fixations for Pauwels type III fractures (sliding hip screw (SHS), L-shaped, and L-shaped with medial plate), by finite element analysis (FEM). Methods Three internal fixators were developed to treat Pauwels type III fracture by finite elements: SHS; L-shaped; and L-shaped with medial plate. Under the same conditions, localized and total vertical fracture displacement, maximum and minimum principal and von Mises stresses were evaluated. Results The localized and total vertical displacement evaluated for the SHS, L-shaped, and L-shaped with medial plate were 0.15 mm, 0.17 mm, and 0.07 mm (localized), and 4.52 mm, 6.97 mm, and 6.83 mm (total), respectively. The maximum values obtained in the upper region of the femoral neck for the internal fixations were 1.43 MPa, 1.29 MPa, and 1.24 MPa, and the minimum values obtained in the lower region of the femoral neck were − 0.73 MPa, − 1.09 MPa, and − 1.03 MPa, respectively. The maximum Von Mises peak stress values were 6.35 MPa, 10.7 MPa, and 16.2 MPa for the fixation models using the SHS, L-shaped, and L-shaped with medial plate, respectively. Conclusion The present FEM analysis showed that SHS yields better results in terms of total vertical displacements, maximum distribution, and Von Mises peak stresses reduction. On the other hand, the L-shaped construction plus a medial plate decreases localized vertical displacements and maximum principal distribution when compared to the SHS and L-shaped constructions. These results demonstrate that both constructions, SHS and L-shaped plus a medial plate, are biomechanically efficient for the fixation of Pauwels type III femoral neck fractures.


  • Open Access

    Exercise and Tendon Remodeling Mechanism

    by Rita de Cassia Marqueti, Ivo Vieira de Sousa Neto, Fabricio Reichert Barin, Gracielle Vieira Ramos

    Tendons connect muscles to bones and transmit the force exerted by the corresponding muscle to the skeleton and, therefore, are key components for locomotion. They are responsive to mechanical factors, which are essential for cellular functioning, tendon development, homeostasis, and repairing. Mechanical signals are transduced via molecular signaling pathways which trigger tendon adaptive responses. Previous data have already shown that exercise training promotes physiological adaptive responses, such as morphological properties and biomechanical and biochemical adaptations.


  • Open Access

    Detraining and Anabolic-Androgenic Steroid Discontinuation Change Calcaneal Tendon Morphology

    by Anderson José Santana Oliveira, Lívia Larissa Batista e Silva, Fabrício Reichert Barin, Elaine Cristina Leite Pereira, Heloisa Sobreiro Selistre-De-Araujo, Rita De Cássia Marqueti

    Several side effects of anabolic-androgenic steroid (AAS) administration associated with training are reported in the biomechanical properties of the calcaneal tendon (CT) of rats. Thus, the aim of the present study is to evaluate the effects of the detraining and discontinuation of AAS administration on the CT morphology of rats submitted to exercise in water. Animals were divided into two groups (20/group): (1) Immediately after training (IA), and (2) Six weeks of detraining and AAS discontinuation (6W). The IA group included four subgroups: Sedentary (S), Trained (T), Sedentary with AAS administration (SAAS), and trained with AAS administration (TAAS). The 6W group included four subgroups: Sedentary (6W-S), six weeks of detrained (6W-T), six weeks of sedentary with AAS discontinuation (6W-SAAS), and six weeks of detrained with AAS discontinuation (6W-TAAS). Data show significant reduction in adipose cells volume density (Vv%) in the distal CT in 6W-TAAS group, indicating that training can exert a positive effect on the tendon. The 6W-SAAS group exhibited increased adipose cells Vv% in the distal region, compared with the W6-S and W6-T groups. A decrease in tendon proper cells Vv% and in peritendinous sheath cells Vv% of proximal and distal regions was also observed. In 6W-TAAS group showed increase in adipose cells, blood vessels, peritendinous sheath cells, and tendon proper cells Vv% in the distal region of the CT. The vertical jumps in water were not able to protect CT regions from the negative effects of AAS discontinuation for six weeks. However, after detraining and AAS discontinuation, many protective factors of the mechanical load in the long-term could be observed.

  • Beneficial effects of resistance training on the protein profile of the calcaneal tendon during aging

    by Fabrício R. Barin, João Luiz Q. Durigan, Kléber de S. Oliveira, Ludovico Migliolo, Jeeser Alves Almeida, Marcia Carvalho, Bernardo Petriz, Heloisa Sobreiro Selistre-De-Araujo, Wagner Fontes, Octavio L. Franco, et al.