NSNathan Wm Skelley

Nathan Wm Skelley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nathan Wm Skelley has a total of 47 co-authors. Here are the top co-authors by number of shared publications:

  • Lisa N. MacFadden

    From the Sanford Orthopaedics and Sports Medicine, Sioux Falls, SD (Mr. Adams and Dr. Skelley), University of South Dakota Sanford School of Medicine, Sioux Falls, SD (Dr. MacFadden, Mr. O'Connor, Ms. VanDerWolde, and Dr. Skelley), University of South Dakota, Department of Biomedical Engineering, Sioux Falls, SD (Dr. MacFadden and Dr. Skelley), Viaflex, Sioux Falls, SD (Mr. Boerhave)

    3 shared publications
  • Benjamin C. Noonan

    Sanford Health

    2 shared publications
  • Luke W. Adams

    2 shared publications
  • Aaron M. Chamberlain

    Intermountain Health, Musculoskeletal Clinical Program, Salt Lake City, UT, USA

    1 shared publication
  • Alan L. Zhang

    Department of Orthopaedic Surgery University of California‐San Francisco San Francisco California U.S.A.

    1 shared publication
  • Atc Tiffany Barth

    Sanford Orthopedics and Sports Medicine Research, Sanford Health, Fargo, ND

    1 shared publication

Latest Publications

  • Open Access

    Augmentation of Rotator Cuff Repair With a Bioinductive Collagen Scaffold: The Arthroscopic Slide Technique

    by Peter A. Bueide, Jordan D. Shearer, Ryan M. Peldo, Nathan W. Skelley

    Rotator cuff repair continues to be one of the most common orthopaedic surgeries performed. However, depending on patient risk factors, retear rates remain high. We describe a technique for tensioning a collagen scaffold to supplement rotator cuff repair using laterally based pulley sutures. This ensures the scaffold is fixed in appropriate tension to function as a load‐sharing construct with rotator cuff repair. Aside from the biologic scaffold, this technique requires minimal extra implant costs except for 2 additional sutures.

  • Open Access

    Utilization of a 3D Printed Customized Knee Extender Device and An At-Home Video Rehabilitation Program on Patient Outcomes in Rural Areas Following ACL Surgery

    by Kevin P. Feltz, Brooklyn VanDerWolde, Kyle Cochran, Eleanor Gibbons, Benjamin C. Noonan, Nathan Wm. Skelley

    Background: Physical therapy is a critical component of postoperative rehabilitation after ACL surgery. However, access to formal physical therapy is not universal, and patients who do not receive adequate rehabilitation may experience worse postoperative outcomes. The primary objective of this study was to evaluate whether the addition of a low-cost, desktop 3D-printed knee extension device and at-home video program led to an increased rate of obtaining full knee extension following anterior cruciate ligament reconstruction in the early postoperative period. Hypothesis/Purpose: We hypothesized that there would be no difference in the percentage of patients achieving full knee extension by six weeks or in overall knee range of motion between the study and control groups. Secondary outcomes included device compliance, device issues, knee effusion, pain levels, usage characteristics, and skin/wound reactions. Methods This was a prospective, randomized, controlled pilot study. 32 participants aged 15–48 years with primary ACL ruptures were enrolled and randomized into two groups: a control group that received standard postoperative physical therapy rehabilitation, and an experimental group that received the same rehabilitation supplemented with a knee extension device and an at-home, video-guided exercise program. Patients were assessed over a 6-week postoperative period, recording knee circumference, range of motion, pain scores, time to full extension, safety, and device-related issues. Categorical variables were analyzed using chi-squared tests, and continuous variables were analyzed using t-tests and ANOVA. Results There were no differences between groups in six-week knee range of motion, knee circumference, pain scores, or time to full knee extension. Although a greater proportion of patients in the experimental group achieved full extension by Week 2, this difference was not statistically significant (p = 0.70). No adverse outcomes were reported in either group. Conclusion Overall, there were no statistically significant differences in outcomes between the control and study group. This study found that incorporating an at home video program and a custom low-cost desktop 3D printed knee sling into the postoperative ACL rehabilitation was safe, utilized appropriately, and had excellent patient compliance.

  • Open Access

    The 2026 Arthroscopy Association of North American Traveling Fellowship—Friends Who Travel Together, Stay Together

    by Alan L. Zhang, Nathan W. Skelley, David J. Tennent, Marina J. Rodriguez, Louis F. McIntyre

  • Open Access

    Concomitant cartilage restoration does not demonstrate consistent additional clinical benefit in medial patellofemoral ligament reconstruction: A systematic review.

    by Dave Osinachukwu Duru, Djamel Wade, Marc Daniel Bouchard, Prushoth Vivekanantha, Shahbaz S Malik, Nathan Wm Skelley, Bryson P Lesniak, Darren de Sa

    This review specifically evaluates whether the presence of cartilage lesions, or their surgical treatment, modifies the clinical benefit of medial patellofemoral ligament (MPFL) reconstruction. A systematic review was conducted following PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. Embase, PubMed and Ovid MEDLINE were searched from inception to December 2025. Studies reporting MPFL reconstruction outcomes in adults with reported cartilage lesions and/or concomitant cartilage procedures were included. Comparative studies were analysed as MPFL reconstruction with cartilage restoration versus MPFL reconstruction without cartilage restoration. Cartilage restoration included microfracture, osteochondral grafting, chondrocyte implantation and fixation of osteochondral lesions. Chondroplasty, debridement and no cartilage treatment were classified as nonrestorative. Data were synthesised narratively and with weighted summary statistics. Eighteen studies comprising 1632 patients were included. The mean age was 22.2 years, 32.5% of patients were male, and the mean follow-up was 40.8 months. Cartilage lesions were graded using the International Cartilage Repair Society or Outerbridge classifications. Grade II-IV cartilage lesions were reported in 56.3% of patients, most commonly involving the patella. High-grade (III-IV) lesions were associated with worse baseline scores compared to lower-grade (0-II) lesions. MPFL reconstruction consistently led to significant improvements in pain and function, irrespective of lesion presence or treatment strategy. Weighted summary mean improvements were similar between patients undergoing MPFL reconstruction with cartilage restoration versus no restoration, based on Knee injury and Osteoarthritis Outcome Score (KOOS) Pain (+24.5 [standard deviation, SD = 2.9] vs. +26.2 [2.3]), Kujala (+32.0 [16.6] vs. +30.4 [4.3]) and International Knee Documentation Committee (IKDC) (+25.0 [5.7] vs. +32.7 [1.4]) scores. Chondroplasty and debridement were included in the no restoration category when reported. Reported complication rates were higher with cartilage restoration (5.7%) compared with no restoration (2.8%), although reporting was limited. Cartilage lesions are common during MPFL reconstruction and may be associated with worse baseline scores. MPFL reconstruction improves pain and function, but current evidence does not demonstrate a consistent additional clinical benefit of concomitant cartilage restoration. Higher-quality comparative studies with longer follow-up are needed. Level IV, systematic review.

  • Open Access

    Effect of Time and Sex on Post–Anterior Cruciate Ligament Reconstruction Psychological Patient-Reported Outcome Measure Scores

    by Atc Tiffany Barth, PhD Colin W. Bond, Lisa N. MacFadden, Nathan Wm. Skelley, PsyD Josefine Combs, Benjamin C. Noonan, Investigation performed at Sanford Health

    Context: Low scores on psychological patient-reported outcomes measures, including the Anterior Cruciate Ligament—Return to Sport After Injury (ACL-RSI) and Injury-Psychological Readiness to Return to Sport (I-PRRS), after anterior cruciate ligament reconstruction (ACLR) have been associated with a maladaptive psychological response to injury and poor prognosis.Objective: To assess the effect of time post-ACLR and sex on ACL-RSI and I-PRRS scores and generate normative reference curves.Design: Case series.Setting: Outpatient sports medicine and orthopaedic clinic.Patients or Other Participants: A total of 507 patients (age at ACLR, 17.9 ± 3.0 years) who had undergone primary ACLR and completed ACL-RSI or I-PRRS assessments ≥1 times (n = 796) between 0 and 1 year post-ACLR.Main Outcome Measure(s): An honest broker provided anonymous data from our institution’s knee-injury clinical database. Generalized additive models for location, scale, and shape and generalized least-squares analyses were used to assess the effect of time post-ACLR and sex on ACL-RSI and I-PRRS scores.Results: The ACL-RSI and I-PRRS scores increased over time post-ACLR. Males had higher scores than females until approximately 5 months post-ACLR, with scores converging thereafter.Conclusions: Males reported higher ACL-RSI and I-PRRS scores than females in the initial stages of rehabilitation, but scores converged between sexes at times associated with return to play post-ACLR. Normative reference curves can be used to objectively appraise ACL-RSI and I-PRRS scores at any time post-ACLR. This may lead to timely recognition of patients with a maladaptive psychological response to injury and a higher likelihood of a poor prognosis, optimizing ACLR outcomes.


  • Open Access

    A Technique for Peripheral Compartment First and Periportal Access for Hip Arthroscopy

    by Edward R. Floyd, Tanner L. Kippes, Kyler A. Hardie, Nathan W. Skelley

    Hip arthroscopy has become the preferred method for surgical management of numerous hip pathologies. Traditionally, arthroscopic access to the hip has mainly been performed by starting in the central compartment first, which commonly requires capsulotomy and subsequent closure to access the hip joint. This technique is both technically challenging and has been associated with iatrogenic damage to the hip cartilage, as well as the labrum, potentially compromising the integrity of the hip capsule. In this Technical Note, we present our approach to hip arthroscopy that accesses the hip through the peripheral compartment first, with minimal periportal capsulotomies, using a post‐less traction bed. This technique can decrease the risk of iatrogenic damage, decrease surgical time, and improve visualization and accessibility for both novice and advanced hip arthroscopy surgeons. Technique Video: video See video under supplementary data.


  • Mechanical Analysis of a Novel 3D-printed External Fixator Design Versus Industry-standard External Fixators

    by Lisa N. MacFadden, Luke W. Adams, Clint Boerhave, Hunter A. O’COnnor, Brooklyn K. VanDerWolde, Nathan Wm. Skelley

    Introduction: External fixation is a critical component of orthopaedic fracture management and is used for various conditions, including trauma and pediatric orthopaedics. However, the availability and high cost of external fixation devices are a concern, especially in rural and developing countries. 3D printing technology has shown promise in reducing manufacturing costs and improving accessibility to external fixation devices. The purpose of this study was to evaluate the mechanical properties of a fully 3D-printed desktop external fixation device and compare the results with the mechanical properties of commonly used, clinically available external fixators. Methods: A fully 3D printable external fixator was designed and printed in polylactic acid at two infill densities, 20% and 100%. The mechanical properties of the 3D-printed external fixators and several commercially available fixators were tested according to applicable sections of the American Society for Testing and Materials F1541 standard protocol in axial, medial-lateral, and anterior-posterior orientations. The primary outcomes measured included failure load, safe load, rigidity, and yield load. The mean differences between experimental and control groups were calculated using one-way analysis of variance and Tukey tests. Results: The 20% infill 3D-printed construct showed poor performance compared with commercially available external fixators in all testing conditions and across most variables. The 100% infill 3D-printed construct was comparable with or superior to all commercially available devices in most testing conditions. The cost for printing a single 3D-printed 100% infill external fixator was $14.49 (United States Dollar). Discussion: This study demonstrates that a low-cost desktop 3D printer can create an entirely 3D-printed external fixator that resists clinically relevant forces similar to medical-grade industry-standard external fixators. Therefore, there is potential for customizable and low-cost external fixators to be manufactured with desktop 3D printing for use in remote areas and other resource-constrained environments for fracture care.


  • Open Access

    Poster 351: Relation Between Femoral Anterior Cruciate Ligament Tunnel Orientation and Anterolateral Ligament Tunnel Collision in a 3D-CT Model

    by Lisa MacFadden, Colin Bond, Nathan Skelley, Luke Adams

    Objectives: The anterolateral ligament (ALL) is an important structure for knee stability and has roles in maintaining internal knee rotation and anterior-posterior stability in anterior cruciate ligament (ACL)- insufficient knees. There is a growing body of evidence demonstrating superior clinical outcomes including reduced graft failure rate and residual pivot shift with combined ACL and ALL reconstruction compared to isolated ACL reconstruction. One common complication of this procedure is convergence of the two tunnels used for ACL and ALL graft passage. Several studies have aimed to determine the optimal angles to drill these tunnels that minimizes collision risk, but most of the literature is limited by few angle combinations or manipulation of the ALL tunnel exclusively. One study examined how changing the orientation of the femoral ACL tunnel affected collision risk, but they limited their investigation to the ACL tunnel angle in relation to a line perpendicular to the femoral axis. We aim to investigate the relation between the ACL tunnel angle in coronal and axial planes and risk of collision with the ALL tunnel as measured by the minimum distance between tunnels (MDBT). We hypothesize that there is a correlation between the minimum distance between ALL and ACL tunnels and the orientation of the ACL tunnel in both coronal and axial planes. Methods: This study was determined to be non-human subjects research by the Institutional Review Board. A 3D-CT reconstruction of a knee determined to be anatomically normal by a radiologist was de- identified and exported into the 3D modeling software Autodesk Fusion 360. The model was prepared for analysis based on previous 3D-CT reconstruction studies of the knee. The central longitudinal axis of the femur was set as the long axis, and the femur model was rotated so that the trans-epicondylar line was oriented with the x-axis. The model was then rotated so that the long axis was parallel to the z-axis in the sagittal plane. Based on the results of multiple prior studies evaluating the optimal ALL tunnel orientation, a “safe” ALL tunnel angle of 40° anterior in the axial plane and 10° proximal in the coronal plane was used for all ALL-ACL combinations. The ALL attachment site was designated as 8mm proximal and 4.3mm posterior to the lateral epicondyle. The ALL tunnel was modeled as a cylinder 30mm long and 6mm in diameter with the cylinder center placed at the attachment site. The ACL tunnel was modeled as a cylinder 8mm in diameter with a 4mm diameter cylinder at one end to represent an EndoButton tunnel. The cylinders were then rotated in 15° increments up to 60° in both coronal and axial planes until 25 unique ACL tunnel orientations were created. (Figure 2) For each orientation, the center of the large cylinder face was placed at the anatomic ACL footprint, and the cylinder was extended until the Endobutton tunnel penetrated the lateral cortex. The MDBT was then measured, and a 2mm clearance between tunnels was designated as satisfactory to avoid tunnel convergence. A collision was recorded if the cylinders overlapped in the 3D model. Linear regression was used to determine the relation between the dependent variable of MDBT and the independent variables of axial and coronal angles. Significance was set to p < 0.05. Results: A collision occurred in 36% of orientations, with unsatisfactory clearance between tunnels in 20% of orientations and satisfactory clearance in the remaining 44%. The axial angle producing the largest average MDBT was 0°, with an average MDBT of 9.47mm and zero collisions across all coronal angles. The coronal angle producing the largest average MDBT was also 0°, with an average MDBT of 3.93mm across all axial angles. An axial angle of 60° produced the lowest average MDBT across all coronal angles at 1.26mm and three collisions. A coronal angle of 15° produced the lowest average MDBT across all axial angles at 1.26mm and three collisions. The linear regression analysis had an R2 of 0.424. There was a negative association between ACL tunnel axial angle and MDBT indicating that as the ACL tunnel axial angle increases, MDBT decreases (β = –0.654 ,p < 0.001). There was no evidence of a relation between ACL tunnel coronal angle and MDBT (β =0.209, p=0.19). Conclusions: Despite using an ALL tunnel determined in previous studies to be optimal for avoiding collisions, tunnel collision or dangerously close tunnel proximity occurred in over half of the ACL orientations tested. These findings help to reinforce that the risk of tunnel collision in combined ACL- ALL reconstruction is high if not properly accounted for. They also raise awareness that even when using an ALL tunnel deemed optimal to avoid collisions, there remains a large proportion of ACL tunnel orientations that create a high risk for tunnel convergence. The linear regression model demonstrates that with coronal orientation held constant, a more anteriorly angled tunnel in the axial plane decreases the MDBT and increases risk for tunnel collision. Further work should involve performing similar methodology on a larger scale with more patients, in order to determine an optimal ACL tunnel angle that minimizes collision risk across a population. These findings also suggest a role for 3D-CT modeling in preoperative planning at the individual level, given the high risk of tunnel collision and anatomic differences between patients. [Table: see text]

  • Open Access

    Design and Development of a Novel 3-D Printed External Fixation Device for Fracture Stabilization

    by Nathan Wm. Skelley

    Background: An external fixator is an orthopaedic device used to stabilize long bone fractures after high energy trauma. These devices are external to the body and fixed to metal pins going into non-injured areas of bone. They serve a mechanical function to maintain length, prevent bending, and resist torque forces about the fracture area. The purpose of this manuscript is to describe a design and prototyping process creating a low-cost entirely 3-D printed external fixator for fracture stabilization of extremity fractures. The secondary objective of this manuscript is to facilitate future advancements, modifications, and innovations in this area of 3-D printing in medicine. Methods: This manuscript describes the computer aided design process using desktop fused deposition modeling to create a 3-D printed external fixator system designed for fracture stabilization. The device was created using the orthopaedic goals for fracture stabilization with external fixation. However, special modifications and considerations had to be accounted for given the limitations of desktop fused deposition modeling and 3-D printing with plastic polymers. Results: The presented device accomplishes the goals of creating a construct that can be attached to 5.0 mm metal pins, allows for modularity in placement orientations, and facilitates adjustable lengths for fracture care. Furthermore, the device provides length stability, prevention of bending, and resists torque forces. The device can be printed on a desktop 3-D printer using standard low-cost polylactic acid filament. The print time is less than two days and can be completed on one print bed platform. Conclusions: The presented device is a potential alternative for fracture stabilization. The concept of a desktop 3-D printed external fixator design and method of production allows for numerous diverse applications. This includes assisting areas with remote or limited access to advanced medical care and large-scale natural disasters or global conflicts where large volumes of fractures exceed the local medical supply chain capabilities. The presented device creates a foundation for future devices and innovations in this fracture care space. Further research is needed on mechanical testing and clinical outcomes with this design and initiative in fracture care before clinical application.


  • Open Access

    3D Printed Orthopaedic External Fixation Devices: A Systematic Review

    by Hunter A. O’cOnnor, Luke W. Adams, Lisa N. MacFadden, Nathan Wm. Skelley

    Background: External fixators are complex, expensive orthopaedic devices used to stabilize high-energy and complex fractures of the extremities. Although the technology has advanced dramatically over the last several decades, the mechanical goals for fracture stabilization of these devices have remained unchanged. Three-dimensional (3D) printing technology has the potential to advance the practice and access to external fixation devices in orthopaedics. This publication aims to systematically review and synthesize the current literature on 3D printed external fixation devices for managing orthopaedic trauma fractures. Methods: The Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) protocols were followed for this manuscript with minor exceptions. PubMed, Embase, Cochrane Review, Google Scholar, and Scopus online databases were systematically searched. Two independent reviewers screened the search results based on predetermined inclusion and exclusion criteria related to 3D printing and external fixation of fractures. Results: Nine studies met the inclusion criteria. These included one mechanical testing study, two computational simulation studies, three feasibility studies, and three clinical case studies. Fixator designs and materials varied significantly between authors. Mechanical testing revealed similar strength to traditional metal external fixators. Across all clinical studies, five patients underwent definitive treatment with 3D printed external fixators. They all had satisfactory reduction and healing with no reported complications. Conclusions: The current literature on this topic is heterogeneous, with highly variable external fixator designs and testing techniques. A small and limited number of studies in the scientific literature have analyzed the use of 3D printing in this area of orthopaedic surgery. 3D printed external fixation design advancements have yielded promising results in several small clinical case studies. However, additional studies on a larger scale with standardized testing and reporting techniques are needed.