MFMina Farshidgohar

Mina Farshidgohar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mina Farshidgohar has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Long-Term Follow-up of Transcatheter Ventricular Septal Defect Closure in Children, and Comparison of Single-Hole Versus Multi-holes Ventricular Septal Defects

    by Hojjat Mortezaeian, Mina Farshidgohar, Ahmad Vesal, Behzad Alizadeh, Yasaman Khalili, Mahmood Meraji, Nikolaus Haas

    Background: Evaluation of complications after transcatheter ventricular septal defect (VSD) closure in long-term follow-up and large samples of children is limited. Objectives: We compared the residual shunt after transcatheter closure in VSDs with a single hole and multiple holes, a new task that has not been done so far. Methods: This retrospective study included all patients who underwent transcatheter device closure for VSD in a tertiary cardiovascular center from 2009 to 2020. Follow-up evaluation using transthoracic echocardiography (TTE) and electrocardiogram (ECG) was performed at 1, 6, 12 months, and annually after the procedure. Results: A total of 409 patients underwent transcatheter VSD closure. The mean age was 7 years (2 - 15 years), and the median follow-up duration was 48 months (1 - 10 years). The number of patients with a singular VSD was 259 (63.4%), and those with multiple exit holes were 150 (36.6%). The incidence of a residual shunt immediately after implantation was significantly higher in VSDs with multiple holes than those with a single hole (P = 0.008). During the follow-up, the residual shunts decreased in the group of VSDs with a single hole. Forty-five patients (11%) and 16 patients (4%) had a new-onset of mild and moderate tricuspid regurgitation (TR), respectively, and it decreased dramatically over time. Only 1 patient showed a new-onset mild aortic regurgitation (AR). The most crucial complication shown in 2 patients was a persistent complete heart block. Conclusions: Ventricular septal defects with multiple exit holes are a risk factor for a residual shunt. After transcatheter VSD closure, the residual shunt in patients with a multiple-hole VSD was significantly higher (P = 0.008). Although TR may increase during the procedure, it decreases dramatically over time. Interestingly, patients who had pre-procedure tricuspid or aortic regurgitation disappeared after 2 years of the procedure. The most important complication was a complete heart block in 2 patients.

  • Rare presentation of COVID-19 in 6-year-old girl: myocarditis with severe restrictive diastolic dysfunction

    by Victoria Chegini, Fatemeh Omidi, Fatemeh Shojaeian, Hamidreza Hatamabadi, Mina Farshidgohar

    The article's abstract is not available.


  • Intravascular Ultrasound for Assessment of Residual Coarctation of the Aorta after Balloon Angioplasty in Infants

    by Hojjat Mortezaeian, Yasaman Khalili, Majid Farrokhi, Saleheh Tajalli, Akbar Shah Mohammadi, Ahmad Vesal, Fariba Alaei, Ata Firouzi, Omid Shafe, Mina Farshid Gohar, et al.

    Intravascular ultrasound (IVUS) has been introduced as an accurate and minimally invasive diagnostic technique for the assessment of vascular anatomy and its abnormalities. We believe that IVUS can be used for clarifying the reasons for failure of balloon angiography in infantile coarctation of the aorta (CoA), because post-balloon angioplasty tearing, intimal flap, thrombosis and pseudoaneurysm of the aorta can be evaluated by IVUS with greater sensitivity and specificity. We aimed to assess the outcome of balloon angioplasty of CoA using angiography as the gold standard and IVUS as a new method in infants, comparing the two techniques for the evaluation of the diameter and area of CoA segment pre- and post-procedure. This cross-sectional study was performed on 18 infants hospitalized with a final diagnosis of CoA. All the infants underwent angiography and were also assessed by IVUS to measure the preoperative and postoperative diameter of the narrow segment in the two anterior–posterior and lateral views. In assessment by IVUS, the mean diameter of the coarctation site increased from 2.10 ± 0.30 mm to 4.50 ± 0.94 mm (P < 0.001). Similarly, the average minimum area of the coarctation level increased from 5.26 ± 1.50 mm2 to 13.77 ± 3.48 mm2 after angioplasty (P < 0.001). Comparing these findings, angiography and IVUS showed a high level of agreement. In the assessment of a dissection flap, there was a high level of agreement between angioplasty and IVUS before the procedure, but IVUS had higher accuracy after the procedure. Our study showed that IVUS was more reliable than angiography in the assessment of residual coarctation. IVUS yielded high sensitivity (58.3%) and specificity (100%) for discriminating the presence and absence of residual coarctation as well as the need for repeating the procedure. The assessment of coarctation before and after angioplasty procedures in children is possible using the IVUS method, with high accuracy. IVUS can offer greater accuracy than angiography in the evaluation of the coarctation area, detecting tears, dissection and flaps, and assessment of residual coarctation.