Elisabet A. Rank
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Elisabet A. Rank has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Rainer Andreas Leitgeb
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Vienna, Austria
6 shared publications Wolfgang Drexler
Medizinische Univ. Wien (Austria)
6 shared publicationsJochen Kraft
Ams-OSRAM AG (Austria)
5 shared publicationsMartin Sagmeister
Ams-OSRAM AG (Austria)
5 shared publicationsRainer Hainberger
AIT Austrian Institute of Technology GmbH (Austria)
5 shared publications- Wolfgang Drexler
Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, Währinger Gürtel 18-20, 1090 Vienna, Austria
5 shared publications
Latest Publications
- 8 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12890, 32-44
Silicon nitride photonic integrated circuits for optical coherence tomography
We report on the progress of our efforts to apply silicon nitride photonic integrated circuits (PIC) to the miniaturization of optical coherence tomography (OCT) with the goal of facilitating its widespread use in ophthalmology at the point of care. In particular, we highlight the design and optical characterization of photonic building blocks allowing the realization of a silicon nitride PIC-based multi-channel swept-source OCT system in the 1060 nm wavelength region. Apart from waveguide structures, these building blocks include 3D-printed microlenses on the PIC end facets for efficient light coupling to and from the PIC.
- 8 March 2024
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12890, 32-44
Silicon nitride photonic integrated circuits for optical coherence tomography
We report on the progress of our efforts to apply silicon nitride photonic integrated circuits (PIC) to the miniaturization of optical coherence tomography (OCT) with the goal of facilitating its widespread use in ophthalmology at the point of care. In particular, we highlight the design and optical characterization of photonic building blocks allowing the realization of a silicon nitride PIC-based multi-channel swept-source OCT system in the 1060 nm wavelength region. Apart from waveguide structures, these building blocks include 3D-printed microlenses on the PIC end facets for efficient light coupling to and from the PIC.
- 6 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12369, PC123690G
Optoelectronic system based on photonic integrated circuits to miniaturize spectral domain OCT (Conference Presentation)
We present a miniaturized optical coherence tomography (OCT) setup based on photonic integrated circuits (PIC) for the 850 nm range. We designed a 512-channel arrayed waveguide grating (AWG) on a PIC for spectral domain OCT (SD-OCT) that is co-integrated with PIN-photodiodes and analog-to-digital-converters on one single chip. This image sensor is combined with all the necessary electronics to act as a camera. It is integrated into a fiber-based OCT system, achieving a sensitivity of >80dB and various samples are imaged. This optoelectronic system will allow building small and cost-effective OCT systems to monitor retinal diseases.
- 6 March 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC12369, PC123690G
Optoelectronic system based on photonic integrated circuits to miniaturize spectral domain OCT (Conference Presentation)
We present a miniaturized optical coherence tomography (OCT) setup based on photonic integrated circuits (PIC) for the 850 nm range. We designed a 512-channel arrayed waveguide grating (AWG) on a PIC for spectral domain OCT (SD-OCT) that is co-integrated with PIN-photodiodes and analog-to-digital-converters on one single chip. This image sensor is combined with all the necessary electronics to act as a camera. It is integrated into a fiber-based OCT system, achieving a sensitivity of >80dB and various samples are imaged. This optoelectronic system will allow building small and cost-effective OCT systems to monitor retinal diseases.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC11948, PC119480K
Multi-channel 400 kHz 840nm swept-source OCT system based on a photonic-electronic integrated circuit
We report on a swept-source OCT system based on a photonic-electronic integrated circuit. It enables a parallelization of data acquisition resulting in an effective A-scan rate of 4x100 kHz at a central wavelength of 840 nm. The monolithic co-integration of photonic elements forming the multiplexed interferometers and the system electronics on one chip allows a very compact OCT engine in a photonic package. Integrated in an ophthalmic system, the maximum sensitivity was estimated to be 91 dB with an optical power of 4x520 µW at the model eye. An eye phantom was imaged at 400 kHz showing its layered structure.
- 7 March 2022
- Published by SPIE-Intl Soc Optical Eng
- Vol. PC11948, PC119480K
Multi-channel 400 kHz 840nm swept-source OCT system based on a photonic-electronic integrated circuit
We report on a swept-source OCT system based on a photonic-electronic integrated circuit. It enables a parallelization of data acquisition resulting in an effective A-scan rate of 4x100 kHz at a central wavelength of 840 nm. The monolithic co-integration of photonic elements forming the multiplexed interferometers and the system electronics on one chip allows a very compact OCT engine in a photonic package. Integrated in an ophthalmic system, the maximum sensitivity was estimated to be 91 dB with an optical power of 4x520 µW at the model eye. An eye phantom was imaged at 400 kHz showing its layered structure.
- Open Access
- 20 December 2021
- Published by Wiley in Translational Biophotonics
- Vol. 4 (1-2)
Miniaturizing optical coherence tomography
Optical coherence tomography (OCT) has revolutionized ophthalmic diagnosis as a non‐invasive, cross‐sectional imaging technique in the last 30 years and hence is one of the fastest adopted advanced imaging technologies in the history of medicine. A miniaturization of OCT devices would not only reduce size but ideally also reduce costs and therefore create potential new markets. OCT systems based on photonic integrated circuits (PIC) could enable a significant miniaturization of complex systems with high degree of integration as well as low costs of goods. These therefore have a potential to enable portable, cost‐effective, high performing, real handheld OCT devices. This review identifies three main categories towards miniaturized OCT devices: Handheld imaging probes interfaced to a (mobile) base station, compact home/self‐ OCT and PIC‐based OCT. Imaging performance parameters and technical readiness levels of the identified miniaturized OCT systems for (non‐) ophthalmic applications are presented. Special attention is paid to PIC‐based OCT applications and their progress.Picture: First in vivo human retinal tomogram using a PIC‐based subcomponent (arrayed waveguide grating, AWG) of a spectral domain OCT system. Adapted with permission from E. A. Rank et al.,Light Sci Appl.2021,10, 1, CC By 4.0. Copyright © 2021, The Author(s).
- 20 December 2021
- Published by Wiley in Translational Biophotonics
- Vol. 4 (1-2)
Open AccessMiniaturizing optical coherence tomography
Optical coherence tomography (OCT) has revolutionized ophthalmic diagnosis as a non‐invasive, cross‐sectional imaging technique in the last 30 years and hence is one of the fastest adopted advanced imaging technologies in the history of medicine. A miniaturization of OCT devices would not only reduce size but ideally also reduce costs and therefore create potential new markets. OCT systems based on photonic integrated circuits (PIC) could enable a significant miniaturization of complex systems with high degree of integration as well as low costs of goods. These therefore have a potential to enable portable, cost‐effective, high performing, real handheld OCT devices. This review identifies three main categories towards miniaturized OCT devices: Handheld imaging probes interfaced to a (mobile) base station, compact home/self‐ OCT and PIC‐based OCT. Imaging performance parameters and technical readiness levels of the identified miniaturized OCT systems for (non‐) ophthalmic applications are presented. Special attention is paid to PIC‐based OCT applications and their progress.Picture: First in vivo human retinal tomogram using a PIC‐based subcomponent (arrayed waveguide grating, AWG) of a spectral domain OCT system. Adapted with permission from E. A. Rank et al.,Light Sci Appl.2021,10, 1, CC By 4.0. Copyright © 2021, The Author(s).
- Open Access
- 26 October 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
In vivo human retinal swept source optical coherence tomography and angiography at 830 nm with a CMOS compatible photonic integrated circuit
Photonic integrated circuits (PIC) provide promising functionalities to significantly reduce the size and costs of optical coherence tomography (OCT) systems. This paper presents an imaging platform operating at a center wavelength of 830 nm for ophthalmic application using PIC-based swept source OCT. An on-chip Mach–Zehnder interferometer (MZI) configuration, which comprises an input power splitter, polarization beam splitters in the sample and the reference arm, and a 50/50 coupler for signal interference represents the core element of the system with a footprint of only $$(12 \times 5)\;{\text {mm}}^2$$ . The system achieves 94 dB imaging sensitivity with 750 $$\upmu $$ W on the sample, 50 kHz imaging speed and 5.5 $$\upmu $$ m axial resolution (in soft tissue). With this setup, in vivo human retinal imaging of healthy subjects was performed producing B-scans, three-dimensional renderings as well as OCT angiography. These promising results are significant prerequisites for further integration of optical and electronic building blocks on a single swept source-OCT PIC.- 26 October 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1-12
Open AccessIn vivo human retinal swept source optical coherence tomography and angiography at 830 nm with a CMOS compatible photonic integrated circuit
Photonic integrated circuits (PIC) provide promising functionalities to significantly reduce the size and costs of optical coherence tomography (OCT) systems. This paper presents an imaging platform operating at a center wavelength of 830 nm for ophthalmic application using PIC-based swept source OCT. An on-chip Mach–Zehnder interferometer (MZI) configuration, which comprises an input power splitter, polarization beam splitters in the sample and the reference arm, and a 50/50 coupler for signal interference represents the core element of the system with a footprint of only $$(12 \times 5)\;{\text {mm}}^2$$ . The system achieves 94 dB imaging sensitivity with 750 $$\upmu $$ W on the sample, 50 kHz imaging speed and 5.5 $$\upmu $$ m axial resolution (in soft tissue). With this setup, in vivo human retinal imaging of healthy subjects was performed producing B-scans, three-dimensional renderings as well as OCT angiography. These promising results are significant prerequisites for further integration of optical and electronic building blocks on a single swept source-OCT PIC. - Open Access
- 20 October 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (10) , 100601
Enhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography
Optical coherence tomography (OCT) is one of the most innovative and successfully translated imaging techniques with substantial clinical and economic impacts and acceptance.1,2 OCT is a non-invasive optical analog to ultrasound (US) with significantly higher resolution () enabling three- and four-dimensional high-speed (>millions of A-scans/s) imaging with tissue penetration of up to 2 mm, closely matching that of conventional histopathology. The year 2021 marks not only the 30th birthday of OCT (assuming its initiation with the Science paper by Huang et al.3 in 1991) but also the 35th birthday of low-coherence interferometry and optical ranging in biological systems.4,5 In the last three decades, more than 75,000 OCT related papers have been published (about two thirds in ophthalmology) with continuous yearly increases of published articles.6 Breaking through the 1000 publications/year barrier was initiated in 2005/2006 with the introduction of spectral domain OCT (SD OCT). In 2020, the OCT-related scientific output was more than 7800 papers, resulting in nearly one paper every single hour on every single day of the year. Extrapolating this publishing performance, a saturation of yearly publication output at about 9500 can be expected around 2030. After 30 years, it is interesting and important to benchmark this performance with other medical imaging techniques:6 multiphoton microscopy (MPM) [including second harmonic generation (SHG) and third harmonic generation (THG)], developed about three decades before OCT,7,8 has about 50,000 publications so far; photoacoustic imaging (PAI), established in the 1970s,9,10 has about 15,000 papers; and confocal microscopy, developed in the 1940s,11,12 has about 145,000. Developed in the 1940s,13 US imaging has contributed to about 160,000 papers; positron emission tomography (PET), initiated in the 1970s,14,15 has about 175,000; computed tomography (CT), developed in the 1930s,16 has about 750,000; and magnetic resonance imaging (MRI), developed in the late 1940s,17 has close to 1,000,000 publications. This dominance in publications of radiology and nuclear medicine imaging technologies is also one of the reasons why medical imaging is, in general, associated with MRI, CT, PET, or US. It is important to note, though, that from a medical imaging market perspective, optical imaging technologies dominate with 66% versus 34% for radiology and nuclear medicine imaging technologies. In addition, in the United States alone, about 450,000 physicians use primarily optical imaging techniques; 60,000 use primarily radiologic imaging; and about 130,000 use both.18- 20 October 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (10) , 100601
Open AccessEnhanced medical diagnosis for dOCTors: a perspective of optical coherence tomography
Optical coherence tomography (OCT) is one of the most innovative and successfully translated imaging techniques with substantial clinical and economic impacts and acceptance.1,2 OCT is a non-invasive optical analog to ultrasound (US) with significantly higher resolution () enabling three- and four-dimensional high-speed (>millions of A-scans/s) imaging with tissue penetration of up to 2 mm, closely matching that of conventional histopathology. The year 2021 marks not only the 30th birthday of OCT (assuming its initiation with the Science paper by Huang et al.3 in 1991) but also the 35th birthday of low-coherence interferometry and optical ranging in biological systems.4,5 In the last three decades, more than 75,000 OCT related papers have been published (about two thirds in ophthalmology) with continuous yearly increases of published articles.6 Breaking through the 1000 publications/year barrier was initiated in 2005/2006 with the introduction of spectral domain OCT (SD OCT). In 2020, the OCT-related scientific output was more than 7800 papers, resulting in nearly one paper every single hour on every single day of the year. Extrapolating this publishing performance, a saturation of yearly publication output at about 9500 can be expected around 2030. After 30 years, it is interesting and important to benchmark this performance with other medical imaging techniques:6 multiphoton microscopy (MPM) [including second harmonic generation (SHG) and third harmonic generation (THG)], developed about three decades before OCT,7,8 has about 50,000 publications so far; photoacoustic imaging (PAI), established in the 1970s,9,10 has about 15,000 papers; and confocal microscopy, developed in the 1940s,11,12 has about 145,000. Developed in the 1940s,13 US imaging has contributed to about 160,000 papers; positron emission tomography (PET), initiated in the 1970s,14,15 has about 175,000; computed tomography (CT), developed in the 1930s,16 has about 750,000; and magnetic resonance imaging (MRI), developed in the late 1940s,17 has close to 1,000,000 publications. This dominance in publications of radiology and nuclear medicine imaging technologies is also one of the reasons why medical imaging is, in general, associated with MRI, CT, PET, or US. It is important to note, though, that from a medical imaging market perspective, optical imaging technologies dominate with 66% versus 34% for radiology and nuclear medicine imaging technologies. In addition, in the United States alone, about 450,000 physicians use primarily optical imaging techniques; 60,000 use primarily radiologic imaging; and about 130,000 use both.18 - Open Access
- 17 June 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (06) , 065001-24
Adaptive compounding speckle-noise-reduction filter for optical coherence tomography images
Optical coherence tomography (OCT)1 is an optical imaging technique that allows cross-sectional views of in vivo tissue in real time with micrometer resolution and at depths of up to two millimeters. OCT is widely used in a variety of biomedical and clinical fields, such as ophthalmology (as a routine noninvasive tool for the diagnosis and monitoring of disease progression)2 and cardiology (as a catheter-based imaging system during coronary intervention).3 In dermatology, OCT has been used to study a variety of dermatological disorders.4,5 The most significant dermatological applications of OCT are in assessing non-melanoma skin cancers such as basal cell carcinoma (BCC) and in reducing the need for diagnostic biopsies.6 – 8
- 17 June 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 26 (06) , 065001-24
Open AccessAdaptive compounding speckle-noise-reduction filter for optical coherence tomography images
Optical coherence tomography (OCT)1 is an optical imaging technique that allows cross-sectional views of in vivo tissue in real time with micrometer resolution and at depths of up to two millimeters. OCT is widely used in a variety of biomedical and clinical fields, such as ophthalmology (as a routine noninvasive tool for the diagnosis and monitoring of disease progression)2 and cardiology (as a catheter-based imaging system during coronary intervention).3 In dermatology, OCT has been used to study a variety of dermatological disorders.4,5 The most significant dermatological applications of OCT are in assessing non-melanoma skin cancers such as basal cell carcinoma (BCC) and in reducing the need for diagnostic biopsies.6 – 8
- Top Cited PapersOpen Access
- 5 January 2021
- Published by Springer Nature in Light: Science & Applications
- Vol. 10 (1) , 1-15
Toward optical coherence tomography on a chip: in vivo three-dimensional human retinal imaging using photonic integrated circuit-based arrayed waveguide gratings
In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.
- 5 January 2021
- Published by Springer Nature in Light: Science & Applications
- Vol. 10 (1) , 1-15
Top Cited PapersOpen AccessToward optical coherence tomography on a chip: in vivo three-dimensional human retinal imaging using photonic integrated circuit-based arrayed waveguide gratings
In this work, we present a significant step toward in vivo ophthalmic optical coherence tomography and angiography on a photonic integrated chip. The diffraction gratings used in spectral-domain optical coherence tomography can be replaced by photonic integrated circuits comprising an arrayed waveguide grating. Two arrayed waveguide grating designs with 256 channels were tested, which enabled the first chip-based optical coherence tomography and angiography in vivo three-dimensional human retinal measurements. Design 1 supports a bandwidth of 22 nm, with which a sensitivity of up to 91 dB (830 µW) and an axial resolution of 10.7 µm was measured. Design 2 supports a bandwidth of 48 nm, with which a sensitivity of 90 dB (480 µW) and an axial resolution of 6.5 µm was measured. The silicon nitride-based integrated optical waveguides were fabricated with a fully CMOS-compatible process, which allows their monolithic co-integration on top of an optoelectronic silicon chip. As a benchmark for chip-based optical coherence tomography, tomograms generated by a commercially available clinical spectral-domain optical coherence tomography system were compared to those acquired with on-chip gratings. The similarities in the tomograms demonstrate the significant clinical potential for further integration of optical coherence tomography on a chip system.
- Open Access
- 23 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (12) , 2371
Combination of High-Resolution Optical Coherence Tomography and Raman Spectroscopy for Improved Staging and Grading in Bladder Cancer
We present a combination of optical coherence tomography (OCT) and Raman spectroscopy (RS) for improved diagnosis and discrimination of different stages and grades of bladder cancer ex vivo by linking the complementary information provided by these two techniques. Bladder samples were obtained from biopsies dissected via transurethral resection of the bladder tumor (TURBT). As OCT provides structural information rapidly, it was used as a red-flag technology to scan the bladder wall for suspicious lesions with the ability to discriminate malignant tissue from healthy urothelium. Upon identification of degenerated tissue via OCT, RS was implemented to determine the molecular characteristics via point measurements at suspicious sites. Combining the complementary information of both modalities allows not only for staging, but also for differentiation of low-grade and high-grade cancer based on a multivariate statistical analysis. OCT was able to clearly differentiate between healthy and malignant tissue by tomogram inspection and achieved an accuracy of 71% in the staging of the tumor, from pTa to pT2, through texture analysis followed by k-nearest neighbor classification. RS yielded an accuracy of 93% in discriminating low-grade from high-grade lesions via principal component analysis followed by k-nearest neighbor classification. In this study, we show the potential of a multi-modal approach with OCT for fast pre-screening and staging of cancerous lesions followed by RS for enhanced discrimination of low-grade and high-grade bladder cancer in a non-destructive, label-free and non-invasive way.
- 23 November 2018
- Published by MDPI AG in Applied Sciences
- Vol. 8 (12) , 2371
Open AccessCombination of High-Resolution Optical Coherence Tomography and Raman Spectroscopy for Improved Staging and Grading in Bladder Cancer
We present a combination of optical coherence tomography (OCT) and Raman spectroscopy (RS) for improved diagnosis and discrimination of different stages and grades of bladder cancer ex vivo by linking the complementary information provided by these two techniques. Bladder samples were obtained from biopsies dissected via transurethral resection of the bladder tumor (TURBT). As OCT provides structural information rapidly, it was used as a red-flag technology to scan the bladder wall for suspicious lesions with the ability to discriminate malignant tissue from healthy urothelium. Upon identification of degenerated tissue via OCT, RS was implemented to determine the molecular characteristics via point measurements at suspicious sites. Combining the complementary information of both modalities allows not only for staging, but also for differentiation of low-grade and high-grade cancer based on a multivariate statistical analysis. OCT was able to clearly differentiate between healthy and malignant tissue by tomogram inspection and achieved an accuracy of 71% in the staging of the tumor, from pTa to pT2, through texture analysis followed by k-nearest neighbor classification. RS yielded an accuracy of 93% in discriminating low-grade from high-grade lesions via principal component analysis followed by k-nearest neighbor classification. In this study, we show the potential of a multi-modal approach with OCT for fast pre-screening and staging of cancerous lesions followed by RS for enhanced discrimination of low-grade and high-grade bladder cancer in a non-destructive, label-free and non-invasive way.
- 18 October 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (21) , 4319-4322
Dual modality reflection mode optical coherence and photoacoustic microscopy using an akinetic sensor
This Letter presents a novel dual modality reflection mode optical coherence and photoacoustic microscopy (OC-PAM) system. The optical coherence microscopy modality features a broadband source to accomplish 5 μm axial resolution. The photoacoustic microscopy modality uses a rigid akinetic Fabry–Perot etalon encapsulated in an optically transparent medium, which forms a translucent imaging window, permitting reflection mode dual modality imaging. After characterization, the OC-PAM system was applied to image zebrafish larvae in vivo, demonstrating its capability in biomedical imaging with complementary optical scattering and absorption contrasts by revealing morphology in the fish larvae.- 18 October 2017
- Published by Optica Publishing Group in Optics Letters
- Vol. 42 (21) , 4319-4322
Dual modality reflection mode optical coherence and photoacoustic microscopy using an akinetic sensor
This Letter presents a novel dual modality reflection mode optical coherence and photoacoustic microscopy (OC-PAM) system. The optical coherence microscopy modality features a broadband source to accomplish 5 μm axial resolution. The photoacoustic microscopy modality uses a rigid akinetic Fabry–Perot etalon encapsulated in an optically transparent medium, which forms a translucent imaging window, permitting reflection mode dual modality imaging. After characterization, the OC-PAM system was applied to image zebrafish larvae in vivo, demonstrating its capability in biomedical imaging with complementary optical scattering and absorption contrasts by revealing morphology in the fish larvae.