Kanmaniraja Radhakrishnan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kanmaniraja Radhakrishnan has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Jun Su Park
Department of Automotive Engineering, Korea National University of Transportation, Chungju 27469, Republic of Korea
3 shared publications - Hyoung Jin Lee
Department of Aerospace Engineering and Aerospace System Research Institute, Inha University, Korea
2 shared publications - Dong Hwi Ha
Department of Aerospace Engineering, Inha University, 36, Gaetbeol-ro, Yeonsu-gu, Incheon 21999, Republic of Korea
1 shared publication Jaye Koo
School of Aerospace and Mechanical Engineering, Korea Aerospace University,Goyang, Gyeonggi, 412-791, Republic of Korea
1 shared publication- Jongmin Shin1 shared publication
- Nam Ho Kim
Department of Mechanical and Aerospace Engineering, University of Florida, Gainesville, FL, USA
1 shared publication
Latest Publications
- Open Access
Effect of Multicoaxial Injectors on Nitrogen Film Cooling in a GCH4/GO2 Thrust Chamber for Small-Scale Methane Rocket Engines: A CFD Study
Improper film cooling design and positioning of an injector in the face plate cause thermal damage to the thrust chamber wall and lead to rocket engine failures. An experimental combustor with five shear coaxial injectors was damaged owing to inadequate film cooling distribution on the thrust chamber wall. The present study aimed to simulate the experimental test case and investigate the causes of the thermal damage. In the simulation, gaseous methane and oxygen were injected at the inner and outer inlets of the shear coaxial injectors and nitrogen, used as the coolant, was injected near the upstream of the chamber wall. The turbulent chemistry interaction was modeled using a reduced DRM-19 mechanism by incorporating the Eddy Dissipation Concept model. Numerical investigations were conducted to examine the cause of thermal damage. The temperature contours of the thrust chamber wall were compared with the experimental image of the damaged wall. Further, simulations of single-row (SR) and multi-row (MR) injector configurations were conducted to assess the effect on film cooling distribution. The adiabatic film cooling effectiveness and specific impulse were determined for all simulated cases. The results showed that MR simulations with narrow injector angles had poor film cooling performance, while wider angles led to lower specific impulse. The face plate with an angle of 15 degrees between the injector positions showed better performance in terms of considering both the film cooling and specific impulse.
Open AccessEffect of Multicoaxial Injectors on Nitrogen Film Cooling in a GCH4/GO2 Thrust Chamber for Small-Scale Methane Rocket Engines: A CFD Study
Improper film cooling design and positioning of an injector in the face plate cause thermal damage to the thrust chamber wall and lead to rocket engine failures. An experimental combustor with five shear coaxial injectors was damaged owing to inadequate film cooling distribution on the thrust chamber wall. The present study aimed to simulate the experimental test case and investigate the causes of the thermal damage. In the simulation, gaseous methane and oxygen were injected at the inner and outer inlets of the shear coaxial injectors and nitrogen, used as the coolant, was injected near the upstream of the chamber wall. The turbulent chemistry interaction was modeled using a reduced DRM-19 mechanism by incorporating the Eddy Dissipation Concept model. Numerical investigations were conducted to examine the cause of thermal damage. The temperature contours of the thrust chamber wall were compared with the experimental image of the damaged wall. Further, simulations of single-row (SR) and multi-row (MR) injector configurations were conducted to assess the effect on film cooling distribution. The adiabatic film cooling effectiveness and specific impulse were determined for all simulated cases. The results showed that MR simulations with narrow injector angles had poor film cooling performance, while wider angles led to lower specific impulse. The face plate with an angle of 15 degrees between the injector positions showed better performance in terms of considering both the film cooling and specific impulse.
- Open Access
Flow and Heat Transfer Characteristics of Superheater Tube of a Pulverized Coal-Fired Boiler Using Conjugate Heat Transfer Modeling
This study is a numerical study to predict the temperature of the heat exchange tubes inside the pulverized coal-fired boiler through the conjugate heat transfer analysis. Due to the aspect ratio and number of tubes inside the pulverized coal-fired boiler, actual tube modeling analysis has rarely been conducted. Most of the research has been conducted through the porous media method, resulting in limited information on the temperature distribution of each tube. However, for the development of a digital twin model for improving the performance of the boiler and reducing maintenance costs, information on the local temperature of the tubes is required. In this study, all the tubes inside the boiler were modeled, and conjugate heat transfer analysis was performed to confirm the local temperature distribution. For this purpose, the analysis was conducted using Fluent 2020 r2, and the analysis model was constructed using more than 300 million structured grids. The calculation was performed considering conjugate heat transfer in the pulverized coal-fired boiler, heat exchange by steam inside the tubes, and conductive heat transfer of the tubes. As a result, it was confirmed that there is a significant deviation in the local temperature for each tube position. Furthermore, the maximum temperature of the PrSH tube ranges widely, between 492 and 532 degrees, depending on the tube’s position. It was observed that the point of the highest temperature inside the tubes also varies for each tube due to the flow of external combustion gas. Based on these results, it is expected that strategic approaches to boiler design and maintenance can be achieved. Furthermore, it is anticipated to contribute to the high efficiency of power facilities by being utilized as basic data for the development of a digital twin model for the boiler.
Open AccessFlow and Heat Transfer Characteristics of Superheater Tube of a Pulverized Coal-Fired Boiler Using Conjugate Heat Transfer Modeling
This study is a numerical study to predict the temperature of the heat exchange tubes inside the pulverized coal-fired boiler through the conjugate heat transfer analysis. Due to the aspect ratio and number of tubes inside the pulverized coal-fired boiler, actual tube modeling analysis has rarely been conducted. Most of the research has been conducted through the porous media method, resulting in limited information on the temperature distribution of each tube. However, for the development of a digital twin model for improving the performance of the boiler and reducing maintenance costs, information on the local temperature of the tubes is required. In this study, all the tubes inside the boiler were modeled, and conjugate heat transfer analysis was performed to confirm the local temperature distribution. For this purpose, the analysis was conducted using Fluent 2020 r2, and the analysis model was constructed using more than 300 million structured grids. The calculation was performed considering conjugate heat transfer in the pulverized coal-fired boiler, heat exchange by steam inside the tubes, and conductive heat transfer of the tubes. As a result, it was confirmed that there is a significant deviation in the local temperature for each tube position. Furthermore, the maximum temperature of the PrSH tube ranges widely, between 492 and 532 degrees, depending on the tube’s position. It was observed that the point of the highest temperature inside the tubes also varies for each tube due to the flow of external combustion gas. Based on these results, it is expected that strategic approaches to boiler design and maintenance can be achieved. Furthermore, it is anticipated to contribute to the high efficiency of power facilities by being utilized as basic data for the development of a digital twin model for the boiler.
- Open Access
Thermal Analysis and Creep Lifetime Prediction Based on the Effectiveness of Thermal Barrier Coating on a Gas Turbine Combustor Liner Using Coupled CFD and FEM Simulation
Thermal barrier coating (TBC) plays a vital role in the gas turbine combustor liner (CL) to mitigate the internal heat transfer from combustion gas to the CL and enhance the parent material lifetime of the CL. This present study examined the thermal analysis and creep lifetime prediction based on three different TBC thicknesses, 400, 800, and 1200 μm, coated on the inner CL using the coupled computational fluid dynamics/finite element method. The simulation method was divided into three models to minimize the amount of computational work involved. The Eddy Dissipation Model was used in the first model to simulate premixed methane-air combustion, and the wall temperature of the inner CL was obtained. The conjugate heat transfer simulation on the external cooling flows from the rib turbulator, impingement jet, and cross flow, and the wall temperature of the outer CL was obtained in the second model. The thermal analysis was carried out in the third model using three different TBC thicknesses and incorporating the wall data from the first and second model. The effect of increasing TBC thickness shows that the TBC surface temperature was increased. Thereby, the inner CL metal temperature was decreased due to the TBC thickness as well as the material properties of Yttria Stabilized Zirconia, which has low thermal conductivity and a high thermal expansion coefficient. With the increase in TBC thickness, the average temperature difference between the TBC surface and the inner metal surface increased. In contrast, the average temperature difference between the inner and outer metal surfaces remained nearly constant. The von Mises equivalent stress, based on the material property and thermal expansion coefficient, was determined and used to find the creep lifetime of the CL using the Larson–Miller rupture curve for all TBC thickness cases in order to analyze the thermo-structure. Except in the C-channel, the increasing TBC thickness was found to effectively increase the CL lifespan. Furthermore, the case without TBC was compared with the damaged CL with cracks due to thermal stress, which was prevented by increasing TBC thickness shown in this present study.
Open AccessThermal Analysis and Creep Lifetime Prediction Based on the Effectiveness of Thermal Barrier Coating on a Gas Turbine Combustor Liner Using Coupled CFD and FEM Simulation
Thermal barrier coating (TBC) plays a vital role in the gas turbine combustor liner (CL) to mitigate the internal heat transfer from combustion gas to the CL and enhance the parent material lifetime of the CL. This present study examined the thermal analysis and creep lifetime prediction based on three different TBC thicknesses, 400, 800, and 1200 μm, coated on the inner CL using the coupled computational fluid dynamics/finite element method. The simulation method was divided into three models to minimize the amount of computational work involved. The Eddy Dissipation Model was used in the first model to simulate premixed methane-air combustion, and the wall temperature of the inner CL was obtained. The conjugate heat transfer simulation on the external cooling flows from the rib turbulator, impingement jet, and cross flow, and the wall temperature of the outer CL was obtained in the second model. The thermal analysis was carried out in the third model using three different TBC thicknesses and incorporating the wall data from the first and second model. The effect of increasing TBC thickness shows that the TBC surface temperature was increased. Thereby, the inner CL metal temperature was decreased due to the TBC thickness as well as the material properties of Yttria Stabilized Zirconia, which has low thermal conductivity and a high thermal expansion coefficient. With the increase in TBC thickness, the average temperature difference between the TBC surface and the inner metal surface increased. In contrast, the average temperature difference between the inner and outer metal surfaces remained nearly constant. The von Mises equivalent stress, based on the material property and thermal expansion coefficient, was determined and used to find the creep lifetime of the CL using the Larson–Miller rupture curve for all TBC thickness cases in order to analyze the thermo-structure. Except in the C-channel, the increasing TBC thickness was found to effectively increase the CL lifespan. Furthermore, the case without TBC was compared with the damaged CL with cracks due to thermal stress, which was prevented by increasing TBC thickness shown in this present study.
- Open Access
Multi-Fidelity Surrogate Models for Predicting Averaged Heat Transfer Coefficients on Endwall of Turbine Blades
This paper proposes a multi-fidelity surrogate (MFS) model for predicting the heat transfer coefficient (HTC) on the turbine blades. First, the low-fidelity (LF) and high-fidelity (HF) surrogates were built using LF-data from numerical simulation and HF-data from an experiment. To evaluate the prediction by these two surrogates, the averaged HTC distribution on the endwall of the gas turbine blade predicted by these two surrogates was compared for input variables as Reynolds number () and boundary layer (BL) thickness. This shows that the prediction by LF surrogate is saturated with an increase in , while has monotonic behavior with an increase in BL thickness, which is contrary in general. The prediction by HF surrogate is linear with and is increased with BL thickness up to 30 mm and then decreased after 30 mm. Following this, a one-dimensional projection of the two-dimensional HTC distribution was presented to show the prediction tendency of the surrogates by varying the and fixing the BL thickness, and vice versa. Second, the MFS was built by combining the LF and HF data. The HTC distribution by the MFS model for the same input variables was shown with the HF data points. It is observed that the prediction by MFS is agreed well with the high-fidelity data. The MFS’s one-dimensional projection of the two-dimensional HTC distribution was compared with the LF surrogate prediction by varying the and fixing the BL thickness, and vice versa. This shows that the MFS model has more variations due to the included LF data. It is worth to mention that the averaged HTC distribution with an increase in boundary layer thickness predicted by the MFS is agreed well with the LF and HF data in the available dataset and has a large confidence interval between 30 and 50 mm due to the unavailable data in the specified range. To check the MFS accuracy, the root-mean-square error (RMSE) and error rate were evaluated to compare with the experimental uncertainty for a wide range of high-fidelity data. The present study shows that MFS would be expected to be an effective model for saving computing time and experimental costs.Open AccessMulti-Fidelity Surrogate Models for Predicting Averaged Heat Transfer Coefficients on Endwall of Turbine Blades
This paper proposes a multi-fidelity surrogate (MFS) model for predicting the heat transfer coefficient (HTC) on the turbine blades. First, the low-fidelity (LF) and high-fidelity (HF) surrogates were built using LF-data from numerical simulation and HF-data from an experiment. To evaluate the prediction by these two surrogates, the averaged HTC distribution on the endwall of the gas turbine blade predicted by these two surrogates was compared for input variables as Reynolds number () and boundary layer (BL) thickness. This shows that the prediction by LF surrogate is saturated with an increase in , while has monotonic behavior with an increase in BL thickness, which is contrary in general. The prediction by HF surrogate is linear with and is increased with BL thickness up to 30 mm and then decreased after 30 mm. Following this, a one-dimensional projection of the two-dimensional HTC distribution was presented to show the prediction tendency of the surrogates by varying the and fixing the BL thickness, and vice versa. Second, the MFS was built by combining the LF and HF data. The HTC distribution by the MFS model for the same input variables was shown with the HF data points. It is observed that the prediction by MFS is agreed well with the high-fidelity data. The MFS’s one-dimensional projection of the two-dimensional HTC distribution was compared with the LF surrogate prediction by varying the and fixing the BL thickness, and vice versa. This shows that the MFS model has more variations due to the included LF data. It is worth to mention that the averaged HTC distribution with an increase in boundary layer thickness predicted by the MFS is agreed well with the LF and HF data in the available dataset and has a large confidence interval between 30 and 50 mm due to the unavailable data in the specified range. To check the MFS accuracy, the root-mean-square error (RMSE) and error rate were evaluated to compare with the experimental uncertainty for a wide range of high-fidelity data. The present study shows that MFS would be expected to be an effective model for saving computing time and experimental costs. - 31 December 2019
- Published by Begell House Inc. Publishers in Atomization and Sprays
- Vol. 30 (2) , 75-95
VOLUME OF FLUID SIMULATION OF SHEET FORMATION AND PRIMARY BREAKUP OF NON-NEWTONIAN PROPELLANTS IN A PINTLE INJECTOR WITH VARIABLE INJECTION AREAS
Two-dimensional axisymmetric large eddy simulation was conducted to model the sheet formation and primary breakup of gelled kerosene and gelled hydrogen peroxide in a pintle injector. This was done by varying the pintle opening distance. To simulate a hollow conical gelled hydrogen peroxide sheet from the center gap and the sheet breakup by the gelled kerosene from the annular gap, volume of fluid (VOF) simulation was employed. Here, the viscosity was considered as a function of the shear rate. The power law expression for hydrogen peroxide and the Herschel-Bulkley extended expression for kerosene were used as the user-defined function codes. The variations of the breakup length, wavelength, and the amplitude of the formed sheet due to disturbance waves using VOF simulation with varied pintle opening distances were studied. The viscosity distributions due to the shear rate of the gel flow and the velocity at the exit of the injector were plotted to investigate the gel flow behavior.
- 31 December 2019
- Published by Begell House Inc. Publishers in Atomization and Sprays
- Vol. 30 (2) , 75-95
VOLUME OF FLUID SIMULATION OF SHEET FORMATION AND PRIMARY BREAKUP OF NON-NEWTONIAN PROPELLANTS IN A PINTLE INJECTOR WITH VARIABLE INJECTION AREAS
Two-dimensional axisymmetric large eddy simulation was conducted to model the sheet formation and primary breakup of gelled kerosene and gelled hydrogen peroxide in a pintle injector. This was done by varying the pintle opening distance. To simulate a hollow conical gelled hydrogen peroxide sheet from the center gap and the sheet breakup by the gelled kerosene from the annular gap, volume of fluid (VOF) simulation was employed. Here, the viscosity was considered as a function of the shear rate. The power law expression for hydrogen peroxide and the Herschel-Bulkley extended expression for kerosene were used as the user-defined function codes. The variations of the breakup length, wavelength, and the amplitude of the formed sheet due to disturbance waves using VOF simulation with varied pintle opening distances were studied. The viscosity distributions due to the shear rate of the gel flow and the velocity at the exit of the injector were plotted to investigate the gel flow behavior.