Jed C. Wilbur
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jed C. Wilbur has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Abigail M. Fellows
Geisel School of Medicine at Dartmouth, Hanover, USA
3 shared publications - Jay C. Buckey
Geisel School of Medicine at Dartmouth Hanover NH USA
3 shared publications - Albert Magohe
Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
2 shared publications - Christopher E. Niemczak
Geisel School of Medicine at Dartmouth College, Hanover, New Hampshire, USA
2 shared publications - Enica Richard Massawe
Department of Otorhinolaryngology, School of Clinical medicine, Muhimbili University of Health and Allied Sciences, Dar es Salaam, Tanzania
2 shared publications - Jiang Gui
Dartmouth College
2 shared publications
Latest Publications
- 6 June 2026
- Published by Springer Nature in Annals of Biomedical Engineering
Design and Validation of a Stiffness-Matched Cervical Spine Surrogate
The purpose of this study was to develop a novel, low-cost, moldable cervical spine surrogate through topology optimization, using a validated human body model as ground truth to guide design and ensure biofidelity during multiplanar loading. The Global Human Body Models Consortium 50th percentile male pedestrian model (GHBMC M50) was used to establish multiplanar behavior by isolating the osteoligamentous cervical spine (OLS). Planar loading simulations in LS-Dyna were conducted to characterize the OLS response. These outputs served as target metrics for topology optimization to generate an anatomically inspired cervical spine surrogate. The optimization aimed to minimize volume fraction while constraining the design within volumetric bounds loosely defined by the GHBMC M50P OLS geometry and enforcing sagittal symmetry. Material properties of a two-part resin selected for fabrication were integrated into the optimization to ensure mechanical fidelity and enable a single-part, single-pour design. The final surrogate was fabricated using a custom two-part mold and tested under flexion, extension, and lateral bending using a six-degree-of-freedom robotic platform replicating the original simulation conditions. Trajectory-matched comparison of the GHBMC-M50 OLS and the novel surrogate yielded 1.5 N-m, 1.3 N-m, 0.1 N-m, and 0.2 N-m differences in moment required to traverse a physiologically relevant range of moment in flexion, extension, and left and right lateral bending respectively. Preliminary validation testing demonstrated that topology optimization enabled the creation of a monolithic, low-cost resin surrogate capable of replicating the biofidelic behavior of the GHBMC-M50P OLS.
- 6 June 2026
- Published by Springer Nature in Annals of Biomedical Engineering
Design and Validation of a Stiffness-Matched Cervical Spine Surrogate
The purpose of this study was to develop a novel, low-cost, moldable cervical spine surrogate through topology optimization, using a validated human body model as ground truth to guide design and ensure biofidelity during multiplanar loading. The Global Human Body Models Consortium 50th percentile male pedestrian model (GHBMC M50) was used to establish multiplanar behavior by isolating the osteoligamentous cervical spine (OLS). Planar loading simulations in LS-Dyna were conducted to characterize the OLS response. These outputs served as target metrics for topology optimization to generate an anatomically inspired cervical spine surrogate. The optimization aimed to minimize volume fraction while constraining the design within volumetric bounds loosely defined by the GHBMC M50P OLS geometry and enforcing sagittal symmetry. Material properties of a two-part resin selected for fabrication were integrated into the optimization to ensure mechanical fidelity and enable a single-part, single-pour design. The final surrogate was fabricated using a custom two-part mold and tested under flexion, extension, and lateral bending using a six-degree-of-freedom robotic platform replicating the original simulation conditions. Trajectory-matched comparison of the GHBMC-M50 OLS and the novel surrogate yielded 1.5 N-m, 1.3 N-m, 0.1 N-m, and 0.2 N-m differences in moment required to traverse a physiologically relevant range of moment in flexion, extension, and left and right lateral bending respectively. Preliminary validation testing demonstrated that topology optimization enabled the creation of a monolithic, low-cost resin surrogate capable of replicating the biofidelic behavior of the GHBMC-M50P OLS.
- Open Access
- 9 February 2021
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 5 (2) , e26406
Central Auditory Tests to Track Cognitive Function in People With HIV: Longitudinal Cohort Study
Background: The development of neurocognitive deficits in people infected with HIV is a significant public health problem. Previous cross-sectional studies have shown that performance on central auditory tests (CATs) correlates with cognitive test results in those with HIV, but no longitudinal data exist for confirmation. We have been performing longitudinal assessments of central auditory and cognitive function on a cohort of HIV-positive and HIV-negative individuals in Dar es Salaam, Tanzania to understand how the central auditory system could be used to study and track the progress of central nervous system dysfunction. Objective: The goal of the project was to determine if CATs can track the trajectory of cognitive function over time in people diagnosed with HIV. Methods: Tests of peripheral and central auditory function as well as cognitive performance were performed on 382 individuals over the course of 3.5 years. Visits were scheduled every 6 months. CATs included tests of auditory temporal processing (gap detection) and speech perception in noise (Hearing in Noise Test and Triple Digit Test). Cognitive tests included the Montreal Cognitive Assessment (MoCA), Test of Variables of Attention (TOVA), and subtests from the Cogstate battery. HIV-positive subjects were divided into groups based on their CAT results at their final visit (bottom 20%, top 20%, middle 60%). Primary analyses focused on the comparison between HIV-positive individuals that performed worse on CATs (bottom 20%) and the overall HIV-positive group (middle 60%). Data were analyzed using linear mixed-effect models with time as the main fixed effect. Results: The group with the worst (bottom 20%) CAT performance showed a difference in trajectory for the MoCA (P=.003), TOVA (P<.048), and Cogstate (P<.046) over the course of the study period compared to the overall HIV-positive group. A battery of three CATs showed a significant difference in cognitive trajectory over a relatively short study period of 3.5 years independent of age (bottom 20% vs HIV-positive group). Conclusions: The results of this study support the ability for CATs to track cognitive function over time, suggesting that central auditory processing can provide a window into central nervous system performance. CATs can be simple to perform, and are relatively insensitive to education and socioeconomic status because they only require repeating sentences, numbers, or detecting gaps in noise. These tests could potentially provide a time-efficient, low-cost method to screen for and monitor cognitive decline in patients with HIV, making them a useful surveillance tool for this major public health problem.
- 9 February 2021
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 5 (2) , e26406
Open AccessCentral Auditory Tests to Track Cognitive Function in People With HIV: Longitudinal Cohort Study
Background: The development of neurocognitive deficits in people infected with HIV is a significant public health problem. Previous cross-sectional studies have shown that performance on central auditory tests (CATs) correlates with cognitive test results in those with HIV, but no longitudinal data exist for confirmation. We have been performing longitudinal assessments of central auditory and cognitive function on a cohort of HIV-positive and HIV-negative individuals in Dar es Salaam, Tanzania to understand how the central auditory system could be used to study and track the progress of central nervous system dysfunction. Objective: The goal of the project was to determine if CATs can track the trajectory of cognitive function over time in people diagnosed with HIV. Methods: Tests of peripheral and central auditory function as well as cognitive performance were performed on 382 individuals over the course of 3.5 years. Visits were scheduled every 6 months. CATs included tests of auditory temporal processing (gap detection) and speech perception in noise (Hearing in Noise Test and Triple Digit Test). Cognitive tests included the Montreal Cognitive Assessment (MoCA), Test of Variables of Attention (TOVA), and subtests from the Cogstate battery. HIV-positive subjects were divided into groups based on their CAT results at their final visit (bottom 20%, top 20%, middle 60%). Primary analyses focused on the comparison between HIV-positive individuals that performed worse on CATs (bottom 20%) and the overall HIV-positive group (middle 60%). Data were analyzed using linear mixed-effect models with time as the main fixed effect. Results: The group with the worst (bottom 20%) CAT performance showed a difference in trajectory for the MoCA (P=.003), TOVA (P<.048), and Cogstate (P<.046) over the course of the study period compared to the overall HIV-positive group. A battery of three CATs showed a significant difference in cognitive trajectory over a relatively short study period of 3.5 years independent of age (bottom 20% vs HIV-positive group). Conclusions: The results of this study support the ability for CATs to track cognitive function over time, suggesting that central auditory processing can provide a window into central nervous system performance. CATs can be simple to perform, and are relatively insensitive to education and socioeconomic status because they only require repeating sentences, numbers, or detecting gaps in noise. These tests could potentially provide a time-efficient, low-cost method to screen for and monitor cognitive decline in patients with HIV, making them a useful surveillance tool for this major public health problem.
- Open Access
- 10 December 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Central Auditory Tests to Track Cognitive Function in People With HIV: Longitudinal Cohort Study (Preprint)
BACKGROUND The development of neurocognitive deficits in people infected with HIV is a significant public health problem. Previous cross-sectional studies have shown that performance on central auditory tests (CATs) correlates with cognitive test results in those with HIV, but no longitudinal data exist for confirmation. We have been performing longitudinal assessments of central auditory and cognitive function on a cohort of HIV-positive and HIV-negative individuals in Dar es Salaam, Tanzania to understand how the central auditory system could be used to study and track the progress of central nervous system dysfunction. OBJECTIVE The goal of the project was to determine if CATs can track the trajectory of cognitive function over time in people diagnosed with HIV. METHODS Tests of peripheral and central auditory function as well as cognitive performance were performed on 382 individuals over the course of 3.5 years. Visits were scheduled every 6 months. CATs included tests of auditory temporal processing (gap detection) and speech perception in noise (Hearing in Noise Test and Triple Digit Test). Cognitive tests included the Montreal Cognitive Assessment (MoCA), Test of Variables of Attention (TOVA), and subtests from the Cogstate battery. HIV-positive subjects were divided into groups based on their CAT results at their final visit (bottom 20%, top 20%, middle 60%). Primary analyses focused on the comparison between HIV-positive individuals that performed worse on CATs (bottom 20%) and the overall HIV-positive group (middle 60%). Data were analyzed using linear mixed-effect models with time as the main fixed effect. RESULTS The group with the worst (bottom 20%) CAT performance showed a difference in trajectory for the MoCA (P=.003), TOVA (P<.048), and Cogstate (P<.046) over the course of the study period compared to the overall HIV-positive group. A battery of three CATs showed a significant difference in cognitive trajectory over a relatively short study period of 3.5 years independent of age (bottom 20% vs HIV-positive group). CONCLUSIONS The results of this study support the ability for CATs to track cognitive function over time, suggesting that central auditory processing can provide a window into central nervous system performance. CATs can be simple to perform, and are relatively insensitive to education and socioeconomic status because they only require repeating sentences, numbers, or detecting gaps in noise. These tests could potentially provide a time-efficient, low-cost method to screen for and monitor cognitive decline in patients with HIV, making them a useful surveillance tool for this major public health problem.
- 10 December 2020
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessCentral Auditory Tests to Track Cognitive Function in People With HIV: Longitudinal Cohort Study (Preprint)
BACKGROUND The development of neurocognitive deficits in people infected with HIV is a significant public health problem. Previous cross-sectional studies have shown that performance on central auditory tests (CATs) correlates with cognitive test results in those with HIV, but no longitudinal data exist for confirmation. We have been performing longitudinal assessments of central auditory and cognitive function on a cohort of HIV-positive and HIV-negative individuals in Dar es Salaam, Tanzania to understand how the central auditory system could be used to study and track the progress of central nervous system dysfunction. OBJECTIVE The goal of the project was to determine if CATs can track the trajectory of cognitive function over time in people diagnosed with HIV. METHODS Tests of peripheral and central auditory function as well as cognitive performance were performed on 382 individuals over the course of 3.5 years. Visits were scheduled every 6 months. CATs included tests of auditory temporal processing (gap detection) and speech perception in noise (Hearing in Noise Test and Triple Digit Test). Cognitive tests included the Montreal Cognitive Assessment (MoCA), Test of Variables of Attention (TOVA), and subtests from the Cogstate battery. HIV-positive subjects were divided into groups based on their CAT results at their final visit (bottom 20%, top 20%, middle 60%). Primary analyses focused on the comparison between HIV-positive individuals that performed worse on CATs (bottom 20%) and the overall HIV-positive group (middle 60%). Data were analyzed using linear mixed-effect models with time as the main fixed effect. RESULTS The group with the worst (bottom 20%) CAT performance showed a difference in trajectory for the MoCA (P=.003), TOVA (P<.048), and Cogstate (P<.046) over the course of the study period compared to the overall HIV-positive group. A battery of three CATs showed a significant difference in cognitive trajectory over a relatively short study period of 3.5 years independent of age (bottom 20% vs HIV-positive group). CONCLUSIONS The results of this study support the ability for CATs to track cognitive function over time, suggesting that central auditory processing can provide a window into central nervous system performance. CATs can be simple to perform, and are relatively insensitive to education and socioeconomic status because they only require repeating sentences, numbers, or detecting gaps in noise. These tests could potentially provide a time-efficient, low-cost method to screen for and monitor cognitive decline in patients with HIV, making them a useful surveillance tool for this major public health problem.
- 1 April 2014
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 116 (7) , 790-796
Microbubbles are detected prior to larger bubbles following decompression
Using dual-frequency ultrasound (DFU), microbubbles (n = 15) were exposed to 4.0–4.5 ATA for 2 h, followed by decompression to 0.98 ATA. Microbubble presence and VGE grade were measured using DFU and B-mode ultrasound, respectively, before and for 1 h postdecompression, approximately every 4–5 min. Microbubbles appeared in the bloodstream postdecompression, both in the presence and absence of bmdVGE. In swine without bmdVGE, microbubbles remained elevated for the entire 60-min postdecompression period. In swine with bmdVGE, microbubble signals were detected initially but then returned to baseline. Microbubbles were not detected with the sham dive. Mean bmdVGE grade increased over the length of the postdecompression data collection period. Comparison of the two response curves revealed significant differences at 5 and 10 min postdecompression, indicating that microbubbles preceded bmdVGE. These findings indicate that decompression-induced microbubbles can 1) be detected intravascularly at multiple sites, 2) appear in the presence and absence of bmdVGE, and 3) occur before bmdVGE. This supports the hypothesis that microbubbles precede larger VGE bubbles. Microbubble presence may be an early marker of decompression stress. Since DFU is a low-power ultrasonic method, it may be useful for operational diving applications.
- 1 April 2014
- Published by American Physiological Society in Journal of Applied Physiology
- Vol. 116 (7) , 790-796
Microbubbles are detected prior to larger bubbles following decompression
Using dual-frequency ultrasound (DFU), microbubbles (n = 15) were exposed to 4.0–4.5 ATA for 2 h, followed by decompression to 0.98 ATA. Microbubble presence and VGE grade were measured using DFU and B-mode ultrasound, respectively, before and for 1 h postdecompression, approximately every 4–5 min. Microbubbles appeared in the bloodstream postdecompression, both in the presence and absence of bmdVGE. In swine without bmdVGE, microbubbles remained elevated for the entire 60-min postdecompression period. In swine with bmdVGE, microbubble signals were detected initially but then returned to baseline. Microbubbles were not detected with the sham dive. Mean bmdVGE grade increased over the length of the postdecompression data collection period. Comparison of the two response curves revealed significant differences at 5 and 10 min postdecompression, indicating that microbubbles preceded bmdVGE. These findings indicate that decompression-induced microbubbles can 1) be detected intravascularly at multiple sites, 2) appear in the presence and absence of bmdVGE, and 3) occur before bmdVGE. This supports the hypothesis that microbubbles precede larger VGE bubbles. Microbubble presence may be an early marker of decompression stress. Since DFU is a low-power ultrasonic method, it may be useful for operational diving applications.
- 1 October 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (4) , 2468
Protecting beyond the bone-conduction limit
- 1 October 2011
- Published by Acoustical Society of America (ASA) in The Journal of the Acoustical Society of America
- Vol. 130 (4) , 2468
Protecting beyond the bone-conduction limit