Robin H. Heijmen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Robin H. Heijmen has a total of 309 co-authors. Here are the top co-authors by number of shared publications:
- Guillaume S. C. Geuzebroek
Department of Cardiothoracic Surgery, Radboud University Medical Centre, Nijmegen, The Netherlands
6 shared publications - Adine R. de Keijzer
Department of Cardiothoracic Surgery, Erasmus University Medical Centre , PO Box 2040, 3000 CA Rotterdam, The
3 shared publications - Johanna Josepha Maria Takkenberg
Department of Cardiothoracic Surgery, Erasmus University Medical Center, Rotterdam, Netherlands
3 shared publications - Jolien W. Roos-Hesselink
Department of Cardiology, Cardiovascular Institute, Thorax Center, Erasmus MC, Rotterdam, The Netherlands
3 shared publications - Jos A. Bekkers
Department of Cardiothoracic Surgery, Erasmus University Medical Centre , PO Box 2040, 3000 CA Rotterdam, The
3 shared publications - Kevin M. Veen
Department of Cardiothoracic Surgery, Erasmus MC, Rotterdam, The Netherlands
3 shared publications
Latest Publications
- Open Access
- 12 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (4)
Divergent aortic root cusp-to-cusp measurement techniques on CMR: geometric implications and threshold reclassification
Objective: To evaluate discrepancies between current European guidelines (ESC vs. EACTS) regarding aortic root cusp-to-cusp measurements and assess their impact on risk stratification for prophylactic root replacement. Methods and results: A retrospective analysis was performed on a relative young cohort of 50 patients (mean age 42 years) who underwent non-contrast 3D cardiovascular magnetic resonance (CMR) imaging. We compared the widest-to-widest cusp measurements and the middle cusp-to-cusp measurements with each other and against a traced aortic root perimeter. The widest cusp-to-cusp measurement yielded systematically higher values compared to the middle measurement, showing a significant mean difference of 3.60 mm (P < 0.001). The middle measurement demonstrated better statistical agreement with the traced aortic root perimeter, achieving a Lin’s Concordance Correlation Coefficient (CCC) of 0.98 and a Mean Absolute Error (MAE) of 3.96 mm. Conversely, widest cusp-to-cusp measurements exhibited substantially lower agreement (CCC 0.80) and significantly higher error rates (MAE 16.88 mm), consistently overestimating the perimeter. This led to the upward reclassification of 10.0% (5/50) and 16.0% (8/50) of patients across the 40 and 45 mm guideline thresholds, respectively. Conclusion: Cusp-to-cusp measurement techniques recommended by ESC and EACTS produce systematically divergent aortic root dimensions, resulting in significant patient reclassification across clinical thresholds. Although the middle measurement aligns more closely with the traced anatomical perimeter, the principal finding of this study is that guideline choice fundamentally alters patient categorization. Standardization of aortic root measurement conventions is essential to ensure consistent international care, improve research comparability, and reconcile historical risk thresholds with modern 3D imaging.
- 12 October 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Imaging Methods and Practice
- Vol. 4 (4)
Open AccessDivergent aortic root cusp-to-cusp measurement techniques on CMR: geometric implications and threshold reclassification
Objective: To evaluate discrepancies between current European guidelines (ESC vs. EACTS) regarding aortic root cusp-to-cusp measurements and assess their impact on risk stratification for prophylactic root replacement. Methods and results: A retrospective analysis was performed on a relative young cohort of 50 patients (mean age 42 years) who underwent non-contrast 3D cardiovascular magnetic resonance (CMR) imaging. We compared the widest-to-widest cusp measurements and the middle cusp-to-cusp measurements with each other and against a traced aortic root perimeter. The widest cusp-to-cusp measurement yielded systematically higher values compared to the middle measurement, showing a significant mean difference of 3.60 mm (P < 0.001). The middle measurement demonstrated better statistical agreement with the traced aortic root perimeter, achieving a Lin’s Concordance Correlation Coefficient (CCC) of 0.98 and a Mean Absolute Error (MAE) of 3.96 mm. Conversely, widest cusp-to-cusp measurements exhibited substantially lower agreement (CCC 0.80) and significantly higher error rates (MAE 16.88 mm), consistently overestimating the perimeter. This led to the upward reclassification of 10.0% (5/50) and 16.0% (8/50) of patients across the 40 and 45 mm guideline thresholds, respectively. Conclusion: Cusp-to-cusp measurement techniques recommended by ESC and EACTS produce systematically divergent aortic root dimensions, resulting in significant patient reclassification across clinical thresholds. Although the middle measurement aligns more closely with the traced anatomical perimeter, the principal finding of this study is that guideline choice fundamentally alters patient categorization. Standardization of aortic root measurement conventions is essential to ensure consistent international care, improve research comparability, and reconcile historical risk thresholds with modern 3D imaging.
- Open Access
- 25 September 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (11)
Distal Anastomotic New Entries After Acute Type A Aortic Dissection Surgery: A Retrospective Cohort Study
Objective: Distal anastomotic new entry (DANE) after acute type A aortic dissection repair may contribute to adverse downstream aortic remodelling. This study evaluated the incidence of postoperative DANE and its association with distal aortic growth, reintervention, and clinical outcomes. Design: All consecutive patients undergoing type A aortic dissection repair with residual downstream dissection (DeBakey I) between 2011 and 2024 were retrospectively analyzed. Computed tomography angiography was systematically reviewed for DANE using 2-plane distal anastomosis alignment. Longitudinal descending thoracic aortic maximum diameters were analyzed using linear mixed-effects models. Univariable logistic regression, Kaplan-Meier estimates, and Cox proportional hazards analyses were performed. Results: A total of 164 patients were included, of whom 77 (47.0%) had postoperative DANE. Patients with DANE demonstrated larger distal aortic diameters over time compared with patients without DANE, while baseline diameters were similar (37.6 vs 37.3, P = .77). At 3-5 years, estimated maximum descending thoracic aortic diameter was 51.6 vs 42.7 mm, respectively (P < .001). DANE was associated with ≥10-mm downstream aortic growth, ≥55-mm maximum diameter, and reintervention during 5-year follow-up (combined odds ratio 5.60 [2.48-12.65], P < .001). Overall survival did not differ between groups (hazard ratio 2.04 [0.80-5.18], P = .13). Cox regression demonstrated higher hazard ratios with DANE for reintervention (2.01 [1.01-3.97], P = .04) and reaching ≥55 mm aortic diameter (5.59 [2.33-13.42], P < .001). Conclusions and Relevance: DANE occurred frequently after type A aortic dissection repair and was strongly associated with accelerated downstream aortic growth and reintervention. Routine postoperative assessment and strategies aimed at preventing or treating DANE may improve long-term aortic outcomes.
- 25 September 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (11)
Open AccessDistal Anastomotic New Entries After Acute Type A Aortic Dissection Surgery: A Retrospective Cohort Study
Objective: Distal anastomotic new entry (DANE) after acute type A aortic dissection repair may contribute to adverse downstream aortic remodelling. This study evaluated the incidence of postoperative DANE and its association with distal aortic growth, reintervention, and clinical outcomes. Design: All consecutive patients undergoing type A aortic dissection repair with residual downstream dissection (DeBakey I) between 2011 and 2024 were retrospectively analyzed. Computed tomography angiography was systematically reviewed for DANE using 2-plane distal anastomosis alignment. Longitudinal descending thoracic aortic maximum diameters were analyzed using linear mixed-effects models. Univariable logistic regression, Kaplan-Meier estimates, and Cox proportional hazards analyses were performed. Results: A total of 164 patients were included, of whom 77 (47.0%) had postoperative DANE. Patients with DANE demonstrated larger distal aortic diameters over time compared with patients without DANE, while baseline diameters were similar (37.6 vs 37.3, P = .77). At 3-5 years, estimated maximum descending thoracic aortic diameter was 51.6 vs 42.7 mm, respectively (P < .001). DANE was associated with ≥10-mm downstream aortic growth, ≥55-mm maximum diameter, and reintervention during 5-year follow-up (combined odds ratio 5.60 [2.48-12.65], P < .001). Overall survival did not differ between groups (hazard ratio 2.04 [0.80-5.18], P = .13). Cox regression demonstrated higher hazard ratios with DANE for reintervention (2.01 [1.01-3.97], P = .04) and reaching ≥55 mm aortic diameter (5.59 [2.33-13.42], P < .001). Conclusions and Relevance: DANE occurred frequently after type A aortic dissection repair and was strongly associated with accelerated downstream aortic growth and reintervention. Routine postoperative assessment and strategies aimed at preventing or treating DANE may improve long-term aortic outcomes.
- Open Access
- 25 August 2026
- Published by Elsevier in JTCVS Open
- Vol. 33
Quality of life after open descending thoracic and thoracoabdominal aortic repair: A prospective cohort study
- 25 August 2026
- Published by Elsevier in JTCVS Open
- Vol. 33
Open AccessQuality of life after open descending thoracic and thoracoabdominal aortic repair: A prospective cohort study
- 2 June 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (22) , 1761-1780
Standardized End Point Definitions for Clinical Trials in Thoracic Aortic Repair: A Consensus Report From the ARCH–Academic Research Consortium
Innovation in the treatment of ascending aorta and arch pathology with novel catheter-based and hybrid procedures has driven the need for a strategy to guide their safe application. The ARCH-ARC (Aortic Arch Academic Research Consortium) was established to pragmatically develop consistent clinical end points and to standardize definitions for use in studies of these new technologies. The ARCH-ARC team, consisting of independent international specialists in cardiac surgery, vascular surgery, vascular medicine, cardiology, neurology, radiology, and clinical trials, along with US Food and Drug Administration, industry, and contract research organization representatives, held virtual meetings from 2021 to 2025. Consensus was used to identify appropriate clinical end points and to standardize definitions of end points for endovascular, hybrid, and open surgical procedures in clinical trials in the ascending aorta and arch. Drawing on previous ARC work in cardiac, neurological, renal, and bleeding end points, the ARCH-ARC focused on definitions and end points related to aortic arch–specific anatomy, pathology, and procedures and clinical, device, and imaging. The adoption of the ARCH-ARC consensus definitions and end points will provide a template for consistent adjudication and event reporting and facilitate comparisons of clinical research studies involving devices for ascending aorta and arch pathology.
- 2 June 2026
- Published by Wolters Kluwer Health in Circulation
- Vol. 153 (22) , 1761-1780
Standardized End Point Definitions for Clinical Trials in Thoracic Aortic Repair: A Consensus Report From the ARCH–Academic Research Consortium
Innovation in the treatment of ascending aorta and arch pathology with novel catheter-based and hybrid procedures has driven the need for a strategy to guide their safe application. The ARCH-ARC (Aortic Arch Academic Research Consortium) was established to pragmatically develop consistent clinical end points and to standardize definitions for use in studies of these new technologies. The ARCH-ARC team, consisting of independent international specialists in cardiac surgery, vascular surgery, vascular medicine, cardiology, neurology, radiology, and clinical trials, along with US Food and Drug Administration, industry, and contract research organization representatives, held virtual meetings from 2021 to 2025. Consensus was used to identify appropriate clinical end points and to standardize definitions of end points for endovascular, hybrid, and open surgical procedures in clinical trials in the ascending aorta and arch. Drawing on previous ARC work in cardiac, neurological, renal, and bleeding end points, the ARCH-ARC focused on definitions and end points related to aortic arch–specific anatomy, pathology, and procedures and clinical, device, and imaging. The adoption of the ARCH-ARC consensus definitions and end points will provide a template for consistent adjudication and event reporting and facilitate comparisons of clinical research studies involving devices for ascending aorta and arch pathology.
- Open Access
- 13 January 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (2)
The GERAADA Risk Score for Early Mortality After Surgery for Acute Type A Aortic Dissection: An External Validation in the Dutch Setting
Objectives: Acute type A aortic dissection (ATAAD) carries high mortality, with emergency surgery being the cornerstone of treatment. The German Registry for Acute Type A Aortic Dissection (GERAADA)-score is advocated in guidelines to predict 30-day mortality after ATAAD surgery. This study investigates its performance in a Dutch cohort, with an emphasis on malperfusion definitions, age groups, and sex. Methods: Adults undergoing emergency surgery for ATAAD at 5 Dutch centres (2007-2024) were included in a multicentre database. External validation of the GERAADA-score was performed with these data, using discrimination (area under the curve [AUC]) and calibration (Brier score, Hosmer-Lemeshow test, and calibration plots). A logistic regression with GERAADA variables was fitted on the study population, and assumptions were checked. Subgroup analyses were conducted based on sex, age groups, and malperfusion definitions (including imaging and clinical definitions). Results: A total of 1,146 patients underwent emergency surgery for ATAAD. Observed early mortality was 16.9% (n = 194). Of 1,130 patients included in the external validation cohort, 92.2% had low-intermediate risk (GERAADA-score ≤ 30%). The GERAADA-score showed moderate discrimination (AUC = 0.649, 95% confidence interval = 0.604-0.694), with a higher AUC for younger patients (50-59 years). The malperfusion definition including ischaemia confirmed by imaging showed the best discriminative power. Calibration was good (Hosmer-Lemeshow, P = .754, Brier score = 0.131). Logistic regression identified age, catecholamine use, ventilation support, and coronary and peripheral malperfusion as independent risk factors for 30-day mortality, with signs of multicollinearity between preoperative catecholamine use and resuscitation. Conclusions: In the Dutch setting, the GERAADA-score demonstrated moderate discriminative power and good calibration across relevant subgroups. Adaptations of the GERAADA-score, including conducting a haemodynamic instability variable, may be considered to avoid redundant predictions and boost reproducibility.
- 13 January 2026
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (2)
Open AccessThe GERAADA Risk Score for Early Mortality After Surgery for Acute Type A Aortic Dissection: An External Validation in the Dutch Setting
Objectives: Acute type A aortic dissection (ATAAD) carries high mortality, with emergency surgery being the cornerstone of treatment. The German Registry for Acute Type A Aortic Dissection (GERAADA)-score is advocated in guidelines to predict 30-day mortality after ATAAD surgery. This study investigates its performance in a Dutch cohort, with an emphasis on malperfusion definitions, age groups, and sex. Methods: Adults undergoing emergency surgery for ATAAD at 5 Dutch centres (2007-2024) were included in a multicentre database. External validation of the GERAADA-score was performed with these data, using discrimination (area under the curve [AUC]) and calibration (Brier score, Hosmer-Lemeshow test, and calibration plots). A logistic regression with GERAADA variables was fitted on the study population, and assumptions were checked. Subgroup analyses were conducted based on sex, age groups, and malperfusion definitions (including imaging and clinical definitions). Results: A total of 1,146 patients underwent emergency surgery for ATAAD. Observed early mortality was 16.9% (n = 194). Of 1,130 patients included in the external validation cohort, 92.2% had low-intermediate risk (GERAADA-score ≤ 30%). The GERAADA-score showed moderate discrimination (AUC = 0.649, 95% confidence interval = 0.604-0.694), with a higher AUC for younger patients (50-59 years). The malperfusion definition including ischaemia confirmed by imaging showed the best discriminative power. Calibration was good (Hosmer-Lemeshow, P = .754, Brier score = 0.131). Logistic regression identified age, catecholamine use, ventilation support, and coronary and peripheral malperfusion as independent risk factors for 30-day mortality, with signs of multicollinearity between preoperative catecholamine use and resuscitation. Conclusions: In the Dutch setting, the GERAADA-score demonstrated moderate discriminative power and good calibration across relevant subgroups. Adaptations of the GERAADA-score, including conducting a haemodynamic instability variable, may be considered to avoid redundant predictions and boost reproducibility.
- Open Access
- 9 January 2026
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
Prediction of Thoracic Endovascular Aortic Repair Intervention: Proof of Concept using Digital Twin Technology
- 9 January 2026
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
Open AccessPrediction of Thoracic Endovascular Aortic Repair Intervention: Proof of Concept using Digital Twin Technology
- Open Access
- 26 December 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (1)
An Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis
Objectives: To report an initial experience with a novel off-the-shelf single branched thoracic aortic stent graft preserving various aortic arch vessels. Methods: Our study is a retrospective cohort analysis of the largest European case series to date. We treated twenty patients for various aortic arch and descending pathology in the year 2024 and 2025. Results: Twenty patients underwent successful implantation of the thoracic branched endoprosthesis (TBE) in the aortic arch and descending thoracic aorta. The sidebranch was applied to preserve the left subclavian artery in 17 patients, the innominate artery in two and the left carotid artery in one patient. Patients were treated for saccular arch aneurysms, chronic type B dissections with progressive dilatation, type 1a endoleaks after TEVAR, degenerative thoracic aneurysms, localized type A dissections or a first stage Crawford type II thoraco-abdominal aneurysm repair followed by a subsequent visceral branched endoprosthesis. The median follow-up period was six (1-12) months and technical results were satisfying. All TBE stentgrafts were implanted in the desired position with a patent branch on computed tomography angiography (CT-A) scan six weeks postoperatively. There was no in-hospital or 30-day mortality. Unfortunately, two patients suddenly died seven and eight weeks postoperatively of unknown causes. CT-A scan at six weeks showed no abnormalities concerning the aorta or TBE in both patients. Conclusions: The present study demonstrates satisfying technical results with the GORE TBE which was successfully implanted for multiple indications of aortic arch or descending pathology. Longer follow-up and larger series are needed for verification.
- 26 December 2025
- Published by Oxford University Press (OUP) in Interdisciplinary CardioVascular and Thoracic Surgery
- Vol. 41 (1)
Open AccessAn Initial Single-Center European Experience with the Gore Thoracic Branch Endoprosthesis
Objectives: To report an initial experience with a novel off-the-shelf single branched thoracic aortic stent graft preserving various aortic arch vessels. Methods: Our study is a retrospective cohort analysis of the largest European case series to date. We treated twenty patients for various aortic arch and descending pathology in the year 2024 and 2025. Results: Twenty patients underwent successful implantation of the thoracic branched endoprosthesis (TBE) in the aortic arch and descending thoracic aorta. The sidebranch was applied to preserve the left subclavian artery in 17 patients, the innominate artery in two and the left carotid artery in one patient. Patients were treated for saccular arch aneurysms, chronic type B dissections with progressive dilatation, type 1a endoleaks after TEVAR, degenerative thoracic aneurysms, localized type A dissections or a first stage Crawford type II thoraco-abdominal aneurysm repair followed by a subsequent visceral branched endoprosthesis. The median follow-up period was six (1-12) months and technical results were satisfying. All TBE stentgrafts were implanted in the desired position with a patent branch on computed tomography angiography (CT-A) scan six weeks postoperatively. There was no in-hospital or 30-day mortality. Unfortunately, two patients suddenly died seven and eight weeks postoperatively of unknown causes. CT-A scan at six weeks showed no abnormalities concerning the aorta or TBE in both patients. Conclusions: The present study demonstrates satisfying technical results with the GORE TBE which was successfully implanted for multiple indications of aortic arch or descending pathology. Longer follow-up and larger series are needed for verification.
- Open Access
- 12 December 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (4) , 669-677
Open Surgery of the Descending Thoracic Aorta in the Endovascular Era: A Single Centre Experience
- 12 December 2025
- Published by Elsevier in European Journal of Vascular and Endovascular Surgery
- Vol. 72 (4) , 669-677
Open AccessOpen Surgery of the Descending Thoracic Aorta in the Endovascular Era: A Single Centre Experience
- Open Access
- 28 August 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (6) , 101961
Endovascular repair of two acute type A aortic dissections with Gore thoracic branch endoprosthesis
- 28 August 2025
- Published by Elsevier in Journal of Vascular Surgery Cases, Innovations and Techniques
- Vol. 11 (6) , 101961
Open AccessEndovascular repair of two acute type A aortic dissections with Gore thoracic branch endoprosthesis