RSRajendra Kumar Sharma

Rajendra Kumar Sharma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rajendra Kumar Sharma has a total of 16 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Spectroscopic insights into structural and electronic modifications in Ce0.8Zr0.2O2 under low-energy ion irradiation

    by Vivek Kumar, Yogendar Singh, Avaneesh Pandey, Saurabh Kumar Sharma, Rajendra Kumar Sharma, Vinita Grover, P. K. Kulriya

    This study presents a comprehensive spectroscopic investigation of defect formation and structural stability in polycrystalline Ce0.8Zr0.2O2 subjected to 1.75 MeV Xe5+ ion irradiation up to a fluence of 1 × 1017 ions/cm2. Building on our earlier structural analysis of Xe-induced defects in Ce0.8Zr0.2O2, we employ Raman spectroscopy, synchrotron-based x-ray photoelectron spectroscopy (XPS), UV–visible diffuse reflectance spectroscopy (UV–Vis DRS), and photoluminescence (PL) to elucidate atomic-scale structural and electronic modifications. Raman analysis reveals the emergence of Ce3+ and oxygen-vacancy-induced distortions, evident from peak broadening and shifts associated with B1g, F2g, and LO phonon modes. The extent of structural disorder is quantified from Raman intensity ratios and FWHM broadening, revealing damage region diameters of ∼0.31 ± 0.03 and ∼0.22 ± 0.03 nm, respectively. XPS confirms the partial reduction of Ce4+ to Ce3+ and Zr4+ to Zr3+, along with oxygen-vacancy formation that contributes to lattice relaxation and stabilization of the fluorite structure. UV–Vis DRS measurements show a decrease in optical bandgap from 3.37 to 2.71 eV and an increase in Urbach energy from 1.09 to 2.33 eV, indicating enhanced electronic disorder. PL intensity is quenched upon irradiation due to increased non-radiative recombination through defect centers. These findings provide a coherent spectroscopic framework to understand irradiation-driven redox and defect processes in Ce0.8Zr0.2O2. Its retained crystallinity while accommodating high defect densities highlights its promise as a radiation-tolerant matrix for advanced nuclear and extreme-environment applications.

  • First result of photoabsorption spectroscopic studies beamline (PASS, BL-07) installed on Indus-1 synchrotron source

    by R. K. Sharma, Jaspreet Singh, Uday Sule, Pradeep R, J. Jagannath

    The photoabsorption spectroscopic studies (PASS) beamline (PASS-BL07), installed at a bending magnet 450 MeV, 100 mA Indus-1 synchrotron source (India), is capable of performing photoabsorption studies in the vacuum ultraviolet to soft x-ray range of thin films and solid samples. The beamline covers an energy range of 55 eV–840 eV by an in-house developed SX-700 type plane grating monochromator. This energy range will cover the absorption spectra of low Z-elements like C, N, and O as well as the L and M threshold of 3d elements such as Ti, V, S, etc. The beamline will be significantly used for studying organic semiconductors, graphene, etc. In this article, the design details of the beamline and some of the recent scientific results have been presented.

  • HAXPES beamline PES-BL14 at the Indus-2 synchrotron radiation source

    by Jagannath, U. K. Goutam, R. K. Sharma, J. Singh, K. Dutta, U. S. Sule, R. Pradeep, S. C. Gadkari

    The Hard X-ray Photo-Electron Spectroscopy (HAXPES) beamline (PES-BL14), installed at the 1.5 T bending-magnet port at the Indian synchrotron (Indus-2), is now available to users. The beamline can be used for X-ray photo-emission electron spectroscopy measurements on solid samples. The PES beamline has an excitation energy range from 3 keV to 15 keV for increased bulk sensitivity. An in-house-developed double-crystal monochromator [Si (111)] and a platinum-coated X-ray mirror are used for the beam monochromatization and manipulation, respectively. This beamline is equipped with a high-energy (up to 15 keV) high-resolution (meV) hemispherical analyzer with a microchannel plate and CCD detector system with SpecsLab Prodigy and CasaXPS software. Additional user facilities include a thin-film laboratory for sample preparation and a workstation for on-site data processing. In this article, the design details of the beamline, other facilities and some recent scientific results are described.