Max Bruker
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Max Bruker has a total of 219 co-authors. Here are the top co-authors by number of shared publications:
- Joseph Grames
Thomas Jefferson National Accelerator Facility (TJNAF), Newport News, VA (United States)
4 shared publications - Andrew Hutton
Thomas Jefferson National Accelerator Facility
3 shared publications K. Jordan
Thomas Jefferson National Accelerator Facility
3 shared publications- Lijun Mao
Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou, China
3 shared publications T. Powers
Thomas Jefferson National Accelerator Facility
3 shared publicationsThomas Jefferson National Accelerator Facility (Tjnaf)
3 shared publications
Latest Publications
- Top Cited PapersOpen Access
- 15 August 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (8) , 084802
The Continuous Electron Beam Accelerator Facility at 12 GeV
This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix.- 15 August 2024
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 27 (8) , 084802
Top Cited PapersOpen AccessThe Continuous Electron Beam Accelerator Facility at 12 GeV
This review paper describes the energy-upgraded Continuous Electron Beam Accelerator Facility (CEBAF) accelerator. This superconducting linac has achieved 12 GeV beam energy by adding 11 new high-performance cryomodules containing 88 superconducting cavities that have operated cw at an average accelerating gradient of . After reviewing the attributes and performance of the previous 6 GeV CEBAF accelerator, we discuss the upgraded CEBAF accelerator system in detail with particular attention paid to the new beam acceleration systems. In addition to doubling the acceleration in each linac, the upgrade included improving the beam recirculation magnets, adding more helium cooling capacity to allow the newly installed modules to run cold, adding a new experimental hall, and improving numerous other accelerator components. We review several of the techniques deployed to operate and analyze the accelerator performance and document system operating experience and performance. In the final portion of the document, we present much of the current planning regarding projects to improve accelerator performance and enhance operating margins, and our plans for ensuring CEBAF operates reliably into the future. For the benefit of potential users of CEBAF, the performance and quality measures for the beam delivered to each of the experimental halls are summarized in the Appendix. - Open Access
- 30 July 2024
- Published by Sissa Medialab Srl
- Vol. 456, 210
CEBAF injector at 200 kV: K-Long bunch charge with spin flipper OFF/ON
The forthcoming K-Long experiment in Jefferson Lab’s Hall D presents distinct beam requirements, marked by a notably low bunch repetition rate and an unusually high bunch charge.Furthermore, the Continuous Electron Beam Accelerator Facility (CEBAF) Injector requires a parity quality beam for experiments such as the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER). In this study, to prepare for the upcoming K-Long experiment, using the optimized settings of the magnetic elements and RF amplitude and phases, we conducted simulations covering a range of bunch charge beams, from low to high specifications, while considering concurrent operations across all four Halls at CEBAF. Through these simulations, we systematically analyzed beam transmission as well as the transverse and longitudinal beam characteristics, examining the impact of Spin Flipper settings in both ON and OFF states.
- 30 July 2024
- Published by Sissa Medialab Srl
- Vol. 456, 210
Open AccessCEBAF injector at 200 kV: K-Long bunch charge with spin flipper OFF/ON
The forthcoming K-Long experiment in Jefferson Lab’s Hall D presents distinct beam requirements, marked by a notably low bunch repetition rate and an unusually high bunch charge.Furthermore, the Continuous Electron Beam Accelerator Facility (CEBAF) Injector requires a parity quality beam for experiments such as the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER). In this study, to prepare for the upcoming K-Long experiment, using the optimized settings of the magnetic elements and RF amplitude and phases, we conducted simulations covering a range of bunch charge beams, from low to high specifications, while considering concurrent operations across all four Halls at CEBAF. Through these simulations, we systematically analyzed beam transmission as well as the transverse and longitudinal beam characteristics, examining the impact of Spin Flipper settings in both ON and OFF states.
- Open Access
- 6 March 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1062
A Compton transmission polarimeter for DC and SRF electron photo-injectors
- 6 March 2024
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1062
Open AccessA Compton transmission polarimeter for DC and SRF electron photo-injectors
- Open Access
- 20 April 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (4) , 042803
Coherent Smith-Purcell radiation for minimally invasive bunch length measurement at the subpicosecond time scale
We have designed a tool to measure the bunch length of an electron beam in a minimally invasive way by means of coherent Smith-Purcell radiation (SPR). The technique has been employed successfully at a test apparatus for the Mainz Energy-recovery Superconducting Accelerator MESA, demonstrating it is possible to determine the bunch length while losing less than 0.6% of the electron beam. The impact of the space charge on the bunch length can be reduced while tuning the longitudinal bunch preparation system during a live measurement at beam currents up to 1 mA. Doing so, RMS bunch lengths of can be achieved in a typical operating mode of the low-energy beam transport system of MESA. In addition to the bunch length measurements, typical properties of the generated SPR are demonstrated.- 20 April 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (4) , 042803
Open AccessCoherent Smith-Purcell radiation for minimally invasive bunch length measurement at the subpicosecond time scale
We have designed a tool to measure the bunch length of an electron beam in a minimally invasive way by means of coherent Smith-Purcell radiation (SPR). The technique has been employed successfully at a test apparatus for the Mainz Energy-recovery Superconducting Accelerator MESA, demonstrating it is possible to determine the bunch length while losing less than 0.6% of the electron beam. The impact of the space charge on the bunch length can be reduced while tuning the longitudinal bunch preparation system during a live measurement at beam currents up to 1 mA. Doing so, RMS bunch lengths of can be achieved in a typical operating mode of the low-energy beam transport system of MESA. In addition to the bunch length measurements, typical properties of the generated SPR are demonstrated. - Open Access
- 6 January 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (1) , 012801
Demonstration of electron cooling using a pulsed beam from an electrostatic electron cooler
Cooling of hadron beams is critically important in the next generation of hadron storage rings for delivery of unprecedented performance. One such application is the electron-ion collider presently under development in the US. The desire to develop electron coolers for operation at much higher energies than previously achieved necessitates the use of radio-frequency (rf) fields for acceleration as opposed to the conventional, electrostatic approach. While electron cooling is a mature technology at low energy utilizing a dc beam, rf acceleration requires the cooling beam to be bunched, thus extending the parameter space to an unexplored territory. It is important to experimentally demonstrate the feasibility of cooling with electron bunches and further investigate how the relative time structure of the two beams affects the cooling properties; thus, a set of four pulsed-beam cooling experiments was carried out by a collaboration of Jefferson Lab and Institute of Modern Physics (IMP). The experiments have successfully demonstrated cooling with a beam of electron bunches in both the longitudinal and transverse directions for the first time. We have measured the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate that if the synchronization can be accurately maintained, the dynamics are not adversely affected by the change in time structure.
- 6 January 2021
- Published by American Physical Society (APS) in Physical Review Accelerators and Beams
- Vol. 24 (1) , 012801
Open AccessDemonstration of electron cooling using a pulsed beam from an electrostatic electron cooler
Cooling of hadron beams is critically important in the next generation of hadron storage rings for delivery of unprecedented performance. One such application is the electron-ion collider presently under development in the US. The desire to develop electron coolers for operation at much higher energies than previously achieved necessitates the use of radio-frequency (rf) fields for acceleration as opposed to the conventional, electrostatic approach. While electron cooling is a mature technology at low energy utilizing a dc beam, rf acceleration requires the cooling beam to be bunched, thus extending the parameter space to an unexplored territory. It is important to experimentally demonstrate the feasibility of cooling with electron bunches and further investigate how the relative time structure of the two beams affects the cooling properties; thus, a set of four pulsed-beam cooling experiments was carried out by a collaboration of Jefferson Lab and Institute of Modern Physics (IMP). The experiments have successfully demonstrated cooling with a beam of electron bunches in both the longitudinal and transverse directions for the first time. We have measured the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate that if the synchronization can be accurately maintained, the dynamics are not adversely affected by the change in time structure.
- Open Access
Demonstration of electron cooling using a pulsed beam from an electrostatic electron cooler
Cooling of hadron beams is critically important in the next generation of hadron storage rings for delivery of unprecedented performance. One such application is the electron-ion collider presently under development in the US. The desire to develop electron coolers for operation at much higher energies than previously achieved necessitates the use of radio-frequency (RF) fields for acceleration as opposed to the conventional, electrostatic approach. While electron cooling is a mature technology at low energy utilizing a DC beam, RF acceleration requires the cooling beam to be bunched, thus extending the parameter space to an unexplored territory. It is important to experimentally demonstrate the feasibility of cooling with electron bunches and further investigate how the relative time structure of the two beams affects the cooling properties; thus, a set of four pulsed-beam cooling experiments was carried out by a collaboration of Jefferson Lab and Institute of Modern Physics (IMP). The experiments have successfully demonstrated cooling with a beam of electron bunches in both the longitudinal and transverse directions for the first time. We have measured the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate that if the synchronization can be accurately maintained, the dynamics are not adversely affected by the change in time structure.
Open AccessDemonstration of electron cooling using a pulsed beam from an electrostatic electron cooler
Cooling of hadron beams is critically important in the next generation of hadron storage rings for delivery of unprecedented performance. One such application is the electron-ion collider presently under development in the US. The desire to develop electron coolers for operation at much higher energies than previously achieved necessitates the use of radio-frequency (RF) fields for acceleration as opposed to the conventional, electrostatic approach. While electron cooling is a mature technology at low energy utilizing a DC beam, RF acceleration requires the cooling beam to be bunched, thus extending the parameter space to an unexplored territory. It is important to experimentally demonstrate the feasibility of cooling with electron bunches and further investigate how the relative time structure of the two beams affects the cooling properties; thus, a set of four pulsed-beam cooling experiments was carried out by a collaboration of Jefferson Lab and Institute of Modern Physics (IMP). The experiments have successfully demonstrated cooling with a beam of electron bunches in both the longitudinal and transverse directions for the first time. We have measured the effect of the electron bunch length and longitudinal ion focusing strength on the temporal evolution of the longitudinal and transverse ion beam profile and demonstrate that if the synchronization can be accurately maintained, the dynamics are not adversely affected by the change in time structure.