Lingxiao Shen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lingxiao Shen has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
- Gang Zhao
Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei China
8 shared publications Yu Huang
Clinic Medical College of Anhui Medical University, Hefei 230601, China
5 shared publicationsJi Peng
Department of Mechanical Engineering, University of Washington, Seattle, WA 98195, USA
3 shared publicationsDayong Gao
Department of Mechanical Engineering Center for Cyro-Biomedical Engineering and Artificial Organs University of Washington Seattle WA 98195 USA
2 shared publicationsFrank Liu Gao
School of Public Affairs, University of Science and Technology of China, Hefei, China
2 shared publicationsJianye Wang
Anhui Provincial Engineering Technology Research Center for Biopreservation and Artificial Organs, Hefei, China; Center for Reproductive Medicine, Obstetrics and Gynecology, The First Affiliated Hospital of Anhui Medical University, Hefei, China
2 shared publications
Latest Publications
- 16 November 2022
- Published by Wiley in Advanced Engineering Materials
- Vol. 24 (11)
Combining Cooling Enhancement and Trehalose Dehydration to Enable Scalable Volume Cryopreservation of Red Blood Cells with Low Concentration of Glycerol
- 16 November 2022
- Published by Wiley in Advanced Engineering Materials
- Vol. 24 (11)
Combining Cooling Enhancement and Trehalose Dehydration to Enable Scalable Volume Cryopreservation of Red Blood Cells with Low Concentration of Glycerol
- 4 August 2022
- Published by Wiley in Advanced Engineering Materials
- Vol. 24 (11)
Combining Cooling Enhancement and Trehalose Dehydration to Enable Scalable Volume Cryopreservation of Red Blood Cells with Low Concentration of Glycerol
Enhancing the cooling rate is often an alternative to increasing concentrations of cryoprotectants to inhibit harmful ice growth during freezing. Processing cell suspensions as dispersed droplets can improve the cooling rate but carries the risk of difficult collection and contamination. As the most readily available cells, human red blood cells (RBCs) are used to test the feasibility of advanced cryopreservation techniques. Herein, a feasible and straightforward method for scalable cryopreservation of RBCs is presented. This method can be easily realized by selecting 5 × 6 mm polytetrafluoroethylene (PTFE) tubes with better cooling capacity and applying the trehalose dehydration technique. Finally, the highest freeze‐thaw recovery rate in the available literature with trehalose alone (93.87% with 0.4 m Tre) and freezing the volume of RBCs from 2 to 20 mL with a higher freeze‐thaw recovery of 95–96% after adding 5% glycerol (0.4 m Tre + 5% Gly) are achieved. A two‐step washing method is also evaluated to remove the cryoprotectants, allowing the process could be completed within 20 min after thawing. Furthermore, the functional expression of postwash RBCs after cryopreservation is examined and all results show that this scalable volume cryopreservation method can be extended to current clinical RBC cryopreservation.
- 4 August 2022
- Published by Wiley in Advanced Engineering Materials
- Vol. 24 (11)
Combining Cooling Enhancement and Trehalose Dehydration to Enable Scalable Volume Cryopreservation of Red Blood Cells with Low Concentration of Glycerol
Enhancing the cooling rate is often an alternative to increasing concentrations of cryoprotectants to inhibit harmful ice growth during freezing. Processing cell suspensions as dispersed droplets can improve the cooling rate but carries the risk of difficult collection and contamination. As the most readily available cells, human red blood cells (RBCs) are used to test the feasibility of advanced cryopreservation techniques. Herein, a feasible and straightforward method for scalable cryopreservation of RBCs is presented. This method can be easily realized by selecting 5 × 6 mm polytetrafluoroethylene (PTFE) tubes with better cooling capacity and applying the trehalose dehydration technique. Finally, the highest freeze‐thaw recovery rate in the available literature with trehalose alone (93.87% with 0.4 m Tre) and freezing the volume of RBCs from 2 to 20 mL with a higher freeze‐thaw recovery of 95–96% after adding 5% glycerol (0.4 m Tre + 5% Gly) are achieved. A two‐step washing method is also evaluated to remove the cryoprotectants, allowing the process could be completed within 20 min after thawing. Furthermore, the functional expression of postwash RBCs after cryopreservation is examined and all results show that this scalable volume cryopreservation method can be extended to current clinical RBC cryopreservation.
- 8 December 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 9 (2) , 295-306
Fine-tuned dehydration by trehalose enables the cryopreservation of RBCs with unusually low concentrations of glycerol
The clinical transfusion of red blood cells (RBCs) has provided the greatest number of cryobiology applications in the case of rare blood groups and antibody problems, as well as civil and military disasters. The main technical difficulty with the current clinical technique is the removal of high concentration glycerol (20% or 40%) after thawing. Reducing the probability of intracellular ice formation (IIF) as well as preventing the solution effect are crucial to ensure RBCs avoid cryoinjury. Here, the non-permeating cryoprotectant trehalose was used to dehydrate RBCs before freezing. Furthermore, with the substitution of the low concentration glycerol (5% or 7.5%) for the intracellular remaining water, the bulk of RBCs were successfully cryopreserved to obtain a nearly 95% high survival rate with rapid cooling via EP tubes. Additionally, the washed RBCs after cryopreservation maintained their morphology, deformability, ATP, and 2-3 DPG levels, and all of them met the clinical standards for transfusion safety. Moreover, the whole addition and washing process was simple and easy to operate and could be completed within 30 min, which is crucial for emergency uses. This method will provide more potential for current clinical RBCs cryopreservation practices.
- 8 December 2020
- Published by Royal Society of Chemistry (RSC) in Journal of Materials Chemistry B
- Vol. 9 (2) , 295-306
Fine-tuned dehydration by trehalose enables the cryopreservation of RBCs with unusually low concentrations of glycerol
The clinical transfusion of red blood cells (RBCs) has provided the greatest number of cryobiology applications in the case of rare blood groups and antibody problems, as well as civil and military disasters. The main technical difficulty with the current clinical technique is the removal of high concentration glycerol (20% or 40%) after thawing. Reducing the probability of intracellular ice formation (IIF) as well as preventing the solution effect are crucial to ensure RBCs avoid cryoinjury. Here, the non-permeating cryoprotectant trehalose was used to dehydrate RBCs before freezing. Furthermore, with the substitution of the low concentration glycerol (5% or 7.5%) for the intracellular remaining water, the bulk of RBCs were successfully cryopreserved to obtain a nearly 95% high survival rate with rapid cooling via EP tubes. Additionally, the washed RBCs after cryopreservation maintained their morphology, deformability, ATP, and 2-3 DPG levels, and all of them met the clinical standards for transfusion safety. Moreover, the whole addition and washing process was simple and easy to operate and could be completed within 30 min, which is crucial for emergency uses. This method will provide more potential for current clinical RBCs cryopreservation practices.
- 1 October 2020
- Published by Elsevier in Journal of Thermal Biology
- Vol. 93, 102689
Water-transport and intracellular ice formation of human adipose-derived stem cells during freezing
- 1 October 2020
- Published by Elsevier in Journal of Thermal Biology
- Vol. 93, 102689
Water-transport and intracellular ice formation of human adipose-derived stem cells during freezing
- 1 October 2020
- Published by Elsevier in Applied Acoustics
- Vol. 167
A multi-emitter ultrasonic flatness detecting device
- 1 October 2020
- Published by Elsevier in Applied Acoustics
- Vol. 167
A multi-emitter ultrasonic flatness detecting device
- 12 June 2020
- Published by SAGE Publications in Biopreservation and Biobanking
- Vol. 18 (3) , 228-234
Hydrogel Microfiber Encapsulation Enhances Cryopreservation of Human Red Blood Cells with Low Concentrations of Glycerol
Cryopreservation of red blood cells (RBCs) has been studied as a typical example of cryobiology methodology. To date, a mature and long-term cryopreservation process for RBCs has been developed, which has the weakness of complicated procedures due to high concentrations of glycerol (Gly). Therefore, it is still a research focus to find a new method for cryopreservation of RBCs to reduce the concentrations of cryoprotectants (CPAs). In this study, alginate hydrogels, which have been widely used in preservation research, were selected because of their advantages such as lower cost, cytocompatibility, and crosslinking occurring under mild conditions. With a variety of CPA solutions, the RBC recovery with the cryopreservation of RBCs and RBC-laden hydrogel microfibers was compared in different situations. It was found that hydrogel microfiber encapsulation enhances cryopreservation of human RBCs with low concentrations of CPAs. And Gly can be removed by washing directly with a 0.9% sodium chloride solution. This study validated the feasibility of cryopreservation of RBC-laden hydrogel microfibers. It may provide a new and evolving direction for reducing the concentrations of CPAs used in the preservation of RBCs.
- 12 June 2020
- Published by SAGE Publications in Biopreservation and Biobanking
- Vol. 18 (3) , 228-234
Hydrogel Microfiber Encapsulation Enhances Cryopreservation of Human Red Blood Cells with Low Concentrations of Glycerol
Cryopreservation of red blood cells (RBCs) has been studied as a typical example of cryobiology methodology. To date, a mature and long-term cryopreservation process for RBCs has been developed, which has the weakness of complicated procedures due to high concentrations of glycerol (Gly). Therefore, it is still a research focus to find a new method for cryopreservation of RBCs to reduce the concentrations of cryoprotectants (CPAs). In this study, alginate hydrogels, which have been widely used in preservation research, were selected because of their advantages such as lower cost, cytocompatibility, and crosslinking occurring under mild conditions. With a variety of CPA solutions, the RBC recovery with the cryopreservation of RBCs and RBC-laden hydrogel microfibers was compared in different situations. It was found that hydrogel microfiber encapsulation enhances cryopreservation of human RBCs with low concentrations of CPAs. And Gly can be removed by washing directly with a 0.9% sodium chloride solution. This study validated the feasibility of cryopreservation of RBC-laden hydrogel microfibers. It may provide a new and evolving direction for reducing the concentrations of CPAs used in the preservation of RBCs.
- 1 May 2019
- Vol. 40 (3) , 181-186
A SIMPLE AND RELIABLE COOLING APPROACH FOR THE CRYOPRESERVATION OF HEMATOPOIETIC STEM CELLS: THE PASSIVE COOLING RATE-CONTROLLED TECHNIQUE
BACKGROUND: Cryopreservation of hematopoietic stem cells (HSCs) has widely been used in stem cell transplantation and cellular therapy treating various human diseases. However, the current conventional cooling approach for the cryopreservation of HSCs has the following potential problems: (1) requirement of a very expensive computer-programmed liquid nitrogen freezer (LNF) for the cooling rate control, (2) a large consumption of liquid nitrogen, (3) periodic breakdown of the LNF due to the mechanical failure of the liquid nitrogen valves (i.e., magnetic-solenoid valves) inside the LNF, and (4) constant monitoring of the LNF operation during the HSCs cooling process. OBJECTIVE: To test and evaluate a simple and reliable approach for the cryopreservation of HSCs using the passive cooling technique. MATERIALS AND METHODS: A passive cooling-rate-controlled device (PCD) was developed and used to cryopreserve HSCs. The PCD is inexpensive, simple, and user-friendly, which needs only the minimum maintenance and no consumption of liquid nitrogen. The PCD was compared to the LNF for the cryopreservation of HSCs in the present study through experiments. The cell viability and functionality were evaluated after cryopreservation. RESULTS: In comparison with the LNF method, the PCD approach enabled high cell viability/survival, recovery rate, and functionality after cryopreservation processes. CONCLUSION: The PCD offers a cost-effective, simple, and reliable approach for the optimal cryopreservation of HSCs.
- 1 May 2019
- Vol. 40 (3) , 181-186
A SIMPLE AND RELIABLE COOLING APPROACH FOR THE CRYOPRESERVATION OF HEMATOPOIETIC STEM CELLS: THE PASSIVE COOLING RATE-CONTROLLED TECHNIQUE
BACKGROUND: Cryopreservation of hematopoietic stem cells (HSCs) has widely been used in stem cell transplantation and cellular therapy treating various human diseases. However, the current conventional cooling approach for the cryopreservation of HSCs has the following potential problems: (1) requirement of a very expensive computer-programmed liquid nitrogen freezer (LNF) for the cooling rate control, (2) a large consumption of liquid nitrogen, (3) periodic breakdown of the LNF due to the mechanical failure of the liquid nitrogen valves (i.e., magnetic-solenoid valves) inside the LNF, and (4) constant monitoring of the LNF operation during the HSCs cooling process. OBJECTIVE: To test and evaluate a simple and reliable approach for the cryopreservation of HSCs using the passive cooling technique. MATERIALS AND METHODS: A passive cooling-rate-controlled device (PCD) was developed and used to cryopreserve HSCs. The PCD is inexpensive, simple, and user-friendly, which needs only the minimum maintenance and no consumption of liquid nitrogen. The PCD was compared to the LNF for the cryopreservation of HSCs in the present study through experiments. The cell viability and functionality were evaluated after cryopreservation. RESULTS: In comparison with the LNF method, the PCD approach enabled high cell viability/survival, recovery rate, and functionality after cryopreservation processes. CONCLUSION: The PCD offers a cost-effective, simple, and reliable approach for the optimal cryopreservation of HSCs.
- 1 February 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 148, 768-776
Heat transfer analysis of a self-designed cooling rate controllable device and its application for cryopreservation of biological cells
- 1 February 2019
- Published by Elsevier in Applied Thermal Engineering
- Vol. 148, 768-776
Heat transfer analysis of a self-designed cooling rate controllable device and its application for cryopreservation of biological cells
- 1 October 2017
- Published by SAGE Publications in Biopreservation and Biobanking
- Vol. 15 (5) , 432-437
Improvement of a Simple and Cost-Effective Passive Cooling Rate-Controlled Device for Cell/Tissue Cryopreservation
The currently used commercial cooling-rate control device is the liquid nitrogen controlled rate freezer (LNF), which has some shortcomings such as high cost, high liquid nitrogen consumption, and potential operational risks in quality control. Based on thermophysical properties of new materials, we improved, manufactured, and optimized a reliable yet simple device named the “passive cooling rate-controlled device (PCD)” with real-time temperature tracing. In this study, using the improved PCD we cryopreserved human umbilical vein endothelial cells (HUVECs) and compared the results with a standard commercial CryoMed LNF. The temperature profiles and cooling rates of the HUVEC samples in a cryopreservation solution (with dimethyl sulfoxide [DMSO] in 10% v/v concentration) were measured and automatically recorded by the PCD during the controlled cooling process. This study and experimental results showed that the HUVEC survival rates after cryopreservation using the PCD have no significant difference from those using the CryoMed LNF and that the improved PCD is a user-friendly, reliable, and low-cost device to ensure an optimal slow cooling rate ranging from −0.5 to −1°C/min for the cryopreservation. Considering the advantages of low cost, durability, reliability, and no liquid nitrogen consumption for the cooling process, it is concluded that the PCD is an excellent controlled cooling device to achieve a desired optimal cooling rate for cell/tissue cryopreservation.
- 1 October 2017
- Published by SAGE Publications in Biopreservation and Biobanking
- Vol. 15 (5) , 432-437
Improvement of a Simple and Cost-Effective Passive Cooling Rate-Controlled Device for Cell/Tissue Cryopreservation
The currently used commercial cooling-rate control device is the liquid nitrogen controlled rate freezer (LNF), which has some shortcomings such as high cost, high liquid nitrogen consumption, and potential operational risks in quality control. Based on thermophysical properties of new materials, we improved, manufactured, and optimized a reliable yet simple device named the “passive cooling rate-controlled device (PCD)” with real-time temperature tracing. In this study, using the improved PCD we cryopreserved human umbilical vein endothelial cells (HUVECs) and compared the results with a standard commercial CryoMed LNF. The temperature profiles and cooling rates of the HUVEC samples in a cryopreservation solution (with dimethyl sulfoxide [DMSO] in 10% v/v concentration) were measured and automatically recorded by the PCD during the controlled cooling process. This study and experimental results showed that the HUVEC survival rates after cryopreservation using the PCD have no significant difference from those using the CryoMed LNF and that the improved PCD is a user-friendly, reliable, and low-cost device to ensure an optimal slow cooling rate ranging from −0.5 to −1°C/min for the cryopreservation. Considering the advantages of low cost, durability, reliability, and no liquid nitrogen consumption for the cooling process, it is concluded that the PCD is an excellent controlled cooling device to achieve a desired optimal cooling rate for cell/tissue cryopreservation.
- 1 October 2014
- Published by Elsevier in Cryobiology
- Vol. 69 (2) , 273-280
Effect of hydroxyapatite nanoparticles on osmotic responses of pig iliac endothelial cells
- 1 October 2014
- Published by Elsevier in Cryobiology
- Vol. 69 (2) , 273-280
Effect of hydroxyapatite nanoparticles on osmotic responses of pig iliac endothelial cells