MYMing-Li Ye

Ming-Li Ye

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ming-Li Ye has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Yan Zhu

    Department of Chemistry, Zhejiang University, Hangzhou 310028, China

    4 shared publications
  • Yong-Gang Zhao

    Department of Chemistry, Zhejiang University, Hangzhou 310027, China

    2 shared publications
  • Yun Zhang

    Department of Chemistry, Zhejiang University, Hangzhou 310027, China

    2 shared publications
  • Ban Cao

    Zhejiang Key Institute of Geosciences Hangzhou China

    1 shared publication
  • Fangfang Wu

    Zhejiang Key Laboratory for Protection Technology of High-Rise Operation, Zhejiang Huadian Equipment Testing Institute Co., Ltd, Hangzhou, Zhejiang 310015, China

    1 shared publication
  • Fangfang Wu

    National Engineering Laboratory for the Development of Southwestern Endangered, Medicinal Materials Guangxi Botanical Garden of Medicinal Plants Nanning P. R. China

    1 shared publication

Latest Publications

  • Differential Adaptation between Active Sites and Charge‐Transport Networks in Covalent Organic Frameworks for H 2 O 2 Photosynthesis

    by Xiaoling Gu, Mingli Ye, Hongyun Niu, Yali Shi, Ban Cao, Yaqi Cai

    Covalent organic frameworks (COFs) are promising photocatalysts for H 2 O 2 production. However, optimizing their electronic structure to enhance oxygen activation, charge separation, and transport remains challenging. Herein, a dual‐dimensional COF platform was constructed by integrating diazine isomers, pyridazine (Dz) and pyrazine (Pz), with tunable linkage chemistries (sp 2 c‐, mix‐, and imi‐linked), enabling decoupled regulation and systematic investigation of active‐site electronic environments and framework charge‐transport behavior. Experiments and theoretical calculations revealed that N ‐heterocyclic isomers primarily govern O 2 activation configurations and oxygen reduction reaction pathways, whereas linkage chemistry mainly regulates framework charge transport. More importantly, a previously unrecognized differential adaptation mechanism is revealed: in the intrinsically asymmetric Dz systems, highly conjugated sp 2 c linkages further enhance electron delocalization and transport, maximizing photocatalytic performance and enabling sp 2 c‐COF‐Dz to achieve the highest H 2 O 2 production rate (9270 µmol h −1 g −1 ); in contrast, in the Pz systems, mixed‐linkage architectures generate localized electron‐density gradients that compensate for insufficient site polarization by disrupting electronic symmetry, resulting in higher activity than the sp 2 c‐linked COF. These findings uncover a matching relationship between active‐site electronic structures and linkage‐mediated charge transport behavior, providing a site‐framework matching principle for the rational design of high‐performance COF photocatalysts.

  • Outdoor Air Quality Assessment of Catalyst Factory in Jiangbei, China

    by Mingli Ye, Xiaoxiao Dong, Yan Li, Ronghui Yuan, Wenhan Zhong

  • Open Access

    Determination of Organophosphorus Esters in Fall Protection Equipment by Accelerated Solvent Extraction and Solid-Phase Extraction Coupled with LC-MS/MS Detection

    by Haihong Li, Mingli Ye, Fangfang Wu, Xuyang Zhao, Lifeng Wang, Yili Wei, Shengyi Xie, Hairong Cui

    An analysis method was established to determine 14 organophosphorus ester (OPE) flame retardants in fall protection equipment by combining accelerated solvent extraction (ASE) and solid-phase extraction (SPE) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The ASE parameters were optimized as follows: static extraction with acetonitrile at 80°C for 5 min for two cycles. The combined extract was purified with the ENVI-18 cartridge before further analysis. A HILIC column was used to separate the OPEs using an acetonitrile/water mixture as the mobile phase with the detection by the electrospray ionization mass spectrometry, which was operated under the positive mode. Under optimized conditions, the limit of detection for the target OPEs ranged in 0.015–1.33 ng/g, with a spike recovery of 71.6%–114% and a relative standard deviation of 0.8%–11.2%. The developed method was used to analyze OPEs in fall protection equipment (safety helmets and ropes), where OPEs were all detectable. Safety ropes displayed a higher concentration of OPEs than ones in safety helmets, with the pollutants being mainly triphenyl phosphate, 2-ethylhexyl diphenyl phosphate (EHDPP), tri(2-ethylhexyl) phosphate, and tri-n-butyl phosphate in the range of 11.07 ng/g‒815.53 ng/g. The EHDPP was the dominant compound in safety helmets with the concentration from 26.84 to 95.29 ng/g, while the other OPEs in safety helmets were lower than 5.136 ng/g. The potential health and environmental risks of these fall protection equipment during their use and disposal call for further attention.


  • N-doped magnetic covalent organic frameworks for preconcentration of allergenic disperse dyes in textiles of fall protection equipment

    by Fang-Fang Wu, Qing-Yin Chen, Xiu-Juan Ma, Ting-Ting Li, Li-Feng Wang, Jing Hong, Ye-Hong Sheng, Ming-Li Ye, Yan Zhu

    A novel N-doped magnetic covalent organic framework (N-Mag-COF) has been synthesized. It has been evaluated in the magnetic dispersive solid phase extraction (Mag-dSPE) procedure for textiles of fall protection equipment prior to the analysis of allergenic disperse dyes by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). Compared with the matrix dilution procedure, much higher sensitivity of the analytical method has been achieved by the N-Mag-COF Mag-dSPE procedure. Furthermore, under the optimum conditions, the level of matrix effects can be dramatically reduced by the N-Mag-COF Mag-dSPE procedure with satisfactory recoveries in the range of 72.2–107%. The precision of the developed method was satisfactory, with relative standard deviations (RSDs) ranging from 2.3% to 7.1%. The limits of detection (LODs) and limits of quantification (LOQs) of 19 allergenic disperse dyes were in the range of 0.021–0.58 μg kg−1 and 0.069–1.91 μg kg−1, respectively. The developed analytical method was successfully applied to the analysis of 20 textile samples of fall protection equipment, in which disperse yellow 39 was found in two samples with concentrations at 0.081 μg kg−1 and 0.062 μg kg−1, respectively. The developed method can be applied to routine analyses for the determination of 19 allergenic disperse dyes in textiles of fall protection equipment.


  • Multiply-functionalized graphene oxide on-line pass-through cleanup for the fast determination of aconitum alkaloids in human plasma by LC-MS/MS

    by Shi-Wei He, Yun Zhang, Yong-Gang Zhao, Ming-Li Ye, Yan Zhu

    A novel ionic liquid coupled with nano-titania coated modified magnetic GO composites (IL-Ti-Mag-GO) has been synthesized. It has been evaluated in an on-line pass-through cleanup procedure for human plasma prior to the analysis of aconitum alkaloids, i.e., mesaconitine, hypaconitine and aconitine, by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). Under optimum conditions, the level of matrix effects can be dramatically reduced by the IL-Ti-Mag-GO on-line pass-through cleanup procedure, with satisfactory recoveries ranging from 81.2% to 108%. The trueness and precision of the developed method were satisfactory, with relative errors (REs) less than 19% and within- and between-run RSDs less than 7.0%. The limits of detection (LODs) and limits of quantification (LOQs) for aconitum alkaloids were in the range of 0.01–0.028 μg L−1 and 0.034–0.092 μg L−1, respectively. The developed analytical method has been successfully applied to the analysis of mesaconitine, hypaconitine and aconitine in two cases of suspected aconite poisoning, and the concentration of aconitine and hypaconitine in one sample was determined to be 0.076 μg L−1 and 0.069 μg L−1, respectively. The results demonstrate the applicability of the developed analytical method to clinical studies.