Jean Valdir Uchôa Teixeira
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jean Valdir Uchôa Teixeira has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
- Paulo Noronha Lisboa-Filho
São Paulo State University, Brazil
5 shared publications - Adriana Alencar Santos
Materials Science and Technology Program, Department of Physics, School of Sciences, UNESP—São Paulo State University, Bauru 17033-360, SP, Brazil
3 shared publications - Carlos Alberto Fonzar Pintão
Department of Physics, School of Sciences – FC, São Paulo State University, Bauru, Brazil
2 shared publications - Carlos Roberto Grandini
Laboratório de Anelasticidade e Biomateriais, UNESP—Universidade Estadual Paulista, Bauru 17033-360, SP, Brazil
2 shared publications Adriana A. Santos
UNESP - São Paulo State University, POSMAT, School of Science, Department of Physics, Bauru SP, Brazil
1 shared publication- Ana Paula Rosifini Alves Claro
School of Engineering and Sciences São Paulo State University (UNESP) Guaratinguetá Brazil
1 shared publication
Latest Publications
- Open Access
- 20 August 2026
- Published by Springer Nature in Journal of Molecular Modeling
- Vol. 32 (9) , 324
Zn2+-induced electronic polarization and local reactivity in melanin-like dopamine oligomers: a DFT study
Context: Melanin-like dopamine oligomers are promising biomaterials due to their biocompatibility and metal-chelating ability. In this work, Zn 2+ -chelated melanin-related structures were investigated to clarify the effects of metal coordination on their electronic structure. The results indicate that Zn 2+ coordination induces significant electronic polarization, modifies local reactivity patterns, and activates the coordination sites. The theoretical results are also consistent with available spectroscopic observations, providing molecular-level insight into the antibacterial behavior of these complexes and supporting the design of related bioactive materials. Methods: Density functional theory (DFT) calculations were performed for 5,6-dihydroxyindole (DHI), 5,6-dihydroxyindole-2-carboxylic acid (DHICA), and DHI-based oligomeric structures in different deprotonation states. Geometry optimizations and electronic-structure analyses were carried out using the B3LYP functional and 6-31G(d,p) basis set, including Grimme correction (GD3) and solvent effects through the polarizable continuum model (PCM) for water, as implemented in the Gaussian 16 software package. Local reactivity was investigated through condensed-to-atom Fukui indices (CAFIs) and molecular electrostatic potential (MEP) analyses. Zn 2+ coordination and complex stability were further evaluated using calculations performed with the ORCA computational package and complementary automated interaction site screening (aISS) analyses followed by geometry optimizations with the GFN2-xTB approach implemented in the xTB package.
- 20 August 2026
- Published by Springer Nature in Journal of Molecular Modeling
- Vol. 32 (9) , 324
Open AccessZn2+-induced electronic polarization and local reactivity in melanin-like dopamine oligomers: a DFT study
Context: Melanin-like dopamine oligomers are promising biomaterials due to their biocompatibility and metal-chelating ability. In this work, Zn 2+ -chelated melanin-related structures were investigated to clarify the effects of metal coordination on their electronic structure. The results indicate that Zn 2+ coordination induces significant electronic polarization, modifies local reactivity patterns, and activates the coordination sites. The theoretical results are also consistent with available spectroscopic observations, providing molecular-level insight into the antibacterial behavior of these complexes and supporting the design of related bioactive materials. Methods: Density functional theory (DFT) calculations were performed for 5,6-dihydroxyindole (DHI), 5,6-dihydroxyindole-2-carboxylic acid (DHICA), and DHI-based oligomeric structures in different deprotonation states. Geometry optimizations and electronic-structure analyses were carried out using the B3LYP functional and 6-31G(d,p) basis set, including Grimme correction (GD3) and solvent effects through the polarizable continuum model (PCM) for water, as implemented in the Gaussian 16 software package. Local reactivity was investigated through condensed-to-atom Fukui indices (CAFIs) and molecular electrostatic potential (MEP) analyses. Zn 2+ coordination and complex stability were further evaluated using calculations performed with the ORCA computational package and complementary automated interaction site screening (aISS) analyses followed by geometry optimizations with the GFN2-xTB approach implemented in the xTB package.
- 19 December 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
- Vol. 239 (6) , 767-775
Tribological behavior study of new titanium alloys for biomedical applications
Developing new titanium alloys and studying their feasibility for dental implants and orthopedic prostheses has been essential to avoid side effects and additional expensive surgeries. The goal of this contribution is to report the tribological behavior of two groups of alloys developed via arc melting, Ti-15Zr and Ti-15Zr-5Mo. To compare the performance of the studied biomaterials, the surface preparation was performed using metallographic techniques. Subsequently, the XRD and microhardness tests were performed to complement the experiments. The tribological tests were accomplished with microscopic analysis to understand the surface modifications. The results indicated that both Ti-15Zr and Ti-15Zr-5Mo alloys showed promising potential, with ternary alloy presenting better performance at low load (1.5 N), with binary alloys presenting superior performance at higher load until 15 N.
- 19 December 2024
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part J: Journal of Engineering Tribology
- Vol. 239 (6) , 767-775
Tribological behavior study of new titanium alloys for biomedical applications
Developing new titanium alloys and studying their feasibility for dental implants and orthopedic prostheses has been essential to avoid side effects and additional expensive surgeries. The goal of this contribution is to report the tribological behavior of two groups of alloys developed via arc melting, Ti-15Zr and Ti-15Zr-5Mo. To compare the performance of the studied biomaterials, the surface preparation was performed using metallographic techniques. Subsequently, the XRD and microhardness tests were performed to complement the experiments. The tribological tests were accomplished with microscopic analysis to understand the surface modifications. The results indicated that both Ti-15Zr and Ti-15Zr-5Mo alloys showed promising potential, with ternary alloy presenting better performance at low load (1.5 N), with binary alloys presenting superior performance at higher load until 15 N.
- Open Access
Ti–15Zr and Ti–15Zr–5Mo Biomaterials Alloys: An Analysis of Corrosion and Tribocorrosion Behavior in Phosphate-Buffered Saline Solution
It is crucial for clinical needs to develop novel titanium alloys feasible for long-term use as orthopedic and dental prostheses to prevent adverse implications and further expensive procedures. The primary purpose of this research was to investigate the corrosion and tribocorrosion behavior in the phosphate buffered saline (PBS) of two recently developed titanium alloys, Ti–15Zr and Ti–15Zr–5Mo (wt.%) and compare them with the commercially pure titanium grade 4 (CP–Ti G4). Density, XRF, XRD, OM, SEM, and Vickers microhardness analyses were conducted to give details about the phase composition and the mechanical properties. Additionally, electrochemical impedance spectroscopy was used to supplement the corrosion studies, while confocal microscopy and SEM imaging of the wear track were used to evaluate the tribocorrosion mechanisms. As a result, the Ti–15Zr (α + α′ phase) and Ti–15Zr–5Mo (α″ + β phase) samples exhibited advantageous properties compared to CP–Ti G4 in the electrochemical and tribocorrosion tests. Moreover, a better recovery capacity of the passive oxide layer was observed in the studied alloys. These results open new horizons for biomedical applications of Ti–Zr–Mo alloys, such as dental and orthopedical prostheses.
Open AccessTi–15Zr and Ti–15Zr–5Mo Biomaterials Alloys: An Analysis of Corrosion and Tribocorrosion Behavior in Phosphate-Buffered Saline Solution
It is crucial for clinical needs to develop novel titanium alloys feasible for long-term use as orthopedic and dental prostheses to prevent adverse implications and further expensive procedures. The primary purpose of this research was to investigate the corrosion and tribocorrosion behavior in the phosphate buffered saline (PBS) of two recently developed titanium alloys, Ti–15Zr and Ti–15Zr–5Mo (wt.%) and compare them with the commercially pure titanium grade 4 (CP–Ti G4). Density, XRF, XRD, OM, SEM, and Vickers microhardness analyses were conducted to give details about the phase composition and the mechanical properties. Additionally, electrochemical impedance spectroscopy was used to supplement the corrosion studies, while confocal microscopy and SEM imaging of the wear track were used to evaluate the tribocorrosion mechanisms. As a result, the Ti–15Zr (α + α′ phase) and Ti–15Zr–5Mo (α″ + β phase) samples exhibited advantageous properties compared to CP–Ti G4 in the electrochemical and tribocorrosion tests. Moreover, a better recovery capacity of the passive oxide layer was observed in the studied alloys. These results open new horizons for biomedical applications of Ti–Zr–Mo alloys, such as dental and orthopedical prostheses.
- Open Access
A Tribological Investigation of the Titanium Oxide and Calcium Phosphate Coating Electrochemical Deposited on Titanium
Titanium (Ti) and its alloys are widely used in biomedical applications due to their excellent mechanical properties and biocompatibility. However, they are a concern due to the possibility of cytotoxic effects coming from the degradation products. This degradation occurs by the combined action of corrosion and mechanical wear of these materials, which are released in the biological environment by the biomaterial implanted. The present article aims to investigate a new route to improve electrochemical and tribological performance with surface modification. Regarding the deposition of a protective layer on the surface, it consists of titanium oxide (TiO2) and calcium phosphate (CaP). Both coatings were performed by chronoamperometric methods with titanium oxidation at 1 V and calcium phosphate reduction at −1.5 V. The corrosion and tribocorrosion tests demonstrated the effective combination of TiO2 and CaP layer to protect the Ti substrate. Furthermore, this coating combination reduced corrosion degradation and mechanical wear in PBS, simulating a physiological environment. Additionally, it was observed that this combination of coating decreased the dissipated energy, and consequently, the wear decreased during sliding tests. All these findings indicate the protective behavior of the TiO2 and CaP layer during the tribocorrosion tests.
Open AccessA Tribological Investigation of the Titanium Oxide and Calcium Phosphate Coating Electrochemical Deposited on Titanium
Titanium (Ti) and its alloys are widely used in biomedical applications due to their excellent mechanical properties and biocompatibility. However, they are a concern due to the possibility of cytotoxic effects coming from the degradation products. This degradation occurs by the combined action of corrosion and mechanical wear of these materials, which are released in the biological environment by the biomaterial implanted. The present article aims to investigate a new route to improve electrochemical and tribological performance with surface modification. Regarding the deposition of a protective layer on the surface, it consists of titanium oxide (TiO2) and calcium phosphate (CaP). Both coatings were performed by chronoamperometric methods with titanium oxidation at 1 V and calcium phosphate reduction at −1.5 V. The corrosion and tribocorrosion tests demonstrated the effective combination of TiO2 and CaP layer to protect the Ti substrate. Furthermore, this coating combination reduced corrosion degradation and mechanical wear in PBS, simulating a physiological environment. Additionally, it was observed that this combination of coating decreased the dissipated energy, and consequently, the wear decreased during sliding tests. All these findings indicate the protective behavior of the TiO2 and CaP layer during the tribocorrosion tests.
- Open Access
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 28 (2) , e20230029
Estudo da eletrodeposição de óxido de titânio com adição de magnésio em substrato de titânio com corrente constante
Atualmente, o substrato de titânio é um dos mais importantes biomateriais metálicos com aplicação em ortopedia, odontologia, fixação de fraturas e artroplastia de joelho e quadril. Apesar de todas estas propriedades atrativas, sua inércia biológica e baixa capacidade bactericida acaba limitando sua osseointegração. Neste sentido, revestimentos de TiO2 e TiO2(MgO) são realizados para aprimorar as características do titânio, como a resistência à corrosão. Os objetivos deste estudo foram analisar a resistência à corrosão do óxido de titânio e óxido de titânio com adição de magnésio, topografias, morfologias e cristalinidade em um substrato de titânio através da eletrodeposição com corrente constante. As eletrodeposições foram realizadas em um sistema de três eletrodos, sendo o titânio eletrodo de trabalho, Ag/AgCl como eletrodo de referência e um contra eletrodo de platina em um potenciostato e foram utilizadas correntes constantes de 1,0 mA/cm2 para todos os processos. Foram utilizadas as caracterizações por microscopia eletrônica de varredura (MEV), microscopia de força atômica (MFA), microscopia confocal, difração de raios X (DRX) e polarização potenciodinâmica. As análises de topografia e morfologia indicaram uma alteração nas rugosidades (Ra) e todas demonstraram uma superfície uniforme. As análises de DRX indicaram apenas o titânio metálico, porém todas tiveram uma diferença no FWHM, indicando possíveis fases amorfas ou Mg intersticial, causando também uma variação na altura dos picos. Por fim, a polarização potenciodinâmica indicou que o revestimento com TiO2 houve uma melhora de 37,90% e o TiO2 com adição de magnésio houve uma perda de 13,43%. Portanto, os revestimentos causaram alterações nas rugosidades, morfologias, redes cristalinas e nas propriedades anticorrosivas, possibilitando assim a modulação das propriedades desejadas de acordo com o ambiente de oxidação utilizado.
- 1 January 2023
- Published by FapUNIFESP (SciELO) in Matéria (Rio de Janeiro)
- Vol. 28 (2) , e20230029
Open AccessEstudo da eletrodeposição de óxido de titânio com adição de magnésio em substrato de titânio com corrente constante
Atualmente, o substrato de titânio é um dos mais importantes biomateriais metálicos com aplicação em ortopedia, odontologia, fixação de fraturas e artroplastia de joelho e quadril. Apesar de todas estas propriedades atrativas, sua inércia biológica e baixa capacidade bactericida acaba limitando sua osseointegração. Neste sentido, revestimentos de TiO2 e TiO2(MgO) são realizados para aprimorar as características do titânio, como a resistência à corrosão. Os objetivos deste estudo foram analisar a resistência à corrosão do óxido de titânio e óxido de titânio com adição de magnésio, topografias, morfologias e cristalinidade em um substrato de titânio através da eletrodeposição com corrente constante. As eletrodeposições foram realizadas em um sistema de três eletrodos, sendo o titânio eletrodo de trabalho, Ag/AgCl como eletrodo de referência e um contra eletrodo de platina em um potenciostato e foram utilizadas correntes constantes de 1,0 mA/cm2 para todos os processos. Foram utilizadas as caracterizações por microscopia eletrônica de varredura (MEV), microscopia de força atômica (MFA), microscopia confocal, difração de raios X (DRX) e polarização potenciodinâmica. As análises de topografia e morfologia indicaram uma alteração nas rugosidades (Ra) e todas demonstraram uma superfície uniforme. As análises de DRX indicaram apenas o titânio metálico, porém todas tiveram uma diferença no FWHM, indicando possíveis fases amorfas ou Mg intersticial, causando também uma variação na altura dos picos. Por fim, a polarização potenciodinâmica indicou que o revestimento com TiO2 houve uma melhora de 37,90% e o TiO2 com adição de magnésio houve uma perda de 13,43%. Portanto, os revestimentos causaram alterações nas rugosidades, morfologias, redes cristalinas e nas propriedades anticorrosivas, possibilitando assim a modulação das propriedades desejadas de acordo com o ambiente de oxidação utilizado.
- 7 January 2021
- Published by Taylor & Francis in Nanomedicine
- Vol. 16 (1) , 5-17
Synthesis of Mussel-Inspired Polydopamine-Gallium Nanoparticles for Biomedical Applications
Aim: To established a simple, controlled and reproducible method to synthesize gallium (Ga)-coated polydopamine (PDA) nanoparticles (NPs). Materials & methods: PDA NPs were synthesized in alkali me... Graphical abstract
- 7 January 2021
- Published by Taylor & Francis in Nanomedicine
- Vol. 16 (1) , 5-17
Synthesis of Mussel-Inspired Polydopamine-Gallium Nanoparticles for Biomedical Applications
Aim: To established a simple, controlled and reproducible method to synthesize gallium (Ga)-coated polydopamine (PDA) nanoparticles (NPs). Materials & methods: PDA NPs were synthesized in alkali me... Graphical abstract
- 27 March 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (6) , 065513
Use of industrial residues for production of cellular glasses of low environmental impact
- 27 March 2019
- Published by IOP Publishing in Materials Research Express
- Vol. 6 (6) , 065513
Use of industrial residues for production of cellular glasses of low environmental impact