HTHriteshwar Talukder

Hriteshwar Talukder

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hriteshwar Talukder has a total of 30 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Non-Bloch band theory of non-Hermitian photonic crystals

    by Zhijie Zhang, Hriteshwar Talukder, Roberto Paiella

  • Double-layered side-polished ultra-highly sensitive photonic crystal fiber-based surface plasmonic refractive index sensor

    by Hriteshwar Talukder, M. Hussayeen Khan Anik, M. Ifaz Ahmad Isti, Sakib Mahmud, Urmi Talukder, Shovasis Kumar Biswas, Baraa Riyadh Altahan, Lassaad K. Smirani, S. K. Hasane Ahammad, Ahmed Nabih Zaki Rashed


  • Numerical Investigation of a Gear-Shaped Triple-Band Perfect Terahertz Metamaterial Absorber as Biochemical Sensor

    by M. Hussayeen Khan Anik, Sakib Mahmud, K. B. M. Sharif Mahmood, Bokhtiar- Al- Zami, M. Ifaz Ahmad Isti, Hriteshwar Talukder, Shovasis Kumar Biswas

    In this work, a triple-band perfect metamaterial absorber (MA) in the terahertz (THz) regime is demonstrated for different biochemical sensing applications. The metasurface’s unit cell is made up of a distinct metallic gear-shaped core with eight identical teeth and two concentric circular rings on the top layer. Finite Difference Time Domain (FDTD) method-based software is utilized for modeling and numerical analysis, and a genetic algorithm (GA) is employed to optimize some geometric parameters of the absorber. The proposed MA shows almost 100% absorption in the frequency range from 0.5 to 4.5 THz. The MA becomes almost insensitive to polarization angle when the number of gear-tooth has been increased. Resonance frequencies can be tweaked by adjusting the top layer’s geometric parameters while maintaining the absorption constant. The influence of different metals and forms in the top layer, such as solid and hollow circular metallic cores, on absorption spectra is also illustrated in this paper. The modelled MA can detect glucose, ethanol, oils, and cancer cell (BCC) by changing the resonance frequency and peak absorption of the spectra due to the variation in refractive index (RI) of the sample. When detecting ethanol, the absorber achieves a maximum sensitivity and figure of merit (FOM) of 56.67 THz/RIU and 358.7 RIU-1 respectively. In addition, effects of incident angle of light and bending of MA on absorption are analyzed in this study. With this unique feasible design, structural tunability and high sensitivity, the proposed absorber exhibits good promise in detecting biochemicals in THz region.


  • Highly sensitive double D-shaped channel photonic crystal fiber based plasmonic refractive index sensor

    by M. Ifaz Ahmad Isti, M. Hussayeen Khan Anik, Samiha Nuzhat, Rubel Chandra Talukder, Sadia Sultana, Shovasis Kumar Biswas, Hriteshwar Talukder

    In this paper, a highly sensitive miniaturized surface plasmon resonance (SPR) based photonic crystal fiber (PCF) sensor is presented for a wide range of analyte sensing. Gold is selected as the plasmonic metal for its higher chemical stability and titanium oxide works as the adhesive layer for gold attachment on silica. The plasmonic metal and the sensing medium are placed exterior to the surface of the sensor design to make it fitting for practical applications. By a careful arrangement of the periodic arrangement of the refractive index in the design, the generation of the evanescent fields is fine-tuned to obtain the phase matching between the leaky core guided mode and the surface plasmon polariton (SPP) mode. Numerical simulations have been carried out by employing the finite element method (FEM) with the consideration of a perfectly matched layer (PML) to absorb surface radiations. The proposed sensor shows a maximum wavelength sensitivity of 34,000 nm/RIU (refractive index units) and a maximum amplitude sensitivity of 331 RIU−1, investigated by using the wavelength and the amplitude interrogation methods, respectively, for the analyte sensing range of 1.16 to 1.37 RI (refractive index). The sensor also exhibits a wavelength resolution of 2.94×10−6 RIU which indicates a high detection accuracy. On that, the proposed sensor would be an excellent candidate for a wide range of RI detection, applicable for various purposes such as chemical detections, medical diagnostics, bio-sensing, and other low RI analytes.


  • A Highly Sensitive Gold-TiO2 Coated Dual-Core PCF-SPR Sensor with a Large Detection Range

    by Sanjida Sultana, Faiyaz Bin Haassan, Shovasis Kumar Biswas, Hriteshwar Talukder


  • Open Access

    Numerical Design and Investigation of Circularly Segmented Air Holes-Assisted Hollow-Core Terahertz Waveguide as Optical Chemical Sensor

    by M. Hussayeen Khan Anik, S. M. Riazul Islam, Shovasis Kumar Biswas, M. Ifaz Ahmad Isti, Mohona Das Gupta, Jalil Piran, Kyung-Sup Kwak, Hriteshwar Talukder

    In this paper,a polarization-maintaining single-mode rectangular-shaped hollow-core waveguide with four segmented air cladding in the terahertz (THz) regime is presented for detecting various toxic industrial chemicals. A new type of injection moldable cyclic olefin copolymer, commercially named as TOPAS is used as the base fiber material for its high optical transmission and high resistance to other chemicals. The finite element method with a perfectly matched layer as the boundary condition is employed for numerical explorations. The proposed sensor exhibits ultra-high relative sensitivity of 99.73% and ultra-low effective material loss of 0.007 cm -1 at 1.6 THz frequency for Toluene in y polarization. This sensor also evinces a high birefringence of 4.16×10 -3 at 1.6 THz frequency. A maximum V parameter of 2.224 has been found at 2.2 THz which ensures the single-mode propagation of light. The sensor shows a very low confinement loss of 3.2×10 -11 dB/m and a high numerical aperture of 0.3574 at 1.6 THz frequency for Hydrogen Sulfide. This paper also concentrates on other important design parameters such as bending loss, mode field radius, beam divergence and effective area for serviceability of the sensor in the THz region. This sensor can be a very good candidate for various chemical detection as well as other applications in the terahertz regime.


  • Top Cited Papers

    Hate Speech Detection in the Bengali Language: A Dataset and Its Baseline Evaluation

    by Nauros Romim, Mosahed Ahmed, Hriteshwar Talukder, Saiful Islam


  • Open Access

    Milled Microchannel-Assisted Open D-Channel Photonic Crystal Fiber Plasmonic Biosensor

    by M. Hussayeen Khan Anik, M. Ifaz Ahmad Isti, S. M. Riazul Islam, Sakib Mahmud, Hriteshwar Talukder, Jalil Piran, Shovasis Kumar Biswas, Kyung-Sup Kwak

    A surface plasmon resonance (SPR) based photonic crystal fiber (PCF) sensor having a milled microchannel, and an open D-channel has been proposed in this paper. The sensor shows good functionality in the wide sensing range of 1.14-1.36 Refractive Index Units (RIU) of the analyte, having the capability to detect low refractive index (RI). The Finite Element Method (FEM) based numerical investigations dictate that the proposed sensor has been able to gain a maximum wavelength sensitivity of 53,800 nm/RIU according to the wavelength interrogation technique. The amplitude interrogations show that the sensor has the highest amplitude sensitivity of 328 RIU -1 . The highest FOM (Figure of Merit) has been found to be 105 RIU -1 . The sensor evinces a minimum wavelength resolution of $1.86\times 10 ^{-6}$ RIU, which secures high detection accuracy. A circular perfectly matched layer (PML) is implemented in the sensor's outermost layer as a boundary condition to absorb surface radiations. Gold is the plasmonic metal, while TiO2 acts as the adhesive layer for gold attachment on silica. Due to the high sensitivity with a broad range of analyte detection, the sensor is well suited for practical biochemical detection purposes.