YMYu Meng

Yu Meng

*This is an algorithmically generated author record based on publicly available information.

Yu Meng has a total of 34 co-authors. Here are the top co-authors by number of shared publications:

  • Xianlei Chen

    Zhoushan Institute of Calibration and Testing for Quality and Technology Supervision, Zhoushan 316000, China

    4 shared publications
  • Bingyuan Hong

    National & Local Joint Engineering Research Center of Harbor Oil & Gas Storage and Transportation Technology, Zhejiang Key Laboratory of Pollution Control for Port-Petrochemical Industry, Zhejiang Key Laboratory of Petrochemical Environmental Pollution Control, School of Petrochemical Engineering & Environment, Zhejiang Ocean University, Zhoushan 316022, China

    2 shared publications
  • Chengxu Tu

    Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou 310018, China

    2 shared publications
  • Daiwei Liu

    National & Local Joint Engineering Research Center of Harbor Oil & Gas Storage and Transportation Technology/Zhejiang Key Laboratory of Petrochemical Environmental Pollution Control/Zhejiang Key Laboratory of Pollution Control for Port-Petrochemical Industry, School of Petrochemical Engineering & Environment, Zhejiang Ocean University, Zhoushan 316022, China

    2 shared publications
  • Fubing Bao

    Zhejiang Provincial Key Laboratory of Flow Measurement Technology, China Jiliang University, Hangzhou 310018, China

    2 shared publications
  • Shanyi Xu

    College of Metrology Measurement and Instrument, China Jiliang University, Hangzhou 310018, China

    2 shared publications

Latest Publications

  • Open Access

    Structural Design and Experimental Investigation of the Mechanical Performance of Aluminum-Foil- and EVOH-Barrier Unbonded Flexible Pipes for Hydrogen Transport

    by Zenan Wu, Zhongjian Sun, Qianchao Cai, Yuhao Wang, Hao Tian, Xianlei Chen, Yu Meng, Wei Liu, Daiwei Liu, Zhiwei Chen, et al.

    The large-scale deployment of hydrogen energy has created an urgent demand for safe, efficient, and cost-effective hydrogen transportation infrastructure. Reducing transportation costs and improving pipeline reliability are critical for the development of hydrogen supply systems. Owing to their light weight, corrosion resistance, and continuous installation capability, unbonded flexible pipes have emerged as promising alternatives for high-pressure hydrogen transportation. In this study, two DN65 unbonded flexible pipes are designed, with aluminum foil and ethylene–vinyl alcohol copolymer (EVOH) adopted as barrier layers, respectively. Internal-pressure burst tests, 100 h hydrostatic pressure tests, axial tensile tests, and minimum bend radius tests are conducted to evaluate their mechanical performance and service adaptability. The results reveal that the ultimate failure of both pipes is primarily governed by tensile fracture of the reinforcing fibers. Compared with the aluminum-foil-barrier pipe, the EVOH-barrier pipe demonstrates superior pressure resistance and tensile strength, with the average burst pressure increasing from 33.856 MPa to 37.219 MPa, representing a 9.9% improvement, while the peak tensile load rises from 196.4 kN to 292.7 kN, corresponding to a 49% enhancement. In contrast, the aluminum-foil-barrier pipe exhibits better post-bending structural stability and energy absorption capability, as evidenced by the smaller increase in residual ovality from 1.45% and the higher deformation energy sustained before reaching the peak load of 79.2 kJ, compared with 4.16% and 48.2 kJ for the EVOH-barrier pipe. Under the tested conditions, the EVOH-barrier pipe exhibited higher burst resistance and axial tensile capacity, whereas the aluminum-foil-barrier pipe showed better cross-sectional shape retention and high pre-peak deformation work under axial tension. Because the two pipe types also differ in their as-manufactured layer dimensions, these mechanical differences should be interpreted as configuration-level responses rather than isolated effects of the barrier materials. These results indicate that under the operating pressure greater than 10 MPa, the two barrier structures have different mechanical advantages.

  • Open Access

    Advances in Electrofusion Welding Technology for Polymeric Pipelines: From Process Optimization to Mechanism-Driven Control

    by Bingyuan Hong, Zhongjian Sun, Zenan Wu, Yu Meng, Zhiwei Chen, Xianlei Chen, Weiqiang Wang, Daiwei Liu

    With the rapid development of clean and low-carbon energy systems, non-metallic pipelines have become increasingly important in urban gas distribution, water supply, and emerging energy-transport applications, including hydrogen service. As a critical joining technology that governs system integrity and long-term operational safety, electrofusion welding requires a comprehensive and mechanism-oriented understanding beyond empirical process control. In this study, a review is conducted on research published over the past decade in the field of electrofusion welding of non-metallic pipelines, with emphasis on fundamental technical issues including the formation and evolution of temperature fields, characteristics of the molten fusion zone and defect development, and thermo-mechanical coupling with residual stress generation. Based on a synthesis of the literature, the review clarifies the global research landscape, core research communities, and underlying knowledge structure. The results indicate a clear transition of the field from empirically driven parameter optimization toward a mechanism-based and process-controllable paradigm centered on temperature field evolution, fusion zone development, and thermo-mechanical behavior. Current research hotspots converge on HDPE material adaptability, welding process regulation, and the long-term reliability of welded joints. Building on these insights, future research directions are discussed, including mechanism-driven process design, intelligent defect identification based on multi-source data, and full-life reliability assessment under service conditions. This review provides a theoretical framework to support process optimization and engineering application of electrofusion welding in non-metallic pipeline systems.


  • Open Access

    Numerical Simulation for Lightweight Design of a Liquid Hydrogen Weighing Tank for Flow Standard

    by Xiang Li, Menghui Wu, Xianlei Chen, Yu Meng, Xiaobin Zhang, Weijie Chen, Shanyi Xu, Naifeng Nie, Yongcheng Zhu, Jianan Zhou, et al.

    To improve the accuracy of gravimetric liquid hydrogen flow standard devices, the self-weight of the weighing tank must be minimized, because the total mass of the liquid hydrogen contained in the tank is far smaller than the structural mass of the tank itself, which severely compromises the sensitivity of gravimetric measurement. In this study, a three-dimensional finite element model of a vacuum-insulated liquid-hydrogen weighing tank was developed in ABAQUS. The inner and outer shells were modeled with 06Cr19Ni10 (304) and 06Cr17Ni12Mo2 (316) austenitic stainless steels, and Polyamide 6 (PA6) was used for the internal support. Three operating stages were considered: evacuation of the annulus (interlayer pressure reduced from 0.1 MPa to 0 MPa), pre-cooling to −253 °C, and pressurization of the inner tank (internal pressure increased from 0.1 MPa to 1 MPa). The equivalent stress and deformation were compared for different materials and wall thicknesses to evaluate structural safety and weight-reduction potential. The proposed configuration (inner shell 1.6 mm and outer shell 1.0 mm) achieves a mass reduction of more than 50% relative to the 3 mm minimum wall thickness commonly adopted for cryogenic vessels, while keeping stresses below the allowable limits. This reduction enables the use of higher-resolution load cells and thereby lowering the measurement uncertainty of the liquid hydrogen flow standard device and providing technical support for lightweight and cost-effective design, with potential applicability to other cryogenic tank systems.

  • Open Access

    Numerical Study on the Effect of Upstream Piping Configuration on Flow Diverter Performance

    by Xiang Li, Menghui Wu, Xianlei Chen, Yu Meng, Xiaobin Zhang, Qingsong Shi, Shanyi Xu, Naifeng Nie, Daolin Wang, Zexian Zu, et al.

    Liquid hydrogen, a cryogenic fluid with extremely low density and viscosity, plays a crucial role in zero-carbon energy strategies. It has become a prominent research focus in the field of new energy strategy. In most processes within the liquid hydrogen industry chain, liquid hydrogen flow measurement is involved. This paper focuses on the study of the flow diverter, a key component of the liquid hydrogen flow standard device. Aiming at the high thermal insulation requirement of liquid hydrogen, the straight piping in the conventional flow standard device is optimized. A combined coiled-vertical piping with key equipment is enclosed in a vacuum cold box for centralized thermal insulation. Fluid flow during diverter switching under four piping configurations was simulated using ANSYS Fluent for both water and liquid hydrogen. The influence of piping structure on flow error during the switching of the diverter is systematically studied. From the simulation results, it can be concluded that the U-shaped piping effectively avoids the inertia and overshoot effects during fluid switching, which helps to reduce errors caused by commutation.

  • Tensile Response of a Flexible Pipe With an Incomplete Tensile Armor Layer

    by Xiaohua Zhu, Qinglong Lei, Yu Meng, Xiaoxuan Cui

    Unbonded flexible pipes are widely utilized in the exploitation of offshore oil and gas resources. They are connected to two of the most critical types of system: floating production platforms and underwater production systems. However, if some tensile armor wires are substituted by cables or broken, the tensile armor layer will be incomplete, which seriously reduces the safety and reliability of the flexible pipe. In the present study, models of a flexible pipe with a complete tensile layer and with the tensile layer partially missing were established. The error for the tensile stiffness obtained by the finite element model of an intact flexible pipe was only 1% compared with experimental results. Because the load borne by the inner tensile armor layer is larger under tension than that borne by the outer tensile armor layer, the loss of inner tensile armor wires has a greater impact on the tensile properties. The maximum axial elongation of the flexible pipe increases with the number of missing inner tensile armor wires as a cubic polynomial. If the distribution of the missing armor wires is too dense, a stress concentration and local bending may occur, which will reduce the tensile strength of the flexible pipe.