Thomas P. Crowley
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Thomas P. Crowley has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Diane R Demers
Xantho Technologies, LLC, Madison, WI (United States)
4 shared publications - P. J. Fimognari
Xantho Technologies, LLC, Madison, Wisconsin 53705, USA
4 shared publications A. Ouroua
Rensselaer Polytechnic Institute, Troy, New York 12180
2 shared publicationsD. R. Demers
Xantho Technologies, LLC, Madison, Wisconsin 53705, USA
2 shared publications- H. Trimino Mora
Max-Planck Institute for Plasma Physics 2 , Greifswald, MV 17491
2 shared publications P. E. McLaren
Rensselaer Polytechnic Institute, Troy, New York 12180
2 shared publications
Latest Publications
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Heavy ion beam probe for Wendelstein 7-X measurement capabilities as projected through its design
A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.
- 1 August 2024
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 95 (8)
Heavy ion beam probe for Wendelstein 7-X measurement capabilities as projected through its design
A heavy ion beam probe (HIBP) diagnostic is being developed for studies of plasma equilibrium and turbulence in the optimized Wendelstein 7-X (W7-X) stellarator. Operation of W7-X has experimentally demonstrated that its optimized magnetic field results in improved neoclassical particle confinement and, as a result, turbulence is the predominant cause of energy transport. The HIBP will have the unique ability to provide experimental data needed to complement models of both neoclassical and turbulent transport. It will acquire direct measurements in the W7-X plasma interior of the electric potential (needed for understanding ambipolar particle flux) and fluctuations of electron density and potential (needed for understanding turbulence). The HIBP for W7-X will inject singly charged ion beams with energies of up to 2 MeV and is designed to access the upper cross section of the W7-X plasma. We use trajectory simulations to illustrate the plasma coverage that the diagnostic can achieve in the reference magnetic configurations of W7-X. We calculate beam signal levels, discuss anticipated measurement sensitivity of broadband fluctuations of electron density and plasma potential, and show how they depend on plasma density. We also discuss the diagnostic sensitivity to equilibrium plasma potential.
- Open Access
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113309
Conceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator
This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.
- 1 November 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (11) , 113309
Open AccessConceptual design of a heavy ion beam probe diagnostic for the Wendelstein 7-X Stellarator
This article describes the current state of the design of the heavy ion beam probe (HIBP) for Wendelstein 7-X (W7-X). It will be the first HIBP diagnostic on an optimized stellarator and is designed to study electric fields and ion scale turbulence in all W7-X reference magnetic configurations. The use of an existing 2 MV accelerator, located outside of the torus hall, results in the need for a circuitous primary beamline. This increases the complexity of the ion optics design to deliver a focused beam to the plasma. To access most of the magnetic configuration space of W7-X, the secondary beamline and an energy analyzer are designed to pivot, thereby redirecting a wider range of secondary beam trajectories. Signal level estimates indicate that the equilibrium potential can be measured at all radii and that the radial coverage for potential and density fluctuations measurements depends on the plasma density.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 013503
Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics
A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize these properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator, and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. The improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 013503
Improvement in the spatial resolution of heavy ion beam probe measurements through application of ion optics
A technique for more accurately modeling and improving the spatial resolution of heavy ion beam probe measurements is described. We use a set of particle trajectories to numerically determine the focusing properties of a complicated three-dimensional magnetic field and characterize these properties with a transfer matrix. We then modify the transfer matrix approach of traditional ion optics to include a parameter that describes the ionization location of the detected ions. The ion optics model calculated using this technique enables a more accurate description of the particle trajectories than previously feasible. The model also allows one to easily determine an initial beam focus that could be used during experimental operation to optimize the spatial resolution of measurements. The technique has been applied to the design of a heavy ion beam probe diagnostic for the Wendelstein 7-X stellarator, and improvements in the modeled spatial resolution by a factor of about 2 over previous estimates are possible. The improved spatial resolution will enable measurements of plasma fluctuations with smaller wavelengths than would otherwise be possible.
- 21 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (2) , 558-565
Characterization of a Type-N Coaxial Microcalorimeter for Use as Microwave Power Standard at CENAM
This paper describes the metrological characterization of a new type-N coaxial microcalorimeter and its associated thermistor-type transfer standard, which together are used as the primary standard for microwave power from 0.05 to 18 GHz at the Centro Nacional de Metrología, Queretaro, Mexico. The design characteristics, evaluation method, and measurement uncertainties of the primary standard are given and compared to recent realizations found in the open literature. The metrological characterization of the microcalorimeter is based on a comparison method to indirectly obtain its correction factor. The effective efficiency of the transfer standard, directly calibrated in the microcalorimeter by means of calorimetric measurements, is shown and compared against measurements performed by National Institute of Standards and Technology, showing good agreement within the estimated expanded uncertainties (0.21%-0.47%). The developed data acquisition system to automate the effective efficiency measurements and the proposed software leveling loop to keep the microwave power level constant are also discussed. This approach allows to keep an RF power stability of better than 100 ppm over several hours and is a straightforward solution to replace analog leveling systems which require obsolete hardware. Finally, the analysis followed to evaluate the uncertainty for the effective efficiency measurements is thoroughly described.
- 21 June 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 68 (2) , 558-565
Characterization of a Type-N Coaxial Microcalorimeter for Use as Microwave Power Standard at CENAM
This paper describes the metrological characterization of a new type-N coaxial microcalorimeter and its associated thermistor-type transfer standard, which together are used as the primary standard for microwave power from 0.05 to 18 GHz at the Centro Nacional de Metrología, Queretaro, Mexico. The design characteristics, evaluation method, and measurement uncertainties of the primary standard are given and compared to recent realizations found in the open literature. The metrological characterization of the microcalorimeter is based on a comparison method to indirectly obtain its correction factor. The effective efficiency of the transfer standard, directly calibrated in the microcalorimeter by means of calorimetric measurements, is shown and compared against measurements performed by National Institute of Standards and Technology, showing good agreement within the estimated expanded uncertainties (0.21%-0.47%). The developed data acquisition system to automate the effective efficiency measurements and the proposed software leveling loop to keep the microwave power level constant are also discussed. This approach allows to keep an RF power stability of better than 100 ppm over several hours and is a straightforward solution to replace analog leveling systems which require obsolete hardware. Finally, the analysis followed to evaluate the uncertainty for the effective efficiency measurements is thoroughly described.
- 8 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11D418
Control of secondary electrons from ion beam impact using a positive potential electrode
Secondary electrons emitted when an ion beam impacts a detector can amplify the ion beam signal, but also introduce errors if electrons from one detector propagate to another. A potassium ion beam and a detector comprised of ten impact wires, four split-plates, and a pair of biased electrodes were used to demonstrate that a low-voltage, positive electrode can be used to maintain the beneficial amplification effect while greatly reducing the error introduced from the electrons traveling between detector elements.
- 8 August 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (11) , 11D418
Control of secondary electrons from ion beam impact using a positive potential electrode
Secondary electrons emitted when an ion beam impacts a detector can amplify the ion beam signal, but also introduce errors if electrons from one detector propagate to another. A potassium ion beam and a detector comprised of ten impact wires, four split-plates, and a pair of biased electrodes were used to demonstrate that a low-voltage, positive electrode can be used to maintain the beneficial amplification effect while greatly reducing the error introduced from the electrons traveling between detector elements.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05891485,p. 420-421
Design and evaluation of a WR-15 (50 to 75 GHz) microcalorimeter
The design and correction factor evaluation of a WR-15 (50 to 75 GHz) rectangular waveguide microcalorimeter is presented. This new microcalorimeter will be the US national standard for power from 50 to 75 GHz. It can measure the effective efficiency of a wider variety of transfer standards than can the previous microcalorimeter. It has also been designed so that its correction factor can be experimentally evaluated by multiple techniques.
- 1 June 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 05891485,p. 420-421
Design and evaluation of a WR-15 (50 to 75 GHz) microcalorimeter
The design and correction factor evaluation of a WR-15 (50 to 75 GHz) rectangular waveguide microcalorimeter is presented. This new microcalorimeter will be the US national standard for power from 50 to 75 GHz. It can measure the effective efficiency of a wider variety of transfer standards than can the previous microcalorimeter. It has also been designed so that its correction factor can be experimentally evaluated by multiple techniques.
- 1 January 1999
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 70 (1) , 959-962
Preliminary design of a heavy ion beam probe diagnostic for the National Spherical Torus Experiment
The preliminary design of a heavy ion beam probe (HIBP) for the National Spherical Torus Experiment (NSTX) is presented. The primary purpose of the diagnostic would be to measure density and electric potential fluctuations and steady state potential profiles. A secondary purpose is magnetic equilibrium and fluctuation measurements. HIBP particle trajectories have been calculated for a double null discharge case. The key HIBP measurements can be made with the injection point—detection point combination which is presented, including a radial scan line at a single energy (for potential profile measurements), poloidally aligned sample volumes (for poloidal wavenumber measurements), and coverage of a large fraction of the upper low field quadrant of the plasma. In addition, the injection point can be combined with new detectors for radial array measurements (for density fluctuation and/or magnetic measurements). Due to a large range of angles at the detector, up to 23° poloidal angle range and a 6° toroidal angle range, a secondary sweep system will be necessary for NSTX.
- 1 January 1999
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 70 (1) , 959-962
Preliminary design of a heavy ion beam probe diagnostic for the National Spherical Torus Experiment
The preliminary design of a heavy ion beam probe (HIBP) for the National Spherical Torus Experiment (NSTX) is presented. The primary purpose of the diagnostic would be to measure density and electric potential fluctuations and steady state potential profiles. A secondary purpose is magnetic equilibrium and fluctuation measurements. HIBP particle trajectories have been calculated for a double null discharge case. The key HIBP measurements can be made with the injection point—detection point combination which is presented, including a radial scan line at a single energy (for potential profile measurements), poloidally aligned sample volumes (for poloidal wavenumber measurements), and coverage of a large fraction of the upper low field quadrant of the plasma. In addition, the injection point can be combined with new detectors for radial array measurements (for density fluctuation and/or magnetic measurements). Due to a large range of angles at the detector, up to 23° poloidal angle range and a 6° toroidal angle range, a secondary sweep system will be necessary for NSTX.
- 1 January 1997
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 68 (1) , 328-331
A spatial detector array for measuring plasma turbulence with the heavy ion beam probe
The heavy ion beam probe (HIBP) has become a valuable diagnostic for measuring the plasma space potential and electron density in high-temperature plasmas. However, due to the limitations placed on the design of the HIBP by the size and complexity of the electrostatic energy analyzer, only limited information can be extracted from the HIBP’s fluctuation measurements. By extending the range and number of sample volumes simultaneously recorded by the beam probe, a better understanding of the turbulence distribution, S(k,ω), can be achieved. This can be accomplished by installing an array of secondary particle detectors close to the plasma edge. InterScience, Inc. has developed a particle detector capable of measuring the small signal levels required by the HIBP in the high background environment associated with operating near the plasma edge. In addition, this detector has been incorporated into the design of a 20-element, spatial array for the 2 MeV HIBP on TEXT. A flexible design has been developed such that the array can make measurements that are nearly poloidally or radially aligned. With the use of spatial Fourier transform, this will allow the HIBP to better determine S(k,ω). Details of the design of the detector array and initial experimental results will be presented.
- 1 January 1997
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 68 (1) , 328-331
A spatial detector array for measuring plasma turbulence with the heavy ion beam probe
The heavy ion beam probe (HIBP) has become a valuable diagnostic for measuring the plasma space potential and electron density in high-temperature plasmas. However, due to the limitations placed on the design of the HIBP by the size and complexity of the electrostatic energy analyzer, only limited information can be extracted from the HIBP’s fluctuation measurements. By extending the range and number of sample volumes simultaneously recorded by the beam probe, a better understanding of the turbulence distribution, S(k,ω), can be achieved. This can be accomplished by installing an array of secondary particle detectors close to the plasma edge. InterScience, Inc. has developed a particle detector capable of measuring the small signal levels required by the HIBP in the high background environment associated with operating near the plasma edge. In addition, this detector has been incorporated into the design of a 20-element, spatial array for the 2 MeV HIBP on TEXT. A flexible design has been developed such that the array can make measurements that are nearly poloidally or radially aligned. With the use of spatial Fourier transform, this will allow the HIBP to better determine S(k,ω). Details of the design of the detector array and initial experimental results will be presented.
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 316
Plasma potential measurements on text‐upgrade with a 2 MeV heavy ion beam probe (abstract)a)
The plasma potential is measured in TEXT‐upgrade tokamak by injection and detection of high energy heavy ions (thallium and cesium with a single charge) using a 2 MeV accelerator and a parallel plate energy analyzer. The change in beam energy, as it crosses the plasma, gives the local plasma potential at the measurement volume. Recent results of high energy beam operations are presented.
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 316
Plasma potential measurements on text‐upgrade with a 2 MeV heavy ion beam probe (abstract)a)
The plasma potential is measured in TEXT‐upgrade tokamak by injection and detection of high energy heavy ions (thallium and cesium with a single charge) using a 2 MeV accelerator and a parallel plate energy analyzer. The change in beam energy, as it crosses the plasma, gives the local plasma potential at the measurement volume. Recent results of high energy beam operations are presented.
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 315
Computer control and data acquisition of the heavy ion beam probe (abstract)
The heavy ion beam probe (HIBP) on TEXT‐upgrade and the vertical test stand (VTS) at Rensselaer are to be operated from a virtual control panel using a graphical language interfacea). The system will monitor and control over eighty signals, as well as acquire data using mouse and keyboard inputs. The computer interface utilizes a DEC 5000/240 workstation, two color monitors, SCSI to fiber optic link, and CAMAC crate. Long term goals include remote experimental monitoring and control, and feedback control. The status and visuals of the computercontrol system and results of implementation on the VTS will be presented.
- 1 January 1995
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 66 (1) , 315
Computer control and data acquisition of the heavy ion beam probe (abstract)
The heavy ion beam probe (HIBP) on TEXT‐upgrade and the vertical test stand (VTS) at Rensselaer are to be operated from a virtual control panel using a graphical language interfacea). The system will monitor and control over eighty signals, as well as acquire data using mouse and keyboard inputs. The computer interface utilizes a DEC 5000/240 workstation, two color monitors, SCSI to fiber optic link, and CAMAC crate. Long term goals include remote experimental monitoring and control, and feedback control. The status and visuals of the computercontrol system and results of implementation on the VTS will be presented.