Mao-Shin Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Mao-Shin Lin has a total of 190 co-authors. Here are the top co-authors by number of shared publications:
Hsien-Li Kao
Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan
15 shared publicationsYing-Hsien Chen
National Taiwan University Hospital, Taipei, Taiwan
14 shared publicationsChih-Fan Yeh
National Taiwan University Hospital, Taipei, Taiwan
11 shared publicationsTsung-Yu Ko
National Taiwan University Hospital, Taipei, Taiwan
11 shared publicationsChing-Chang Huang
Division of Cardiology, Department of Internal Medicine and Cardiovascular Center, National Taiwan University Hospital, Taipei, Taiwan
10 shared publicationsChih-Yang Chan
Department of Surgery, National Taiwan University Hospital , Taipei 100225
7 shared publications
Latest Publications
- Open Access
- 6 October 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (19)
Incidence and Predictors of Complications After Transcatheter Aortic Valve Implantation According to VARC‐3 Criteria: A Systematic Review and Meta‐Analysis
Background: Despite continuous advancements in devices and techniques, transcatheter aortic valve implantation remains associated with complications impacting outcomes. In 2021, the Valve Academic Research Consortium (VARC) introduced the VARC‐3 criteria to better classify procedural complications. Methods: We conducted a systematic review and meta‐analysis of studies reporting transcatheter aortic valve implantation‐related complications using VARC‐3 definitions between 2021 and 2025. The primary end point was all‐cause mortality at latest follow‐up. Secondary end points included major VARC‐3 complications and predictors of adverse events. Results: A total of 57 studies with 73 588 patients were included. The cohort had a mean age of 81.7 years, 51.7% were women, and most had preserved ejection fraction (55.5%) and low‐to‐moderate surgical risk (Society of Thoracic Surgeons [STS] predicted risk of mortality [PROM] 4.1%). Technical and 30‐day device success rates were 95% and 90%, respectively; early safety rate at 30 days was 66%. At average 12 months follow‐up, all‐cause mortality was 10.2%. The most common complication was permanent pacemaker implantation (13%), followed by type 2 or greater bleeding (9.7%), acute kidney injury stage 3–4 (4.7%), major vascular events (4.3%), and stroke (3.0%). Moderate/severe paravalvular regurgitation and patient‐prosthesis mismatch occurred in 4% and 8%, respectively. Study‐level pooled predictor analyses showed that acute kidney injury, type 2 or greater bleeding, paravalvular regurgitation, non‐structural valve dysfunction, and higher STS score were associated with higher mortality, while eccentric/severe aortic valve calcification was associated with significant paravalvular regurgitation. Conclusions: Transcatheter aortic valve implantation shows high procedural success but non‐negligible complication rates under VARC‐3 criteria. acute kidney injury, type 2 or greater bleeding, NSVD, periprocedural stroke and myocardial infarction after transcatheter aortic valve implantation were associated with higher mortality.
- 6 October 2026
- Published by Wolters Kluwer Health in Journal of the American Heart Association
- Vol. 15 (19)
Open AccessIncidence and Predictors of Complications After Transcatheter Aortic Valve Implantation According to VARC‐3 Criteria: A Systematic Review and Meta‐Analysis
Background: Despite continuous advancements in devices and techniques, transcatheter aortic valve implantation remains associated with complications impacting outcomes. In 2021, the Valve Academic Research Consortium (VARC) introduced the VARC‐3 criteria to better classify procedural complications. Methods: We conducted a systematic review and meta‐analysis of studies reporting transcatheter aortic valve implantation‐related complications using VARC‐3 definitions between 2021 and 2025. The primary end point was all‐cause mortality at latest follow‐up. Secondary end points included major VARC‐3 complications and predictors of adverse events. Results: A total of 57 studies with 73 588 patients were included. The cohort had a mean age of 81.7 years, 51.7% were women, and most had preserved ejection fraction (55.5%) and low‐to‐moderate surgical risk (Society of Thoracic Surgeons [STS] predicted risk of mortality [PROM] 4.1%). Technical and 30‐day device success rates were 95% and 90%, respectively; early safety rate at 30 days was 66%. At average 12 months follow‐up, all‐cause mortality was 10.2%. The most common complication was permanent pacemaker implantation (13%), followed by type 2 or greater bleeding (9.7%), acute kidney injury stage 3–4 (4.7%), major vascular events (4.3%), and stroke (3.0%). Moderate/severe paravalvular regurgitation and patient‐prosthesis mismatch occurred in 4% and 8%, respectively. Study‐level pooled predictor analyses showed that acute kidney injury, type 2 or greater bleeding, paravalvular regurgitation, non‐structural valve dysfunction, and higher STS score were associated with higher mortality, while eccentric/severe aortic valve calcification was associated with significant paravalvular regurgitation. Conclusions: Transcatheter aortic valve implantation shows high procedural success but non‐negligible complication rates under VARC‐3 criteria. acute kidney injury, type 2 or greater bleeding, NSVD, periprocedural stroke and myocardial infarction after transcatheter aortic valve implantation were associated with higher mortality.
Generalisable artificial intelligence ECG trained on public data for outcome prediction after transcatheter aortic valve replacement
Background Artificial intelligence ECG (AI-ECG) models can predict cardiovascular outcomes, but their clinical adoption is limited by restricted access to training data and uncertain generalisability. We developed and externally validated a generalisable AI-ECG model trained exclusively on publicly available data to predict outcomes after transcatheter aortic valve replacement (TAVR). Methods A transformer-based AI-ECG model was trained on 341 151 publicly available ECGs with mortality labels. The model was externally validated in a prospective cohort of 439 patients undergoing TAVR and additionally tested in a surgical aortic valve replacement cohort. Model performance for predicting 30-day and 1-year mortality was assessed using area under the receiver operating characteristic curve (AUC) and associations with clinical outcomes were evaluated using multivariable regression. Results In the TAVR cohort, a single pre-procedural ECG predicted 30-day mortality with an AUC of 0.85 (95% CI 0.78 to 0.92) and 1-year mortality with an AUC of 0.74 (95% CI 0.67 to 0.80). The derived AI-ECG risk score was independently associated with 1-year mortality (adjusted OR 1.70), major adverse cardiac events and major renal events. Predictive performance was consistent in an independent surgical cohort. High-risk ECG features included atrial fibrillation, prolonged QT interval, ST-T abnormalities and low voltage. Conclusions An AI-ECG model trained solely on publicly available data provides accurate and generalisable prediction of outcomes after TAVR using a single ECG. This approach demonstrates the feasibility of transparent, shareable AI models for cardiovascular risk stratification and supports a general-to-specific paradigm for clinical deployment.
Generalisable artificial intelligence ECG trained on public data for outcome prediction after transcatheter aortic valve replacement
Background Artificial intelligence ECG (AI-ECG) models can predict cardiovascular outcomes, but their clinical adoption is limited by restricted access to training data and uncertain generalisability. We developed and externally validated a generalisable AI-ECG model trained exclusively on publicly available data to predict outcomes after transcatheter aortic valve replacement (TAVR). Methods A transformer-based AI-ECG model was trained on 341 151 publicly available ECGs with mortality labels. The model was externally validated in a prospective cohort of 439 patients undergoing TAVR and additionally tested in a surgical aortic valve replacement cohort. Model performance for predicting 30-day and 1-year mortality was assessed using area under the receiver operating characteristic curve (AUC) and associations with clinical outcomes were evaluated using multivariable regression. Results In the TAVR cohort, a single pre-procedural ECG predicted 30-day mortality with an AUC of 0.85 (95% CI 0.78 to 0.92) and 1-year mortality with an AUC of 0.74 (95% CI 0.67 to 0.80). The derived AI-ECG risk score was independently associated with 1-year mortality (adjusted OR 1.70), major adverse cardiac events and major renal events. Predictive performance was consistent in an independent surgical cohort. High-risk ECG features included atrial fibrillation, prolonged QT interval, ST-T abnormalities and low voltage. Conclusions An AI-ECG model trained solely on publicly available data provides accurate and generalisable prediction of outcomes after TAVR using a single ECG. This approach demonstrates the feasibility of transparent, shareable AI models for cardiovascular risk stratification and supports a general-to-specific paradigm for clinical deployment.
- 1 February 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (2) , e016191
Dynamic Change of Coronary Artery Geometry After Bioadaptor Implantation: A Single-blind Randomized Controlled Trial
BACKGROUND: The DynamX bioadaptor, a novel coronary implant, is designed to restore vessel function when the thin polymer coating covering the helical strands resorbs 6 months post-percutaneous coronary intervention. We aimed to evaluate vessel conformability 1 year after percutaneous coronary intervention with the bioadaptor, compared with conventional drug-eluting stents (DESs). METHODS: Vessel segments were 1:1 randomized to a novolimus-eluting bioadaptor or a durable polymer novolimus-eluting second-generation DES. Coronary computed tomography angiography was performed at 1 and 12 months post-implantation, and the 3-dimensional geometry of the treated segments in coronary computed tomography angiography was analyzed. The primary outcome was the change in dynamic vessel geometry, including curvature flexibility (bending motion), torsion flexibility (twisting motion), and path flexibility (3-dimensional motion) of the treated segment during the cardiac cycle. RESULTS: A total of 48 vessel segments in 48 patients were randomized, with 24 receiving bioadaptor and 24 receiving DES. In within-group paired analyses, the bioadaptor group showed a significant improvement in torsion flexibility from 1 to 12 months, whereas no significant change was observed in the DES group. Although curvature and path flexibility increased numerically in the bioadaptor group, these within-group differences were not statistically significant. However, when comparing the magnitude of change between groups, the increase in path flexibility was significantly greater with the bioadaptor than with DES, indicating a superior restoration of 3-dimensional vessel motion. CONCLUSIONS: The novel bioadaptor technology demonstrated favorable restoration of 3-dimensional dynamic geometry of the treated vessel segment 12 months after implantation, in comparison with traditional DES. These initial mechanistic findings suggest a potential explanation for the favorable clinical outcomes observed in prior trials, and our analytical approach may offer new insights to guide future vascular implant designs and evaluations. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04936191.
- 1 February 2026
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 19 (2) , e016191
Dynamic Change of Coronary Artery Geometry After Bioadaptor Implantation: A Single-blind Randomized Controlled Trial
BACKGROUND: The DynamX bioadaptor, a novel coronary implant, is designed to restore vessel function when the thin polymer coating covering the helical strands resorbs 6 months post-percutaneous coronary intervention. We aimed to evaluate vessel conformability 1 year after percutaneous coronary intervention with the bioadaptor, compared with conventional drug-eluting stents (DESs). METHODS: Vessel segments were 1:1 randomized to a novolimus-eluting bioadaptor or a durable polymer novolimus-eluting second-generation DES. Coronary computed tomography angiography was performed at 1 and 12 months post-implantation, and the 3-dimensional geometry of the treated segments in coronary computed tomography angiography was analyzed. The primary outcome was the change in dynamic vessel geometry, including curvature flexibility (bending motion), torsion flexibility (twisting motion), and path flexibility (3-dimensional motion) of the treated segment during the cardiac cycle. RESULTS: A total of 48 vessel segments in 48 patients were randomized, with 24 receiving bioadaptor and 24 receiving DES. In within-group paired analyses, the bioadaptor group showed a significant improvement in torsion flexibility from 1 to 12 months, whereas no significant change was observed in the DES group. Although curvature and path flexibility increased numerically in the bioadaptor group, these within-group differences were not statistically significant. However, when comparing the magnitude of change between groups, the increase in path flexibility was significantly greater with the bioadaptor than with DES, indicating a superior restoration of 3-dimensional vessel motion. CONCLUSIONS: The novel bioadaptor technology demonstrated favorable restoration of 3-dimensional dynamic geometry of the treated vessel segment 12 months after implantation, in comparison with traditional DES. These initial mechanistic findings suggest a potential explanation for the favorable clinical outcomes observed in prior trials, and our analytical approach may offer new insights to guide future vascular implant designs and evaluations. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT04936191.
- Open Access
- 27 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (2) , ytag032
Valve-in-valve transcatheter aortic valve replacement for bioprosthetic valve failure complicated by hypo-attenuated leaflet thickening: a case report
Background: Bioprosthetic valve dysfunction (BVD) is a common complication after aortic valve replacement. Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) offers a less invasive alternative to redo surgery. However, research on hypo-attenuated leaflet thickening (HALT) following ViV-TAVR remains limited. Case summary: A 74-year-old man with hypertension, transient ischaemic attack, and prior aortic and mitral bioprosthetic valve replacements for infective endocarditis 10 years ago demonstrated elevated transaortic pressure gradients and severely reduced effective orifice area index without paravalvular leakage on transthoracic echocardiography (TTE) despite initial asymptomatic status. Serial TTE monitoring every 6 months initially suggested patient-prosthesis mismatch, later progressing to structural valve degeneration. However, transoesophageal echocardiography revealed no evident leaflet thickening or limited aortic valve opening. Furthermore, computed tomography (CT) confirmed proper aortic valve opening and further excluded pannus and thrombus. Due to symptom progression, worsening echocardiographic haemodynamics, and elevated NT-proBNP, ViV-TAVR with pre-procedural balloon valve fracture was performed, resulting in improved haemodynamics at 1-month follow-up. Post-procedural follow-up CT at 5 months revealed HALT, accompanied by only a mild elevation in peak aortic flow velocity on transthoracic echocardiography. Warfarin at a dose of 1 mg daily was initiated, resulting in thrombus resolution on 6-month follow-up CT, after which therapy was continued with regular TTE monitoring. Discussion: This case highlights the importance of multimodality and serial imaging in diagnosing and managing complex BVD. The observed HALT resolution raises questions about anticoagulation strategies after ViV-TAVR, especially in the absence of definitive guidelines.
- 27 January 2026
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 10 (2) , ytag032
Open AccessValve-in-valve transcatheter aortic valve replacement for bioprosthetic valve failure complicated by hypo-attenuated leaflet thickening: a case report
Background: Bioprosthetic valve dysfunction (BVD) is a common complication after aortic valve replacement. Valve-in-valve transcatheter aortic valve replacement (ViV-TAVR) offers a less invasive alternative to redo surgery. However, research on hypo-attenuated leaflet thickening (HALT) following ViV-TAVR remains limited. Case summary: A 74-year-old man with hypertension, transient ischaemic attack, and prior aortic and mitral bioprosthetic valve replacements for infective endocarditis 10 years ago demonstrated elevated transaortic pressure gradients and severely reduced effective orifice area index without paravalvular leakage on transthoracic echocardiography (TTE) despite initial asymptomatic status. Serial TTE monitoring every 6 months initially suggested patient-prosthesis mismatch, later progressing to structural valve degeneration. However, transoesophageal echocardiography revealed no evident leaflet thickening or limited aortic valve opening. Furthermore, computed tomography (CT) confirmed proper aortic valve opening and further excluded pannus and thrombus. Due to symptom progression, worsening echocardiographic haemodynamics, and elevated NT-proBNP, ViV-TAVR with pre-procedural balloon valve fracture was performed, resulting in improved haemodynamics at 1-month follow-up. Post-procedural follow-up CT at 5 months revealed HALT, accompanied by only a mild elevation in peak aortic flow velocity on transthoracic echocardiography. Warfarin at a dose of 1 mg daily was initiated, resulting in thrombus resolution on 6-month follow-up CT, after which therapy was continued with regular TTE monitoring. Discussion: This case highlights the importance of multimodality and serial imaging in diagnosing and managing complex BVD. The observed HALT resolution raises questions about anticoagulation strategies after ViV-TAVR, especially in the absence of definitive guidelines.
- Open Access
- 22 October 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (11)
Endovascular repair of iliac vein perforation during trans-septal mitral valve-in-valve replacement: a case report
Background: Transcatheter mitral valve-in-valve (TMViV) replacement via trans-septal access is a less invasive alternative for high-risk patients with degenerated bioprosthetic valves. However, life-threatening venous injuries may occur, though they are rarely reported. Case summary: A 73-year-old man with a prior mitral bioprosthetic valve replacement presented with heart failure due to severe prosthetic stenosis. TMViV was planned via a trans-septal approach. During device advancement through the right iliac vein, a massive venous perforation occurred, resulting in haemorrhagic shock. The cause was likely unrecognized venous calcification. Emergent endovascular repair with covered stents successfully stabilized the patient. Discussion: This case highlights the risk of catastrophic venous complications during trans-septal TMViV procedures, particularly in patients with venous calcification. Prompt recognition and endovascular intervention can be life-saving in such rare but critical scenarios.
- 22 October 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (11)
Open AccessEndovascular repair of iliac vein perforation during trans-septal mitral valve-in-valve replacement: a case report
Background: Transcatheter mitral valve-in-valve (TMViV) replacement via trans-septal access is a less invasive alternative for high-risk patients with degenerated bioprosthetic valves. However, life-threatening venous injuries may occur, though they are rarely reported. Case summary: A 73-year-old man with a prior mitral bioprosthetic valve replacement presented with heart failure due to severe prosthetic stenosis. TMViV was planned via a trans-septal approach. During device advancement through the right iliac vein, a massive venous perforation occurred, resulting in haemorrhagic shock. The cause was likely unrecognized venous calcification. Emergent endovascular repair with covered stents successfully stabilized the patient. Discussion: This case highlights the risk of catastrophic venous complications during trans-septal TMViV procedures, particularly in patients with venous calcification. Prompt recognition and endovascular intervention can be life-saving in such rare but critical scenarios.
- Open Access
- 16 September 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (10) , ytaf450
Transcatheter aortic valve replacement with JenaValve Trilogy system for aortic regurgitation following a David procedure: a case report
Background: Valve-sparing aortic root replacement (VSARR), also known as the David procedure, is a preferred surgical option for patients with aortic root aneurysms, offering preservation of the native valve and avoidance of mechanical valve replacement with lifelong anticoagulation. However, long-term durability remains a concern, with progressive aortic regurgitation (AR) occurring in up to 20% of cases. Redo surgical valve replacement is standard for failed VSARR, but transcatheter aortic valve replacement (TAVR) has emerged as a less invasive alternative for high-risk patients, despite technical challenges in non-calcified anatomy. This case highlights the first reported use of the JenaValve Trilogy system to treat post-David procedure AR. Case summary: A 71-year-old female developed severe AR ten years after undergoing a David procedure for a sinus of Valsalva aneurysm. Echocardiography showed eccentric AR due to left and non-coronary cusp malcoaptation, with an effective regurgitant orifice of 0.28 cm². Due to comorbidities and patient preference, TAVR was selected over surgical redo. A 23-mm Trilogy JenaValve was implanted via transfemoral access under conscious sedation. Post-procedural aortogram confirmed successful deployment and absence of residual regurgitation. The patient recovered uneventfully and was discharged on postoperative day five. Discussion: This case demonstrates the feasibility of the JenaValve Trilogy for managing post-VSARR AR, even in the absence of annular calcification. Its unique anchoring mechanism, which uses locators positioned within the sinuses, provides secure fixation in complex anatomies. This leaflet-locating design may offer a transcatheter option for patients with non-calcified anatomy. While promising, further clinical experience and long-term data are needed to better define the role of this system in failed valve-sparing repairs.
- 16 September 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (10) , ytaf450
Open AccessTranscatheter aortic valve replacement with JenaValve Trilogy system for aortic regurgitation following a David procedure: a case report
Background: Valve-sparing aortic root replacement (VSARR), also known as the David procedure, is a preferred surgical option for patients with aortic root aneurysms, offering preservation of the native valve and avoidance of mechanical valve replacement with lifelong anticoagulation. However, long-term durability remains a concern, with progressive aortic regurgitation (AR) occurring in up to 20% of cases. Redo surgical valve replacement is standard for failed VSARR, but transcatheter aortic valve replacement (TAVR) has emerged as a less invasive alternative for high-risk patients, despite technical challenges in non-calcified anatomy. This case highlights the first reported use of the JenaValve Trilogy system to treat post-David procedure AR. Case summary: A 71-year-old female developed severe AR ten years after undergoing a David procedure for a sinus of Valsalva aneurysm. Echocardiography showed eccentric AR due to left and non-coronary cusp malcoaptation, with an effective regurgitant orifice of 0.28 cm². Due to comorbidities and patient preference, TAVR was selected over surgical redo. A 23-mm Trilogy JenaValve was implanted via transfemoral access under conscious sedation. Post-procedural aortogram confirmed successful deployment and absence of residual regurgitation. The patient recovered uneventfully and was discharged on postoperative day five. Discussion: This case demonstrates the feasibility of the JenaValve Trilogy for managing post-VSARR AR, even in the absence of annular calcification. Its unique anchoring mechanism, which uses locators positioned within the sinuses, provides secure fixation in complex anatomies. This leaflet-locating design may offer a transcatheter option for patients with non-calcified anatomy. While promising, further clinical experience and long-term data are needed to better define the role of this system in failed valve-sparing repairs.
- 6 September 2024
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 41 (1) , 12-20
Dual ProGlide vs ProGlide and Angio-Seal for Femoral Access Hemostasis After Transcatheter Aortic Valve Replacement: A Randomised Comparative Trial
- 6 September 2024
- Published by Elsevier in Canadian Journal of Cardiology
- Vol. 41 (1) , 12-20
Dual ProGlide vs ProGlide and Angio-Seal for Femoral Access Hemostasis After Transcatheter Aortic Valve Replacement: A Randomised Comparative Trial
- Open Access
- 6 June 2024
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 21 (1) , 51-59
Plasma Angiopoietin-like Protein 4 as a Novel Biomarker Predicting 10-year Mortality in a Community-based Population: A Longitudinal Cohort Study
Introduction: Angiopoietin-like protein 4 (ANGPTL4) is a hepatokine implicated in fat metabolism regulation. Its genetic inactivation has been associated with improved glucose homeostasis, while elevated plasma ANGPTL4 levels are observed in diabetic and obese individuals. However, the potential link between ANGPTL4 and diabetes- or obesity-related complications remains uncertain. This study aimed to explore whether plasma ANGPTL4 levels could serve as predictors of cancer mortality, cardiovascular mortality, and all-cause mortality in a community-based cohort.Material and methods: A community-based cohort study was conducted, where fasting plasma ANGPTL4 concentrations were measured at baseline, and vital status was ascertained through linkage with the National Health Insurance Research Database in Taiwan.Results: During a 10.46-year follow-up period, 29 (2.49%) of the 1163 participants died. Subjects within the highest tertile of plasma ANGPTL4 levels exhibited the lowest survival rate. In unadjusted models, plasma ANGPTL4 significantly predicted all-cause mortality, cancer mortality, and cardiovascular or cancer-related mortality. Upon adjustment for confounders including age, sex, smoking, BMI, hypertension, DM, and renal function, each standard deviation increase in plasma ANGPTL4 was associated with HRs of 1.35 (95% CI 1.01-1.80, p<0.05) for all-cause mortality, 1.41 (95% CI 0.94-2.10, p=0.094) for cancer mortality, and 1.40 (95% CI 1.02-1.94, p<0.05) for cardiovascular or cancer-related mortality. Additionally, plasma ANGPTL4 contributed more significantly to predicting cardiovascular or cancer-related mortality and all-cause mortality compared to other predictors, such as sex, smoking, BMI, history of hypertension, history of diabetes, and eGFR.Conclusions: Plasma ANGPTL4 emerges as a promising biomarker capable of predicting 10-year mortality and enhancing risk prediction beyond established risk factors.
- 6 June 2024
- Published by Termedia Sp. z.o.o. in Archives of Medical Science
- Vol. 21 (1) , 51-59
Open AccessPlasma Angiopoietin-like Protein 4 as a Novel Biomarker Predicting 10-year Mortality in a Community-based Population: A Longitudinal Cohort Study
Introduction: Angiopoietin-like protein 4 (ANGPTL4) is a hepatokine implicated in fat metabolism regulation. Its genetic inactivation has been associated with improved glucose homeostasis, while elevated plasma ANGPTL4 levels are observed in diabetic and obese individuals. However, the potential link between ANGPTL4 and diabetes- or obesity-related complications remains uncertain. This study aimed to explore whether plasma ANGPTL4 levels could serve as predictors of cancer mortality, cardiovascular mortality, and all-cause mortality in a community-based cohort.Material and methods: A community-based cohort study was conducted, where fasting plasma ANGPTL4 concentrations were measured at baseline, and vital status was ascertained through linkage with the National Health Insurance Research Database in Taiwan.Results: During a 10.46-year follow-up period, 29 (2.49%) of the 1163 participants died. Subjects within the highest tertile of plasma ANGPTL4 levels exhibited the lowest survival rate. In unadjusted models, plasma ANGPTL4 significantly predicted all-cause mortality, cancer mortality, and cardiovascular or cancer-related mortality. Upon adjustment for confounders including age, sex, smoking, BMI, hypertension, DM, and renal function, each standard deviation increase in plasma ANGPTL4 was associated with HRs of 1.35 (95% CI 1.01-1.80, p<0.05) for all-cause mortality, 1.41 (95% CI 0.94-2.10, p=0.094) for cancer mortality, and 1.40 (95% CI 1.02-1.94, p<0.05) for cardiovascular or cancer-related mortality. Additionally, plasma ANGPTL4 contributed more significantly to predicting cardiovascular or cancer-related mortality and all-cause mortality compared to other predictors, such as sex, smoking, BMI, history of hypertension, history of diabetes, and eGFR.Conclusions: Plasma ANGPTL4 emerges as a promising biomarker capable of predicting 10-year mortality and enhancing risk prediction beyond established risk factors.
- Open Access
- 6 November 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Results of streamlining TAVR procedure towards a minimalist approach: a single center experience in Taiwan
Trans-femoral transcatheter aortic valve replacement (TF-TAVR) performed under conscious sedation (LACS) is not yet become routine practice in Taiwan. We aimed to compared the results between patients received general anesthesia (GA) versus LACS. Our cohort was divided into 3 groups: initial 48 patients received TF-TAVR under routine GA (GA group), subsequent 50 patients under routine LACS (LACS group 1), and recent 125 patients under LACS (LACS group 2). The baseline, procedural characteristics and all outcomes were prospectively collected and retrospectively compared. From Sep 2010 to July 2019, a total of 223 patients were included. The procedure time (157.6 ± 39.4 min vs 131.6 ± 30.3 vs 95.2 ± 40.0, < 0.0001), contrast medium consumption (245.6 ± 92.6 ml vs 207.8 ± 77.9 vs 175.1 ± 64.6, < 0.0001), length of intensive care unit (2 [1–5] days vs 2 [1–3] vs 1 [1–1], P = 0.0001) and hospital stay (9 [7–13] days vs 8 [6–11] vs 6 [5–9], P = 0.0001) decreased significantly with LACS, combined with a trend of less hospital acquired pneumonia (12.5% vs 6.0% vs 5.6%, P = 0.427). 1-year survival rate were also different among 3 groups (83.3% vs 90.0% vs 93.6%, P = 0.053). In our single center experience, a “minimalist” approach of TF-TAVR procedure resulted in less medical resources usage, along with more favorable clinical outcomes.
- 6 November 2023
- Published by Springer Nature in Scientific Reports
- Vol. 13 (1) , 1-7
Open AccessResults of streamlining TAVR procedure towards a minimalist approach: a single center experience in Taiwan
Trans-femoral transcatheter aortic valve replacement (TF-TAVR) performed under conscious sedation (LACS) is not yet become routine practice in Taiwan. We aimed to compared the results between patients received general anesthesia (GA) versus LACS. Our cohort was divided into 3 groups: initial 48 patients received TF-TAVR under routine GA (GA group), subsequent 50 patients under routine LACS (LACS group 1), and recent 125 patients under LACS (LACS group 2). The baseline, procedural characteristics and all outcomes were prospectively collected and retrospectively compared. From Sep 2010 to July 2019, a total of 223 patients were included. The procedure time (157.6 ± 39.4 min vs 131.6 ± 30.3 vs 95.2 ± 40.0, < 0.0001), contrast medium consumption (245.6 ± 92.6 ml vs 207.8 ± 77.9 vs 175.1 ± 64.6, < 0.0001), length of intensive care unit (2 [1–5] days vs 2 [1–3] vs 1 [1–1], P = 0.0001) and hospital stay (9 [7–13] days vs 8 [6–11] vs 6 [5–9], P = 0.0001) decreased significantly with LACS, combined with a trend of less hospital acquired pneumonia (12.5% vs 6.0% vs 5.6%, P = 0.427). 1-year survival rate were also different among 3 groups (83.3% vs 90.0% vs 93.6%, P = 0.053). In our single center experience, a “minimalist” approach of TF-TAVR procedure resulted in less medical resources usage, along with more favorable clinical outcomes.
Impact of leaflet thrombosis on valve haemodynamic status after transcatheter aortic valve replacement
Objectives The effect of subclinical leaflet thrombosis, characterised by hypoattenuated leaflet thickening (HALT), on the valve haemodynamic function and durability of the bioprosthetic valve, is not yet determined. We determined the impact of HALT on valve haemodynamics after transcatheter aortic valve replacement (TAVR) and the predictors of haemodynamic structural valve deterioration (SVD). Methods The Anticoagulation vs Dual Antiplatelet Therapy for Prevention of Leaflet Thrombosis and Cerebral Embolization after Transcatheter Aortic Valve Replacement(ADAPT-TAVR) trial is a multicenter, randomised trial that compared edoxaban and dual antiplatelet therapy in patients who had undergone successful TAVR. The presence of HALT was evaluated by four-dimensional CT at 6 months and serial echocardiography performed at baseline, immediately post-TAVR and after 6 months. SVD was defined as at least one of the following: (1) mean transprosthetic gradient ≥20 mm Hg, (2) change in the mean gradient ≥10 mm Hg from baseline, or (3) new or increase in intraprosthetic aortic regurgitation of at least ≥1 grade, resulting in moderate or greater regurgitation. Results At 6 months, HALT was found in 30 of 211 (14.2%) patients. The presence of HALT did not significantly affect aortic valve mean gradients (with vs without HALT; 14.0±4.8 mm Hg vs 13.7±5.5 mm Hg; p=0.74) at 6 months. SVD was reported in 30 of 206 patients (14.6%) at 6-month follow-up echocardiography. Older age (OR: 1.138; 95% CI: 1.019 to 1.293; p=0.033), use of aortic valve size ≤23 mm (OR: 6.254; 95% CI: 2.230 to 20.569; p=0.001) and mean post-TAVR pressure gradient (OR: 1.233; 95% CI: 1.123 to 1.371; pConclusions In patients who had undergone successful TAVR, aortic valve haemodynamic status was not influenced by the presence of HALT. Although HALT was not a predictor of haemodynamic SVD at 6 months, it warrants further longer-term follow-up to evaluate the effect on long-term valve durability. Trial registration number NCT03284827 (https://www.clinicaltrials.gov).
Impact of leaflet thrombosis on valve haemodynamic status after transcatheter aortic valve replacement
Objectives The effect of subclinical leaflet thrombosis, characterised by hypoattenuated leaflet thickening (HALT), on the valve haemodynamic function and durability of the bioprosthetic valve, is not yet determined. We determined the impact of HALT on valve haemodynamics after transcatheter aortic valve replacement (TAVR) and the predictors of haemodynamic structural valve deterioration (SVD). Methods The Anticoagulation vs Dual Antiplatelet Therapy for Prevention of Leaflet Thrombosis and Cerebral Embolization after Transcatheter Aortic Valve Replacement(ADAPT-TAVR) trial is a multicenter, randomised trial that compared edoxaban and dual antiplatelet therapy in patients who had undergone successful TAVR. The presence of HALT was evaluated by four-dimensional CT at 6 months and serial echocardiography performed at baseline, immediately post-TAVR and after 6 months. SVD was defined as at least one of the following: (1) mean transprosthetic gradient ≥20 mm Hg, (2) change in the mean gradient ≥10 mm Hg from baseline, or (3) new or increase in intraprosthetic aortic regurgitation of at least ≥1 grade, resulting in moderate or greater regurgitation. Results At 6 months, HALT was found in 30 of 211 (14.2%) patients. The presence of HALT did not significantly affect aortic valve mean gradients (with vs without HALT; 14.0±4.8 mm Hg vs 13.7±5.5 mm Hg; p=0.74) at 6 months. SVD was reported in 30 of 206 patients (14.6%) at 6-month follow-up echocardiography. Older age (OR: 1.138; 95% CI: 1.019 to 1.293; p=0.033), use of aortic valve size ≤23 mm (OR: 6.254; 95% CI: 2.230 to 20.569; p=0.001) and mean post-TAVR pressure gradient (OR: 1.233; 95% CI: 1.123 to 1.371; pConclusions In patients who had undergone successful TAVR, aortic valve haemodynamic status was not influenced by the presence of HALT. Although HALT was not a predictor of haemodynamic SVD at 6 months, it warrants further longer-term follow-up to evaluate the effect on long-term valve durability. Trial registration number NCT03284827 (https://www.clinicaltrials.gov).