Jamil A. K. Addas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jamil A. K. Addas has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
Abdullah Alabousi
Department of Radiology, McMaster University, St. Joseph's Healthcare Hamilton, Hamilton, ON
1 shared publicationArshdeep Sidhu
Department of Vascular and Interventional Radiology, University Health Network, Toronto, Canada
1 shared publicationDaniyal N. Mahmood
Division of Vascular Surgery, University Health Network, Toronto, Canada
1 shared publicationKhaled Almohaimede
Department of Medical Imaging, University of Toronto, Toronto, ON
1 shared publicationKong Teng Tan
Department of Vascular and Interventional Radiology, University Health Network, Toronto, Canada
1 shared publicationMaral Ouzounian
Division of Cardiovascular Surgery, University Health Network, Toronto, Canada
1 shared publication
Latest Publications
- 4 August 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (10) , 1462-1469
Minimally Invasive Segmental Artery Coil Embolization (MISACE) Prior to Endovascular Thoracoabdominal Aortic Aneurysm Repair
Purpose Minimally Invasive Segmental Artery Coil Embolization (MISACE) is a novel approach to reduce paraplegia risk in Thoracoabdominal aortic aneurysm (TAAA) repair with limited data. We report our experience with MISACE as a method of spinal cord pre-conditioning to prevent spinal cord ischemia following endovascular repair of TAAA. Material and Methods A retrospective analysis of 17 patients who had an attempted MISACE prior to endovascular TAAA repair with mean follow-up of 350 days (2017–2020). Baseline patient and aneurysm characteristics along with procedural technique and outcomes were analyzed. Results Mean age of 69 years and 76.5% were males. TAAA Crawford classification were II, n = 6 (35.3%), III, n = 4 (23.5%) and IV, n = 5 (29.4%). The mean aortic diameter was 70.6 ± 10.9 mm. Staged repair was performed on 9 patients. Technically successful embolization occurred in 14 patients (82.4%) and was unsuccessful in 3 patients. The median number of embolized arteries was 3 and 71% of the target arteries were between T9 and T12. Mean fluoroscopy time was 51.5 ± 22.5 min and mean contrast volume used was 132.8 ± 56.1 mL. Average number of catheters used was 4.6 and 3.5 wires. No complications related to the procedure. Mean interval between embolization to endovascular TAAA repair was 51.2 days (5–110 days). All patients received spinal drainage at the time of repair. Postoperatively, 2/14 of patients developed paraparesis in the MISACE successful group and 1/3 patients developed paraplegia in the unsuccessful group. Conclusions MISACE is a promising strategy to prevent SCI. This data demonstrates the technique is feasible and safe but anatomic challenges remain.
- 4 August 2022
- Published by Springer Nature in CardioVascular and Interventional Radiology
- Vol. 45 (10) , 1462-1469
Minimally Invasive Segmental Artery Coil Embolization (MISACE) Prior to Endovascular Thoracoabdominal Aortic Aneurysm Repair
Purpose Minimally Invasive Segmental Artery Coil Embolization (MISACE) is a novel approach to reduce paraplegia risk in Thoracoabdominal aortic aneurysm (TAAA) repair with limited data. We report our experience with MISACE as a method of spinal cord pre-conditioning to prevent spinal cord ischemia following endovascular repair of TAAA. Material and Methods A retrospective analysis of 17 patients who had an attempted MISACE prior to endovascular TAAA repair with mean follow-up of 350 days (2017–2020). Baseline patient and aneurysm characteristics along with procedural technique and outcomes were analyzed. Results Mean age of 69 years and 76.5% were males. TAAA Crawford classification were II, n = 6 (35.3%), III, n = 4 (23.5%) and IV, n = 5 (29.4%). The mean aortic diameter was 70.6 ± 10.9 mm. Staged repair was performed on 9 patients. Technically successful embolization occurred in 14 patients (82.4%) and was unsuccessful in 3 patients. The median number of embolized arteries was 3 and 71% of the target arteries were between T9 and T12. Mean fluoroscopy time was 51.5 ± 22.5 min and mean contrast volume used was 132.8 ± 56.1 mL. Average number of catheters used was 4.6 and 3.5 wires. No complications related to the procedure. Mean interval between embolization to endovascular TAAA repair was 51.2 days (5–110 days). All patients received spinal drainage at the time of repair. Postoperatively, 2/14 of patients developed paraparesis in the MISACE successful group and 1/3 patients developed paraplegia in the unsuccessful group. Conclusions MISACE is a promising strategy to prevent SCI. This data demonstrates the technique is feasible and safe but anatomic challenges remain.
- 1 September 2021
- Published by Elsevier in Journal of Obstetrics and Gynaecology Canada
- Vol. 43 (9) , 1055-1061
Evaluating the Transvaginal Ultrasound Diagnostic Criteria for Abnormal First-Trimester Pregnancy With Follow-Up Into the Third Trimester and Validation of Results
- 1 September 2021
- Published by Elsevier in Journal of Obstetrics and Gynaecology Canada
- Vol. 43 (9) , 1055-1061
Evaluating the Transvaginal Ultrasound Diagnostic Criteria for Abnormal First-Trimester Pregnancy With Follow-Up Into the Third Trimester and Validation of Results