Emmanuel Eghan-Acquah
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Emmanuel Eghan-Acquah has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Alireza Y. Bavil
School of Mechanical Engineering and Industrial Design, Griffith University
6 shared publications - David John Saxby
Griffith University
4 shared publications - Stefanie Feih
School of Engineering and Built Environment Griffith University Nathan Australia
4 shared publications - Bongju Kim
Dental Life Science Research Institute, Seoul National University Dental Hospital, Seoul 03080, Republic of Korea
3 shared publications Christopher P. Carty
The Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia; School of Medicine and Dentistry, Griffith University, Australia; Department of Orthopaedics, Children's Health Queensland Hospital and Health Service, Australia
3 shared publications- Christopher P. Carty
Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, QLD, Australia; School of Medicine and Dentistry, Griffith University, QLD, Australia; Department of Orthopedics, Children's Health Queensland Hospital and Health Service, QLD, Australia
3 shared publications
Latest Publications
- Open Access
- 17 June 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 213, 111813
A TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study
- 17 June 2026
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 213, 111813
Open AccessA TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study
- Open Access
- 27 November 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 521
Comparative analysis of the effects of blade plate retention versus removal on paediatric bone remodelling following proximal femoral osteotomy
Introduction: The decision to retain or remove blade plate implants after proximal femoral osteotomy (PFO) in paediatric patients remains contentious. While retention provides ongoing support, it increases stress shielding, potentially hindering bone remodelling and causing long-term complications. Conversely, early removal may restore normal mechanical loading and promote bone recovery. This study compares the effects of blade plate retention versus removal on bone density changes and implant risk of yield (RoY) over 36 months in a paediatric femur. Materials and methods: A personalised neuromusculoskeletal modelling and finite element analysis framework was developed using computed tomography scans and gait data. Using a strain energy-based remodelling analysis, the framework assessed changes in bone density and RoY for two clinical participants, comparing intact femurs with those retaining the implant for three years or having it removed after one year. Results: In both participants, implant retention diminished proximal femur remodelling. In P1, the average proximal bone density with implant increased by 0.11 g/cm 3 over 36 months, compared to 0.38 g/cm 3 in the intact model. In P2, the intact model’s average proximal density increased by 0.27 g/cm 3 versus 0.11 g/cm 3 with the implant. Implant removal after 12 months reactivated remodelling, yielding final density changes of 0.14 g/cm 3 (P1) and 0.21 g/cm 3 (P2). The RoY decreased over time, stabilising at 71–75% for blade plates and 56–62% for screws. Discussion: These findings highlight the detrimental effects of prolonged retention due to stress shielding. Recovery in bone density after removal suggests that early removal may mitigate adverse effects and promote healthier bone adaptation, informing clinical decisions in paediatric PFO.
- 27 November 2025
- Published by Springer Nature in Archives of orthopaedic and trauma surgery
- Vol. 145 (1) , 521
Open AccessComparative analysis of the effects of blade plate retention versus removal on paediatric bone remodelling following proximal femoral osteotomy
Introduction: The decision to retain or remove blade plate implants after proximal femoral osteotomy (PFO) in paediatric patients remains contentious. While retention provides ongoing support, it increases stress shielding, potentially hindering bone remodelling and causing long-term complications. Conversely, early removal may restore normal mechanical loading and promote bone recovery. This study compares the effects of blade plate retention versus removal on bone density changes and implant risk of yield (RoY) over 36 months in a paediatric femur. Materials and methods: A personalised neuromusculoskeletal modelling and finite element analysis framework was developed using computed tomography scans and gait data. Using a strain energy-based remodelling analysis, the framework assessed changes in bone density and RoY for two clinical participants, comparing intact femurs with those retaining the implant for three years or having it removed after one year. Results: In both participants, implant retention diminished proximal femur remodelling. In P1, the average proximal bone density with implant increased by 0.11 g/cm 3 over 36 months, compared to 0.38 g/cm 3 in the intact model. In P2, the intact model’s average proximal density increased by 0.27 g/cm 3 versus 0.11 g/cm 3 with the implant. Implant removal after 12 months reactivated remodelling, yielding final density changes of 0.14 g/cm 3 (P1) and 0.21 g/cm 3 (P2). The RoY decreased over time, stabilising at 71–75% for blade plates and 56–62% for screws. Discussion: These findings highlight the detrimental effects of prolonged retention due to stress shielding. Recovery in bone density after removal suggests that early removal may mitigate adverse effects and promote healthier bone adaptation, informing clinical decisions in paediatric PFO.
- Open Access
- 30 January 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 164, 106908
Evaluation of boundary conditions for predicting femoral bone-implant mechanics during gait in the absence of comprehensive medical imaging
- 30 January 2025
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 164, 106908
Open AccessEvaluation of boundary conditions for predicting femoral bone-implant mechanics during gait in the absence of comprehensive medical imaging
- Open Access
- 15 December 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 185, 109544
Simulated effects of surgical corrections on bone-implant micromotion and implant stresses in paediatric proximal femoral osteotomy
- 15 December 2024
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 185, 109544
Open AccessSimulated effects of surgical corrections on bone-implant micromotion and implant stresses in paediatric proximal femoral osteotomy
- Open Access
- 30 October 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 257, 108480
Enhancing biomechanical outcomes in proximal femoral osteotomy through optimised blade plate sizing: A neuromusculoskeletal-informed finite element analysis
- 30 October 2024
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 257, 108480
Open AccessEnhancing biomechanical outcomes in proximal femoral osteotomy through optimised blade plate sizing: A neuromusculoskeletal-informed finite element analysis
- Open Access
Biomechanical Efficacy and Effectiveness of Orthodontic Treatment with Transparent Aligners in Mild Crowding Dentition—A Finite Element Analysis
Orthodontic treatment increasingly involves transparent aligners; however, biomechanical analysis of their treatment effects under clinical conditions is lacking. We compared the biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners and of fixed appliances in simulated clinical orthodontic treatment conditions using orthodontic finite element (FE) models. In the FE analysis, we used Model Activation/De-Activation analysis to validate our method. Fixed appliances and 0.75-mm and 0.5-mm thick transparent aligners were applied to a tooth-alveolar bone FE model with lingually-inclined and axially-rotated central incisors. Compared to the fixed appliance, the 0.75-mm and 0.5-mm transparent aligners induced 5%, 38%, and 28% and 21%, 62%, and 34% less movement of the central incisors and principal stress of the periodontal ligament and of the alveolar bone, respectively, for lingual inclination correction. For axial-rotation correction, these aligners induced 22%, 37%, and 40% and 28%, 67%, and 48% less tooth movement and principal stress of the periodontal ligament and of the alveolar bone, respectively. In conclusion, transparent aligners induced less tooth movement, it is sufficient for orthodontic treatment, but 0.5-mm aligners should be used for only mild corrections. Additionally, the Model Activation/De-Activation analysis method is suitable for FE analysis of orthodontic treatment reflecting clinical treatment conditions.
Open AccessBiomechanical Efficacy and Effectiveness of Orthodontic Treatment with Transparent Aligners in Mild Crowding Dentition—A Finite Element Analysis
Orthodontic treatment increasingly involves transparent aligners; however, biomechanical analysis of their treatment effects under clinical conditions is lacking. We compared the biomechanical efficacy and effectiveness of orthodontic treatment with transparent aligners and of fixed appliances in simulated clinical orthodontic treatment conditions using orthodontic finite element (FE) models. In the FE analysis, we used Model Activation/De-Activation analysis to validate our method. Fixed appliances and 0.75-mm and 0.5-mm thick transparent aligners were applied to a tooth-alveolar bone FE model with lingually-inclined and axially-rotated central incisors. Compared to the fixed appliance, the 0.75-mm and 0.5-mm transparent aligners induced 5%, 38%, and 28% and 21%, 62%, and 34% less movement of the central incisors and principal stress of the periodontal ligament and of the alveolar bone, respectively, for lingual inclination correction. For axial-rotation correction, these aligners induced 22%, 37%, and 40% and 28%, 67%, and 48% less tooth movement and principal stress of the periodontal ligament and of the alveolar bone, respectively. In conclusion, transparent aligners induced less tooth movement, it is sufficient for orthodontic treatment, but 0.5-mm aligners should be used for only mild corrections. Additionally, the Model Activation/De-Activation analysis method is suitable for FE analysis of orthodontic treatment reflecting clinical treatment conditions.
- Open Access
Efficient Design of a Clear Aligner Attachment to Induce Bodily Tooth Movement in Orthodontic Treatment Using Finite Element Analysis
Clear aligner technology has become the preferred choice of orthodontic treatment for malocclusions for most adult patients due to their esthetic appeal and comfortability. However, limitations exist for aligner technology, such as corrections involving complex force systems. Composite attachments on the tooth surface are intended to enable active control of tooth movements. However, unintended tooth movements still occur. In this study, we present an effective attachment design of an attachment that can efficiently induce tooth movement by comparing and analyzing the movement and rotation of teeth between a general attachment and an overhanging attachment. The 3D finite element modes were constructed from CBCT data and used to analyze the distal displacement of the central incisor using 0.5- and 0.75-mm-thick aligners without an attachment, and with general and overhanging attachments. The results show that the aligner with the overhanging attachment can effectively reduce crown tipping and prevent axial rotation for an intended distal displacement of the central incisor. In all models, an aligner with or without attachments was not capable of preventing the lingual inclination of the tooth.
Open AccessEfficient Design of a Clear Aligner Attachment to Induce Bodily Tooth Movement in Orthodontic Treatment Using Finite Element Analysis
Clear aligner technology has become the preferred choice of orthodontic treatment for malocclusions for most adult patients due to their esthetic appeal and comfortability. However, limitations exist for aligner technology, such as corrections involving complex force systems. Composite attachments on the tooth surface are intended to enable active control of tooth movements. However, unintended tooth movements still occur. In this study, we present an effective attachment design of an attachment that can efficiently induce tooth movement by comparing and analyzing the movement and rotation of teeth between a general attachment and an overhanging attachment. The 3D finite element modes were constructed from CBCT data and used to analyze the distal displacement of the central incisor using 0.5- and 0.75-mm-thick aligners without an attachment, and with general and overhanging attachments. The results show that the aligner with the overhanging attachment can effectively reduce crown tipping and prevent axial rotation for an intended distal displacement of the central incisor. In all models, an aligner with or without attachments was not capable of preventing the lingual inclination of the tooth.
- Open Access
Comparative Analysis of Stress in the Periodontal Ligament and Center of Rotation in the Tooth after Orthodontic Treatment Depending on Clear Aligner Thickness—Finite Element Analysis Study
Lately, in orthodontic treatments, the use of transparent aligners for the correction of malocclusions has become prominent owing to their intrinsic advantages such as esthetics, comfort, and minimal maintenance. Attempts at improving upon this technology by varying various parameters to investigate the effects on treatments have been carried out by several researchers. Here, we aimed to investigate the biomechanical and clinical effects of aligner thickness on stress distributions in the periodontal ligament and changes in the tooth’s center of rotation. Dental finite element models comprising the cortical and cancellous bones, gingiva, teeth, and nonlinear viscoelastic periodontal ligaments were constructed, validated, and used together with aligner finite element models of different aligner thicknesses to achieve the goal of this study. The finite element analyses were conducted to simulate the actual orthodontic aligner treatment process for the correction of malocclusions by generating pre-stresses in the aligner and allowing the aligner stresses to relax to induce tooth movement. The results of the analyses showed that orthodontic treatment in lingual inclination and axial rotation with a 0.75 mm-thick aligner resulted in 6% and 0.03% higher principal stresses in the periodontal ligament than the same treatment using a 0.05 mm-thick aligner, respectively. Again, for both aligner thicknesses, the tooth’s center of rotation moved lingually and towards the root direction in lingual inclination, and diagonally from the long axis of the tooth in axial rotation. Taken together, orthodontic treatment for simple malocclusions using transparent aligners of different thicknesses will produce a similar effect on the principal stresses in the periodontal ligament and similar changes in the tooth’s center of rotation, as well as sufficient tooth movement. These findings provide orthodontists and researchers clinical and biomechanical evidence about the effect of transparent aligner thickness selection and its effect on orthodontic treatment.
Open AccessComparative Analysis of Stress in the Periodontal Ligament and Center of Rotation in the Tooth after Orthodontic Treatment Depending on Clear Aligner Thickness—Finite Element Analysis Study
Lately, in orthodontic treatments, the use of transparent aligners for the correction of malocclusions has become prominent owing to their intrinsic advantages such as esthetics, comfort, and minimal maintenance. Attempts at improving upon this technology by varying various parameters to investigate the effects on treatments have been carried out by several researchers. Here, we aimed to investigate the biomechanical and clinical effects of aligner thickness on stress distributions in the periodontal ligament and changes in the tooth’s center of rotation. Dental finite element models comprising the cortical and cancellous bones, gingiva, teeth, and nonlinear viscoelastic periodontal ligaments were constructed, validated, and used together with aligner finite element models of different aligner thicknesses to achieve the goal of this study. The finite element analyses were conducted to simulate the actual orthodontic aligner treatment process for the correction of malocclusions by generating pre-stresses in the aligner and allowing the aligner stresses to relax to induce tooth movement. The results of the analyses showed that orthodontic treatment in lingual inclination and axial rotation with a 0.75 mm-thick aligner resulted in 6% and 0.03% higher principal stresses in the periodontal ligament than the same treatment using a 0.05 mm-thick aligner, respectively. Again, for both aligner thicknesses, the tooth’s center of rotation moved lingually and towards the root direction in lingual inclination, and diagonally from the long axis of the tooth in axial rotation. Taken together, orthodontic treatment for simple malocclusions using transparent aligners of different thicknesses will produce a similar effect on the principal stresses in the periodontal ligament and similar changes in the tooth’s center of rotation, as well as sufficient tooth movement. These findings provide orthodontists and researchers clinical and biomechanical evidence about the effect of transparent aligner thickness selection and its effect on orthodontic treatment.