Sergei Obruchkov
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Sergei Obruchkov has a total of 74 co-authors. Here are the top co-authors by number of shared publications:
Petrik Galvosas
School of Chemical and Physical Sciences, Macdiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, New Zealand
4 shared publications- Petrik Galvosas
MacDiarmid Institute for Advanced Materials and Nanotechnology, School of Chemical and Physical Sciences Victoria University of Wellington Wellington New Zealand
3 shared publications Robin Dykstra
Victoria Univertsity of Wellington, Wellington, New Zealand(Aotearoa)
3 shared publications- Barry E. Paton
National Academy of Sciences of Ukraine
2 shared publications Dion G. Thomas
School of Chemical and Physical Sciences, Macdiarmid Institute for Advanced Materials and Nanotechnology, Victoria University of Wellington, New Zealand
2 shared publicationsFreya G. Harrison
Centre for Translational Research, University of Otago Wellington, New Zealand
2 shared publications
Latest Publications
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 671-680
Single-Sided Magnet System for Quantitative MR Relaxometry and Preclinical In-Vivo Monitoring
Objective: We have developed a single-sided magnet system that allows Magnetic Resonance relaxation and diffusion parameters to be measured. Methods: A single-sided magnet system has been developed, using an array of permanent magnets. The magnet positions are optimised to produce a B 0 magnetic field with a spot that is relatively homogenous and can project into a sample. NMR relaxometry experiments are used to measure quantitative parameters such as T 2 , T 1 and apparent diffusion coefficient (ADC) on samples on the benchtop. To explore preclinical application, we test whether it can detect changes during acute global cerebral hypoxia in an ovine model. Results: The magnet produces a 0.2 T field projected into the sample. Measurements of benchtop samples show that it can measure T 1 , T 2 and ADC, producing trends and values that are in line with literature measurements. In-vivo studies show a decrease in T 2 during cerebral hypoxia that recovers following normoxia. Conclusion: The single-sided MR system has the potential to allow non-invasive measurements of the brain. We also demonstrate that it can operate in a pre-clinical environment, allowing T 2 to be monitored during brain tissue hypoxia. Significance: MRI is a powerful technique for non-invasive diagnosis in the brain, but its application has been limited by the requirements for magnetic field strength and homogeneity that imaging methods have. The technology described in this study provides a portable alternative to acquiring clinically significant MR parameters without the need for traditional imaging equipment.
- 22 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 671-680
Single-Sided Magnet System for Quantitative MR Relaxometry and Preclinical In-Vivo Monitoring
Objective: We have developed a single-sided magnet system that allows Magnetic Resonance relaxation and diffusion parameters to be measured. Methods: A single-sided magnet system has been developed, using an array of permanent magnets. The magnet positions are optimised to produce a B 0 magnetic field with a spot that is relatively homogenous and can project into a sample. NMR relaxometry experiments are used to measure quantitative parameters such as T 2 , T 1 and apparent diffusion coefficient (ADC) on samples on the benchtop. To explore preclinical application, we test whether it can detect changes during acute global cerebral hypoxia in an ovine model. Results: The magnet produces a 0.2 T field projected into the sample. Measurements of benchtop samples show that it can measure T 1 , T 2 and ADC, producing trends and values that are in line with literature measurements. In-vivo studies show a decrease in T 2 during cerebral hypoxia that recovers following normoxia. Conclusion: The single-sided MR system has the potential to allow non-invasive measurements of the brain. We also demonstrate that it can operate in a pre-clinical environment, allowing T 2 to be monitored during brain tissue hypoxia. Significance: MRI is a powerful technique for non-invasive diagnosis in the brain, but its application has been limited by the requirements for magnetic field strength and homogeneity that imaging methods have. The technology described in this study provides a portable alternative to acquiring clinically significant MR parameters without the need for traditional imaging equipment.
- Open Access
- 2 February 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (5) , 805-815
Oxygen saturation-dependent effects on blood transverse relaxation at low fields
Objective: Blood oxygenation can be measured using magnetic resonance using the paramagnetic effect of deoxy-haemoglobin, which decreases the $$\textit{T}_{2}$$ relaxation time of blood. This $$\textit{T}_{2}$$ contrast has been well characterised at the $$\textit{B}_{{0}}$$ fields used in MRI (1.5 T and above). However, few studies have characterised this effect at lower magnetic fields. Here, the feasibility of blood oximetry at low field based on $$\textit{T}_{2}$$ changes that are within a physiological relevant range is explored. This study could be used for specifying requirements for construction of a monitoring device based on low field permanent magnet systems.Methods: A continuous flow circuit was used to control parameters such as oxygen saturation and temperature in a sample of blood. It flowed through a variable field magnet, where CPMG experiments were performed to measure its $$\textit{T}_{2}$$ . In addition, the oxygen saturation was monitored by an optical sensor for comparison with the $$\textit{T}_{2}$$ changes.Results: These results show that at low $$\textit{B}_{{0}}$$ fields, the change in blood $$\textit{T}_{2}$$ due to oxygenation is small, but still detectable. The data measured at low fields are also in agreement with theoretical models for the oxy-deoxy $$\textit{T}_{2}$$ effect.Conclusion: $$\textit{T}_{2}$$ changes in blood due to oxygenation were observed at fields as low as 0.1 T. These results suggest that low field NMR relaxometry devices around 0.3 T could be designed to detect changes in blood oxygenation.- 2 February 2022
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 35 (5) , 805-815
Open AccessOxygen saturation-dependent effects on blood transverse relaxation at low fields
Objective: Blood oxygenation can be measured using magnetic resonance using the paramagnetic effect of deoxy-haemoglobin, which decreases the $$\textit{T}_{2}$$ relaxation time of blood. This $$\textit{T}_{2}$$ contrast has been well characterised at the $$\textit{B}_{{0}}$$ fields used in MRI (1.5 T and above). However, few studies have characterised this effect at lower magnetic fields. Here, the feasibility of blood oximetry at low field based on $$\textit{T}_{2}$$ changes that are within a physiological relevant range is explored. This study could be used for specifying requirements for construction of a monitoring device based on low field permanent magnet systems.Methods: A continuous flow circuit was used to control parameters such as oxygen saturation and temperature in a sample of blood. It flowed through a variable field magnet, where CPMG experiments were performed to measure its $$\textit{T}_{2}$$ . In addition, the oxygen saturation was monitored by an optical sensor for comparison with the $$\textit{T}_{2}$$ changes.Results: These results show that at low $$\textit{B}_{{0}}$$ fields, the change in blood $$\textit{T}_{2}$$ due to oxygenation is small, but still detectable. The data measured at low fields are also in agreement with theoretical models for the oxy-deoxy $$\textit{T}_{2}$$ effect.Conclusion: $$\textit{T}_{2}$$ changes in blood due to oxygenation were observed at fields as low as 0.1 T. These results suggest that low field NMR relaxometry devices around 0.3 T could be designed to detect changes in blood oxygenation. - 1 January 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 322, 106852
Mobile low field magnetic resonance hardware development
- 1 January 2021
- Published by Elsevier in Journal of Magnetic Resonance
- Vol. 322, 106852
Mobile low field magnetic resonance hardware development
- Open Access
- 1 January 2019
- Published by Korean Society of Magnetic Resonance in Medicine in Investigative Magnetic Resonance Imaging
- Vol. 23 (3) , 179-201
Portable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays
Huang S, et al. Investig Magn Reson Imaging. 2019 Sep;23(3):179-201. https://doi.org/10.13104/imri.2019.23.3.179
- 1 January 2019
- Published by Korean Society of Magnetic Resonance in Medicine in Investigative Magnetic Resonance Imaging
- Vol. 23 (3) , 179-201
Open AccessPortable Low-Cost MRI System Based on Permanent Magnets/Magnet Arrays
Huang S, et al. Investig Magn Reson Imaging. 2019 Sep;23(3):179-201. https://doi.org/10.13104/imri.2019.23.3.179
- 30 January 2018
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 31 (4) , 553-564
Phosphorus magnetic resonance spectroscopic imaging using flyback echo planar readout trajectories
To present and evaluate a fast phosphorus magnetic resonance spectroscopic imaging (MRSI) sequence using echo planar spectroscopic imaging with flyback readout gradient trajectories.
- 30 January 2018
- Published by Springer Nature in Magnetic Resonance Materials in Physics, Biology and Medicine
- Vol. 31 (4) , 553-564
Phosphorus magnetic resonance spectroscopic imaging using flyback echo planar readout trajectories
To present and evaluate a fast phosphorus magnetic resonance spectroscopic imaging (MRSI) sequence using echo planar spectroscopic imaging with flyback readout gradient trajectories.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Construction of a PXIe platform for instrumentation development
PXIe is a modular instrumentation standard used in building electronic test equipment and modular laboratory instruments. Built on the PCIe bus standard, it provides high-speed transfer rates suitable for a wide range of applications. Instrumentation applications such as magnetic resonance imaging (MRI), generally has a high entry barrier due to high speed requirements and complexity. PXIe provides a good backplane option as the PCIe bus provides significant data bandwidth. However, the platform is inherently complex, usually contains proprietary IP and the solutions provided by vendors are often prohibitively expensive for some projects. To overcome these barriers, an open source PXIe platform has been developed. This consists of a PCIe I/O IP block for peripheral boards together with an associated device driver and application programmers interface (API) for the PCIe root complex hosted by the system controller. The design is capable of performing system controller initiated DMA transfers over PCIe in both directions. To further simplify system development, much use has been made of Xilinx based System on Module (SoM) units available from several vendors. Our example solution consists of (a) a PXIe system controller housing a Zynq based SoM mounted on a carrier board and running Linux and (b) a peripheral board based on an Artix SoM mounted on a carrier board and also hosting an FPGA Mezzanine Card (FMC) connector for further expansion.
- 1 December 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Construction of a PXIe platform for instrumentation development
PXIe is a modular instrumentation standard used in building electronic test equipment and modular laboratory instruments. Built on the PCIe bus standard, it provides high-speed transfer rates suitable for a wide range of applications. Instrumentation applications such as magnetic resonance imaging (MRI), generally has a high entry barrier due to high speed requirements and complexity. PXIe provides a good backplane option as the PCIe bus provides significant data bandwidth. However, the platform is inherently complex, usually contains proprietary IP and the solutions provided by vendors are often prohibitively expensive for some projects. To overcome these barriers, an open source PXIe platform has been developed. This consists of a PCIe I/O IP block for peripheral boards together with an associated device driver and application programmers interface (API) for the PCIe root complex hosted by the system controller. The design is capable of performing system controller initiated DMA transfers over PCIe in both directions. To further simplify system development, much use has been made of Xilinx based System on Module (SoM) units available from several vendors. Our example solution consists of (a) a PXIe system controller housing a Zynq based SoM mounted on a carrier board and running Linux and (b) a peripheral board based on an Artix SoM mounted on a carrier board and also hosting an FPGA Mezzanine Card (FMC) connector for further expansion.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3042-3044
A low-field portable magnetic resonance imaging system for head imaging
In this paper, we present the progress of the development and design of a portable low-field (<; 0.1 T) magnetic resonance imaging (MRI) scanner for head imaging. It includes the design, optimization, and implementation of Halbach-array-based permanent magnet array that provides B0 field with the merits of light weight and helium free, the work done on transmit and receive RF coils, the progress on the nonlinear imaging reconstruction algorithm based on a inhomogeneous B0 field provided by the magnet array, and the testing on a Magritek NMR spectrometer console.
- 1 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 3042-3044
A low-field portable magnetic resonance imaging system for head imaging
In this paper, we present the progress of the development and design of a portable low-field (<; 0.1 T) magnetic resonance imaging (MRI) scanner for head imaging. It includes the design, optimization, and implementation of Halbach-array-based permanent magnet array that provides B0 field with the merits of light weight and helium free, the work done on transmit and receive RF coils, the progress on the nonlinear imaging reconstruction algorithm based on a inhomogeneous B0 field provided by the magnet array, and the testing on a Magritek NMR spectrometer console.
- 1 July 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (7) , 074704
A compact Class D RF power amplifier for mobile nuclear magnetic resonance systems
A 20 MHz Class D amplifier with an output of 100 W of RF power has been developed. The compact size printed circuit board area of 50 cm2 and efficiency of 73% make it suitable for mobile nuclear magnetic resonance (NMR) systems. Test results show that the rise and ring down times of the amplifier are less than 0.2 μs, and it is capable of producing constant amplitude pulses as short as 2 μs. Experiments using a Carr Purcell Meiboom Gill pulse sequence with a NMR MOUSE sensor confirm that the Class D amplifier is suitable for mobile NMR applications.
- 1 July 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (7) , 074704
A compact Class D RF power amplifier for mobile nuclear magnetic resonance systems
A 20 MHz Class D amplifier with an output of 100 W of RF power has been developed. The compact size printed circuit board area of 50 cm2 and efficiency of 73% make it suitable for mobile nuclear magnetic resonance (NMR) systems. Test results show that the rise and ring down times of the amplifier are less than 0.2 μs, and it is capable of producing constant amplitude pulses as short as 2 μs. Experiments using a Carr Purcell Meiboom Gill pulse sequence with a NMR MOUSE sensor confirm that the Class D amplifier is suitable for mobile NMR applications.
- 10 April 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (1) , 501-510
Bone volume–to–total volume ratio measured in trabecular bone by single‐sided NMR devices
Purpose: Reduced bone strength is associated with a loss of bone mass, usually evaluated by dual‐energy X‐ray absorptiometry, although it is known that the bone microstructure also affects the bone strength. Here, a method is proposed to measure (in laboratory) the bone volume–to–total volume ratio by single‐sided NMR scanners, which is related to the microstructure of the trabecular bone.Methods: Three single‐sided scanners were used on animal bone samples. These low‐field, mobile, low‐cost devices are able to detect the NMR signal, regardless of the sample sizes, without the use of ionizing radiations, with the further advantage of signal localization offered by their intrinsic magnetic field gradients.Results: The performance of the different single‐sided scanners have been discussed. The results have been compared with bone volume–to–total volume ratio by micro CT and MRI, obtaining consistent values.Conclusions: Our results demonstrate the feasibility of the method for laboratory analyses, which are useful for measurements like porosity on bone specimens. This can be considered as the first step to develop an NMR method based on the use of a mobile single‐sided device, for the diagnosis of osteoporosis, through the acquisition of the signal from the appendicular skeleton, allowing for low‐cost, wide screening campaigns. Magn Reson Med 79:501–510, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
- 10 April 2017
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 79 (1) , 501-510
Bone volume–to–total volume ratio measured in trabecular bone by single‐sided NMR devices
Purpose: Reduced bone strength is associated with a loss of bone mass, usually evaluated by dual‐energy X‐ray absorptiometry, although it is known that the bone microstructure also affects the bone strength. Here, a method is proposed to measure (in laboratory) the bone volume–to–total volume ratio by single‐sided NMR scanners, which is related to the microstructure of the trabecular bone.Methods: Three single‐sided scanners were used on animal bone samples. These low‐field, mobile, low‐cost devices are able to detect the NMR signal, regardless of the sample sizes, without the use of ionizing radiations, with the further advantage of signal localization offered by their intrinsic magnetic field gradients.Results: The performance of the different single‐sided scanners have been discussed. The results have been compared with bone volume–to–total volume ratio by micro CT and MRI, obtaining consistent values.Conclusions: Our results demonstrate the feasibility of the method for laboratory analyses, which are useful for measurements like porosity on bone specimens. This can be considered as the first step to develop an NMR method based on the use of a mobile single‐sided device, for the diagnosis of osteoporosis, through the acquisition of the signal from the appendicular skeleton, allowing for low‐cost, wide screening campaigns. Magn Reson Med 79:501–510, 2018. © 2017 International Society for Magnetic Resonance in Medicine.