Encarnación Gutiérrez-Carretero
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Encarnación Gutiérrez-Carretero has a total of 93 co-authors. Here are the top co-authors by number of shared publications:
- Eduardo Arana-Rueda
Unidad de Arritmias, Servicio de Cardiología, Hospital Universitario Virgen del Rocío, Seville, Spain
5 shared publications - Antonio J. Muñoz García
University Hospital Virgen de la Victoria, Department of Cardiology, Malaga, Spain
3 shared publications - Antonio Ordóñez
Group of Cardiovascular Pathophysiology, Institute of Biomedicine of Seville, University Hospital of Virgen del Rocio/University of Seville/CSIC, Spain (I.G.-O., B.D.-L., C.A., L.E.-I., R.D.T., A.O.-F., T.S.).
3 shared publications - Arístides de Alarcón
Unidad Clínica de Enfermedades Infecciosas, Microbiología y Parasitología (UCEIMP), Instituto de Biomedicina de Sevilla (IBiS), Hospital Universitario Virgen del Rocío/CSIC/Universidad de Sevilla, 41013 Seville, Spain
3 shared publications - Isaac Pascual
University Hospital Central of Asturias University of Oviedo Oviedo Spain
3 shared publications - Manuel Francisco Jiménez Navarro
IBIMA Plataforma Bionand (Instituto de Investigación Biomédica de Málaga), Spain
3 shared publications
Latest Publications
- Open Access
- 7 March 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (3) , 537
Mortality and Costs of Cardiac Implantable Electronic Device (CIED) Infections According to the Therapeutic Approach: A Single-Center Cohort Study
Background: Cardiac device infections are serious adverse events associated with considerable morbidity and mortality, significant costs, and increased healthcare utilization. The aim of this study is to calculate the costs of treatment of cardiac implantable electrostimulation device (CIED)-related infections for different types of infection (local or systemic) and therapeutic approaches. Patients and Methods: Single-center cohort (1985–2018). The costs of the CIED-related infections were analyzed according to initial treatment (antimicrobial treatment exclusively, local approach, or transvenous lead extraction (TLE)). Total costs (including those for hospitalization stay, drugs, extraction material, and newly implanted devices) were assigned to each case until its final resolution. Results: A total of 380 cases (233 local and 147 systemic infections) were analyzed. The average cost of systemic infection was EUR 34,086, mainly due to hospitalization (78.5%; mean: 24 ± 14 days), with a mortality rate of 10.8%. Local infection had a mortality rate of 2.5% (mainly related to the extraction procedure) and an average cost of EUR 21,790, which was higher in patients with resynchronization therapy devices and defibrillators (46% of total costs). Surgical procedures limited to the pocket for local infections resulted in a high rate of recurrence (87%), evolved to systemic infections in 48 patients, and had a higher cost compared to TLE (EUR 42,978 vs. EUR 24,699; p < 0.01). Conclusions: The costs of treating CIED-related infections are high and mainly related to the type of treatment and length of hospitalization. Complete device removal is always the most effective approach and is a cost-saving strategy.
- 7 March 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (3) , 537
Open AccessMortality and Costs of Cardiac Implantable Electronic Device (CIED) Infections According to the Therapeutic Approach: A Single-Center Cohort Study
Background: Cardiac device infections are serious adverse events associated with considerable morbidity and mortality, significant costs, and increased healthcare utilization. The aim of this study is to calculate the costs of treatment of cardiac implantable electrostimulation device (CIED)-related infections for different types of infection (local or systemic) and therapeutic approaches. Patients and Methods: Single-center cohort (1985–2018). The costs of the CIED-related infections were analyzed according to initial treatment (antimicrobial treatment exclusively, local approach, or transvenous lead extraction (TLE)). Total costs (including those for hospitalization stay, drugs, extraction material, and newly implanted devices) were assigned to each case until its final resolution. Results: A total of 380 cases (233 local and 147 systemic infections) were analyzed. The average cost of systemic infection was EUR 34,086, mainly due to hospitalization (78.5%; mean: 24 ± 14 days), with a mortality rate of 10.8%. Local infection had a mortality rate of 2.5% (mainly related to the extraction procedure) and an average cost of EUR 21,790, which was higher in patients with resynchronization therapy devices and defibrillators (46% of total costs). Surgical procedures limited to the pocket for local infections resulted in a high rate of recurrence (87%), evolved to systemic infections in 48 patients, and had a higher cost compared to TLE (EUR 42,978 vs. EUR 24,699; p < 0.01). Conclusions: The costs of treating CIED-related infections are high and mainly related to the type of treatment and length of hospitalization. Complete device removal is always the most effective approach and is a cost-saving strategy.
- 6 January 2024
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 40 (S1) , 138-149
Infections of cardiac implantable electronic devices and how to improve transvenous lead extraction by the virtual reality
Introduction Infections in cardiac implantable electronic devices (CIED) are increasing over time and associated with substantially mortality and healthcare costs. The best approach is the complete removal of the system by transvenous lead extraction (TLE). However, when leads are more than 10 years old, this technique requires considerable expertise and failures with the result of abandoned leads or serious complications may occur. The aim of this study is to describe our experience using virtual and mixed reality in the preoperative planning of complex cases. Patients and methods Consecutive patients from a referral centre with CIED infections in which TLE was judged difficult. Synchronized computed tomography (CT) scan images were processed and transferred to a fully immersive virtual reality room and also to the operative room (mixed reality) for better guidance during the extracting procedure. Results Ten patients (seven with local and three with systemic infections) were preoperative evaluated. Processed images and virtual reality showed intense adherences of the leads to the veins, right ventricle, and right atrium endocardium and between them that preclude a difficult extraction and required a carefully planning and sometimes a different technical approach. The anticipated difficulty was confirmed by the higher times of fluoroscopy. All leads were extracted and no complications were registered. Conclusions Preoperative planning is essential for evaluation of TLE difficulty and prevention of unexpected situations. Virtual reality seems an estimable aid for operators in planning difficult cases and also an excellent tool for teaching.
- 6 January 2024
- Published by Springer Nature in Indian Journal of Thoracic and Cardiovascular Surgery
- Vol. 40 (S1) , 138-149
Infections of cardiac implantable electronic devices and how to improve transvenous lead extraction by the virtual reality
Introduction Infections in cardiac implantable electronic devices (CIED) are increasing over time and associated with substantially mortality and healthcare costs. The best approach is the complete removal of the system by transvenous lead extraction (TLE). However, when leads are more than 10 years old, this technique requires considerable expertise and failures with the result of abandoned leads or serious complications may occur. The aim of this study is to describe our experience using virtual and mixed reality in the preoperative planning of complex cases. Patients and methods Consecutive patients from a referral centre with CIED infections in which TLE was judged difficult. Synchronized computed tomography (CT) scan images were processed and transferred to a fully immersive virtual reality room and also to the operative room (mixed reality) for better guidance during the extracting procedure. Results Ten patients (seven with local and three with systemic infections) were preoperative evaluated. Processed images and virtual reality showed intense adherences of the leads to the veins, right ventricle, and right atrium endocardium and between them that preclude a difficult extraction and required a carefully planning and sometimes a different technical approach. The anticipated difficulty was confirmed by the higher times of fluoroscopy. All leads were extracted and no complications were registered. Conclusions Preoperative planning is essential for evaluation of TLE difficulty and prevention of unexpected situations. Virtual reality seems an estimable aid for operators in planning difficult cases and also an excellent tool for teaching.
- Open Access
- 9 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (9) , 2651
Infective Endocarditis in Diabetic Patients: A Different Profile with Prognostic Consequences
Background. Infective Endocarditis (IE) is a severe condition. Diabetes mellitus (DM) has been associated with a poor prognosis in other settings. Our aim was to describe the profile and prognosis of IE with and without DM and to analyze the prognostic relevance of DM-related organ damage. Methods. Retrospective analysis of the Spanish IE Registry (2008–2020). Results. The cohort comprises 5590 IE patients with a mean age of 65.0 ± 15.5 years; 3764 (67.3%) were male. DM was found in 1625 patients (29.1%) and 515 presented DM-related organ damage. DM prevalence during the first half of the study period was 27.6% vs. 30.6% in the last half, p = 0.015. Patients with DM presented higher in-hospital mortality than those without DM (521 [32.1%] vs. 924 [23.3%], p < 0.001) and higher one-year mortality (640 [39.4%] vs. 1131 [28.5%], p < 0.001). Among DM patients, organ damage was associated with higher in-hospital (200 [38.8%] vs. 321 [28.9%], p < 0.001) and one-year mortality (247 [48.0%] vs. 393 [35.4%], p < 0.001). Multivariate analyses showed an independent association of DM with in-hospital (odds ratio [OR] = 1.34, 95% confidence interval [CI]: 1.16–1.55, p < 0.001) and one-year mortality (OR = 1.38, 95% CI: 1.21–1.59, p < 0.001). Among DM patients, organ damage was independently associated with higher in-hospital (OR = 1.37, 95% CI: 1.06–1.76, p = 0.015) and one-year mortality (OR = 1.59, 95% CI = 1.26–2.01, p < 0.001) Conclusions. The prevalence of DM among patients with IE is increasing and is already above 30%. DM is independently associated with a poor prognosis, particularly in the case of DM with organ damage.
- 9 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (9) , 2651
Open AccessInfective Endocarditis in Diabetic Patients: A Different Profile with Prognostic Consequences
Background. Infective Endocarditis (IE) is a severe condition. Diabetes mellitus (DM) has been associated with a poor prognosis in other settings. Our aim was to describe the profile and prognosis of IE with and without DM and to analyze the prognostic relevance of DM-related organ damage. Methods. Retrospective analysis of the Spanish IE Registry (2008–2020). Results. The cohort comprises 5590 IE patients with a mean age of 65.0 ± 15.5 years; 3764 (67.3%) were male. DM was found in 1625 patients (29.1%) and 515 presented DM-related organ damage. DM prevalence during the first half of the study period was 27.6% vs. 30.6% in the last half, p = 0.015. Patients with DM presented higher in-hospital mortality than those without DM (521 [32.1%] vs. 924 [23.3%], p < 0.001) and higher one-year mortality (640 [39.4%] vs. 1131 [28.5%], p < 0.001). Among DM patients, organ damage was associated with higher in-hospital (200 [38.8%] vs. 321 [28.9%], p < 0.001) and one-year mortality (247 [48.0%] vs. 393 [35.4%], p < 0.001). Multivariate analyses showed an independent association of DM with in-hospital (odds ratio [OR] = 1.34, 95% confidence interval [CI]: 1.16–1.55, p < 0.001) and one-year mortality (OR = 1.38, 95% CI: 1.21–1.59, p < 0.001). Among DM patients, organ damage was independently associated with higher in-hospital (OR = 1.37, 95% CI: 1.06–1.76, p = 0.015) and one-year mortality (OR = 1.59, 95% CI = 1.26–2.01, p < 0.001) Conclusions. The prevalence of DM among patients with IE is increasing and is already above 30%. DM is independently associated with a poor prognosis, particularly in the case of DM with organ damage.
- 1 October 2021
- Published by Elsevier in European Journal of Internal Medicine
- Vol. 92, 71-78
Non-HACEK gram negative bacilli endocarditis: Analysis of a national prospective cohort.
- 1 October 2021
- Published by Elsevier in European Journal of Internal Medicine
- Vol. 92, 71-78
Non-HACEK gram negative bacilli endocarditis: Analysis of a national prospective cohort.
- Open Access
- 30 March 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (4) , 354
miR-30b-5p Downregulation as a Predictive Biomarker of Coronary In-Stent Restenosis
In-stent restenosis (ISR) is one of the main limitations of percutaneous coronary intervention (PCI) therapy with drug-eluting stents (DES) implantation. The aim of this study was to determine if circulating microRNAs (miRNAs) have diagnostic capability for determining ISR in a cohort of matched patients. Blood samples were collected from 55 patients who underwent previously PCI and were readmitted for a new coronary angiography. Patients were divided into subgroups comprising patients who presented ISR or not (non-ISR). A microarray analysis determined that up to 49 miRNAs were differentially expressed between ISR and non-ISR patients. Of these, 10 miRNAs are related to vascular smooth muscle and endothelial cells proliferation, migration, and differentiation, well-known hallmarks of vascular remodeling. Additionally, we identified that the expression of miR-30b-5p is significantly lower in serum samples of ISR patients, as compared to non-ISR. A further analysis demonstrated that miR-30b-5p provides better values of the receiver operator characteristic curve than other miRNAs and biochemical parameters. Finally, the in-silico analysis suggests that miR-30b-5p is predicted to target 62 genes involved in different signaling pathways involved in vascular remodeling. In conclusion, we determined for the first time that circulating mi-R30b-5p can reliably prognose restenosis in patient with implanted DES, which could be potentially helpful in the establishment of an early diagnosis and therapy of ISR.
- 30 March 2021
- Published by MDPI AG in Biomedicines
- Vol. 9 (4) , 354
Open AccessmiR-30b-5p Downregulation as a Predictive Biomarker of Coronary In-Stent Restenosis
In-stent restenosis (ISR) is one of the main limitations of percutaneous coronary intervention (PCI) therapy with drug-eluting stents (DES) implantation. The aim of this study was to determine if circulating microRNAs (miRNAs) have diagnostic capability for determining ISR in a cohort of matched patients. Blood samples were collected from 55 patients who underwent previously PCI and were readmitted for a new coronary angiography. Patients were divided into subgroups comprising patients who presented ISR or not (non-ISR). A microarray analysis determined that up to 49 miRNAs were differentially expressed between ISR and non-ISR patients. Of these, 10 miRNAs are related to vascular smooth muscle and endothelial cells proliferation, migration, and differentiation, well-known hallmarks of vascular remodeling. Additionally, we identified that the expression of miR-30b-5p is significantly lower in serum samples of ISR patients, as compared to non-ISR. A further analysis demonstrated that miR-30b-5p provides better values of the receiver operator characteristic curve than other miRNAs and biochemical parameters. Finally, the in-silico analysis suggests that miR-30b-5p is predicted to target 62 genes involved in different signaling pathways involved in vascular remodeling. In conclusion, we determined for the first time that circulating mi-R30b-5p can reliably prognose restenosis in patient with implanted DES, which could be potentially helpful in the establishment of an early diagnosis and therapy of ISR.
- 11 December 2020
- Published by Asociacion Espanola de Perfusionistas in Revista Española de Perfusión
- No. Supplement,p. 5-77
Guidelines for enhanced recovery after cardiac surgery. Consensus document of Spanish Societies of Anesthesia (SEDAR), Cardiovascular Surgery (SECCE) and Perfusionists (AEP)
The ERAS guidelines are intended to identify, disseminate and promote the implementation of the best, scientific evidence-based actions to decrease variability in clinical practice. The implementation of these practices in the global clinical process will promote better outcomes and the shortening of hospital and critical care unit stays, thereby resulting in a reduction in costs and in greater efficiency. After completing a systematic review at each of the points of the perioperative process in cardiac surgery, recommendations have been developed based on the best scientific evidence currently available with the consensus of the scientific societies involved.
- 11 December 2020
- Published by Asociacion Espanola de Perfusionistas in Revista Española de Perfusión
- No. Supplement,p. 5-77
Guidelines for enhanced recovery after cardiac surgery. Consensus document of Spanish Societies of Anesthesia (SEDAR), Cardiovascular Surgery (SECCE) and Perfusionists (AEP)
The ERAS guidelines are intended to identify, disseminate and promote the implementation of the best, scientific evidence-based actions to decrease variability in clinical practice. The implementation of these practices in the global clinical process will promote better outcomes and the shortening of hospital and critical care unit stays, thereby resulting in a reduction in costs and in greater efficiency. After completing a systematic review at each of the points of the perioperative process in cardiac surgery, recommendations have been developed based on the best scientific evidence currently available with the consensus of the scientific societies involved.
- 8 October 2020
- Published by IMR Press in The Heart Surgery Forum
- Vol. 23 (6) , E763-E769
Outcomes of Isolated Tricuspid Valve Surgery
Background: Isolated tricuspid valve surgery is a rarely performed procedure and traditionally is associated with a bad prognosis, although its clinical outcomes still are little known. The aim of this study was to assess the short- and long-term clinical outcomes obtained at our center after isolated tricuspid valve surgery as treatment for severe tricuspid regurgitation. Methods: This retrospective study included 71 consecutive patients with severe tricuspid regurgitation who underwent isolated tricuspid valve surgery between December 1996 and December 2017. Perioperative and long-term mortality, tricuspid valve reoperation, and functional class were analyzed after follow up. Results: Regarding surgery, 7% of patients received a De Vega annuloplasty, 14.1% an annuloplasty ring, 11.3% a mechanical prosthesis, and 67.6% a biological prosthesis. Perioperative mortality was 12.7% and no variable was shown to be predictive of this event. After a median follow up of 45.5 months, long-term mortality was 36.6%, and the multivariate analysis identified atrial fibrillation as the only predictor (Hazard Ratio 3.014, 95% confidence interval 1.06-8.566; P = 0.038). At the end of follow up, 63.6% of survivors had functional class I. Conclusions: Isolated tricuspid valve surgery was infrequent in our center. Perioperative mortality was high, as was long-term mortality. However, a high percentage of survivors were barely symptomatic after follow up.
- 8 October 2020
- Published by IMR Press in The Heart Surgery Forum
- Vol. 23 (6) , E763-E769
Outcomes of Isolated Tricuspid Valve Surgery
Background: Isolated tricuspid valve surgery is a rarely performed procedure and traditionally is associated with a bad prognosis, although its clinical outcomes still are little known. The aim of this study was to assess the short- and long-term clinical outcomes obtained at our center after isolated tricuspid valve surgery as treatment for severe tricuspid regurgitation. Methods: This retrospective study included 71 consecutive patients with severe tricuspid regurgitation who underwent isolated tricuspid valve surgery between December 1996 and December 2017. Perioperative and long-term mortality, tricuspid valve reoperation, and functional class were analyzed after follow up. Results: Regarding surgery, 7% of patients received a De Vega annuloplasty, 14.1% an annuloplasty ring, 11.3% a mechanical prosthesis, and 67.6% a biological prosthesis. Perioperative mortality was 12.7% and no variable was shown to be predictive of this event. After a median follow up of 45.5 months, long-term mortality was 36.6%, and the multivariate analysis identified atrial fibrillation as the only predictor (Hazard Ratio 3.014, 95% confidence interval 1.06-8.566; P = 0.038). At the end of follow up, 63.6% of survivors had functional class I. Conclusions: Isolated tricuspid valve surgery was infrequent in our center. Perioperative mortality was high, as was long-term mortality. However, a high percentage of survivors were barely symptomatic after follow up.
- Open Access
- 8 April 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (4) , 1051
Circulating miR-320a as a Predictive Biomarker for Left Ventricular Remodelling in STEMI Patients Undergoing Primary Percutaneous Coronary Intervention
Restoration of epicardial coronary blood flow, achieved by early reperfusion with primary percutaneous coronary intervention (PPCI), is the guideline recommended to treat patients with ST-segment-elevation myocardial infarction (STEMI). However, despite successful blood restoration, increasing numbers of patients develop left ventricular adverse remodelling (LVAR) and heart failure. Therefore, reliable prognostic biomarkers for LVAR in STEMI are urgently needed. Our aim was to investigate the role of circulating microRNAs (miRNAs) and their association with LVAR in STEMI patients following the PPCI procedure. We analysed the expression of circulating miRNAs in blood samples of 56 patients collected at admission and after revascularization (at 3, 6, 12 and 24 h). The associations between miRNAs and left ventricular end diastolic volumes at 6 months were estimated to detect LVAR. miRNAs were also analysed in samples isolated from peripheral blood mononuclear cells (PBMCs) and human myocardium of failing hearts. Kinetic analysis of miRNAs showed a fast time-dependent increase in miR-133a, miR-133b, miR-193b, miR-499, and miR-320a in STEMI patients compared to controls. Moreover, the expression of miR-29a, miR-29b, miR-324, miR-208, miR-423, miR-522, and miR-545 was differentially expressed even before PPCI in STEMI. Furthermore, the increase in circulating miR-320a and the decrease in its expression in PBMCs were significantly associated with LVAR and correlated with the expression of miR-320a in human failing myocardium from ischaemic origin. In conclusion, we determined the time course expression of new circulating miRNAs in patients with STEMI treated with PPCI and we showed that miR-320a was positively associated with LVAR.
- 8 April 2020
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 9 (4) , 1051
Open AccessCirculating miR-320a as a Predictive Biomarker for Left Ventricular Remodelling in STEMI Patients Undergoing Primary Percutaneous Coronary Intervention
Restoration of epicardial coronary blood flow, achieved by early reperfusion with primary percutaneous coronary intervention (PPCI), is the guideline recommended to treat patients with ST-segment-elevation myocardial infarction (STEMI). However, despite successful blood restoration, increasing numbers of patients develop left ventricular adverse remodelling (LVAR) and heart failure. Therefore, reliable prognostic biomarkers for LVAR in STEMI are urgently needed. Our aim was to investigate the role of circulating microRNAs (miRNAs) and their association with LVAR in STEMI patients following the PPCI procedure. We analysed the expression of circulating miRNAs in blood samples of 56 patients collected at admission and after revascularization (at 3, 6, 12 and 24 h). The associations between miRNAs and left ventricular end diastolic volumes at 6 months were estimated to detect LVAR. miRNAs were also analysed in samples isolated from peripheral blood mononuclear cells (PBMCs) and human myocardium of failing hearts. Kinetic analysis of miRNAs showed a fast time-dependent increase in miR-133a, miR-133b, miR-193b, miR-499, and miR-320a in STEMI patients compared to controls. Moreover, the expression of miR-29a, miR-29b, miR-324, miR-208, miR-423, miR-522, and miR-545 was differentially expressed even before PPCI in STEMI. Furthermore, the increase in circulating miR-320a and the decrease in its expression in PBMCs were significantly associated with LVAR and correlated with the expression of miR-320a in human failing myocardium from ischaemic origin. In conclusion, we determined the time course expression of new circulating miRNAs in patients with STEMI treated with PPCI and we showed that miR-320a was positively associated with LVAR.
- 1 July 2017
- Published by Elsevier in Cardiocore
- Vol. 52 (3) , 89-90
Electrocardiografía clínica: un clásico de plena actualidad
- 1 July 2017
- Published by Elsevier in Cardiocore
- Vol. 52 (3) , 89-90
Electrocardiografía clínica: un clásico de plena actualidad
- 1 January 2017
- Published by Elsevier in Cardiocore
- Vol. 52 (1) , 1-2
Resolver el jeroglífico: una tarea del cardiólogo
- 1 January 2017
- Published by Elsevier in Cardiocore
- Vol. 52 (1) , 1-2
Resolver el jeroglífico: una tarea del cardiólogo