Maoyu Wei
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Maoyu Wei has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Jiangfan Yao
Key Laboratory of RF Circuits and systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China
3 shared publications - Jin Chen
Key Laboratory of RF Circuits and systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China
3 shared publications - Lingling Sun
Hangzhou Dianzi University
3 shared publications - Wentao Han
Key Laboratory of RF Circuits and systems, Ministry of Education, Hangzhou Dianzi University, Hangzhou 310018, China
3 shared publications - Xiwei Huang
Hangzhou Dianzi University
3 shared publications - Hyungkook Jeon
Research Laboratory of Electronics, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
2 shared publications
Latest Publications
- Open Access
Correction: Huang et al. Deep-Learning Based Label-Free Classification of Activated and Inactivated Neutrophils for Rapid Immune State Monitoring. Sensors 2021, 21, 512
The authors wish to make the following correction to their paper
Open AccessCorrection: Huang et al. Deep-Learning Based Label-Free Classification of Activated and Inactivated Neutrophils for Rapid Immune State Monitoring. Sensors 2021, 21, 512
The authors wish to make the following correction to their paper
- Open Access
High-Precision Lensless Microscope on a Chip Based on In-Line Holographic Imaging
The lensless on-chip microscope is an emerging technology in the recent decade that can realize the imaging and analysis of biological samples with a wide field-of-view without huge optical devices and any lenses. Because of its small size, low cost, and being easy to hold and operate, it can be used as an alternative tool for large microscopes in resource-poor or remote areas, which is of great significance for the diagnosis, treatment, and prevention of diseases. To improve the low-resolution characteristics of the existing lensless shadow imaging systems and to meet the high-resolution needs of point-of-care testing, here, we propose a high-precision on-chip microscope based on in-line holographic technology. We demonstrated the ability of the iterative phase recovery algorithm to recover sample information and evaluated it with image quality evaluation algorithms with or without reference. The results showed that the resolution of the holographic image after iterative phase recovery is 1.41 times that of traditional shadow imaging. Moreover, we used machine learning tools to identify and count the mixed samples of mouse ascites tumor cells and micro-particles that were iterative phase recovered. The results showed that the on-chip cell counter had high-precision counting characteristics as compared with manual counting of the microscope reference image. Therefore, the proposed high-precision lensless microscope on a chip based on in-line holographic imaging provides one promising solution for future point-of-care testing (POCT).
Open AccessHigh-Precision Lensless Microscope on a Chip Based on In-Line Holographic Imaging
The lensless on-chip microscope is an emerging technology in the recent decade that can realize the imaging and analysis of biological samples with a wide field-of-view without huge optical devices and any lenses. Because of its small size, low cost, and being easy to hold and operate, it can be used as an alternative tool for large microscopes in resource-poor or remote areas, which is of great significance for the diagnosis, treatment, and prevention of diseases. To improve the low-resolution characteristics of the existing lensless shadow imaging systems and to meet the high-resolution needs of point-of-care testing, here, we propose a high-precision on-chip microscope based on in-line holographic technology. We demonstrated the ability of the iterative phase recovery algorithm to recover sample information and evaluated it with image quality evaluation algorithms with or without reference. The results showed that the resolution of the holographic image after iterative phase recovery is 1.41 times that of traditional shadow imaging. Moreover, we used machine learning tools to identify and count the mixed samples of mouse ascites tumor cells and micro-particles that were iterative phase recovered. The results showed that the on-chip cell counter had high-precision counting characteristics as compared with manual counting of the microscope reference image. Therefore, the proposed high-precision lensless microscope on a chip based on in-line holographic imaging provides one promising solution for future point-of-care testing (POCT).
- Open Access
Deep-Learning Based Label-Free Classification of Activated and Inactivated Neutrophils for Rapid Immune State Monitoring
The differential count of white blood cells (WBCs) is one widely used approach to assess the status of a patient’s immune system. Currently, the main methods of differential WBC counting are manual counting and automatic instrument analysis with labeling preprocessing. But these two methods are complicated to operate and may interfere with the physiological states of cells. Therefore, we propose a deep learning-based method to perform label-free classification of three types of WBCs based on their morphologies to judge the activated or inactivated neutrophils. Over 90% accuracy was finally achieved by a pre-trained fine-tuning Resnet-50 network. This deep learning-based method for label-free WBC classification can tackle the problem of complex instrumental operation and interference of fluorescent labeling to the physiological states of the cells, which is promising for future point-of-care applications.
Open AccessDeep-Learning Based Label-Free Classification of Activated and Inactivated Neutrophils for Rapid Immune State Monitoring
The differential count of white blood cells (WBCs) is one widely used approach to assess the status of a patient’s immune system. Currently, the main methods of differential WBC counting are manual counting and automatic instrument analysis with labeling preprocessing. But these two methods are complicated to operate and may interfere with the physiological states of cells. Therefore, we propose a deep learning-based method to perform label-free classification of three types of WBCs based on their morphologies to judge the activated or inactivated neutrophils. Over 90% accuracy was finally achieved by a pre-trained fine-tuning Resnet-50 network. This deep learning-based method for label-free WBC classification can tackle the problem of complex instrumental operation and interference of fluorescent labeling to the physiological states of the cells, which is promising for future point-of-care applications.