Jean-Pierre Remenieras
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jean-Pierre Remenieras has a total of 77 co-authors. Here are the top co-authors by number of shared publications:
Denis Kouame
IRIT Laboratory, Université de Toulouse, CNRS, Toulouse, France
2 shared publications- Duong-Hung Pham
IRIT Lab, Université de Toulouse, and CNRS UMR 5505, 118 Route de Narbonne, Toulouse, 31400, Occitanie, France
2 shared publications Frédéric Patat
Service de radiologie CHRU de Tours Tours France
2 shared publications- Frédéric Patat
INSERM U930 Imagerie et Cerveau, Université François-Rabelais de Tours, Tours, France; INSERM CIC 1415, Université François-Rabelais de Tours, Tours, France
2 shared publications - Adrian Basarab
Université Claude Bernard Lyon 1, INSA Lyon, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon, France
1 shared publication Agris Slesers
1 shared publication
Latest Publications
- 21 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (5) , 636-645
Computational Super-Resolution for Ultrasound Localization Microscopy Through Solving an Inverse Problem
Ultrasound localization microscopy (ULM) represents a significant advancement over traditional ultrasound (US) imaging, enabling super-resolution (SR) imaging of microvascular structures with unprecedented detail, by using microbubbles (MBs) as highly reflective contrast agents. After injection into the bloodstream, MBs are localized in US images to reconstruct the microvasculature. However, this technique faces a trade-off between MB localization accuracy and acquisition time. Perfusion with low MB concentrations reduces signal overlap and achieves high localization accuracy but requires extended acquisition times. Conversely, higher MB concentrations shorten acquisition times but increase signal overlap, limiting localization precision. Traditionally, ULM consists of five main steps: tissue filtering, MB detection, MB super-localization, tracking, and rendering. In this study, we present a novel approach that combines a robust principal component analysis (RPCA) with a computational SR technique, replacing the first three steps of ULM with a single process based on solving a SR inverse problem. This method isolates MB signals from background noise and enhances the localization of overlapping MBs, thereby improving overall ULM performance. Experimental results from simulated and in vivo data demonstrate that our proposed approach increases the SR factor by up to 30% and enhances the contrast ratio (CR) by 3.5 dB. It also produces comparable results across other image quality metrics. These improvements enable denser, higher-contrast vascular images.
- 21 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 72 (5) , 636-645
Computational Super-Resolution for Ultrasound Localization Microscopy Through Solving an Inverse Problem
Ultrasound localization microscopy (ULM) represents a significant advancement over traditional ultrasound (US) imaging, enabling super-resolution (SR) imaging of microvascular structures with unprecedented detail, by using microbubbles (MBs) as highly reflective contrast agents. After injection into the bloodstream, MBs are localized in US images to reconstruct the microvasculature. However, this technique faces a trade-off between MB localization accuracy and acquisition time. Perfusion with low MB concentrations reduces signal overlap and achieves high localization accuracy but requires extended acquisition times. Conversely, higher MB concentrations shorten acquisition times but increase signal overlap, limiting localization precision. Traditionally, ULM consists of five main steps: tissue filtering, MB detection, MB super-localization, tracking, and rendering. In this study, we present a novel approach that combines a robust principal component analysis (RPCA) with a computational SR technique, replacing the first three steps of ULM with a single process based on solving a SR inverse problem. This method isolates MB signals from background noise and enhances the localization of overlapping MBs, thereby improving overall ULM performance. Experimental results from simulated and in vivo data demonstrate that our proposed approach increases the SR factor by up to 30% and enhances the contrast ratio (CR) by 3.5 dB. It also produces comparable results across other image quality metrics. These improvements enable denser, higher-contrast vascular images.
- 18 April 2023
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 43 (9) , 1557-1570
Multi-layered adaptive neoangiogenesis Intra-Operative quantification (MANIOQ)
Quantification of vascularization volume can provide valuable information for diagnosis and prognosis in vascular pathologies. It can be adapted to inform the surgical management of gliomas, aggressive brain tumors characterized by exuberant sprouting of new blood vessels (neoangiogenesis). Filtered ultrafast Doppler data can provide two main parameters: vascularization index (VI) and fractional moving blood volume (FMBV) that clinically reflect tumor micro vascularization. Current protocols lack robust, automatic, and repeatable filtering methods. We present a filtrating method called Multi-layered Adaptive Neoangiogenesis Intra-Operative Quantification (MANIOQ). First, an adaptive clutter filtering is implemented, based on singular value decomposition (SVD) and hierarchical clustering. Second a method for noise equalization is applied, based on the subtraction of a weighted noise profile. Finally, an in vivo analysis of the periphery of the B-mode hyper signal area allows to measure the vascular infiltration extent of the brain tumors. Ninety ultrasound acquisitions were processed from 23 patients. Compared to reference methods in the literature, MANIOQ provides a more robust tissue filtering, and noise equalization allows for the first time to keep axial and lateral gain compensation (TGC and LGC). MANIOQ opens the way to an intra-operative clinical analysis of gliomas micro vascularization.
- 18 April 2023
- Published by SAGE Publications in Journal of Cerebral Blood Flow & Metabolism
- Vol. 43 (9) , 1557-1570
Multi-layered adaptive neoangiogenesis Intra-Operative quantification (MANIOQ)
Quantification of vascularization volume can provide valuable information for diagnosis and prognosis in vascular pathologies. It can be adapted to inform the surgical management of gliomas, aggressive brain tumors characterized by exuberant sprouting of new blood vessels (neoangiogenesis). Filtered ultrafast Doppler data can provide two main parameters: vascularization index (VI) and fractional moving blood volume (FMBV) that clinically reflect tumor micro vascularization. Current protocols lack robust, automatic, and repeatable filtering methods. We present a filtrating method called Multi-layered Adaptive Neoangiogenesis Intra-Operative Quantification (MANIOQ). First, an adaptive clutter filtering is implemented, based on singular value decomposition (SVD) and hierarchical clustering. Second a method for noise equalization is applied, based on the subtraction of a weighted noise profile. Finally, an in vivo analysis of the periphery of the B-mode hyper signal area allows to measure the vascular infiltration extent of the brain tumors. Ninety ultrasound acquisitions were processed from 23 patients. Compared to reference methods in the literature, MANIOQ provides a more robust tissue filtering, and noise equalization allows for the first time to keep axial and lateral gain compensation (TGC and LGC). MANIOQ opens the way to an intra-operative clinical analysis of gliomas micro vascularization.
- Open Access
- 11 February 2022
- Published by Wiley in Medical Physics
- Vol. 49 (3) , 1507-1521
Vibration‐controlled transient elastography for noninvasive evaluation of liver steatosis
Background: Nonalcoholic fatty liver disease (NAFLD) refers to a large spectrum of liver disorders and is the most common cause of metabolic liver disease. The current gold standard for diagnosing NAFLD is liver biopsy, which can lead to severe complications.Purpose: Among the noninvasive diagnostic options, we chose to use a FibroScan and developed an algorithm applying the Voigt rheological model to assess the viscoelastic properties of the liver and evaluate its performance for the diagnosis of steatosis.Methods: Twenty‐two healthy volunteers and 20 patients with steatosis were included. For each subject, we used a modified FibroScan, whose data had been processed by our algorithm to separate the two viscoelastic components, stiffness μ, and viscosity η. The liver elasticity μFibroscan measured by the FibroScan was also recorded. Mann–Whitney tests and receiver operating characteristics (ROCs) curve analyses were performed to compare the parameters between the two groups, and Pearson's correlation coefficients were used to assess the correlations between the parameters.Results: We found a good correlation between η and μFibroscan (r = 0.75), and poor correlations between μ and both η and μFibroscan (r = 0.33 and r = 0.03, respectively). We also showed that η and μFibroscan were higher in patients with steatosis compared to healthy volunteers, with area under the ROCs (AUROC) curve at 0.814 and 0.891, respectively. Conversely, μ was not different between the two groups (AUROC = 0.557).Conclusions: Our novel method successfully separated the two viscoelastic properties of the liver, of which the parameter η is a sensitive indicator for steatosis.
- 11 February 2022
- Published by Wiley in Medical Physics
- Vol. 49 (3) , 1507-1521
Open AccessVibration‐controlled transient elastography for noninvasive evaluation of liver steatosis
Background: Nonalcoholic fatty liver disease (NAFLD) refers to a large spectrum of liver disorders and is the most common cause of metabolic liver disease. The current gold standard for diagnosing NAFLD is liver biopsy, which can lead to severe complications.Purpose: Among the noninvasive diagnostic options, we chose to use a FibroScan and developed an algorithm applying the Voigt rheological model to assess the viscoelastic properties of the liver and evaluate its performance for the diagnosis of steatosis.Methods: Twenty‐two healthy volunteers and 20 patients with steatosis were included. For each subject, we used a modified FibroScan, whose data had been processed by our algorithm to separate the two viscoelastic components, stiffness μ, and viscosity η. The liver elasticity μFibroscan measured by the FibroScan was also recorded. Mann–Whitney tests and receiver operating characteristics (ROCs) curve analyses were performed to compare the parameters between the two groups, and Pearson's correlation coefficients were used to assess the correlations between the parameters.Results: We found a good correlation between η and μFibroscan (r = 0.75), and poor correlations between μ and both η and μFibroscan (r = 0.33 and r = 0.03, respectively). We also showed that η and μFibroscan were higher in patients with steatosis compared to healthy volunteers, with area under the ROCs (AUROC) curve at 0.814 and 0.891, respectively. Conversely, μ was not different between the two groups (AUROC = 0.557).Conclusions: Our novel method successfully separated the two viscoelastic properties of the liver, of which the parameter η is a sensitive indicator for steatosis.
- 13 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (14) , 145009
Acousto-elasticity of transversely isotropic incompressible soft tissues: characterization of skeletal striated muscle
Using shear wave elastography, we measure the changes in the wave speed with the stress produced by a striated muscle during isometric voluntary contraction. To isolate the behaviour of an individual muscle from complementary or antagonistic actions of adjacent muscles, we select the flexor digiti minimi muscle, whose sole function is to extend the little finger. To link the wave speed to the stiffness, we develop an acousto-elastic theory for shear waves in homogeneous, transversely isotropic, incompressible solids subject to an uniaxial stress. We then provide measurements of the apparent shear elastic modulus along, and transversely to, the fibre axis for six healthy human volunteers of different age and sex. The results display a great variety across the six subjects. We find that the slope of the apparent shear elastic modulus along the fibre direction changes inversely to the maximum voluntary contraction (MVC) produced by the volunteer. We propose an interpretation of our results by introducing the S (slow) or F (fast) nature of the fibres, which harden the muscle differently and accordingly, produce different MVCs. A natural follow-up on this study is to apply the method to patients with musculoskeletal disorders or neurodegenerative diseases.
- 13 July 2021
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 66 (14) , 145009
Acousto-elasticity of transversely isotropic incompressible soft tissues: characterization of skeletal striated muscle
Using shear wave elastography, we measure the changes in the wave speed with the stress produced by a striated muscle during isometric voluntary contraction. To isolate the behaviour of an individual muscle from complementary or antagonistic actions of adjacent muscles, we select the flexor digiti minimi muscle, whose sole function is to extend the little finger. To link the wave speed to the stiffness, we develop an acousto-elastic theory for shear waves in homogeneous, transversely isotropic, incompressible solids subject to an uniaxial stress. We then provide measurements of the apparent shear elastic modulus along, and transversely to, the fibre axis for six healthy human volunteers of different age and sex. The results display a great variety across the six subjects. We find that the slope of the apparent shear elastic modulus along the fibre direction changes inversely to the maximum voluntary contraction (MVC) produced by the volunteer. We propose an interpretation of our results by introducing the S (slow) or F (fast) nature of the fibres, which harden the muscle differently and accordingly, produce different MVCs. A natural follow-up on this study is to apply the method to patients with musculoskeletal disorders or neurodegenerative diseases.
- 11 January 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (2) , 023702
Natural shear wave imaging using vocal tract vibrations: Introducing vocal passive elastography (V-PE) to thyroid elasticity mapping
We present a shear wave elastography (SWE) approach for thyroid characterization that is inspired by passive elastography, which extracts elasticity from the natural vibrations in living tissues that are caused by cardiac motion, blood pulsatility, and muscle activity. On thyroid, this physiological noise is mainly due to the carotid pulsation, which is in the 1–10 Hz bandwidth and is located right next to the gland. In order to decrease the shear wavelength and increase the signal to noise ratio, we propose to create in the thyroid a complex shear wave field by using natural vocal tract vibrations. The nature of the sound can be easily modified to be narrow or broad band, with small or large amplitude. Using correlation-based algorithm and a sound sustained at 150 Hz, we have developed an innovative technique using ultrasound, allowing us to compute a 2D shear wave velocity map, superposed onto a B-mode ultrasound image of a volunteer's thyroid. Using our vocal passive elastography method, shear wave velocity was measured at every point within a mask surrounding the thyroid with a pixel resolution of 150 × 150 μm2. The mean shear wave speed value measured is 3.2 m/s, taking its value from 0.7 m/s to 8.8 m/s. The values obtained were in good agreement with comparative shear wave elastography (SWE) measurements.
- 11 January 2021
- Published by AIP Publishing in Applied Physics Letters
- Vol. 118 (2) , 023702
Natural shear wave imaging using vocal tract vibrations: Introducing vocal passive elastography (V-PE) to thyroid elasticity mapping
We present a shear wave elastography (SWE) approach for thyroid characterization that is inspired by passive elastography, which extracts elasticity from the natural vibrations in living tissues that are caused by cardiac motion, blood pulsatility, and muscle activity. On thyroid, this physiological noise is mainly due to the carotid pulsation, which is in the 1–10 Hz bandwidth and is located right next to the gland. In order to decrease the shear wavelength and increase the signal to noise ratio, we propose to create in the thyroid a complex shear wave field by using natural vocal tract vibrations. The nature of the sound can be easily modified to be narrow or broad band, with small or large amplitude. Using correlation-based algorithm and a sound sustained at 150 Hz, we have developed an innovative technique using ultrasound, allowing us to compute a 2D shear wave velocity map, superposed onto a B-mode ultrasound image of a volunteer's thyroid. Using our vocal passive elastography method, shear wave velocity was measured at every point within a mask surrounding the thyroid with a pixel resolution of 150 × 150 μm2. The mean shear wave speed value measured is 3.2 m/s, taking its value from 0.7 m/s to 8.8 m/s. The values obtained were in good agreement with comparative shear wave elastography (SWE) measurements.
- 30 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (4) , 969-978
Joint Blind Deconvolution and Robust Principal Component Analysis for Blood Flow Estimation in Medical Ultrasound Imaging
This article addresses the problem of high-resolution Doppler blood flow estimation from an ultrafast sequence of ultrasound images. Formulating the separation of clutter and blood components as an inverse problem has been shown in the literature to be a good alternative to spatio-temporal singular value decomposition (SVD)-based clutter filtering. In particular, a deconvolution step has recently been embedded in such a problem to mitigate the influence of the point spread function (PSF) of the imaging system. Deconvolution was shown in this context to improve the accuracy of the blood flow reconstruction. However, the PSF needs to be measured experimentally, and measuring it requires nontrivial experimental setups. To overcome this limitation, we propose herein a blind deconvolution method able to estimate both the blood component and the PSF from Doppler data. Numerical experiments conducted on simulated and in vivo data demonstrate qualitatively and quantitatively the effectiveness of the proposed approach in comparison with the previous method based on experimentally measured PSF and two other state-of-the-art approaches.
- 30 September 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 68 (4) , 969-978
Joint Blind Deconvolution and Robust Principal Component Analysis for Blood Flow Estimation in Medical Ultrasound Imaging
This article addresses the problem of high-resolution Doppler blood flow estimation from an ultrafast sequence of ultrasound images. Formulating the separation of clutter and blood components as an inverse problem has been shown in the literature to be a good alternative to spatio-temporal singular value decomposition (SVD)-based clutter filtering. In particular, a deconvolution step has recently been embedded in such a problem to mitigate the influence of the point spread function (PSF) of the imaging system. Deconvolution was shown in this context to improve the accuracy of the blood flow reconstruction. However, the PSF needs to be measured experimentally, and measuring it requires nontrivial experimental setups. To overcome this limitation, we propose herein a blind deconvolution method able to estimate both the blood component and the PSF from Doppler data. Numerical experiments conducted on simulated and in vivo data demonstrate qualitatively and quantitatively the effectiveness of the proposed approach in comparison with the previous method based on experimentally measured PSF and two other state-of-the-art approaches.
- 15 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (1) , 161-172
Methodology for developing a high-precision ultrasound flow meter and fluid velocity profile reconstruction
This article reports the methodology used to develop a high-precision ultrasound transit time flow meter dedicated to liquid hydrocarbons. This kind of flow meter is designed for custody transfer applications requiring accuracy better than 0.15% of reading. We focus here on certain specific points to achieve this accuracy. The transit time method needs to estimate accurately the time delay between signals received by a pair of transducers. In this study, we review different ways of estimating this time delay. We also propose a specific configuration of the flow meter paths. In particular, this configuration compensates for the swirl phenomenon, which has a significant impact on the accuracy of the flow meter. We also propose a theoretical parametric profile to reconstruct the fluid velocity profile in order to perform in situ diagnosis of the flow. The parameters of the model are estimated from the measurements of the flow meter. Simulations and experimental results showed that this method provides characterization of the flow in disturbed and undisturbed flow conditions.
- 15 February 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 55 (1) , 161-172
Methodology for developing a high-precision ultrasound flow meter and fluid velocity profile reconstruction
This article reports the methodology used to develop a high-precision ultrasound transit time flow meter dedicated to liquid hydrocarbons. This kind of flow meter is designed for custody transfer applications requiring accuracy better than 0.15% of reading. We focus here on certain specific points to achieve this accuracy. The transit time method needs to estimate accurately the time delay between signals received by a pair of transducers. In this study, we review different ways of estimating this time delay. We also propose a specific configuration of the flow meter paths. In particular, this configuration compensates for the swirl phenomenon, which has a significant impact on the accuracy of the flow meter. We also propose a theoretical parametric profile to reconstruct the fluid velocity profile in order to perform in situ diagnosis of the flow. The parameters of the model are estimated from the measurements of the flow meter. Simulations and experimental results showed that this method provides characterization of the flow in disturbed and undisturbed flow conditions.
- 25 October 2001
- Published by Cambridge University Press (CUP)
Cerebrovascular Ultrasound
Ultrasound provides a unique diagnostic perspective in cerebrovascular disorders, with extremely high temporal resolution and excellent spatial display of extracranial arteries, brain structures and cerebral vessels. This comprehensive text covers the fundamentals of ultrasound physics, new technology, and clinical applications in all ages. It provides a firm grounding in hemodynamics and describes computational models for study of the cerebral circulation. Extracranial applications in assessing the carotid and vertebral arteries are discussed in detail, as are intracranial Doppler applications in stroke, subarachnoid hemorrhage, arteriovenous malformations, interventional and surgical procedures, and the detection and monitoring of cerebral microembolism. These and other topics, both clinical and technical, are presented by leading authorities in the field, with extensive illustrations, and tables are included for the standardized classification of cerebrovascular diseases based on international consensus conferences. For clinicians and clinical neuroscientists this is the definitive reference text in cerebrovascular ultrasound.
- 25 October 2001
- Published by Cambridge University Press (CUP)
Cerebrovascular Ultrasound
Ultrasound provides a unique diagnostic perspective in cerebrovascular disorders, with extremely high temporal resolution and excellent spatial display of extracranial arteries, brain structures and cerebral vessels. This comprehensive text covers the fundamentals of ultrasound physics, new technology, and clinical applications in all ages. It provides a firm grounding in hemodynamics and describes computational models for study of the cerebral circulation. Extracranial applications in assessing the carotid and vertebral arteries are discussed in detail, as are intracranial Doppler applications in stroke, subarachnoid hemorrhage, arteriovenous malformations, interventional and surgical procedures, and the detection and monitoring of cerebral microembolism. These and other topics, both clinical and technical, are presented by leading authorities in the field, with extensive illustrations, and tables are included for the standardized classification of cerebrovascular diseases based on international consensus conferences. For clinicians and clinical neuroscientists this is the definitive reference text in cerebrovascular ultrasound.