Baiqiang Yin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Baiqiang Yin has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Lei Zuo
Hefei University of Technology
9 shared publications - Bing Li
Hefei University of Technology
8 shared publications - Lifen Yuan
Hefei University of Technology
8 shared publications - Yigang He
The State Key Laboratory of Power Grid Environmental Protection, School of Electrical Engineering and Automation, Wuhan University, Wuhan, China
8 shared publications - Zhen Cheng
Hefei University of Technology
6 shared publications - Chengwei Ding
Hefei University of Technology
5 shared publications
Latest Publications
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (19) , 28830-28840
An Analytical Performance Model for Linear UHF RFID Tag Arrays Under Mutual Coupling
- 1 October 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (19) , 28830-28840
An Analytical Performance Model for Linear UHF RFID Tag Arrays Under Mutual Coupling
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 861-871
Crosstalk Suppression Method at the End of Multiconductor Transmission Lines Based on Crosstalk Factor Theory
Considering the complexity and difficulty of solving the size of crosstalk capability of different transmission lines to each other in the signal transmission process of multi-conductor transmission lines, this paper proposes a new experimental method to determine the crosstalk capability of each transmission line to the other transmission lines on the basis of the theory of multi-conductor transmission lines, and names this crosstalk capability as crosstalk factor as the theoretical support for the selection of the optimal phase combination of excitation source signals of each transmission line to realize a better crosstalk suppression effect on the target transmission line. To realize better crosstalk suppression effect on the target transmission line. Through the comprehensive theoretical analysis of the influence factors of crosstalk factor, two five-wire transmission line structures, namely, parallel symmetric arrangement and bundled random arrangement, are selected for experimental verification. The study shows that the crosstalk factor can accurately express the difference in crosstalk capability between transmission lines at different frequencies. And at the target frequency, the crosstalk suppression effect on the target wire harness can reach more than 90 %, and the bundled random layout transmission line has a higher and more stable crosstalk suppression effect compared with the parallel symmetric layout transmission line.
- 24 February 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Components, Packaging and Manufacturing Technology
- Vol. 16 (4) , 861-871
Crosstalk Suppression Method at the End of Multiconductor Transmission Lines Based on Crosstalk Factor Theory
Considering the complexity and difficulty of solving the size of crosstalk capability of different transmission lines to each other in the signal transmission process of multi-conductor transmission lines, this paper proposes a new experimental method to determine the crosstalk capability of each transmission line to the other transmission lines on the basis of the theory of multi-conductor transmission lines, and names this crosstalk capability as crosstalk factor as the theoretical support for the selection of the optimal phase combination of excitation source signals of each transmission line to realize a better crosstalk suppression effect on the target transmission line. To realize better crosstalk suppression effect on the target transmission line. Through the comprehensive theoretical analysis of the influence factors of crosstalk factor, two five-wire transmission line structures, namely, parallel symmetric arrangement and bundled random arrangement, are selected for experimental verification. The study shows that the crosstalk factor can accurately express the difference in crosstalk capability between transmission lines at different frequencies. And at the target frequency, the crosstalk suppression effect on the target wire harness can reach more than 90 %, and the bundled random layout transmission line has a higher and more stable crosstalk suppression effect compared with the parallel symmetric layout transmission line.
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 3521513
High-Impedance Grounding Fault Detection Method for Distribution Networks Based on a Knowledge Distillation Optimized Lightweight Learning Model
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75, 3521513
High-Impedance Grounding Fault Detection Method for Distribution Networks Based on a Knowledge Distillation Optimized Lightweight Learning Model
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (14) , 1
Switchgear Fault Diagnosis Method Based on RFID Sensor Tag and DBN-WOA-ELM
- 1 January 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 26 (14) , 1
Switchgear Fault Diagnosis Method Based on RFID Sensor Tag and DBN-WOA-ELM
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 758-767
Study on the Influence of Liquid Level Height in Containers on RFID System Performance
Focusing on the issue of how variations in liquid level height within a container affect the performance of passive ultrahigh frequency (UHF) radio frequency identification (RFID) tags, this study derives a link budget model for a passive UHF RFID system based on RFID operational principles and electromagnetic wave propagation theory. Using power transmission coefficients, the study analyzes how impedance mismatch caused by liquid in the container affects system performance. To validate the theoretical model, a combination of simulations and indoor experiments was employed, establishing segmented models of the tag response signal power (RSSI) as a function of liquid level height in both vertical and horizontal tag orientations. The RSSI of two tags, Alien9662 and Alien9640, was tested in an open indoor environment across varying liquid levels from 0 mm to 140 mm, measuring signal strength variations under different liquid levels. Theoretical analysis and experimental results reveal that when the liquid level changes along the antenna’s bent arm, RSSI decreases significantly (e.g., from -43.4 dBm to -75.6 dBm for the Alien9662 tag in vertical deployment). when the liquid level changes along the small electrical loop, RSSI first increases and then decreases (e.g., from -52.8 dBm to -43.4 dBm for L < 20 mm), exhibiting a nonlinear variation with liquid level height. The RSSI changes observed in both tags align with the segmented models, validating the models accuracy. These findings not only provide a theoretical basis for understanding the impact of liquid environments on RFID system performance but also offer a reference for optimizing RFID tag placement in liquid containers, which could support practical applications such as inventory management and liquid level monitoring.
- 3 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Radio Frequency Identification
- Vol. 9, 758-767
Study on the Influence of Liquid Level Height in Containers on RFID System Performance
Focusing on the issue of how variations in liquid level height within a container affect the performance of passive ultrahigh frequency (UHF) radio frequency identification (RFID) tags, this study derives a link budget model for a passive UHF RFID system based on RFID operational principles and electromagnetic wave propagation theory. Using power transmission coefficients, the study analyzes how impedance mismatch caused by liquid in the container affects system performance. To validate the theoretical model, a combination of simulations and indoor experiments was employed, establishing segmented models of the tag response signal power (RSSI) as a function of liquid level height in both vertical and horizontal tag orientations. The RSSI of two tags, Alien9662 and Alien9640, was tested in an open indoor environment across varying liquid levels from 0 mm to 140 mm, measuring signal strength variations under different liquid levels. Theoretical analysis and experimental results reveal that when the liquid level changes along the antenna’s bent arm, RSSI decreases significantly (e.g., from -43.4 dBm to -75.6 dBm for the Alien9662 tag in vertical deployment). when the liquid level changes along the small electrical loop, RSSI first increases and then decreases (e.g., from -52.8 dBm to -43.4 dBm for L < 20 mm), exhibiting a nonlinear variation with liquid level height. The RSSI changes observed in both tags align with the segmented models, validating the models accuracy. These findings not only provide a theoretical basis for understanding the impact of liquid environments on RFID system performance but also offer a reference for optimizing RFID tag placement in liquid containers, which could support practical applications such as inventory management and liquid level monitoring.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Passive Ammonia Detection Sensor Based on Zinc Stannate Loaded Dual-Frequency Chipless RFID-Inspired Technique
Ammonia is a toxic and flammable gas, and chemical resistance sensors have great potential in practical ammonia monitoring applications. For scenarios where there is a lack of circuit wired connection, it is important to explore a passive wireless, low-cost, and universal means of detecting ammonia. However, due to the limitations of single-frequency operation and interference from environmental factors (e.g., temperature, humidity, interfere gas), research in this area is still ongoing. In this paper, a dual-band patch antenna-based passive ammonia sensor utilizing Chipless radio frequency identification (RFID)-inspired technology was designed. Meanwhile, the antenna’s performance parameters, including return loss, voltage standing wave ratio (VSWR), and normalized impedance, were optimized. Porous zinc stannate (Zn2SnO4) was selected as the sensing material, Zn2SnO4 material was characterized using Energy Dispersive Spectroscopy (EDS), Scanning Electron Microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The cross-shaped recess in the center of the antenna was coated with Zn2SnO4 to create the sensing unit. The passive sensor was operated at two distinct frequency bands, centered around 2.3 GHz and 4.5 GHz and exhibited advantageous characteristics such as a simple structure, mechanical flexibility, and high gain. The sensor demonstrated excellent stability and sensitivity at daily operating temperatures (25 °C). The limit of detection (LOD) method reveals that the detectable ammonia concentration is 40 ppm at the low-frequency point and 30 ppm at the high-frequency point. The reaction process between surface adsorbed oxygen species and ammonia is described to verify the passive sensing mechanism. This work presented Chipless RFID-inspired technology with a specific emphasis on passive ammonia detection, offering potential applications in environmental monitoring and industrial safety.
- 15 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Passive Ammonia Detection Sensor Based on Zinc Stannate Loaded Dual-Frequency Chipless RFID-Inspired Technique
Ammonia is a toxic and flammable gas, and chemical resistance sensors have great potential in practical ammonia monitoring applications. For scenarios where there is a lack of circuit wired connection, it is important to explore a passive wireless, low-cost, and universal means of detecting ammonia. However, due to the limitations of single-frequency operation and interference from environmental factors (e.g., temperature, humidity, interfere gas), research in this area is still ongoing. In this paper, a dual-band patch antenna-based passive ammonia sensor utilizing Chipless radio frequency identification (RFID)-inspired technology was designed. Meanwhile, the antenna’s performance parameters, including return loss, voltage standing wave ratio (VSWR), and normalized impedance, were optimized. Porous zinc stannate (Zn2SnO4) was selected as the sensing material, Zn2SnO4 material was characterized using Energy Dispersive Spectroscopy (EDS), Scanning Electron Microscopy (SEM) and X-ray photoelectron spectroscopy (XPS). The cross-shaped recess in the center of the antenna was coated with Zn2SnO4 to create the sensing unit. The passive sensor was operated at two distinct frequency bands, centered around 2.3 GHz and 4.5 GHz and exhibited advantageous characteristics such as a simple structure, mechanical flexibility, and high gain. The sensor demonstrated excellent stability and sensitivity at daily operating temperatures (25 °C). The limit of detection (LOD) method reveals that the detectable ammonia concentration is 40 ppm at the low-frequency point and 30 ppm at the high-frequency point. The reaction process between surface adsorbed oxygen species and ammonia is described to verify the passive sensing mechanism. This work presented Chipless RFID-inspired technology with a specific emphasis on passive ammonia detection, offering potential applications in environmental monitoring and industrial safety.
- 7 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Improved Singular Value Decomposition for Faulty Feeder Detection in Resonant Grounding Distribution System
In a resonant grounding distribution system (RGDS), the transient zero-sequence current component generated by single-phase-to-ground fault (SPGF) has unique modal characteristics, which is affected by fault initial angles. However, the complex working environment of distribution system complicates the extraction of transient components, especially under high noise levels. Singular value decomposition (SVD) is an effective technique to separate signal components from noise, while the effective singular values are the primary determinant of the separation accuracy. To improve the effective signal separation accuracy, a faulty feeder detection method based on improved SVD is proposed. By analyzing the transient features of zero-sequence current under different fault initial angles, an efficient singular value feature extraction method focusing on proper singular value order selection is developed. Furthermore, the similarity feature of the exponential decay sinusoidal components of zero-sequence current is integrated to achieve faulty feeder detection. Simulation and field tests validate the effectiveness of the proposed method under different fault initial angles. When the signal-to-noise ratio (SNR) exceeds 5 dB, the feeder detection accuracy exceeds 92.5%, which is 47% higher than that of traditional method. Moreover, the proposed method shows excellent robustness under high noise levels.
- 7 July 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-11
Improved Singular Value Decomposition for Faulty Feeder Detection in Resonant Grounding Distribution System
In a resonant grounding distribution system (RGDS), the transient zero-sequence current component generated by single-phase-to-ground fault (SPGF) has unique modal characteristics, which is affected by fault initial angles. However, the complex working environment of distribution system complicates the extraction of transient components, especially under high noise levels. Singular value decomposition (SVD) is an effective technique to separate signal components from noise, while the effective singular values are the primary determinant of the separation accuracy. To improve the effective signal separation accuracy, a faulty feeder detection method based on improved SVD is proposed. By analyzing the transient features of zero-sequence current under different fault initial angles, an efficient singular value feature extraction method focusing on proper singular value order selection is developed. Furthermore, the similarity feature of the exponential decay sinusoidal components of zero-sequence current is integrated to achieve faulty feeder detection. Simulation and field tests validate the effectiveness of the proposed method under different fault initial angles. When the signal-to-noise ratio (SNR) exceeds 5 dB, the feeder detection accuracy exceeds 92.5%, which is 47% higher than that of traditional method. Moreover, the proposed method shows excellent robustness under high noise levels.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Small-Sample GIS Partial Discharge Type Identification Method Based on Fusion of One-Dimensional AT-DRSN and IDRN Models
Different types of partial discharges (PD) in gas insulated switchgear (GIS) cause different degrees of GIS insulation damage, and correct PD identification is critical to GIS insulation status. This paper proposes a multi-model fusion PD pattern recognition method based on one-dimensional adaptive transfer deep residual shrinkage network (AT-DRSN) and improved deep residual network (IDRN), which fully utilizes PD time-domain waveform images generated from field inspection. Firstly, the finite-difference time-domain (FDTD) method and mathematical models are used to simulate GIS partial discharges, and the time-domain waveform image datasets of four typical partial discharge defects are established. Secondly, the network model is built based on time-domain feature sequences and time-order feature parameters respectively, and effectively combined with transfer learning method, and finally, the AT-DRSN and IDRN models are weighted and fused for PD pattern recognition. The results show that the model proposed in this paper can effectively achieve high-precision diagnosis of small-sample GIS PDs, with a recognition accuracy of 98.3%, and the accuracy under strong noise is still greater than 95%, which has higher accuracy and anti-interference performance compared with other methods, and is of reference value for small-sample PD recognition in the field.
- 6 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. PP (10709878) , 1
Small-Sample GIS Partial Discharge Type Identification Method Based on Fusion of One-Dimensional AT-DRSN and IDRN Models
Different types of partial discharges (PD) in gas insulated switchgear (GIS) cause different degrees of GIS insulation damage, and correct PD identification is critical to GIS insulation status. This paper proposes a multi-model fusion PD pattern recognition method based on one-dimensional adaptive transfer deep residual shrinkage network (AT-DRSN) and improved deep residual network (IDRN), which fully utilizes PD time-domain waveform images generated from field inspection. Firstly, the finite-difference time-domain (FDTD) method and mathematical models are used to simulate GIS partial discharges, and the time-domain waveform image datasets of four typical partial discharge defects are established. Secondly, the network model is built based on time-domain feature sequences and time-order feature parameters respectively, and effectively combined with transfer learning method, and finally, the AT-DRSN and IDRN models are weighted and fused for PD pattern recognition. The results show that the model proposed in this paper can effectively achieve high-precision diagnosis of small-sample GIS PDs, with a recognition accuracy of 98.3%, and the accuracy under strong noise is still greater than 95%, which has higher accuracy and anti-interference performance compared with other methods, and is of reference value for small-sample PD recognition in the field.