Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yang Song has a total of 19 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Influence of Copper Dose on Mycobacterium avium and Legionella pneumophila Growth in Premise Plumbing

    by Rania E. Smeltz, Fernando A. Roman Jr, Thomas Byrne, Rachel Finkelstein, Yang Song, Amy Pruden, Marc A. Edwards

    Effects of copper at 0, 4, 30, 250, or 2000 μg/L on microbial communities were examined over an 11 month dosing period using triplicate 120 mL water heater microcosms with PEX-b pipes containing mature biofilms to simulate premise plumbing. Effluent total cell counts (TCCs) and Mycobacterium avium peaked at 250 μg/L, reflecting the dual role of copper as a nutrient and antimicrobial. TCCs and M. avium were relatively consistent among replicate microcosms at each dose, but Legionella pneumophila (Lp) diverged among biological triplicates at 250 μg/L, consistently producing high culturable Lp (average 2.5 log MPN/mL) in one microcosm and low/nondetectable levels in the other two. Repeated cross-inoculations and a reinoculation failed to normalize the microbial community composition across 250 μg/L and other triplicate microcosms. 16S rRNA gene amplicon sequencing revealed that the 250 μg/L replicate with a high Lp was characterized by a distinct microbial community composition relative to the two replicates. At 2000 μg/L copper, microbial diversity and TCCs initially decreased, but then TCCs subsequently increased and ultimately were not statistically different from the 250 μg/L microcosms. This study provides insight into mechanisms underlying nonlinear effects of copper dosing when applied as a disinfectant to premise plumbing for opportunistic pathogen control.


  • Open Access

    Influence of Copper Dose on Mycobacterium avium and Legionella pneumophila Growth in Premise Plumbing

    by Rania E. Smeltz, Fernando Adali Roman, Thomas Byrne, Rachel Finkelstein, Yang Song, Amy Pruden, Marc A. Edwards

    Effects of copper at 0, 4, 30, 250, or 2000 µg/L on microbial communities were examined in an 11-month study using triplicate 120-mL water heater microcosms with PEX-b pipes containing mature biofilms to simulate premise plumbing. Effluent total cell counts (TCCs) and Mycobacterium avium peaked at 250 µg/L, reflecting the dual role of copper as a nutrient and antimicrobial. TCCs and M. avium were relatively consistent among replicate microcosms at each dose, but Legionella pneumophila (Lp) diverged among biological triplicates at 250 µg/L, consistently producing high culturable Lp (average 2.5 log MPN/mL) in one microcosm and low/non-detectable levels in the other two. Repeated cross-inoculations and a reinoculation failed to normalize the microbial community composition across 250 µg/L and other triplicate microcosms. 16S rRNA gene amplicon sequencing revealed that the 250 µg/L replicate with high Lp was characterized by a distinct microbial community composition relative to the two replicates. At 2,000 µg/L copper, microbial diversity and TCCs initially decreased, but then TCCs subsequently increased and ultimately were not statistically different from the 250 µg/L microcosms. This study provides insight into mechanisms underlying non-linear effects of copper dosing when applied as a disinfectant to premise plumbing for opportunistic pathogen control. SYNOPSIS: Non-linear effects of copper on Legionella pneumophila and microbial communities are identified, providing deeper understanding to the efficacy of its use as a premise plumbing disinfectant.


  • Open Access

    Effects of Copper on Legionella pneumophila Revealed via Viability Assays and Proteomics

    by Yang Song, Didier Mena-Aguilar, Connor L. Brown, William J. Rhoads, Richard F. Helm, Amy Pruden, Marc A. Edwards

    Cu is an antimicrobial that is commonly applied to premise (i.e., building) plumbing systems for Legionella control, but the precise mechanisms of inactivation are not well defined. Here, we applied a suite of viability assays and mass spectrometry-based proteomics to assess the mechanistic effects of Cu on L. pneumophila. Although a five- to six-log reduction in culturability was observed with 5 mg/L Cu2+ exposure, cell membrane integrity only indicated a Legionella relative to culturable cells. Other proteins related to cell membrane synthesis and motility were also higher for the Cu-exposed cells relative to controls without Cu. While the proteins related to primary metabolism decreased for the Cu-exposed cells, no significant differences in the abundance of proteins related to virulence or infectivity were found, which was consistent with the ability of VBNC cells to cause infections. Whereas the cell-membrane integrity assay provided an upper-bound measurement of viability, an amoebae co-culture assay provided a lower-bound limit. The findings have important implications for assessing Legionella risk following its exposure to copper in engineered water systems.


  • Open Access

    Shotgun Metagenomics Reveals Impacts of Copper and Water Heater Anodes on Pathogens and Microbiomes in Hot Water Plumbing Systems

    by Yang Song, Rachel Finkelstein, William Rhoads, Marc A. Edwards, Amy Pruden

    Hot water building plumbing systems are vulnerable to the proliferation of opportunistic pathogens (OPs), including Legionella pneumophila and Mycobacterium avium. Implementation of copper as a disinfectant could help reduce OPs, but a mechanistic understanding of the effects on the microbial community under real-world plumbing conditions is lacking. Here, we carried out a controlled pilot-scale study of hot water systems and applied shotgun metagenomic sequencing to examine the effects of copper dose (0-2 mg/L), orthophosphate corrosion control agent, and water heater anode materials (aluminum vs magnesium vs powered anode) on the bulk water and biofilm microbiome composition. Metagenomic analysis revealed that, even though a copper dose of 1.2 mg/L was required to reduce Legionella and Mycobacterium numbers, lower doses (e.g., ≤0.6 mg/L) measurably impacted the broader microbial community, indicating that the OP strains colonizing these systems were highly copper tolerant. Orthophosphate addition reduced bioavailability of copper, both to OPs and to the broader microbiome. Functional gene analysis indicated that both membrane damage and interruption of nucleic acid replication are likely at play in copper inactivation mechanisms. This study identifies key factors (e.g., orthophosphate, copper resistance, and anode materials) that can confound the efficacy of copper for controlling OPs in hot water plumbing.


  • Copper Pipe, Lack of Corrosion Control, and Very Low pH May Have Influenced the Trajectory of the Flint Legionnaires’ Disease Outbreak

    by Rebekah L. Martin, Owen Strom, Yang Song, Didier Mena-Aguilar, William J. Rhoads, Amy Pruden, Marc A. Edwards


  • Natural Organic Matter, Orthophosphate, pH, and Growth Phase Can Limit Copper Antimicrobial Efficacy for Legionella in Drinking Water

    by Yang Song, Amy Pruden, Marc A. Edwards, William J. Rhoads

    Copper (Cu) is a promising antimicrobial for premise plumbing, where ions can be dosed directly via copper silver ionization or released naturally via corrosion of Cu pipes, but Cu sometimes inhibits and other times stimulates Legionella growth. Our overarching hypothesis was that water chemistry and growth phase control the net effect of Cu on Legionella. The combined effects of pH, phosphate concentration, and natural organic matter (NOM) were comprehensively examined over a range of conditions relevant to drinking water in bench-scale pure culture experiments, illuminating the effects of Cu speciation and precipitation. It was found that cupric ions (Cu2+) were drastically reduced at pH > 7.0 or in the presence of ligand-forming phosphates or NOM. Further, exponential phase L. pneumophila were 2.5× more susceptible to Cu toxicity relative to early stationary phase cultures. While Cu2+ ion was the most effective biocidal form of Cu, other inorganic ligands also had some biocidal impacts. A comparison of 33 large drinking water utilities’ field-data from 1990 and 2018 showed that Cu2+ levels likely decreased more dramatically (>10×) than did the total or soluble Cu (2×) over recent decades. The overall findings aid in improving the efficacy of Cu as an actively dosed or passively released antimicrobial against L. pneumophila.


  • Open Access

    Critical Review: Propensity of Premise Plumbing Pipe Materials to Enhance or Diminish Growth of Legionella and Other Opportunistic Pathogens

    by Abraham C. Cullom, Rebekah L. Martin, Yang Song, Krista Williams, Amanda Williams, Amy Pruden, Marc A. Edwards

    Growth of Legionella pneumophila and other opportunistic pathogens (OPs) in drinking water premise plumbing poses an increasing public health concern. Premise plumbing is constructed of a variety of materials, creating complex environments that vary chemically, microbiologically, spatially, and temporally in a manner likely to influence survival and growth of OPs. Here we systematically review the literature to critically examine the varied effects of common metallic (copper, iron) and plastic (PVC, cross-linked polyethylene (PEX)) pipe materials on factors influencing OP growth in drinking water, including nutrient availability, disinfectant levels, and the composition of the broader microbiome. Plastic pipes can leach organic carbon, but demonstrate a lower disinfectant demand and fewer water chemistry interactions. Iron pipes may provide OPs with nutrients directly or indirectly, exhibiting a high disinfectant demand and potential to form scales with high surface areas suitable for biofilm colonization. While copper pipes are known for their antimicrobial properties, evidence of their efficacy for OP control is inconsistent. Under some circumstances, copper’s interactions with premise plumbing water chemistry and resident microbes can encourage growth of OPs. Plumbing design, configuration, and operation can be manipulated to control such interactions and health outcomes. Influences of pipe materials on OP physiology should also be considered, including the possibility of influencing virulence and antibiotic resistance. In conclusion, all known pipe materials have a potential to either stimulate or inhibit OP growth, depending on the circumstances. This review delineates some of these circumstances and informs future research and guidance towards effective deployment of pipe materials for control of OPs.