Baseem H. Al-Sabbagh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Baseem H. Al-Sabbagh has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ahmed Faiq Al-Alawy
Department of Chemical Engineering, College of Engineering, University of Baghdad, Baghdad, Iraq
2 shared publications - Nada Naoum Abdulrazzaq
Chemical Engineering Department, College of Engineering, University of Baghdad, Iraq
2 shared publications Abdulameer Almalichy
Faculty of Earth and Environmental Sciences and Engineering, Institute of Mining and Energy, University of Miskolc, H-3515, Miskolc-Egyetemvaros, Hungary
1 shared publication- Abeer Ibrahim Alwared
University of Baghdad
1 shared publication Ahmed F. Al-Alawy
Chemical Engineering Department, University of Baghdad, College of Engineering, Baghdad, Iraq
1 shared publication- Haider A. Shanshool1 shared publication
Latest Publications
- 10 October 2025
- Published by Springer Nature in Chemical Papers
- Vol. 80 (1) , 747-756
Performance evaluation of a small-scale laboratory pressure swing adsorption-based oxygen concentrator
- 10 October 2025
- Published by Springer Nature in Chemical Papers
- Vol. 80 (1) , 747-756
Performance evaluation of a small-scale laboratory pressure swing adsorption-based oxygen concentrator
- Open Access
- 30 September 2025
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 26 (3) , 11-17
A low-cost in-line ozone gas monitor via ultraviolet absorption spectroscopy
A low-cost in-line ozone monitor based on the principle of ultraviolet absorption was built and tested for different ozone for concentrations up to 300 mg h-1 and flow rates up to 5 lpm using air as a feed source. A widely available T5 ultraviolet (UV) tube was used as a UV source and two UV light absorption cells were made to act as reference and measuring cells. The output of the two cells was used to calculate the ozone concentration using Beer-Lambert’s law. To correlate the output readings of the ozone monitor with those obtained using the iodometric titration method, a correction factor of 1.5117 was determined and applied. The results demonstrate a strong linear correlation ≥0.99 between estimated and measured ozone concentration values. Relative errors less than 10% were observed for ozone concentrations ranging from 400 to 5000 ppb, while a relative error up to 16% was reported for concentrations below 400 ppb. The developed monitor offers a cost-effective alternative to expensive ozone monitoring systems for standard applications, with a total construction cost under $100.
- 30 September 2025
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 26 (3) , 11-17
Open AccessA low-cost in-line ozone gas monitor via ultraviolet absorption spectroscopy
A low-cost in-line ozone monitor based on the principle of ultraviolet absorption was built and tested for different ozone for concentrations up to 300 mg h-1 and flow rates up to 5 lpm using air as a feed source. A widely available T5 ultraviolet (UV) tube was used as a UV source and two UV light absorption cells were made to act as reference and measuring cells. The output of the two cells was used to calculate the ozone concentration using Beer-Lambert’s law. To correlate the output readings of the ozone monitor with those obtained using the iodometric titration method, a correction factor of 1.5117 was determined and applied. The results demonstrate a strong linear correlation ≥0.99 between estimated and measured ozone concentration values. Relative errors less than 10% were observed for ozone concentrations ranging from 400 to 5000 ppb, while a relative error up to 16% was reported for concentrations below 400 ppb. The developed monitor offers a cost-effective alternative to expensive ozone monitoring systems for standard applications, with a total construction cost under $100.
- Open Access
- 29 August 2025
- Published by Elsevier in Desalination and Water Treatment
- Vol. 323
Thiourea degradation in aqueous solutions via ozonation
- 29 August 2025
- Published by Elsevier in Desalination and Water Treatment
- Vol. 323
Open AccessThiourea degradation in aqueous solutions via ozonation
- 1 April 2021
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 40
Coupling of electrocoagulation and microflotation for the removal of textile dyes from aqueous solutions
- 1 April 2021
- Published by Elsevier in Journal of Water Process Engineering
- Vol. 40
Coupling of electrocoagulation and microflotation for the removal of textile dyes from aqueous solutions
- Open Access
- 30 June 2019
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 20 (2) , 1-9
Micro-Bubble Flotation for Removing Cadmium Ions from Aqueous Solution: Artificial Neural Network Modeling and Kinetic of Flotation
In this work, microbubble dispersed air flotation technique was applied for cadmium ions removal from wastewater aqueous solution. Experiments parameters such as pH (3, 4, 5, and 6), initial Cd(II) ions concentration (40, 80, and 120 mg/l) contact time( 2, 5, 10 , 15, and 20min), and surfactant (10, 20and 40mg/l) were studied in order to optimize the best conditions .The experimental results indicate that microbubbles were quite effective in removing cadmium ions and the anionic surfactant SDS was found to be more efficient than cationic CTAB in flotation process. 92.3% maximum removal efficiency achieved through 15min at pH 5, SDS surfactant concentration 20mg/l, flow rate250 cm3/min and at 40mg/l Cd(II) ions initial concentration. The removal efficiency of cadmium ion was predicted through 11 neurons hidden layer, with a correlation coefficient of 0.9997 between ANN outputs and the experimental data and through sensitivity analysis, pH was found to be most significant parameter (25.13 %).The kinetic flotation order for cadmium ions almost first order and the removal rate constant (k) increases with decreasing the initial metal concentration.
- 30 June 2019
- Published by Iraqi Journal of Chemical and Petroleum Engineering in Iraqi Journal of Chemical and Petroleum Engineering
- Vol. 20 (2) , 1-9
Open AccessMicro-Bubble Flotation for Removing Cadmium Ions from Aqueous Solution: Artificial Neural Network Modeling and Kinetic of Flotation
In this work, microbubble dispersed air flotation technique was applied for cadmium ions removal from wastewater aqueous solution. Experiments parameters such as pH (3, 4, 5, and 6), initial Cd(II) ions concentration (40, 80, and 120 mg/l) contact time( 2, 5, 10 , 15, and 20min), and surfactant (10, 20and 40mg/l) were studied in order to optimize the best conditions .The experimental results indicate that microbubbles were quite effective in removing cadmium ions and the anionic surfactant SDS was found to be more efficient than cationic CTAB in flotation process. 92.3% maximum removal efficiency achieved through 15min at pH 5, SDS surfactant concentration 20mg/l, flow rate250 cm3/min and at 40mg/l Cd(II) ions initial concentration. The removal efficiency of cadmium ion was predicted through 11 neurons hidden layer, with a correlation coefficient of 0.9997 between ANN outputs and the experimental data and through sensitivity analysis, pH was found to be most significant parameter (25.13 %).The kinetic flotation order for cadmium ions almost first order and the removal rate constant (k) increases with decreasing the initial metal concentration.
- Open Access
- 3 August 2018
- Published by MDPI AG in Chemosensors
- Vol. 6 (3) , 31
Measuring Vapor and Liquid Concentrations for Binary and Ternary Systems in a Microbubble Distillation Unit via Gas Sensors
A cost effective, fast, and accurate technique was needed to measure the vapor composition of a binary system (ethanol-water) and also that of a liquid composition in a ternary system (acetic acid-acetol–water) in a microbubble distillation unit. Cheap TGS-series gas sensors were used for this purpose with both calibrations and measurements carried out in a specially designed chamber. A single parameter polynomial regression was fitted to the binary system, and a two parameter polynomial with an interaction term was fitted to the ternary system. The correlation coefficient, R-squared, was found to be greater than 0.99 for both systems, thus validating the implementation of this novel sensor.
- 3 August 2018
- Published by MDPI AG in Chemosensors
- Vol. 6 (3) , 31
Open AccessMeasuring Vapor and Liquid Concentrations for Binary and Ternary Systems in a Microbubble Distillation Unit via Gas Sensors
A cost effective, fast, and accurate technique was needed to measure the vapor composition of a binary system (ethanol-water) and also that of a liquid composition in a ternary system (acetic acid-acetol–water) in a microbubble distillation unit. Cheap TGS-series gas sensors were used for this purpose with both calibrations and measurements carried out in a specially designed chamber. A single parameter polynomial regression was fitted to the binary system, and a two parameter polynomial with an interaction term was fitted to the ternary system. The correlation coefficient, R-squared, was found to be greater than 0.99 for both systems, thus validating the implementation of this novel sensor.