Mohsen Rezasoltani
Research Subjects
Mohsen Rezasoltani has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Dale R. Tree
Department of Mechanical Engineering, Brigham Young University, 435M CTB, Provo, UT 84602
3 shared publications - Darrel Zeltner
Solar Turbine, 2200 Pacific Highway, San Diego, CA 92101
3 shared publications - Scott C. Egbert
Mechanical Engineering, Brigham Young University, Provo, UT 84602
2 shared publications Dustin Badger
Department of Mechanical Engineering, Brigham Young University, Provo, UT 84602
1 shared publication
Latest Publications
- 3 January 2022
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 144 (3)
Turbine Inlet Temperature Measurements in an 8200 KW Gas Turbine Using Water Vapor Emission
The measurement of turbine inlet temperature is challenging because of high temperatures and complicated physical access, but continuous measurement of the turbine inlet temperature is very important for maximizing turbine efficiency and increasing durability. This paper provides in situ turbine rotor inlet temperature measurements in an 8200 kW operating gas turbine engine. The measurements were obtained using integrated spectral infrared emission from the water vapor of the combustion gases entering the turbine rotor. The method utilizes a sapphire optical fiber to convey the signal from the turbine wall to outside the turbine casing. All components are capable of long-term exposure to the turbine operating conditions. The temperature measurements were obtained at 6 operating conditions between 50% and full load. The turbine rotor inlet temperature temperature was also determined using more than 20 test cell inputs and Solar Turbine's commercial test cell engine model. The two temperatures (measured and modeled) were within 11 K (less than 1%) across the load sweep. Uncertainty calculations suggest that the uncertainty of the measurement can be expected to be ±2.9% within a confidence interval of 95%. The method also yields the nozzle guide vane surface temperature, which was found to increase monotonically with increasing load.
- 3 January 2022
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 144 (3)
Turbine Inlet Temperature Measurements in an 8200 KW Gas Turbine Using Water Vapor Emission
The measurement of turbine inlet temperature is challenging because of high temperatures and complicated physical access, but continuous measurement of the turbine inlet temperature is very important for maximizing turbine efficiency and increasing durability. This paper provides in situ turbine rotor inlet temperature measurements in an 8200 kW operating gas turbine engine. The measurements were obtained using integrated spectral infrared emission from the water vapor of the combustion gases entering the turbine rotor. The method utilizes a sapphire optical fiber to convey the signal from the turbine wall to outside the turbine casing. All components are capable of long-term exposure to the turbine operating conditions. The temperature measurements were obtained at 6 operating conditions between 50% and full load. The turbine rotor inlet temperature temperature was also determined using more than 20 test cell inputs and Solar Turbine's commercial test cell engine model. The two temperatures (measured and modeled) were within 11 K (less than 1%) across the load sweep. Uncertainty calculations suggest that the uncertainty of the measurement can be expected to be ±2.9% within a confidence interval of 95%. The method also yields the nozzle guide vane surface temperature, which was found to increase monotonically with increasing load.
- Open Access
- 16 July 2021
- Published by ASME International
High Pressure Optical Measurements of Temperature at Turbine Rotor Inlet Conditions
The measurement of combustion product gas temperature is valuable for the development and control of many combustion systems. In gas turbines engines, measurement of the rotor inlet temperature remains particularly challenging because of harsh operating conditions and limited access. The integrated spectral band ratio (ISBR) method is a non-intrusive optical emission temperature
- 16 July 2021
- Published by ASME International
Open AccessHigh Pressure Optical Measurements of Temperature at Turbine Rotor Inlet Conditions
The measurement of combustion product gas temperature is valuable for the development and control of many combustion systems. In gas turbines engines, measurement of the rotor inlet temperature remains particularly challenging because of harsh operating conditions and limited access. The integrated spectral band ratio (ISBR) method is a non-intrusive optical emission temperature
- 11 March 2021
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 143 (5)
High-Pressure Optical Measurements of Temperature at Turbine Rotor Inlet Conditions
In gas turbine engines, the measurement of the rotor inlet temperature remains particularly challenging because of harsh operating conditions and limited access. The integrated spectral band ratio (ISBR) method is a nonintrusive optical emission gas temperature measurement technique suitable for this application. Optical fibers made of sapphire were used to transmit the radiative signal from the postcombustion zone to a Fourier transform infrared (FTIR) spectrometer. The ratio of spectral bands of H2O, nominally 100 cm−1 wide between 4600 and 6200 cm−1, was used to infer temperature. ISBR and thermocouple measurements were obtained during two temperature sweeps: one at high load and one at low load (pressures of 1.2 and 0.7 MPa, respectively). The average of three thermocouples 76 mm downstream of the ISBR measurements was on the order of 200 K lower than the ISBR temperatures, consistent with a radiative correction and the heat loss between the two measurements. The change in ISBR temperature (95 K) during the sweep was similar to the change in average thermocouple temperature (89 K). Repeatability of the optical measurement at a given operating condition was on the order of ±15 K and the absolute uncertainty of a single ISBR temperature measurement was estimated to be ±61 K. A linear correlation with an R2 value of 0.97 was also found between raw optical signal and thermocouple measurements, suggesting that once a calibrated measurement is obtained.
- 11 March 2021
- Published by ASME International in Journal of Engineering for Gas Turbines and Power
- Vol. 143 (5)
High-Pressure Optical Measurements of Temperature at Turbine Rotor Inlet Conditions
In gas turbine engines, the measurement of the rotor inlet temperature remains particularly challenging because of harsh operating conditions and limited access. The integrated spectral band ratio (ISBR) method is a nonintrusive optical emission gas temperature measurement technique suitable for this application. Optical fibers made of sapphire were used to transmit the radiative signal from the postcombustion zone to a Fourier transform infrared (FTIR) spectrometer. The ratio of spectral bands of H2O, nominally 100 cm−1 wide between 4600 and 6200 cm−1, was used to infer temperature. ISBR and thermocouple measurements were obtained during two temperature sweeps: one at high load and one at low load (pressures of 1.2 and 0.7 MPa, respectively). The average of three thermocouples 76 mm downstream of the ISBR measurements was on the order of 200 K lower than the ISBR temperatures, consistent with a radiative correction and the heat loss between the two measurements. The change in ISBR temperature (95 K) during the sweep was similar to the change in average thermocouple temperature (89 K). Repeatability of the optical measurement at a given operating condition was on the order of ±15 K and the absolute uncertainty of a single ISBR temperature measurement was estimated to be ±61 K. A linear correlation with an R2 value of 0.97 was also found between raw optical signal and thermocouple measurements, suggesting that once a calibrated measurement is obtained.