YPYunjae Park

Yunjae Park

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yunjae Park has a total of 7 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A New Measurement Method for High Voltages Applied to an Ion Trap Generated by an RF Resonator

    by Yunjae Park, Changhyun Jung, Myeongseok Seong, Minjae Lee, Dongil Dan Cho, Taehyun Kim

    A new method is proposed to measure unknown amplitudes of radio frequency (RF) voltages applied to ion traps, using a pre-calibrated voltage divider with RF shielding. In contrast to previous approaches that estimate the applied voltage by comparing the measured secular frequencies with a numerical simulation, we propose using a pre-calibrated voltage divider to determine the absolute amplitude of large RF voltages amplified by a helical resonator. The proposed method does not require measurement of secular frequencies and completely removes uncertainty caused by limitations of numerical simulations. To experimentally demonstrate our method, we first obtained a functional relation between measured secular frequencies and large amplitudes of RF voltages using the calibrated voltage divider. A comparison of measured relations and simulation results without any fitting parameters confirmed the validity of the proposed method. Our method can be applied to most ion trap experiments. In particular, it will be an essential tool for surface ion traps which are extremely vulnerable to unknown large RF voltages and for improving the accuracy of numerical simulations for ion trap experiments.


  • Open Access

    A Feedback Control Method to Maintain the Amplitude of the RF Signal Applied to Ion Traps

    by Yunjae Park, Hyunseok Oh, Seungwoo Yoo, Taehyun Kim, Dongil “Dan” Cho

    For high-fidelity quantum operations in ion traps, it is important to maintain the secular frequency of the trapped ions at a constant value. The radial secular frequency is proportional to the amplitude of the radio frequency (RF) signal applied to ion traps. Owing to the changes in the ambient temperature of a helical resonator and the minute vibration of the optical table, the amplitude can vary. Recently, a method for reducing the fluctuation in the RF signal amplitude, using a commercial universal proportional-plus-integral (PI) controller, has been introduced, which, in turn, reduces the secular frequency drift of the trapped ions. The method improves the capability to maintain the secular frequency at a constant value. However, the structure of the controller is fixed; thus, the control method cannot be changed to suit different experimental conditions, and the different feedback configuration cannot be implemented to increase the resolution. In this paper, we develop a field-programmable gate array (FPGA)-based feedback controller that allows the implementation of various automatic control methods and feedback configurations. In our experiments, the fluctuation in the amplitude of the RF signal was 1.806% using a commercial universal PI controller. The fluctuation was reduced to 0.099% using the developed FPGA-based PI controller, and to 0.102% using the developed FPGA-based lag compensator. By employing the developed FPGA control method, many other automating control methods can be applied to achieve a stable and high-performance control of the secular frequency.