Mohammad Hassan Ghaderi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mohammad Hassan Ghaderi has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Mohsen Hamzeh
School of Electrical and Computer Engineering College of Engineering University of Tehran Tehran Iran
3 shared publications - Babak Fahimi
Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX, USA
2 shared publications - Milad Bahrami-Fard
Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX, USA
2 shared publications - Mohammad Rastegar
Department of Electrical and Computer Engineering, University of Texas at Dallas, Richardson, TX, USA
2 shared publications - Poras T. Balsara
Department of Electrical and Computer Engineering, The University of Texas at Dallas, Richardson, TX, USA
2 shared publications - Ali Sarikhani
University of Tehran, 48425 Tehran, Tehran Iran (the Islamic Republic of)
1 shared publication
Latest Publications
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 8987-9001
A Comprehensive Methodology for Detecting Demagnetization and Initial Rotor Position in SM-PMSMs
Estimating the initial rotor position is critical for the proper startup, efficient torque production, and reliable operation of permanent magnet synchronous motors (PMSMs), as well as for preventing demagnetization. This article presents a comprehensive method for detecting the rotor position under standstill and flying shaft (i.e., no stator excitation) conditions in a surface-mounted PMSM (SM-PMSM). Initial rotor position detection in SM-PMSMs is challenging due to weak magnetic saliency, nonlinearities, and parameter variations. Even small inaccuracies can significantly affect motor efficiency, performance, and longevity, particularly in applications involving varying speeds or loads. In this article, a series of voltage pulses using basis space vectors are applied to the stator windings of a three-phase SM-PMSM. The positive and negative current values are evaluated, alongside the recorded differences between their absolute peak values. These differences, influenced by the permanent magnets, are leveraged to detect the rotor position without direct access to the rotor. A numerical model of a four-pole SM-PMSM is developed using Maxwell two-dimensional to validate the magnetic circuit changes. The proposed method's performance in early detection of demagnetization is also introduced and validated numerically and experimentally. Finally, the method's efficacy is experimentally assessed under standstill and flying shaft conditions, along with its impact on synchronous startup in sensorless control of SM-PMSMs and its effectiveness in early demagnetization detection.
- 19 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 41 (6) , 8987-9001
A Comprehensive Methodology for Detecting Demagnetization and Initial Rotor Position in SM-PMSMs
Estimating the initial rotor position is critical for the proper startup, efficient torque production, and reliable operation of permanent magnet synchronous motors (PMSMs), as well as for preventing demagnetization. This article presents a comprehensive method for detecting the rotor position under standstill and flying shaft (i.e., no stator excitation) conditions in a surface-mounted PMSM (SM-PMSM). Initial rotor position detection in SM-PMSMs is challenging due to weak magnetic saliency, nonlinearities, and parameter variations. Even small inaccuracies can significantly affect motor efficiency, performance, and longevity, particularly in applications involving varying speeds or loads. In this article, a series of voltage pulses using basis space vectors are applied to the stator windings of a three-phase SM-PMSM. The positive and negative current values are evaluated, alongside the recorded differences between their absolute peak values. These differences, influenced by the permanent magnets, are leveraged to detect the rotor position without direct access to the rotor. A numerical model of a four-pole SM-PMSM is developed using Maxwell two-dimensional to validate the magnetic circuit changes. The proposed method's performance in early detection of demagnetization is also introduced and validated numerically and experimentally. Finally, the method's efficacy is experimentally assessed under standstill and flying shaft conditions, along with its impact on synchronous startup in sensorless control of SM-PMSMs and its effectiveness in early demagnetization detection.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 11658-11671
A Self-Tuning Algorithm for Misalignment Detection and Efficiency Optimization in Double-Sided LCC -Based DWPT Systems
Achieving high efficiency in dynamic wireless power transfer (DWPT) systems has always been a critical challenge, particularly in applications such as electric vehicle (EV) charging. This challenge becomes even more profound under coil misalignment, which significantly impacts power transfer efficiency and system performance. Hence, this article presents a self-tuning, misalignment-tolerant algorithm to maximize the efficiency in DWPT systems utilizing double-sided LCC compensation networks. Unlike previous studies that primarily focus on resistive loads, this work addresses realistic scenarios involving battery loads with both resistive and reactive characteristics. In addition, it tackles misalignment during dynamic EV charging by integrating a novel misalignment detection technique and an innovative efficiency optimization algorithm. The proposed method utilizes real-time analysis of the harmonic spectrum of the primary-side current, specifically the ratio of the third harmonic to the fundamental harmonic ( ${I}_{p}^{\mathrm {\mathrm {3rd}}}/{I}_{p}^{\mathrm {\mathrm {1st}}}$ ), to detect misalignment and determine the coupling factor without the need for additional hardware and communication links. By employing the derived analytical equations, the algorithm dynamically adjusts the switching frequency and phase shift of the front-end inverter to achieve maximum efficiency. The proposed approach is validated through MATLAB simulations, and its practical feasibility is demonstrated using an experimental 1.8 kW DWPT setup, achieving significant efficiency improvements under varying load and alignment conditions.
- 17 June 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 11658-11671
A Self-Tuning Algorithm for Misalignment Detection and Efficiency Optimization in Double-Sided LCC -Based DWPT Systems
Achieving high efficiency in dynamic wireless power transfer (DWPT) systems has always been a critical challenge, particularly in applications such as electric vehicle (EV) charging. This challenge becomes even more profound under coil misalignment, which significantly impacts power transfer efficiency and system performance. Hence, this article presents a self-tuning, misalignment-tolerant algorithm to maximize the efficiency in DWPT systems utilizing double-sided LCC compensation networks. Unlike previous studies that primarily focus on resistive loads, this work addresses realistic scenarios involving battery loads with both resistive and reactive characteristics. In addition, it tackles misalignment during dynamic EV charging by integrating a novel misalignment detection technique and an innovative efficiency optimization algorithm. The proposed method utilizes real-time analysis of the harmonic spectrum of the primary-side current, specifically the ratio of the third harmonic to the fundamental harmonic ( ${I}_{p}^{\mathrm {\mathrm {3rd}}}/{I}_{p}^{\mathrm {\mathrm {1st}}}$ ), to detect misalignment and determine the coupling factor without the need for additional hardware and communication links. By employing the derived analytical equations, the algorithm dynamically adjusts the switching frequency and phase shift of the front-end inverter to achieve maximum efficiency. The proposed approach is validated through MATLAB simulations, and its practical feasibility is demonstrated using an experimental 1.8 kW DWPT setup, achieving significant efficiency improvements under varying load and alignment conditions.
- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (2) , 1156-1163
Dynamic Response and Filtering Capability Improvement of $\alpha \beta$-Frame Cascaded Delayed Signal Cancellation Based PLL
Blocking the grid voltage imbalance through the$\alpha \beta$ -frame delayed signal cancellation ($\alpha \beta$ DSC) operator requires a relatively high delay value of$1/4$ cycle. Since the dynamic behavior of the$\alpha \beta$ -frame cascaded delayed signal cancellation based phase-locked loop ($\alpha \beta$ CDSC-PLL) depends on the total delay length of the cascaded operators, this value can slow down the dynamic response. In this paper, however, inspired by the delayed signal cancelation (DSC) concept, an enhanced$\alpha \beta$ -frame DSC operator, which removes the grid voltage imbalance with a delay length of only$1/12$ cycle, is proposed. The small-signal model of the suggested frequency adaptive operator is derived, making the tuning procedure and stability analysis easy yet effective. Due to the shorter delay length, using the proposed operator in the$\alpha \beta$ CDSC-PLL structure leads to a higher speed-of-response and, therefore, a less phase-angle error during grid voltage scenarios. Moreover, when the total delay length decreases, the filtering capability will be improved using more operators at the chain of the cascaded DSC operators. The performance of the$\alpha \beta$ CDSC-PLL and its suggested enhanced structure, benefiting from the proposed operator, are compared through theoretical analysis and experimental tests, which verify that the proposed structure offers a better dynamic response and filtering capability.- 21 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 37 (2) , 1156-1163
Dynamic Response and Filtering Capability Improvement of $\alpha \beta$-Frame Cascaded Delayed Signal Cancellation Based PLL
Blocking the grid voltage imbalance through the$\alpha \beta$ -frame delayed signal cancellation ($\alpha \beta$ DSC) operator requires a relatively high delay value of$1/4$ cycle. Since the dynamic behavior of the$\alpha \beta$ -frame cascaded delayed signal cancellation based phase-locked loop ($\alpha \beta$ CDSC-PLL) depends on the total delay length of the cascaded operators, this value can slow down the dynamic response. In this paper, however, inspired by the delayed signal cancelation (DSC) concept, an enhanced$\alpha \beta$ -frame DSC operator, which removes the grid voltage imbalance with a delay length of only$1/12$ cycle, is proposed. The small-signal model of the suggested frequency adaptive operator is derived, making the tuning procedure and stability analysis easy yet effective. Due to the shorter delay length, using the proposed operator in the$\alpha \beta$ CDSC-PLL structure leads to a higher speed-of-response and, therefore, a less phase-angle error during grid voltage scenarios. Moreover, when the total delay length decreases, the filtering capability will be improved using more operators at the chain of the cascaded DSC operators. The performance of the$\alpha \beta$ CDSC-PLL and its suggested enhanced structure, benefiting from the proposed operator, are compared through theoretical analysis and experimental tests, which verify that the proposed structure offers a better dynamic response and filtering capability.- Open Access
- 2 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (14) , 2573-2580
Impact of resources distribution on high‐frequency behaviour of photovoltaic systems
In this study, the distribution effect of grid‐connected inverters in photovoltaic (PV) plants is analysed. In fact, the interaction dynamics between different arrangements of distributed PV inverters and the grid are thoroughly compared. To this aim, the total power of all arrangements of distributed inverters is considered constant, which is called fixed‐power arrangements in this work. Accordingly, this study first develops the model of grid‐connected current‐controlled inverters (CCIs). Then, by applying the impedance‐based criterion, the effect of CCIs distribution on their stability is evaluated. Despite the fact that each CCI model is obtained based on the same stability margins, different distributed arrangements of CCIs have different interaction dynamics with the grid. From the frequency‐domain analysis, it is found that the distribution effect of CCIs can greatly affect the high‐frequency (HF) behaviour of their output admittances, and consequently improves their interaction dynamics; hence, one of the factors which can also play an important role in HF behaviour is distribution effect of CCIs in a PV plant. The simulation studies of several distributed arrangements of CCIs as well as a centralised CCI confirm the validity of the performed analysis.
- 2 October 2020
- Published by Institution of Engineering and Technology (IET) in IET Renewable Power Generation
- Vol. 14 (14) , 2573-2580
Open AccessImpact of resources distribution on high‐frequency behaviour of photovoltaic systems
In this study, the distribution effect of grid‐connected inverters in photovoltaic (PV) plants is analysed. In fact, the interaction dynamics between different arrangements of distributed PV inverters and the grid are thoroughly compared. To this aim, the total power of all arrangements of distributed inverters is considered constant, which is called fixed‐power arrangements in this work. Accordingly, this study first develops the model of grid‐connected current‐controlled inverters (CCIs). Then, by applying the impedance‐based criterion, the effect of CCIs distribution on their stability is evaluated. Despite the fact that each CCI model is obtained based on the same stability margins, different distributed arrangements of CCIs have different interaction dynamics with the grid. From the frequency‐domain analysis, it is found that the distribution effect of CCIs can greatly affect the high‐frequency (HF) behaviour of their output admittances, and consequently improves their interaction dynamics; hence, one of the factors which can also play an important role in HF behaviour is distribution effect of CCIs in a PV plant. The simulation studies of several distributed arrangements of CCIs as well as a centralised CCI confirm the validity of the performed analysis.
- 30 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (2) , 594-601
A Common-Ground Quazi-Z-Source Single-Phase Inverter Suitable for Photovoltaic Applications
In this paper, a coupled inductor common-ground single-phase inverter well-suited for photovoltaic (PV) applications is presented. The proposed PV inverter is constructed based on a two-stage DC-AC topology. At first stage, a high gain DC-DC structure converts PV low voltage to the high bipolar output voltages which are desired for the conventional half-bridge inverter in second stage. The parasitic capacitors between the PV panel and its ground in conventional configurations, provide the path for circulating the leakage current. This problem is tackled in the proposed topology by making a common ground structure. Furthermore, the first stage is owned by only one switch with low voltage stress which leads to a great suppression in conduction losses. The proposed DC-AC structure has the ability to reduce the input current ripple and recycle the leakage energy caused by coupled inductor. The operation principles of the proposed structure are analyzed in details and finally, the experimental results have been accomplished to confirm the accuracy of the performed analysis.
- 30 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (2) , 594-601
A Common-Ground Quazi-Z-Source Single-Phase Inverter Suitable for Photovoltaic Applications
In this paper, a coupled inductor common-ground single-phase inverter well-suited for photovoltaic (PV) applications is presented. The proposed PV inverter is constructed based on a two-stage DC-AC topology. At first stage, a high gain DC-DC structure converts PV low voltage to the high bipolar output voltages which are desired for the conventional half-bridge inverter in second stage. The parasitic capacitors between the PV panel and its ground in conventional configurations, provide the path for circulating the leakage current. This problem is tackled in the proposed topology by making a common ground structure. Furthermore, the first stage is owned by only one switch with low voltage stress which leads to a great suppression in conduction losses. The proposed DC-AC structure has the ability to reduce the input current ripple and recycle the leakage energy caused by coupled inductor. The operation principles of the proposed structure are analyzed in details and finally, the experimental results have been accomplished to confirm the accuracy of the performed analysis.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 570-573
mHealth Platform for Breast Cancer Risk Assessment
Early detection of breast cancer plays an important role in survival of the patients. As smart phones have a massive impact on our lifestyle, we are seeking to decrease the time gap of onset and detection of breast cancer using a mobile phone app. In this paper, we discuss a web-based software application platform that can be used by any patient on their smart phone to automatically score the risk of breast cancer as well as to connect with their doctors for further assessment, support and action. A clinical study of this 'app' will be carried out in the next phase of the project.
- 1 October 2015
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 570-573
mHealth Platform for Breast Cancer Risk Assessment
Early detection of breast cancer plays an important role in survival of the patients. As smart phones have a massive impact on our lifestyle, we are seeking to decrease the time gap of onset and detection of breast cancer using a mobile phone app. In this paper, we discuss a web-based software application platform that can be used by any patient on their smart phone to automatically score the risk of breast cancer as well as to connect with their doctors for further assessment, support and action. A clinical study of this 'app' will be carried out in the next phase of the project.