Ravindra Kumar Jain
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ravindra Kumar Jain has a total of 79 co-authors. Here are the top co-authors by number of shared publications:
Arthi Balasubramaniam
8 shared publicationsAkriti Tiwari
Department of Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Chennai, India
4 shared publicationsArya S. Prasad
Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
4 shared publicationsManjiri Bhate
Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
4 shared publicationsArshya A Kumar
3 shared publications- Arthi Balasubramaniam
Department of Public Health Dentistry, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical sciences, Saveetha University, Chennai, Tamil Nadu, India
3 shared publications
Latest Publications
- Open Access
- 23 October 2026
- Published by Wolters Kluwer Health in Journal of International Oral Health
Variations of Mandibular Buccal Shelf Anatomy in Different Vertical and Sagittal Growth Patterns: A Systematic Review and Meta-Analysis
Background: The mandibular buccal shelf (MBS) is the preferred extra-alveolar site for orthodontic mini-implant placement, offering dense cortical bone and adequate distance from tooth roots. Literature studies report the varying influence of facial patterns on MBS architecture and its subsequent implications on anchorage. Aim: To evaluate MBS anatomical variations, namely, width, height, and cortical thickness, across different vertical and sagittal skeletal growth patterns using cone-beam computed tomography (CBCT)-based studies. Methods: An electronic search was conducted across PubMed, Scopus, Cochrane, and Web of Science until April 2026, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Cross-sectional CBCT studies evaluating MBS dimensions were included. Risk of bias was assessed using the Joanna Briggs Institute critical appraisal tool. Eleven studies comprising 1732 subjects met the eligibility criteria. Meta-analysis was done to investigate the impact of vertical growth patterns on MBS width at 5 mm and height at 3 mm from the alveolar crest. Results: Eight of 11 included studies had a low risk of bias. They reported varying MBS width and height in hypodivergent subjects (2.5–7.9 mm; 12.7–23.6 mm) and hyperdivergent subjects (1.8–7.0 mm; 11.0–21.1 mm). MBS height and cortical thickness yielded inconsistent findings across vertical patterns. Meta-analysis demonstrated significant differences in MBS width and height between hypodivergent and hyperdivergent growers ( P < .05). However, pooled analysis failed to show statistically significant differences in MBS dimensions among vertical growth patterns ( P > 0.05). The majority of studies reported no significant variation in MBS architecture among different sagittal skeletal patterns Conclusion: Hypodivergent subjects had higher MBS width, and hyperdivergent subjects had lower MBS height than other growth patterns ( P < .05) in the region adjoining both the mesial and distal halves of second molars. Evidence regarding MBS dimension variations among different sagittal skeletal patterns remains inconclusive.
- 23 October 2026
- Published by Wolters Kluwer Health in Journal of International Oral Health
Open AccessVariations of Mandibular Buccal Shelf Anatomy in Different Vertical and Sagittal Growth Patterns: A Systematic Review and Meta-Analysis
Background: The mandibular buccal shelf (MBS) is the preferred extra-alveolar site for orthodontic mini-implant placement, offering dense cortical bone and adequate distance from tooth roots. Literature studies report the varying influence of facial patterns on MBS architecture and its subsequent implications on anchorage. Aim: To evaluate MBS anatomical variations, namely, width, height, and cortical thickness, across different vertical and sagittal skeletal growth patterns using cone-beam computed tomography (CBCT)-based studies. Methods: An electronic search was conducted across PubMed, Scopus, Cochrane, and Web of Science until April 2026, following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. Cross-sectional CBCT studies evaluating MBS dimensions were included. Risk of bias was assessed using the Joanna Briggs Institute critical appraisal tool. Eleven studies comprising 1732 subjects met the eligibility criteria. Meta-analysis was done to investigate the impact of vertical growth patterns on MBS width at 5 mm and height at 3 mm from the alveolar crest. Results: Eight of 11 included studies had a low risk of bias. They reported varying MBS width and height in hypodivergent subjects (2.5–7.9 mm; 12.7–23.6 mm) and hyperdivergent subjects (1.8–7.0 mm; 11.0–21.1 mm). MBS height and cortical thickness yielded inconsistent findings across vertical patterns. Meta-analysis demonstrated significant differences in MBS width and height between hypodivergent and hyperdivergent growers ( P < .05). However, pooled analysis failed to show statistically significant differences in MBS dimensions among vertical growth patterns ( P > 0.05). The majority of studies reported no significant variation in MBS architecture among different sagittal skeletal patterns Conclusion: Hypodivergent subjects had higher MBS width, and hyperdivergent subjects had lower MBS height than other growth patterns ( P < .05) in the region adjoining both the mesial and distal halves of second molars. Evidence regarding MBS dimension variations among different sagittal skeletal patterns remains inconclusive.
- 25 August 2026
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 27 (6) , 584-591
Synthesis and Evaluation of Antimicrobial, Anti-inflammatory, and Antioxidant Activities of a 4-Hydroxycinnamic Acid Dentifrice for Orthodontic Subjects: An In Vitro Study
To prepare and test the antimicrobial (AM), anti-inflammatory, and antioxidant activities of a novel dentifrice containing 4-hydroxycinnamic acid (4-HCA). A novel base dentifrice was formulated with 0.2% 4-HCA (group II) and 0.4% 4-HCA (group III), and compared against a standard commercial dentifrice: Colgate Strong Teeth toothpaste (group I). Antimicrobial activity against Streptococcus mutans (SM), Lactobacillus acidophilus (LA), Candida albicans (CA), and Enterococcus faecalis (EF) was assessed by agar well diffusion zone of inhibition (ZOI), minimum inhibitory concentration (MIC), and minimum bactericidal concentration (MBC). Anti-inflammatory effects were evaluated using bovine serum albumin (BSA) denaturation and red blood cell (RBC) membrane stabilization assays. Antioxidant potential was measured by hydroxyl radical scavenging and ferric reducing antioxidant power (FRAP) assays. Statistical analysis utilized one-way analysis of variance (ANOVA) with appropriate post-hoc tests for ZOI and (p < 0.05). Group III exhibited significantly larger ZOIs against SM (39 ± 5.477 mm) as compared to group I (18.6 ± 2.4) (p = 0.05). The MIC for SM and LA was 0.5 mg/mL for all groups. Minimum bactericidal concentration was 0.5 mg/mL for LA and for SM in group III, whereas it was 5 mg/mL for all other groups. Minimum bactericidal concentration was 5 mg/mL for groups II and III. For anti-inflammatory activity, group III showed 43% inhibition in BSA denaturation at a concentration of 10 μg/mL, while group I showed 41% inhibition (p = 0.3). Similarly, groups II and III demonstrated antioxidant effects in the FRAP assay (66.28 and 66.49%, respectively) vs group I (64.89%) at 10 μg/mL (p = 0.5). The novel dentifrice containing 0.4% 4-HCA demonstrated significant in vitro AM activity, particularly against SM, and exhibited promising anti-inflammatory and antioxidant properties compared to Colgate dentifrice. These findings highlight the potential of 4-HCA dentifrice as an adjunctive oral hygiene aid to reduce the risk of white spot lesions (WSLs) in orthodontic patients, underscoring the need for future clinical trials to establish its efficacy and safety. A dentifrice containing 4-HCA may serve as a promising adjunct in orthodontic patients for controlling microbial load and reducing the risk of WSLs. Beyond its in vitro efficacy, these findings indicate potential clinical translation as a preventive oral hygiene measure that could be incorporated into routine orthodontic care to improve enamel protection and treatment outcomes, provided future in vivo studies confirm its safety and effectiveness.
- 25 August 2026
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 27 (6) , 584-591
Synthesis and Evaluation of Antimicrobial, Anti-inflammatory, and Antioxidant Activities of a 4-Hydroxycinnamic Acid Dentifrice for Orthodontic Subjects: An In Vitro Study
To prepare and test the antimicrobial (AM), anti-inflammatory, and antioxidant activities of a novel dentifrice containing 4-hydroxycinnamic acid (4-HCA). A novel base dentifrice was formulated with 0.2% 4-HCA (group II) and 0.4% 4-HCA (group III), and compared against a standard commercial dentifrice: Colgate Strong Teeth toothpaste (group I). Antimicrobial activity against Streptococcus mutans (SM), Lactobacillus acidophilus (LA), Candida albicans (CA), and Enterococcus faecalis (EF) was assessed by agar well diffusion zone of inhibition (ZOI), minimum inhibitory concentration (MIC), and minimum bactericidal concentration (MBC). Anti-inflammatory effects were evaluated using bovine serum albumin (BSA) denaturation and red blood cell (RBC) membrane stabilization assays. Antioxidant potential was measured by hydroxyl radical scavenging and ferric reducing antioxidant power (FRAP) assays. Statistical analysis utilized one-way analysis of variance (ANOVA) with appropriate post-hoc tests for ZOI and (p < 0.05). Group III exhibited significantly larger ZOIs against SM (39 ± 5.477 mm) as compared to group I (18.6 ± 2.4) (p = 0.05). The MIC for SM and LA was 0.5 mg/mL for all groups. Minimum bactericidal concentration was 0.5 mg/mL for LA and for SM in group III, whereas it was 5 mg/mL for all other groups. Minimum bactericidal concentration was 5 mg/mL for groups II and III. For anti-inflammatory activity, group III showed 43% inhibition in BSA denaturation at a concentration of 10 μg/mL, while group I showed 41% inhibition (p = 0.3). Similarly, groups II and III demonstrated antioxidant effects in the FRAP assay (66.28 and 66.49%, respectively) vs group I (64.89%) at 10 μg/mL (p = 0.5). The novel dentifrice containing 0.4% 4-HCA demonstrated significant in vitro AM activity, particularly against SM, and exhibited promising anti-inflammatory and antioxidant properties compared to Colgate dentifrice. These findings highlight the potential of 4-HCA dentifrice as an adjunctive oral hygiene aid to reduce the risk of white spot lesions (WSLs) in orthodontic patients, underscoring the need for future clinical trials to establish its efficacy and safety. A dentifrice containing 4-HCA may serve as a promising adjunct in orthodontic patients for controlling microbial load and reducing the risk of WSLs. Beyond its in vitro efficacy, these findings indicate potential clinical translation as a preventive oral hygiene measure that could be incorporated into routine orthodontic care to improve enamel protection and treatment outcomes, provided future in vivo studies confirm its safety and effectiveness.
- 1 July 2026
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
Assessment of Operator Experience on the Accuracy and Time Required for Intraoral Scanning with Three Different Scanners: A Prospective Study
Introduction: Digital workflows in orthodontics increasingly rely on Intraoral Scanning (IOS) due to their advantages in efficiency, patient comfort, and precision. However, the impact of operator experience on scan performance remains a critical factor, especially with the introduction of new scanning technologies. Aim: To evaluate the influence of operator experience on scanning time and accuracy using three different Intraoral Scanners (IOS). Materials and Methods: The present prospective study was conducted at Saveetha Dental College, Chennai, Tamil Nadu, India from November 2024 to December 2024. Twenty adult participants underwent IOS performed by three operators with differing levels of experience: high (>50 scans), moderate (10- 50 scans), and low (<10 scans). The study design was based on operator experience levels, with three subgroups corresponding to the type of IOS used: TRIOS 5 (3Shape), Runyes Threedimensional (3D) and Cerec Primescan AC. Each participant was scanned nine times, once by each operator using all three scanners, resulting in a total of 180 intraoral scans. Outcome measures included scanning time and accuracy. Statistical analysis was performed using Statistical Package for Social Sciences (SPSS) software, with intergroup differences assessed by Analysis of Variance (ANOVA) and correlations analysed using Kendall’s tau. A p-value of ≤0.05 was considered significant. Results: Scanning time was significantly influenced by operator experience (p0.05). TRIOS 5 demonstrated the shortest scan times (1.24±0.14 minutes), while Primescan AC required the longest (5.78±0.64 minutes). Conclusion: Operators with high experience required less time to scan, irrespective of the scanner type used. The accuracy of scanning doesn’t depend on the operator’s experience or the type of scanner used. Clinically, enhancing operator skill can improve workflow efficiency and patient comfort without compromising scan quality.
- 1 July 2026
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
Assessment of Operator Experience on the Accuracy and Time Required for Intraoral Scanning with Three Different Scanners: A Prospective Study
Introduction: Digital workflows in orthodontics increasingly rely on Intraoral Scanning (IOS) due to their advantages in efficiency, patient comfort, and precision. However, the impact of operator experience on scan performance remains a critical factor, especially with the introduction of new scanning technologies. Aim: To evaluate the influence of operator experience on scanning time and accuracy using three different Intraoral Scanners (IOS). Materials and Methods: The present prospective study was conducted at Saveetha Dental College, Chennai, Tamil Nadu, India from November 2024 to December 2024. Twenty adult participants underwent IOS performed by three operators with differing levels of experience: high (>50 scans), moderate (10- 50 scans), and low (<10 scans). The study design was based on operator experience levels, with three subgroups corresponding to the type of IOS used: TRIOS 5 (3Shape), Runyes Threedimensional (3D) and Cerec Primescan AC. Each participant was scanned nine times, once by each operator using all three scanners, resulting in a total of 180 intraoral scans. Outcome measures included scanning time and accuracy. Statistical analysis was performed using Statistical Package for Social Sciences (SPSS) software, with intergroup differences assessed by Analysis of Variance (ANOVA) and correlations analysed using Kendall’s tau. A p-value of ≤0.05 was considered significant. Results: Scanning time was significantly influenced by operator experience (p0.05). TRIOS 5 demonstrated the shortest scan times (1.24±0.14 minutes), while Primescan AC required the longest (5.78±0.64 minutes). Conclusion: Operators with high experience required less time to scan, irrespective of the scanner type used. The accuracy of scanning doesn’t depend on the operator’s experience or the type of scanner used. Clinically, enhancing operator skill can improve workflow efficiency and patient comfort without compromising scan quality.
- 1 May 2026
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
Microbial Adhesion and Biofilm Formation on Clear Aligners: A Literature Review
Oral cavity is a host for a variety of microorganisms, these microbes tend to adhere to retentive areas in the oral cavity such as deep occlusal grooves on posterior teeth, interdental areas and form biofilm. This leads to the development of dental caries and gingivitis. Patients undergoing fixed appliance orthodontic treatment are more prone for enamel demineralisation caused by adherence of microbial colonies. Clear aligners, which are made of clear thermoplastic material are commonly used in clinical practice recently. Clear aligners are a series of plastic trays which have to be worn for 22 hours a day for effective tooth movement and have to be changed for every two weeks. These aligners cover the tooth completely, making it difficult for the antibacterial effect of saliva to act on the tooth surfaces. Hence, the present review aimed to assess the microbial adhesion and biofilm formation in patients undergoing clear aligner therapy and the effectiveness of various methods to clean aligners.
- 1 May 2026
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
Microbial Adhesion and Biofilm Formation on Clear Aligners: A Literature Review
Oral cavity is a host for a variety of microorganisms, these microbes tend to adhere to retentive areas in the oral cavity such as deep occlusal grooves on posterior teeth, interdental areas and form biofilm. This leads to the development of dental caries and gingivitis. Patients undergoing fixed appliance orthodontic treatment are more prone for enamel demineralisation caused by adherence of microbial colonies. Clear aligners, which are made of clear thermoplastic material are commonly used in clinical practice recently. Clear aligners are a series of plastic trays which have to be worn for 22 hours a day for effective tooth movement and have to be changed for every two weeks. These aligners cover the tooth completely, making it difficult for the antibacterial effect of saliva to act on the tooth surfaces. Hence, the present review aimed to assess the microbial adhesion and biofilm formation in patients undergoing clear aligner therapy and the effectiveness of various methods to clean aligners.
- 30 April 2026
- Published by Facultad de Odontologia, Universidad de Concepcion in Journal of Oral Research
- Vol. 15 (1) , 102-117
Mechanical, Physical And Optical Properties Comparison Between Direct Printed And Thermoformed Aligners - A Systematic Review
Background: Clear aligners are a popular choice for orthodontic treatment due to their aesthetic appeal, comfort, and the ability to be easily taken on and off, unlike fixed appliances, which cannot be removed once treatment begins. Two common fabrication methods for aligners are direct 3D printing and thermoforming. This systematic review aims to compare the mechanical, physical, and optical properties of 3D-printed aligners (DPAs) and thermoformed aligners (TFAs) to provide evidence-based insights for clinicians and researchers. Material and Methods: A comprehensive literature search was conducted in electronic data-bases, including PubMed, Scopus, Web of Science and Google Scholar, to identify studies evaluating and comparing DPAs and TFAs. Studies were selected based on predefined inclusion and exclusion criteria, focusing on outcomes such as load-deflection behavior, dimensional accuracy, tensile strength, force decay, thickness, and transparency. The quality of the included studies was assessed using the RoBDEMAT tool for in vitro studies and the ROBINS-I tool for in vivo studies. Data synthesis involved narrative and qualitative approaches to summarize the findings. Results: A total of ten studies were included, comprising eight in vitro studies and two in vivo studies. The included studies exhibited moderate risk of bias due to insufficient reporting of randomization and operator blinding. DPAs demonstrated superior dimensional accuracy, thickness uniformity, and optical properties compared toTFAs. However, TFAs exhibited better force retention and consistent load. While the mechanical strength of DPAs was higher, TFAs showed greater stability in long-term force delivery. Conclusions: DPAs provide superior precision and aesthetics, while TFAs offer better durability and sustained force retention, highlighting the need for case-specific aligner selection.
- 30 April 2026
- Published by Facultad de Odontologia, Universidad de Concepcion in Journal of Oral Research
- Vol. 15 (1) , 102-117
Mechanical, Physical And Optical Properties Comparison Between Direct Printed And Thermoformed Aligners - A Systematic Review
Background: Clear aligners are a popular choice for orthodontic treatment due to their aesthetic appeal, comfort, and the ability to be easily taken on and off, unlike fixed appliances, which cannot be removed once treatment begins. Two common fabrication methods for aligners are direct 3D printing and thermoforming. This systematic review aims to compare the mechanical, physical, and optical properties of 3D-printed aligners (DPAs) and thermoformed aligners (TFAs) to provide evidence-based insights for clinicians and researchers. Material and Methods: A comprehensive literature search was conducted in electronic data-bases, including PubMed, Scopus, Web of Science and Google Scholar, to identify studies evaluating and comparing DPAs and TFAs. Studies were selected based on predefined inclusion and exclusion criteria, focusing on outcomes such as load-deflection behavior, dimensional accuracy, tensile strength, force decay, thickness, and transparency. The quality of the included studies was assessed using the RoBDEMAT tool for in vitro studies and the ROBINS-I tool for in vivo studies. Data synthesis involved narrative and qualitative approaches to summarize the findings. Results: A total of ten studies were included, comprising eight in vitro studies and two in vivo studies. The included studies exhibited moderate risk of bias due to insufficient reporting of randomization and operator blinding. DPAs demonstrated superior dimensional accuracy, thickness uniformity, and optical properties compared toTFAs. However, TFAs exhibited better force retention and consistent load. While the mechanical strength of DPAs was higher, TFAs showed greater stability in long-term force delivery. Conclusions: DPAs provide superior precision and aesthetics, while TFAs offer better durability and sustained force retention, highlighting the need for case-specific aligner selection.
- 24 April 2026
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 27 (2) , 124-129
In Vitro Evaluation of Surface Morphology and Roughness of TiO2-coated Clear Aligners Using Scanning Electron Microscopy and Atomic Force Microscopy
The study aimed to characterize the surface morphology and evaluate the surface roughness of clear aligners (CAs) coated with titanium dioxide (TiO2) nanoparticles. In this in vitro study, thermoformed PETG samples (n = 20) were equally divided into TiO2-coated and noncoated groups. Coated samples underwent TiO2 nanoparticle deposition via radiofrequency (RF) magnetron sputtering. All samples were analyzed using scanning electron microscopy (SEM) for surface morphology, energy dispersive X-ray analysis (EDAX) for elemental composition, and atomic force microscopy (AFM) for surface roughness. Parameters assessed included average surface roughness (Ra), root mean square roughness (Rms), and mean peak height (mh). Statistical analysis was performed using SPSS v22.0; intergroup comparisons were made using the independent t-test. Scanning electron microscopy images showed a uniform, crack-free TiO2 coating in the coated group, while the control group lacked such features. Energy dispersive X-ray analysis confirmed the presence of titanium and oxygen in the coated samples only. Atomic force microscopy results revealed significantly lower surface roughness values in the coated group: Ra (5.17 ± 1.28 nm), Rms (6.77 ± 1.62 nm), mh (36.11 ± 9.27 nm) compared to the control: Ra (11.96 ± 5.80 nm), Rms (14.72 ± 6.30 nm), mh (51.00 ± 7.42 nm) (p < 0.05). Titanium dioxide-coated aligners demonstrated reduced surface roughness and improved surface morphology over non-coated aligners. Titanium dioxide nanoparticle coating may enhance the clinical performance of CAs by improving surface quality and reducing potential bacterial adhesion. How to cite this article: Padmanabhan SV, Kalathur Sridev A, Sankaranarayanan V, et al. In Vitro Evaluation of Surface Morphology and Roughness of TiO2-coated Clear Aligners Using Scanning Electron Microscopy and Atomic Force Microscopy. J Contemp Dent Pract 2026;27(2):124-129.
- 24 April 2026
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 27 (2) , 124-129
In Vitro Evaluation of Surface Morphology and Roughness of TiO2-coated Clear Aligners Using Scanning Electron Microscopy and Atomic Force Microscopy
The study aimed to characterize the surface morphology and evaluate the surface roughness of clear aligners (CAs) coated with titanium dioxide (TiO2) nanoparticles. In this in vitro study, thermoformed PETG samples (n = 20) were equally divided into TiO2-coated and noncoated groups. Coated samples underwent TiO2 nanoparticle deposition via radiofrequency (RF) magnetron sputtering. All samples were analyzed using scanning electron microscopy (SEM) for surface morphology, energy dispersive X-ray analysis (EDAX) for elemental composition, and atomic force microscopy (AFM) for surface roughness. Parameters assessed included average surface roughness (Ra), root mean square roughness (Rms), and mean peak height (mh). Statistical analysis was performed using SPSS v22.0; intergroup comparisons were made using the independent t-test. Scanning electron microscopy images showed a uniform, crack-free TiO2 coating in the coated group, while the control group lacked such features. Energy dispersive X-ray analysis confirmed the presence of titanium and oxygen in the coated samples only. Atomic force microscopy results revealed significantly lower surface roughness values in the coated group: Ra (5.17 ± 1.28 nm), Rms (6.77 ± 1.62 nm), mh (36.11 ± 9.27 nm) compared to the control: Ra (11.96 ± 5.80 nm), Rms (14.72 ± 6.30 nm), mh (51.00 ± 7.42 nm) (p < 0.05). Titanium dioxide-coated aligners demonstrated reduced surface roughness and improved surface morphology over non-coated aligners. Titanium dioxide nanoparticle coating may enhance the clinical performance of CAs by improving surface quality and reducing potential bacterial adhesion. How to cite this article: Padmanabhan SV, Kalathur Sridev A, Sankaranarayanan V, et al. In Vitro Evaluation of Surface Morphology and Roughness of TiO2-coated Clear Aligners Using Scanning Electron Microscopy and Atomic Force Microscopy. J Contemp Dent Pract 2026;27(2):124-129.
- Open Access
- 29 October 2025
- Published by MM Publishers
- Vol. 16 (3) , 17-34
Long-Term Evaluation of White Spot Lesion Treatment with Resin Infiltration in Orthodontic Subjects- A Systematic Review And Meta-Analysis
Background: Resin infiltration (RI) has been used to treat white spot lesions (WSLs) and minimize caries development. The non-cavitated initial carious lesions can be filled with resin to prevent further caries progression. Long-term effects of RI have been reported but there is a need to systematically review the literature. Aim and objectives: To systematically search, collate, and assess the literature on treatment effectiveness and stability with RI technique for the management of WSLs in orthodontic patients over a six to twenty-four-month follow-up period. Materials and methods: A literature search was performed from January 2019 to December 2023 in four electronic databases (PubMed, Cochrane library, Google Scholar and Scopus). Studies including patients with permanent dentition treated for WSLs during or after orthodontic treatment, with at least 6 months of followup were only included in the review. Risk of bias assessment was done using the Cochrane ROB-2 tool for randomized clinical trials (RCTs) and the ROBINS-I tool for non-RCTs. GRADE assessment was done for the certainty of evidence of the included studies. A random effects model was used to perform the meta-analysis of the color change and area of lesion regression. Results: Eight studies including six RCTs and two non-RCTs were included. Treatment with RI showed significant lesion area regression and negligible color change over 6–24 months. The meta-analysis showed no significant difference in lesion area between RI and CPP-ACP at 12 months(effect size z = 1.42), and a significant improvement in color change at 6 months (effect size z=4.38, favoring RI over micro abrasion, with no heterogeneity. (I2 = 0%). Conclusion: This systematic review based on strong evidence reports that RI is an effective treatment for WSLs, with significant improvement in color and lesion area regression. Moreover, its effectiveness was maintained over six months, hence it is stable and long-lasting.
- 29 October 2025
- Published by MM Publishers
- Vol. 16 (3) , 17-34
Open AccessLong-Term Evaluation of White Spot Lesion Treatment with Resin Infiltration in Orthodontic Subjects- A Systematic Review And Meta-Analysis
Background: Resin infiltration (RI) has been used to treat white spot lesions (WSLs) and minimize caries development. The non-cavitated initial carious lesions can be filled with resin to prevent further caries progression. Long-term effects of RI have been reported but there is a need to systematically review the literature. Aim and objectives: To systematically search, collate, and assess the literature on treatment effectiveness and stability with RI technique for the management of WSLs in orthodontic patients over a six to twenty-four-month follow-up period. Materials and methods: A literature search was performed from January 2019 to December 2023 in four electronic databases (PubMed, Cochrane library, Google Scholar and Scopus). Studies including patients with permanent dentition treated for WSLs during or after orthodontic treatment, with at least 6 months of followup were only included in the review. Risk of bias assessment was done using the Cochrane ROB-2 tool for randomized clinical trials (RCTs) and the ROBINS-I tool for non-RCTs. GRADE assessment was done for the certainty of evidence of the included studies. A random effects model was used to perform the meta-analysis of the color change and area of lesion regression. Results: Eight studies including six RCTs and two non-RCTs were included. Treatment with RI showed significant lesion area regression and negligible color change over 6–24 months. The meta-analysis showed no significant difference in lesion area between RI and CPP-ACP at 12 months(effect size z = 1.42), and a significant improvement in color change at 6 months (effect size z=4.38, favoring RI over micro abrasion, with no heterogeneity. (I2 = 0%). Conclusion: This systematic review based on strong evidence reports that RI is an effective treatment for WSLs, with significant improvement in color and lesion area regression. Moreover, its effectiveness was maintained over six months, hence it is stable and long-lasting.
- Open Access
- 1 May 2025
- Published by Wolters Kluwer Health in Journal of International Society of Preventive and Community Dentistry
- Vol. 15 (3) , 222-233
Effectiveness of Clear Aligner Therapy in Maxillary Molar Distalization for Class II Malocclusion: A Systematic Review of Clinical Studies
Aim: Addressing skeletal Class II (CII) malocclusion often involves molar distal movement (Dx). While traditional methods like headgear face challenges related to patient compliance, clear aligner therapy (CAT) is considered an appealing alternative, although its effectiveness in molar Dx is an ongoing study area. This systematic review (SR) seeks to review the recent studies on the efficacy of CAT for effecting molar Dx. The aim of this SR was to assess the effectiveness of CAT in achieving molar Dxs in individuals with sagittal CII malocclusion. Materials and Methods: A comprehensive search in five electronic databases (Scopus, PubMed, Google Scholar, Cochrane, and Web of Science) for relevant articles till December 2023 was performed. The population, intervention, comparision, outcome and study design criteria included subjects with CII malocclusion intervened with CAT, the control was no treatment or fixed appliance therapy using traditional methods of molar distalization, and the outcomes assessed were molar Dx, achieved vs. predicted movements, molar tipping, and rotation. Only prospective trials, retrospective studies, randomized controlled trials (RCTs), and controlled clinical trials were included. The principal measure of Dx was millimeters. The risk of bias (ROB) assessment of the included studies was conducted using the Newcastle–Ottawa scale and ROBINS-I tool. Preferred reporting items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were adopted for data reporting and synthesis. The SR was registered in the PROSPERO database (registration number CRD42024531205). Results: Out of 547 studies identified, 11 papers were included in the present SR. Eight of them were retrospective, and three were prospective studies. The sample size ranged from a minimum of seven to 49 patients. A total of 278 patients were assessed in all the studies. Invisalign® system CA was used in all studies. Five studies reported predicted vs. achieved tooth movements. Two studies reported the use of attachments, and one study reported the use of microimplants for preventing anchorage loss along with Class I elastics. Dx ranged from 0.67 ± 0.5 mm to 2.54 ± 0.12 mm. When compared to the predicted Dx, the achieved Dx for M6 was 36.48–75.5%; for M7, it was 41.94–72.2%, and the accuracy of derotation of molars was 62.7–77.5%. Quantitative analysis could not be performed owing to the heterogeneity in the included studies. Six included studies had a low ROB, and two of them had a moderate ROB. Three studies were ranked low quality on the Newcastle–Ottawa scale. The strength of evidence for the included studies was judged as moderate on assessment with the Agency for Healthcare Research and Quality criteria. Conclusion: The available moderate-quality evidence suggests that CAT can achieve molar Dx up to 2 mm with good accuracy. However, the included studies were mainly retrospective with lesser samples without adequate controls; also, there was a wide variation in measurement methods and evaluation times. Well-designed RCTs are required to validate these findings and provide more robust evidence.
- 1 May 2025
- Published by Wolters Kluwer Health in Journal of International Society of Preventive and Community Dentistry
- Vol. 15 (3) , 222-233
Open AccessEffectiveness of Clear Aligner Therapy in Maxillary Molar Distalization for Class II Malocclusion: A Systematic Review of Clinical Studies
Aim: Addressing skeletal Class II (CII) malocclusion often involves molar distal movement (Dx). While traditional methods like headgear face challenges related to patient compliance, clear aligner therapy (CAT) is considered an appealing alternative, although its effectiveness in molar Dx is an ongoing study area. This systematic review (SR) seeks to review the recent studies on the efficacy of CAT for effecting molar Dx. The aim of this SR was to assess the effectiveness of CAT in achieving molar Dxs in individuals with sagittal CII malocclusion. Materials and Methods: A comprehensive search in five electronic databases (Scopus, PubMed, Google Scholar, Cochrane, and Web of Science) for relevant articles till December 2023 was performed. The population, intervention, comparision, outcome and study design criteria included subjects with CII malocclusion intervened with CAT, the control was no treatment or fixed appliance therapy using traditional methods of molar distalization, and the outcomes assessed were molar Dx, achieved vs. predicted movements, molar tipping, and rotation. Only prospective trials, retrospective studies, randomized controlled trials (RCTs), and controlled clinical trials were included. The principal measure of Dx was millimeters. The risk of bias (ROB) assessment of the included studies was conducted using the Newcastle–Ottawa scale and ROBINS-I tool. Preferred reporting items for Systematic Reviews and Meta-Analysis (PRISMA) guidelines were adopted for data reporting and synthesis. The SR was registered in the PROSPERO database (registration number CRD42024531205). Results: Out of 547 studies identified, 11 papers were included in the present SR. Eight of them were retrospective, and three were prospective studies. The sample size ranged from a minimum of seven to 49 patients. A total of 278 patients were assessed in all the studies. Invisalign® system CA was used in all studies. Five studies reported predicted vs. achieved tooth movements. Two studies reported the use of attachments, and one study reported the use of microimplants for preventing anchorage loss along with Class I elastics. Dx ranged from 0.67 ± 0.5 mm to 2.54 ± 0.12 mm. When compared to the predicted Dx, the achieved Dx for M6 was 36.48–75.5%; for M7, it was 41.94–72.2%, and the accuracy of derotation of molars was 62.7–77.5%. Quantitative analysis could not be performed owing to the heterogeneity in the included studies. Six included studies had a low ROB, and two of them had a moderate ROB. Three studies were ranked low quality on the Newcastle–Ottawa scale. The strength of evidence for the included studies was judged as moderate on assessment with the Agency for Healthcare Research and Quality criteria. Conclusion: The available moderate-quality evidence suggests that CAT can achieve molar Dx up to 2 mm with good accuracy. However, the included studies were mainly retrospective with lesser samples without adequate controls; also, there was a wide variation in measurement methods and evaluation times. Well-designed RCTs are required to validate these findings and provide more robust evidence.
- 1 April 2025
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
Adhesive Removal Procedures in Orthodontics: A Literature Review
The removal of residual adhesive after orthodontic bracket debonding is a critical step in restoring enamel surface integrity while minimising damage. Over the years, multiple techniques have been developed to remove orthodontic adhesive, including mechanical, chemical, and laser-based methods. While current methods are effective in removing adhesive residues, many are associated with enamel surface damage, time inefficiency, or patient discomfort. Given the widespread use of adhesive removal instruments by orthodontists, it is essential to have scientific knowledge about these techniques and their biological impact on tooth structure. Consequently, it is crucial to select effective removal methods that minimise damage to the patient at the end of treatment and, whenever possible, preserve the tooth’s original condition. Most authors prefer using a combination of abrasives and rotary speeds for effective appliance debonding, although the optimal choice of abrasive and speed remains unclear. Tungsten carbide burs receive the most favourable reviews in the literature, making them the recommended technique. Although the laser is more comfortable due to the lack of noise, vibration, or pressure, it creates a much rougher surface and is less effective compared to conventional methods. The present review aimed to summarise the available evidence on adhesive removal techniques reported in the literature and discuss their effects on the enamel surface and its integrity post-orthodontic treatment.
- 1 April 2025
- Published by JCDR Research and Publications in Journal of Clinical and Diagnostic Research
Adhesive Removal Procedures in Orthodontics: A Literature Review
The removal of residual adhesive after orthodontic bracket debonding is a critical step in restoring enamel surface integrity while minimising damage. Over the years, multiple techniques have been developed to remove orthodontic adhesive, including mechanical, chemical, and laser-based methods. While current methods are effective in removing adhesive residues, many are associated with enamel surface damage, time inefficiency, or patient discomfort. Given the widespread use of adhesive removal instruments by orthodontists, it is essential to have scientific knowledge about these techniques and their biological impact on tooth structure. Consequently, it is crucial to select effective removal methods that minimise damage to the patient at the end of treatment and, whenever possible, preserve the tooth’s original condition. Most authors prefer using a combination of abrasives and rotary speeds for effective appliance debonding, although the optimal choice of abrasive and speed remains unclear. Tungsten carbide burs receive the most favourable reviews in the literature, making them the recommended technique. Although the laser is more comfortable due to the lack of noise, vibration, or pressure, it creates a much rougher surface and is less effective compared to conventional methods. The present review aimed to summarise the available evidence on adhesive removal techniques reported in the literature and discuss their effects on the enamel surface and its integrity post-orthodontic treatment.