ZSZhang Shiling

Zhang Shiling

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Zhang Shiling has a total of 4 co-authors. Here are the top co-authors by number of shared publications:

  • Baojia Deng

    State Grid Chongqing Electric Power Company Chongqing Electric Power Research Institute, Chongqing, 401123

    1 shared publication
  • Lin Gong

    State Grid Chongqing Electric Power Company Chongqing Electric Power Research Institute, Chongqing, 401123

    1 shared publication
  • Song Wei

    State Grid Chongqing Electric Power Company Chongqing Electric Power Research Institute, Chongqing, 401123

    1 shared publication
  • Yang Huaxia

    State Grid Chongqing Electric Power Company Chongqing Electric Power Research Institute, Chongqing, 401123

    1 shared publication

Latest Publications

  • Open Access

    Research on Digital Twin Virtual Model of UHV Core Power Equipment

    by Shiling Zhang

    In this paper, voltage equalization, corona prevention and noise reduction are studied by using finite element calculation method and multi-objective optimization algorithm for UHV substation, series compensation circuit, transmission line, DC valve hall and outdoor field. The calculation model of multi parameter and multi-objective optimization design is established, the optimal configuration parameters of voltage equalizing structure are obtained, the electric field distribution uniformity and structure rationalization are realized, the corona discharge is effectively restrained, the key technology of voltage equalizing and anti corona is solved, the cost is reduced, the efficiency is improved, and a simulation calculation and optimization design platform with independent intellectual property rights is formed. The research results have been successfully applied to UHV projects in China.


  • Open Access

    Study on Structure Type and Operation Condition of UHVDC Wall Bushing

    by Shiling Zhang, Lin Gong, Baojia Deng

    When the ±800kV UHVDC capacity is increased to 10000MW, the transmission current is 5kA and 6.25kA, which will put forward new requirements for the key technology of UHVDC through wall bushing: in UHV level, the key of through wall bushing lies in the research of basic technology of voltage sharing and field sharing. In the case of large current carrying capacity, the key lies in the basic technology research of current sharing and heat sharing. When the DC wall bushing, converter bushing and outgoing line device operate at the rated voltage, the central conductor is heated due to the carrying large DC current. Therefore, the temperature field distribution inside and at the tail of the bushing core is uneven, and the resistivity is the function of temperature, resulting in the change of resistivity with temperature and the change of potential and electric field distribution with resistivity during operation. Therefore, under the above high current operation conditions, in-depth key technology research is required for the design of bushing current carrying device, calculation of internal potential and electric field distribution, voltage sharing, field sharing, current sharing and heat sharing technology. The combined action of electrical and thermal stress will significantly affect the internal electric field distribution of converter transformer core and accelerate the aging rate of core composite insulation material, which introduces new research topic for the key technology of UHVDC converter bushing. The electric field and voltage distribution of UHVDC bushing are theoretically analyzed, the insulation structure is optimized from the aspects of material and structure, and the manufacturing process and the test technology are deeply and systematically studied.


  • Open Access

    Electro-thermal Coupling Model for Radial Temperature and Electric Field Distribution Computation and Experimental Research of 550kV RIP AC Oil-gas Bushings

    by Zhang Shiling, Song Wei, Yang Huaxia

    The condenser of 550kV RIP oil-gas bushings is in the solid structure of resin-epoxy impregnated paper(RIP), which has large difference with the oil-immersed one (OIP). Oil-gas bushings has compact configuration and heat conduction condition is harsh, while temperature distribution has direct relationship with bushings’ long-term stable operation performance, so it’s essential to carry out research in radial temperature within condenser during production of RIP oil-gas bushing prototype. In this paper, radial temperature distribution principle of bushing condenser under linear material conditions has been summarized by building electrothermal coupling theoretical model of bushing condenser. The model has been generalized by electro-thermal coupling finite element mode under nonlinear material conditions, and electrothermal coupling iterative computation process has also been proposed, then experimental measurement study in local temperature points of bushing condenser has been carried out. The study shows that plate model has advantages of high accuracy and simple form in calculating radial temperature distribution of bushing condenser; the hot-spot temperature of 550kV RIP oil-gas bushings is about 95°C which appears near the center conductor; radial temperature of bushings under nonlinear material conditions is lower than that under linear material conditions and the thermal breakdown voltage of condenser under rated current is 538kV which is higher than the maximum operation phase voltage. This paper provides theoretical foundation for radial temperature computation within RIP bushing condenser and has some reference value for the design of HVAC RIP bushings.

  • Open Access

    Study on insulation performance of environmental protection C5-PFK gas mixture based on time sharing and mutual fiber sensing detection technology

    by Zhang Shiling

    With the proposal of China’s goal of carbon peak and carbon neutralization, it is urgent for C5-PFK environment-friendly gas insulating medium to replace SF6 in key power equipment, and the research on C5-PFK mixed gas on-line detection technology should be carried out in advance. In view of this, this project is the first time to apply the time-sharing mutual optical fiber sensing detection technology to the C5-PFK mixed gas insulation and decomposition performance research. Theoretical and software analysis: the insulation and decomposition characteristics of C5-PFK gas mixture were simulated from the molecular dynamics level. The variation of absorption spectrum with the temperature and pressure was simulated by self programming simulation software platform, and coupling field distribution of electric power equipment in C5-PFK insulation environment was obtained. The grey system and the NSGA-II hybrid algorithm are applied to inverse and predict the decomposed gas concentration high coupling and nonlinear data series. Hardware and device development: develop a time-sharing and interactive optical fiber live detection device to achieve quantitative online acquisition of decomposition components of mixed gas. Build a real test platform for testing the power frequency, lightning and switching impulse performance of gas mixture. The influence of high frequency vibration and large temperature difference on the experimental results is solved by optimizing the optical system through structure iteration. The time-sharing and interactive optical fiber sensing detection technology can realize the detection of C5-PFK mixed gas with high sensitivity and wide concentration range, which provides theoretical and experimental basis for China’s dual carbon target construction demonstration project, and has good economic and social benefits.


  • Open Access

    Structure Optimization of UHV RIP Oil-SF6 bushings Based on Improved Equal Margin Design Method and Back-Propagation Neural Network

    by Zhang Shiling

    Equal margin design method based on the classic analytic formula is widely used in development of extra-high voltage bushing products, and its effectiveness and practicality have been fully validated. However, model and temperature factors have significant impact on internal E-field distribution of UHVAC and UHVDC bushing condenser, which traditional analytic formula is difficult to evaluate quantitatively, so it’s necessary to improve traditional equal margin design method. Firstly, basic principles of equal margin design method and its software package were briefly described, and the laws of model and temperature factors influencing on condenser E-field were investigated on FEM (finite element method) computing platform. Based on these, mathematical model of improved equal margin design method for bushing condenser was established, and flow chart of optimization process combining FEM electro-thermal coupling calculation with genetic algorithm was presented. The improved method was applied to design of UHV RIP oil-gas prototype to realize uniform axial E-field distribution along bushing condenser and equal partial discharge margin between adjacent foils. Bushing condenser was fabricated according to above optimized design structure, and has passed all type tests. In the paper, the FEM electro-thermal coupling calculation method was applied to the inner insulation optimization design to make bushing condenser’s design more suitable. The paper can provide some theoretical guidelines for research and development of other bushings in UHV level.


  • Open Access

    Research on operation characteristics of UHV converter valve hall based on intelligent image processing and 3D modeling technology

    by Zhang Shiling

    There are many power equipments in the UHV valve hall, including the converter transformer, converter valve tower, all kinds of bushing, tubular bus. The operation condition monitoring of the above main equipment mainly includes electrical performance parameter measurement, oil and gas insulation medium performance parameter measurement and other means. This paper mainly introduces a monitoring method for the operation status of converter valve hall from the perspective of image processing technology. The technology mainly includes: 1) the application of intelligent image processing technology to identify and classify the database of infrared thermal imager and ultraviolet imager; 2) the real-time on-line measurement for the insulation distance of typical fittings through Kalman filter technology, including the measurement of the hottest temperature The insulation distance between partial discharge point and zero potential grounding point; 3) the electric field simulation model of typical main equipment in valve hall is established based on three-dimensional modeling technology of finite element method, and the surface electric field distribution of key main equipment fittings is obtained. Combined with the image database information, insulation distance information and typical main equipment electric field distribution information, the operation state parameters are effectively obtained, and the intelligent algorithm is applied to automatically evaluate its operation state, discover the latent fault and locate the positive fault, so as to provide effective data support and the protection strategy for the main equipment operation and maintenance.


  • Open Access

    Theory and Experimental Study of Corona Initial E-Field Strength of HVDC Large Fittings

    by Zhang Shiling

    The electrode were used to imitate the valve tower shield plate, grading ring, grading ball and grading shield for UHVDC valve hall. Uneven electric field of the irregular conductor can not be calculated theoretically or measured accurately. The variation of typical electrode corona inception electric field strength is analyzed and threshold value of the corona inception electric field of the valve hall fittings is acquired. With the adequate modification, limited electric field magnitude for the valve hall is proposed. With the gray system MGM (1, M) model fitting and predicting technology, the E-field strength single-point high-precision measurement and the the wide-area time interval corona initial E-field fitting and predicting operation can be realized. The experimental results show that the maximum error is 3.25% within the measured concentration range, which increases with applied voltage. The maximum RSD% is less than 2.7%, showing the good stability. This system can provide the novel method for the study of corona detection of large fittings in UHVDC valve hall.