DUDeepak Upadhyay

Deepak Upadhyay

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Deepak Upadhyay has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Transient Inductance in a High-Speed Axially Laminated SynRM: Parameter Sensitivity and Its Impact on Converter Characteristics

    by Deepak Upadhyay, Houyi Ma, Shruti Singh, Ilya Petrov, Aleksi Mattsson, Pasi Peltoniemi, Lassi Aarniovuori, Juha Pyrhönen

    This article presents a comprehensive investigation into the transient inductance of a 27 kW, 100 000 rpm high-speed axially laminated anisotropic synchronous reluctance machine (ALASynRM). While traditional transversally laminated rotor synchronous reluctance machines exhibit significant angular dependence of transient inductance, this study reveals and theoretically quantifies the spatial invariance of this parameter in solid-rotor ALASynRMs due to high-frequency eddy current shielding in the conductive laminate layers. A refined finite element method (FEM) modeling approach is proposed that integrates 3-D end-winding leakage effects and material resistivity sensitivity to overcome the limitations of standard 2-D magnetic analysis. This modeling framework is rigorously validated through experimental measurements on a high-speed prototype, demonstrating a maximum deviation of 6.3% and an average deviation of only 2.5%. The article establishes a novel design-oriented theoretical framework that links the machine’s transient electromagnetic behavior directly to power converter performance. By quantifying the impact of transient inductance on current ripple and total harmonic distortion (THD), a systematic methodology for selecting optimal switching frequencies and DC-link voltages is provided. This approach ensures high-performance operation while accounting for the inherent computational constraints of high-speed motor controllers.


  • Open Access

    Enhancing Power Quality in Quadruple Boost Nine‐Level Inverter With Advanced PWM and Bee Algorithm‐based SHE and SHM

    by Deepak Upadhyay, Shahbaz Ahmad Khan, Mohd Tariq, Adil Sarwar, Pasi Peltoniemi

    This paper presents a comprehensive modulation‐based performance enhancement of a quadruple‐boost nine‐level switched‐capacitor inverter (QB9LSCI) for improved power quality, efficiency and practical implementation. Two level‐shifted carrier waveforms, namely WM‐type and UM‐type carriers, are proposed for high‐frequency PWM operation and compared with conventional triangular and full‐parabolic carriers. The modulation methods are evaluated in terms of voltage and current total harmonic distortion (THD), capacitor‐voltage ripple, semiconductor loss distribution, efficiency and dynamic response. The proposed WM‐type carrier provides the best performance among the carrier‐based methods, reducing the output‐voltage THD to 5.71% and current THD to 0.56%, while achieving lower capacitor‐voltage ripple and higher efficiency. For low‐switching‐frequency operation, selective harmonic elimination (SHE) and selective harmonic mitigation (SHM) are implemented using bee algorithm‐optimised switching angles. The bee algorithm converges within approximately 30 iterations, compared with 150–200 iterations required by PSO, DE and GA under identical optimisation settings. The SHM method further reduces the output‐voltage THD from 10.63% (SHE) to 6.63% by mitigating a wider harmonic range within prescribed limits. Loss and efficiency analyses show that SHE and SHM significantly reduce switching losses, making them suitable for high‐power steady‐state operation, whereas WM‐carrier PWM provides superior controllability and dynamic response for medium‐power applications. The proposed modulation strategies are validated through MATLAB/Simulink, PLECS loss analysis and experimental results from a 500–1000 W hardware prototype. The results demonstrate that the proposed QB9LSCI with the proposed modulation strategies offers an effective trade‐off between harmonic performance, efficiency, implementation simplicity and application flexibility.

  • Open Access

    Feasible Operating Boundary Extraction for MW‐Class SiC Inverters in High‐Speed Drives

    by Deepak Upadhyay, Aleksi Mattsson, Pasi Peltoniemi

    Advances in wide‐bandgap (WBG) semiconductors now enable inverter designs capable of operating at higher speeds, higher voltages, and significantly greater power levels. Operating at high fundamental and switching frequencies enables improved power density, reduced current and voltage distortion, and enhanced overall drive efficiency. However, their practical extension to low‐voltage megawatt‐class systems is constrained by device paralleling, semiconductor losses, thermal management, current distortion, and implementation complexity. This paper presents a PLECS‐based electrothermal feasibility framework for extracting feasible operating boundaries of MW‐class SiC inverters for high‐speed drives. The main objective is to identify the maximum feasible switching frequency and engineering applicability limits of different topology, device, DC‐link, and modulation‐technique combinations under simultaneous constraints of efficiency, semiconductor junction temperature, and output‐current total harmonic distortion (THD). Two‐level, T‐type neutral‐point‐clamped (T‐NPC), and active neutral‐point‐clamped (ANPC) inverter topologies are evaluated using commercially available SiC discrete MOSFETs and power modules at 800 V and 1500 V DC‐link levels. The study evaluates switching and conduction losses, total harmonic distortion (THD), efficiency, and junction temperature across varying frequencies and modulation strategies, including space vector pulse‐width modulation (SVPWM) and discontinuous pulse‐width modulation (DPWM) variants. Suitable feasible solutions achieving efficiency, THD , and balanced cost–thermal trade‐offs are presented. A 25 kW SiC inverter prototype is used to validate the PLECS electrothermal model and support the predicted loss, efficiency, and temperature trends.

  • Open Access

    System-Level Switching-Frequency Trade-Offs in a High-Fundamental-Frequency MW-Class PMSM Drive

    by Hüseyin Tayyer Canseven, Deepak Upadhyay, Saeid Deliri, Ilya Petrov, Aleksi Mattsson, Frede Blaabjerg, Lassi Aarniovuori, Pasi Peltoniemi, Juha Pyrhönen


  • Open Access

    High-Efficiency, High-Fundamental Frequency Inverter for High-Speed Electrical Drive in a Micro Gas Turbine-Based Vehicle Powertrain

    by Deepak Upadhyay, Ching-Lon Huang, Aleksi Mattsson, Ilya Petrov, Pasi Peltoniemi

    This paper presents the design, analysis, and validation of a high-efficiency inverter for high-speed electric drives in micro gas turbine (MGT)-based vehicle powertrains. A 30 kW, 700 VDC, two-level, three-phase voltage source inverter (VSI) using silicon carbide (SiC) MOSFETs is developed to operate at a 2 kHz fundamental and 40 kHz switching frequency. Unlike conventional inverters operating at 50–60 Hz, this design supports high-speed motors (above 100,000 rpm) by increasing the fundamental frequency to 2 kHz. A detailed comparison between two-level and three-level T-type topologies is conducted, with the selected topology maintaining over 99% efficiency across a wide frequency range. The design incorporates detailed loss modelling, a low-inductance PCB layout, and optimized DC-link capacitor selection to ensure robust high-frequency operation. The influence of modulation index and switching frequency ratio on inverter efficiency and current total harmonic distortion (THD) is analyzed, highlighting their impact on thermal performance and current quality. Thermal simulations using PLECS estimate a peak efficiency of 99.3%. The design is validated through simulation and experimental testing on a 30 kW prototype, achieving 14.3 kW/L power density and 25 kW/kg gravimetric density. Comparative analysis with recent literature confirms the proposed inverter's advantages in power density, efficiency, and high-frequency capability.


  • Open Access

    Review on Silicon Carbide-Based High-Fundamental Frequency Inverters for High-Speed Drives

    by Deepak Upadhyay, Saeid Deliri, Aleksi Mattsson, Pasi Peltoniemi, Lassi Aarniovuori

    This article provides a comprehensive review of Silicon Carbide (SiC) based inverters designed for High-Speed (HS) drive applications, which require higher output frequencies to enhance efficiency and power density. The review analyzes approximately 70 recent three-phase SiC inverter designs, categorizing them by topology, specifically two-level, Neutral Point Clamped (NPC), T-type, and Multilevel—and discussing their advantages, limitations, and emerging trends. It also examines key design considerations, including the selection of fundamental and switching frequencies, optimization of DC-link voltage, and thermal management. Furthermore, the paper reviews industrial SiC prototypes, recent advancements in SiC device technologies, and various configurations (discrete, parallel, and module), highlighting the advantages and challenges associated with each approach. The analysis identifies a research gap in the development of high-power inverters (greater than 1 MW) capable of operating above 1 kHz fundamental frequencies. The paper concludes by outlining future research directions aimed at advancing SiC inverter technology for HS drives.


  • Open Access

    Implementation of NLC‐SHM based novel PWM scheme on packed U‐cell multilevel inverter

    by Mohd Tariq, Shahbaz Ahmad Khan, Deepak Upadhyay, Adil Sarwar, Arif Sarwat, Pasi Peltoniemi

    This article introduces a novel integrated nearest level controller (NLC) combined with selective harmonic mitigation (SHM) control approach aimed at efficiently suppressing lower‐order harmonics has been introduced. The proposed methodology is implemented on the PUC‐7 inverter topology, leveraging the combined benefits offered by both NLC and SHM controllers through a hybrid model. The proposed method demonstrates the capability to reduce lower‐order harmonics up to the 49th harmonic from the load voltage. The particle swarm optimization algorithm is employed to determine optimal switching angles and their corresponding nearest levels, thereby reducing implementation time, computational complexity, and overall system intricacy. The performance analysis of the proposed control strategy across various scenarios, including fluctuations in modulation index and monitoring diverse parameters such as load dynamics has been performed. This approach yields a significant reduction in total harmonic distortion in both load voltage and current. A comparative analysis between NLC, selective harmonic mitigation (SHM), and the integrated NLC‐SHM approach is carried out on the PUC‐7 inverter. The integrated SHM‐NLC control is implemented and validated using the MATLAB Simulink environment, complemented by hardware‐based experimentation, to ascertain its effectiveness.


  • Open Access

    Novel Integrated NLC-SHE Control Applied in Cascaded Nine-Level H-Bridge Multilevel Inverter and Its Experimental Validation

    by Mohd Tariq, Deepak Upadhyay, Shahbaz Ahmad Khan, Waleed Alhosaini, Pasi Peltoniemi, Adil Sarwar

    In this paper, a novel integrated SHE - NLC control is proposed for the mitigation of unwanted lower-order harmonics in the cascaded H-bridge multilevel inverter. The proposed algorithm has been developed by hybridizing the NLC and SHE methods, in an attempt to keep the merits of both the individual control. The switching angles and nearest levels are calculated by applying the Genetic Algorithm (GA). The proposed technique reduces the calculation time and implementation complexity, thus can be a viable alternative to the real time implementation for SHE. Integrated NLC-SHE control is tested by varying the modulation index and load dynamics. This technique resulted in the reduction in Total Harmonic Distortion (THDs) in load voltage and current. Comparative analysis of NLC, SHE and Integrated NLC-SHE technique is also performed on the CHB nine-level inverter. There is significant reduction in voltage and current THD values and power losses. Efficiency of the inverter is increased. The efficacy of the proposed control CHB nine-level is tested on MATLAB Simulink environment and further validated by experimental results.


  • Open Access

    Thirteen-Level UXE-Type Inverter With 12-Band Hysteresis Current Control Employing PSO Based PI Controller

    by Deepak Upadhyay, Mohammad Ali, Mohd Tariq, Shahbaz Ahmad Khan, Basem Alamri, Ahmad Alahmadi

    This work presents hysteresis control applied to UXE-type inverter topology with a PI (Proportional Integral) controller, where the gains are derived by Particle Swarm Optimization (PSO). The investigated UXE inverter can generate a thirteen-level output voltage waveform, which results in lower switching losses. It can boost the output voltage to 1.5 times the applied input DC source voltage. Satisfactory inverter operation is ensured by employing twelve-band hysteresis current control. The tuning of the PI controller required for the closed-loop hysteresis current control is achieved by nature-inspired PSO algorithm. A comparative analysis is also performed after obtaining the results applying nature-inspired PSO and conventional Ziegler Nichols (ZN) methods. The effectiveness of the control strategy is verified in the MATLAB Simulink and further validated in experiment using TMS320F28379D and also with Typhoon Hardware in Loop Technology.


  • Open Access

    Genetic Algorithm Based PI Control with 12-Band Hysteresis Current Control of an Asymmetrical 13-Level Inverter

    by Mohammad Ali, Mohd Tariq, Deepak Upadhyay, Shahbaz Ahmad Khan, Kuntal Satpathi, Basem Alamri, Ahmad Aziz Alahmadi

    In this paper, a twelve-band hysteresis control is applied to a recent thirteen-level asymmetrical inverter topology by employing a robust proportional-integral (PI) controller whose parameters are decided online by genetic algorithm (GA). The asymmetrical inverter topology can generate thirteen levels of output voltage incorporating only ten switches and exhibits boosting capability. A 12-band hysteresis current control strategy is applied to ensure the satisfactory operation of the inverter. It is designed to provide a sinusoidal line current at the unity power factor. The tuning of the PI controller is achieved by a nature inspired GA. Comparative analysis of the results obtained after application of the GA and the conventional Ziegler–Nichols method is also performed. The efficacy of the proposed control on WE topology is substantiated in the MATLAB Simulink environment and was further validated through experimental/real-time implementation using DSC TMS320F28379D and Typhoon HIL real-time emulator (Typhoon-HIL-402).