Muaiyed Mahmoud Buzayan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Muaiyed Mahmoud Buzayan has a total of 60 co-authors. Here are the top co-authors by number of shared publications:
Indumathi Sivakumar
SEGi Univ, Fac Dent, Dept Prosthodont Dent, Petaling Jaya, Selangor, Malaysia
6 shared publicationsNorsiah Yunus
Univ Malaya, Fac Dent, Dept Restorat Dent, Kuala Lumpur, Malaysia
5 shared publications- Indumathi Sivakumar
Associate Professor, Faculty of Dentistry, SEGi University, Selangor, Malaysia
4 shared publications Omar Tawfiq
Faculty of Dentistry, SEGi University, Selangor, Malaysia
4 shared publicationsSuchismita Choudhary
Lecturer in Prosthodontics, Faculty of Dentistry, SEGi University, Selangor, Malaysia
4 shared publications- Norsiah Binti Yunus
Department of Restorative Dentistry, Faculty of Dentistry, University of Malaya, Kuala Lumpur, Malaysia
3 shared publications
Latest Publications
- Open Access
- 31 March 2026
- Published by Knowledge E DMCC in Dubai Medical Journal
- Vol. 9 (S1) , 5-17
Comparative In-vitro Analysis of Fracture Strength in 3D-printed VarseoSmile TriniQ Resin Versus Milled Monolithic Zirconia Endocrowns: Advancing Restorative Material Performance
Introduction: Restoring endodontically treated teeth requires materials that balance mechanical strength and tooth preservation. Endocrowns provide a conservative approach compared to conventional post-and-core restorations. While monolithic zirconia is widely used for its superior fracture resistance, novel 3D-printed materials like VarseoSmile TriniQ offer potential advantages in digital workflows and restorability. This study compares the fracture resistance and failure patterns of monolithic zirconia and VarseoSmile TriniQ endocrowns to evaluate their suitability for clinical application. Methods: Eighteen extracted human molars were randomly assigned to two groups (n = 9 per group). Standardized endodontic treatment was performed, followed by endocrown preparation. Monolithic zirconia endocrowns were milled using CAD/CAM technology, while VarseoSmile TriniQ endocrowns were fabricated using highprecision 3D printing. All restorations were cemented with dual-cure resin cement. Fracture resistance was tested using a universal testing machine, applying a compressive load until failure. Failure patterns were classified as favorable, unfavorable simple, or unfavorable complex based on whether fractures were confined to the restoration, extended into the tooth structure, or severely compromised both. Data were analyzed using the Mann–Whitney U test to determine statistical significance. Results: Zirconia endocrowns exhibited significantly higher fracture resistance (median = 3746.70 N, IQR = 1362.32 N) compared to VarseoSmile TriniQ (median = 1114.73 N, IQR = 180.66 N) (P < 0.001). Fracture patterns varied: 67% of zirconia failures were complex or destructive, compromising the natural tooth structure, whereas 60% of VarseoSmile TriniQ fractures remained confined to the restoration, sparing the tooth structure. Conclusion: Monolithic zirconia endocrowns demonstrate superior fracture resistance, making them ideal for high-load-bearing applications. However, VarseoSmile TriniQ offers a more favorable failure pattern, reducing the risk of catastrophic tooth damage. These findings suggest that while zirconia remains the preferred choice for durability, 3D-printed materials like VarseoSmile TriniQ could serve as viable alternatives in cases, prioritizing tooth preservation and digital efficiency.
- 31 March 2026
- Published by Knowledge E DMCC in Dubai Medical Journal
- Vol. 9 (S1) , 5-17
Open AccessComparative In-vitro Analysis of Fracture Strength in 3D-printed VarseoSmile TriniQ Resin Versus Milled Monolithic Zirconia Endocrowns: Advancing Restorative Material Performance
Introduction: Restoring endodontically treated teeth requires materials that balance mechanical strength and tooth preservation. Endocrowns provide a conservative approach compared to conventional post-and-core restorations. While monolithic zirconia is widely used for its superior fracture resistance, novel 3D-printed materials like VarseoSmile TriniQ offer potential advantages in digital workflows and restorability. This study compares the fracture resistance and failure patterns of monolithic zirconia and VarseoSmile TriniQ endocrowns to evaluate their suitability for clinical application. Methods: Eighteen extracted human molars were randomly assigned to two groups (n = 9 per group). Standardized endodontic treatment was performed, followed by endocrown preparation. Monolithic zirconia endocrowns were milled using CAD/CAM technology, while VarseoSmile TriniQ endocrowns were fabricated using highprecision 3D printing. All restorations were cemented with dual-cure resin cement. Fracture resistance was tested using a universal testing machine, applying a compressive load until failure. Failure patterns were classified as favorable, unfavorable simple, or unfavorable complex based on whether fractures were confined to the restoration, extended into the tooth structure, or severely compromised both. Data were analyzed using the Mann–Whitney U test to determine statistical significance. Results: Zirconia endocrowns exhibited significantly higher fracture resistance (median = 3746.70 N, IQR = 1362.32 N) compared to VarseoSmile TriniQ (median = 1114.73 N, IQR = 180.66 N) (P < 0.001). Fracture patterns varied: 67% of zirconia failures were complex or destructive, compromising the natural tooth structure, whereas 60% of VarseoSmile TriniQ fractures remained confined to the restoration, sparing the tooth structure. Conclusion: Monolithic zirconia endocrowns demonstrate superior fracture resistance, making them ideal for high-load-bearing applications. However, VarseoSmile TriniQ offers a more favorable failure pattern, reducing the risk of catastrophic tooth damage. These findings suggest that while zirconia remains the preferred choice for durability, 3D-printed materials like VarseoSmile TriniQ could serve as viable alternatives in cases, prioritizing tooth preservation and digital efficiency.
- Open Access
- 29 January 2026
- Published by Korean Council of Science Editors in Science Editing
- Vol. 13 (1) , 22-28
Patterns of scientific misconduct, time to retraction, and post-retraction citation in dental implantology from 2000 to 2024: a bibliometric study
Purpose: This study analyzed retracted publications in dental implantology research to identify reasons for retraction, characterize geographic and journal trends, quantify the time lag from publication to retraction, and assess the impact of retractions through post-retraction citation patterns.Methods: A systematic search of PubMed/MEDLINE, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), EBSCO, Retraction Watch, and Google Scholar identified retracted dental implant–related articles published between 2000 and 2024. Seventy-eight retracted articles were included. Extracted data included article title, journal, authors’ country, publication date, retraction date, retraction notice text, stated reason for retraction, journal impact factor, total citations, and citations after retraction. Descriptive statistics were used. Multiple linear regression evaluated factors associated with time to retraction, and logistic regression evaluated factors associated with post-retraction citation.Results: In the 78 identified articles, the most common reasons for retraction were image duplication or image-related discrepancies (53.8%) and data-related inaccuracies or unreliable data (23.1%). Spain accounted for the largest proportion of retracted articles (56.4%), and Clinical Oral Implants Research had the highest number of retractions. The mean time between publication and retraction was 4.44±3.70 years. Despite retraction, articles continued to be cited, receiving a mean of 6.89±8.26 citations after retraction. Logistic regression showed that the publication-to-retraction interval was the only significant predictor of post-retraction citation (odds ratio, 0.645; P=0.001).Conclusion: Retractions in dental implantology research represent a serious threat to research integrity and highlight the risk of flawed evidence persisting in the literature. Enhanced editorial vigilance, rigorous research integrity training, and faster retraction protocols are essential to safeguard evidence-based dental practice.
- 29 January 2026
- Published by Korean Council of Science Editors in Science Editing
- Vol. 13 (1) , 22-28
Open AccessPatterns of scientific misconduct, time to retraction, and post-retraction citation in dental implantology from 2000 to 2024: a bibliometric study
Purpose: This study analyzed retracted publications in dental implantology research to identify reasons for retraction, characterize geographic and journal trends, quantify the time lag from publication to retraction, and assess the impact of retractions through post-retraction citation patterns.Methods: A systematic search of PubMed/MEDLINE, Scopus, Cochrane Central Register of Controlled Trials (CENTRAL), EBSCO, Retraction Watch, and Google Scholar identified retracted dental implant–related articles published between 2000 and 2024. Seventy-eight retracted articles were included. Extracted data included article title, journal, authors’ country, publication date, retraction date, retraction notice text, stated reason for retraction, journal impact factor, total citations, and citations after retraction. Descriptive statistics were used. Multiple linear regression evaluated factors associated with time to retraction, and logistic regression evaluated factors associated with post-retraction citation.Results: In the 78 identified articles, the most common reasons for retraction were image duplication or image-related discrepancies (53.8%) and data-related inaccuracies or unreliable data (23.1%). Spain accounted for the largest proportion of retracted articles (56.4%), and Clinical Oral Implants Research had the highest number of retractions. The mean time between publication and retraction was 4.44±3.70 years. Despite retraction, articles continued to be cited, receiving a mean of 6.89±8.26 citations after retraction. Logistic regression showed that the publication-to-retraction interval was the only significant predictor of post-retraction citation (odds ratio, 0.645; P=0.001).Conclusion: Retractions in dental implantology research represent a serious threat to research integrity and highlight the risk of flawed evidence persisting in the literature. Enhanced editorial vigilance, rigorous research integrity training, and faster retraction protocols are essential to safeguard evidence-based dental practice.
- Open Access
- 27 January 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Comparative finite element analysis of stress distribution of different implant-supported crown and abutment materials
The additively manufactured definitive resins have been proposed for implant-supported restorations nowadays due to its shock absorbing capacity; however,
- 27 January 2026
- Published by Springer Nature in BMC Oral Health
- Vol. 26 (1)
Open AccessComparative finite element analysis of stress distribution of different implant-supported crown and abutment materials
The additively manufactured definitive resins have been proposed for implant-supported restorations nowadays due to its shock absorbing capacity; however,
- 6 June 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (3) , 625-631
A clinical comparison of conventional, custom tray, extraoral scanning, and photogrammetry facial recording techniques for maxillofacial prosthesis fabrication
- 6 June 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (3) , 625-631
A clinical comparison of conventional, custom tray, extraoral scanning, and photogrammetry facial recording techniques for maxillofacial prosthesis fabrication
- Open Access
- 15 July 2024
- Published by Universitas Airlangga in Dental Journal (Majalah Kedokteran Gigi)
- Vol. 57 (3) , 215-220
Post-hemimaxillectomy rehabilitation as a conservative prosthetic design to enhance functionality: A case report
Background: Oral rehabilitation through prosthetic management after cancer resection is a conservative and effective modality in improving patients’ oral health-related quality of life. However, it is challenging to obtain sufficient retention for hemimaxillectomy and edentulous cases without the use of Osseo-integrated implants. Purpose: This case aims to explain the oral rehabilitation management of post-hemimaxillectomy for edentulous patients using a hollow bulb obturator and long-term soft liner. Case: A 63-year-old female presented to the Universiti Malaya postgraduate dental clinic and complained of a loose obturator during speaking and eating and high resonance during speaking. Seven years ago, she underwent hemimaxillectomy surgery of the left hard palate for the removal of squamous cell carcinoma. Upon examination, she had an edentulous maxillary arch, with a large palatal defect; the lateral border of the defect was lined with a skin graft. The mandibular arch was partially dentate with three teeth remaining (33, 35, 43). Case Management: First, elective root canal treatment of the mandibular canines was done to use them as abutments for a mandibular overdenture. Next, a maxillary hollow bulb obturator and a mandibular overdenture were constructed. Then, after evaluating the airspace on the defect site, the lateral and posterior borders of the obturator were modified to be better utilized for retention. Conclusion: Oral rehabilitation of hemimaxillectomy cases with a hollow bulb obturator without the use of Osseo-integrated implants can be a viable option for improving patients’ mastication, and speech, after assessing the retention factors, including the seal, available undercuts, and occlusion.
- 15 July 2024
- Published by Universitas Airlangga in Dental Journal (Majalah Kedokteran Gigi)
- Vol. 57 (3) , 215-220
Open AccessPost-hemimaxillectomy rehabilitation as a conservative prosthetic design to enhance functionality: A case report
Background: Oral rehabilitation through prosthetic management after cancer resection is a conservative and effective modality in improving patients’ oral health-related quality of life. However, it is challenging to obtain sufficient retention for hemimaxillectomy and edentulous cases without the use of Osseo-integrated implants. Purpose: This case aims to explain the oral rehabilitation management of post-hemimaxillectomy for edentulous patients using a hollow bulb obturator and long-term soft liner. Case: A 63-year-old female presented to the Universiti Malaya postgraduate dental clinic and complained of a loose obturator during speaking and eating and high resonance during speaking. Seven years ago, she underwent hemimaxillectomy surgery of the left hard palate for the removal of squamous cell carcinoma. Upon examination, she had an edentulous maxillary arch, with a large palatal defect; the lateral border of the defect was lined with a skin graft. The mandibular arch was partially dentate with three teeth remaining (33, 35, 43). Case Management: First, elective root canal treatment of the mandibular canines was done to use them as abutments for a mandibular overdenture. Next, a maxillary hollow bulb obturator and a mandibular overdenture were constructed. Then, after evaluating the airspace on the defect site, the lateral and posterior borders of the obturator were modified to be better utilized for retention. Conclusion: Oral rehabilitation of hemimaxillectomy cases with a hollow bulb obturator without the use of Osseo-integrated implants can be a viable option for improving patients’ mastication, and speech, after assessing the retention factors, including the seal, available undercuts, and occlusion.
- 1 January 2024
- Vol. 27 (2) , 199-205
Designing an occlusal appliance digital protocol using an opensource 3D modeling software program: a technical report
Occlusal splints are a commonly prescribed dental appliance for the management of bruxism or temporomandibular disorders. The use of digital dental technology facilitates the fabrication of this therapeutic device. The improvements in digital technology have helped in designing and producing occlusal splints that show better precision and accuracy as well as ease of manufacturing in terms of time and materials, in addition to the option of a simple and straightforward duplication process. The present technical report describes the digital workflow steps that need to be followed to design an occlusal device in a fully digital protocol. Scans of maxillary and mandibular models were acquired in centric relation, and a virtual 3D occlusal device was designed using a free, open -source 3D modeling software program.
- 1 January 2024
- Vol. 27 (2) , 199-205
Designing an occlusal appliance digital protocol using an opensource 3D modeling software program: a technical report
Occlusal splints are a commonly prescribed dental appliance for the management of bruxism or temporomandibular disorders. The use of digital dental technology facilitates the fabrication of this therapeutic device. The improvements in digital technology have helped in designing and producing occlusal splints that show better precision and accuracy as well as ease of manufacturing in terms of time and materials, in addition to the option of a simple and straightforward duplication process. The present technical report describes the digital workflow steps that need to be followed to design an occlusal device in a fully digital protocol. Scans of maxillary and mandibular models were acquired in centric relation, and a virtual 3D occlusal device was designed using a free, open -source 3D modeling software program.
- 23 September 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 134 (1) , 268-274
A comparative evaluation of photogrammetry software programs and conventional impression techniques for the fabrication of nasal maxillofacial prostheses
- 23 September 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 134 (1) , 268-274
A comparative evaluation of photogrammetry software programs and conventional impression techniques for the fabrication of nasal maxillofacial prostheses
- 1 July 2023
- Vol. 54 (7) , 526-527
Artificial intelligence in dentistry: a review of ChatGPT's role and potential
- 1 July 2023
- Vol. 54 (7) , 526-527
Artificial intelligence in dentistry: a review of ChatGPT's role and potential
- Open Access
- 2 May 2023
- Published by Wolters Kluwer Health in Journal of Cancer Research and Therapeutics
- Vol. 20 (5) , 1640-1642
Novel swing lock denture design utilizing magnets for a patient with mandibular resection
Mandibular defects requiring reconstructions may result from mandibular resections due to benign or malignant lesions. Prosthesis-based rehabilitation of such cases represents a challenge due to various anatomical and functional limitations. Here we present a novel design for the fabrication of a swing lock denture utilizing a simplified hinge and magnets for a patient who had undergone hemimandibulectomy.
- 2 May 2023
- Published by Wolters Kluwer Health in Journal of Cancer Research and Therapeutics
- Vol. 20 (5) , 1640-1642
Open AccessNovel swing lock denture design utilizing magnets for a patient with mandibular resection
Mandibular defects requiring reconstructions may result from mandibular resections due to benign or malignant lesions. Prosthesis-based rehabilitation of such cases represents a challenge due to various anatomical and functional limitations. Here we present a novel design for the fabrication of a swing lock denture utilizing a simplified hinge and magnets for a patient who had undergone hemimandibulectomy.
- Open Access
- 24 November 2022
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 13 (1) , 57-66
Does the use of platelet-rich plasma in sinus augmentation improve the survival of dental implants? A systematic review and meta-analysis
- 24 November 2022
- Published by Elsevier in Journal of Oral Biology and Craniofacial Research
- Vol. 13 (1) , 57-66
Open AccessDoes the use of platelet-rich plasma in sinus augmentation improve the survival of dental implants? A systematic review and meta-analysis