CMChunmin Ma

Chunmin Ma

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Chunmin Ma has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of an Improved Stiffness Ellipsoid Method for Precise Robot-Positioner Collaborative Control in Friction Stir Welding

    by Cunfeng Kang, Haonan Jia, Eryang Zhao, Chunmin Ma

    This study proposes an improved stiffness ellipsoid method to enhance the stiffness and precision of robotic arms in friction stir welding (FSW) operations. The method involves establishing a joint stiffness model through static identification experiments and developing a novel stiffness index derived from the improved stiffness ellipsoid method. This index provides a refined metric for evaluating the robot’s performance under variable loads during FSW. Simulation experiments demonstrate significant improvements in welding trajectory precision and computational efficiency. The findings highlight the potential of this method to elevate FW quality and consistency.


  • Open Access

    Strength Training Characteristics of Different Loads Based on Acceleration Sensor and Finite Element Simulation

    by Bo Pang, Zhongqiu Ji, Zihua Zhang, Yunchuan Sun, Chunmin Ma, Zirong He, Xin Hu, Guiping Jiang

    Deep squat, bench press and hard pull are important ways for people to improve their strength. The use of sensors to measure force is rare. Measuring strength with sensors is extremely valuable for people to master the intensity of exercise to scientifically effective exercise. To this end, in this paper, we used a real-time wireless motion capture and mechanical evaluation system of the wearable sensor to measure the dynamic characteristics of 30 young men performing deep squat, bench press and hard pull maneuvers. The data of tibia were simulated with AnyBody 5.2 and ANSYS 19.2 to verify the authenticity. The result demonstrated that the appropriate force of the deep squat elbow joint, the hip joint and the knee joint is 40% 1RM, the appropriate force of the bench press is 40% 1RM and the appropriate force of the hard pull is 80% 1RM. The external force is the main factor of bone change. The mechanical characteristics of knee joint can be simulated after the Finite Element Analysis and the simulation of AnyBody model are verified.