NVNatalia N. Vetsheva

Natalia N. Vetsheva

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Natalia N. Vetsheva has a total of 141 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Classification of Ultrasound Features of Superficially Located Lymph Nodes

    by E. P. Fisenko, G. F. Allahverdieva, M. N. Bulanov, E. A. Busko, N. N. Vetsheva, O. V. Vozgoment, V. E. Gagonova, T. Yu. Danzanova, N. V. Zabolotskaya, A. N. Katrich, et al.

    Assessment of lymphatic drainage areas is a critical task in ultrasound (US) examination of organs and tissues involved in various pathological processes. Superficially located lymph nodes (LNs) are more accessible for US evaluation. The numerous LN changes identified in ultrasound often are challenging for interpretation. The proposed classification provides grading of the detected ultrasound features in superficial LNs into groups, facilitating a risk stratification system for LN malignancy. Objective. To stratify LN ultrasound features according to the degree of deviation from the normal pattern – from loss of benign features to appearance of signs of malignancy – and to establish a classification of changes in superficially located LN based on US findings. Results. The classification comprises six levels: normal/unchanged LNs; probably benign LN changes; indeterminate/uncertain LN changes; suspicious LN changes; highly suspicious LN changes; morphologically confirmed malignant LN. Conclusion. The presented Russian classification for risk stratification of malignancy in superficial LNs will enable a more accurate US assessment of superficial lymph nodes, allowing identification of distinct types of ultrasound structure and selection of suspicious lymph nodes for biopsy.

  • Open Access

    Strain elastography in the diagnosis of radiation-induced hypothyroidism: current state of the art

    by O. V. Andreeva, I. P. Moshurov, N. N. Vetsheva, E. P. Fisenko, О. В. Андреева, И. П. Мошуров, Н. Н. Ветшева, Е. П. Фисенко

    This review addresses the role of elastography in the diagnosis of thyroid diseases, with a focus on strain elastography (SE) as a complementary non‑invasive tool for differentiating benign and malignant thyroid nodules. The study evaluates the diagnostic capabilities and inherent limitations of SE, particularly emphasizing that its isolated application—without integration of quantitative parameters of shear wave elastography (SWE)—is constrained by high equipment‑ and operator‑dependency. Additionally, the paper highlights the utility of SE in assessing radiation‑induced hypothyroidism. The authors underscore the need for further scientific research to integrate elastography into the dynamic follow‑up of patients who have undergone radiation therapy for head and neck malignancies and locally advanced breast cancer.

  • Standardization of a breast ultrasound examination protocol. Consensus of experts of the Russian association of ultrasound diagnostic specialists in medicine (RASUDM)

    by E. Р. Fisenko, M. N. Bulanov, E. А. Busko, N. N. Vetsheva, V. E. Gagonova, T. Yu. Danzanova, N. V. Zabolotskaya, А. N. Sencha

    A standard protocol for breast ultrasound examination is presented. This document consists of a process protocol and a descriptive protocol. The process protocol describes the breast ultrasound examination technique. The descriptive protocol contains a detailed presentation of the breast ultrasound examination results, ending with a conclusion. Current domestic and international diagnostic guidelines (BI-RADS® v2025 Manual) defining indications for breast ultrasound examination are discussed. This standard protocol for breast ultrasound examination is fully consistent with current Russian clinical guidelines and does not contradict international diagnostic guidelines.

  • Contrast-enhanced ultrasound examination of a stable functioning renal transplant. Pilot study

    by S. N. Larionova, N. I. Belavina, N. N. Vetsheva, R. B. Balter

    Objective. The lack of standardized protocols and reference values for quantitative parameters in contrast-enhanced ultrasound (CEUS) of stable functioning renal transplants limits its clinical application. This study aimed to analyze CEUS quantitative parameters in recipients with stable graft function and no significant pathology on protocol biopsy, as well as to assess inter-operator reproducibility. Materials and Methods. An interventional prospective study was conducted (October 1, 2024 – March 1, 2025). 23 patients were enrolled. CEUS was performed by Resona 7 system (Mindray, China) with a convex probe (1.2–6 MHz) and SonoVue contrast agent (Bracco, Italy). Time-intensity curve (TIC) parameters were analyzed in: ROI 1 (region of interest): cortex, ROI 2 : cortex between pyramids (renal columns), ROI 3 : pyramids, ROI 4 : combined ROI 1 +ROI 2 +ROI3. Parameters assessed: Ascending Slope (AS), Arrival Time (AT), Area Under the TIC Curve (AUC), Descending Slope (DS), mean TIC intensity (mTIC), Peak Intensity (PI), Rise Time (RT), Time-to-Peak (TTP), Wash-in Area Under the Curve (WiAUC), Perfusion Index (WiAUC/RT), Wash-out AUC (WoAUC). Analysis was performed using Contrast QA software (Mindray). Inter-operator reproducibility was evaluated via intraclass correlation coefficients (ICC) and Bland-Altman analysis (mean difference, limits of agreement). Results. Mean TIC parameters (averaged between operators) were obtained for all ROIs. ROI 1 : excellent/good reproducibility for most parameters; moderate reproducibility for AS and DS (ICC 0.840 [0.662; 0.928] and 0.859 [0.697; 0.938]). ROI 2 : Excellent to good reproducibility; moderate for WiAUC (0.848 [0.678; 0.933]), RT (0.877 [0.733; 0.946]), WiAUC/RT (0.835 [0.628; 0.929]), AS (0.836 [0.653; 0.927]), and DS (0.777 [0.537; 0.899]). ROI 3 : Higher variability for WiAUC/RT (0.706 [0.418; 0.864]), AS (0.657 [0.351; 0.838]), and DS (0.752 [0.497; 0.887]). ROI 4 : Results comparable to ROI 1 . Conclusion. This study is a crucial step toward standardizing CEUS for renal transplants. It establishes the first quantitative CEUS benchmarks for stable allografts without significant pathology on protocol biopsy. The low inter-operator variability supports the clinical feasibility of using absolute TIC parameters (comparison of normal vs dysfunctional grafts) across different ultrasound systems.

  • Open Access

    Classification, Diagnosis, and Management of Patients with Biliary Sludge and Early-Stage Cholelithiasis (Literature Review and Expert Council Resolution)

    by S. R. Abdulkhakov, D. S. Bordin, O. S. Vasnev, N. N. Vetsheva, O. Yu. Zolnikova, Yu. A. Kucheryavyy, S. N. Mekhtiev, A. V. Okhlobystin, E. V. Parfenchikova, K. L. Raikhelson, et al.

    Background. On May 20, 2025, a Council of Experts was held in Moscow. The aim of the meeting was to discuss current understanding of the pathogenesis and clinical significance of biliary sludge. Key points. The following definition of biliary sludge has been established: echogenic fluid within the gallbladder cavity without a clear acoustic shadow, which shifts with changes in body position without fragmentation into fine particles. The absence of an acoustic shadow distinguishes sludge from gallstones. The International Consensus of Experts in Pancreatobiliary Diseases (2023) proposed distinguishing between biliary sludge, microlithiasis (echogenic stones ≤ 5 mm with acoustic shadowing), and larger gallstones in the gallbladder and/or ducts. When managing a patient with biliary sludge, it is important to identify the underlying disease or condition predisposing to the development of sludge. The most important factors are genetic and demographic ones, dietary habits, conditions associated with rapid weight loss, and medications that affect bile composition or gallbladder function. Biliary sludge can be asymptomatic, with dyspeptic symptoms, or lead to complications typical of gallstones. Some data suggest that sludge is associated with idiopathic pancreatitis. The primary diagnostic method for sludge is transabdominal ultrasound. If clinical manifestations characteristic of cholelithiasis complications develop, the common bile duct becomes dilated, or stones are detected in the common bile duct, additional diagnostic testing using magnetic resonance cholangiopancreatography and/or endoscopic ultrasound is recommended. Clinical observations also suggest the potential for sludge to transform into gallstones. However, the view that biliary sludge is the first stage of gallstone disease was not shared by all Council members due to the high incidence of reversible sludge. At this stage, it is proposed to consider biliary sludge more as a risk factor or a specific form of gallstone disease. The only medication shown to dissolve biliary sludge is ursodeoxycholic acid. Conclusion. The Expert Council adopted a resolution, the provisions of which emphasize the need for accurate diagnosis, individual assessment of risk factors for the development of biliary sludge, the feasibility of developing a scoring system for assessing biliary sludge, determining the location of ursodeoxycholic acid therapy for sludge, and the need to supplement the Clinical Guidelines of the Russian Ministry of Health for the diagnosis and treatment of cholelithiasis with sections devoted to the diagnosis and treatment of biliary sludge.


  • Open Access

    The role of ultrasound in the evaluation of metastatically involved regional lymph nodes in cutaneous melanoma: Clinical cases

    by E. A. Pankova, N. N. Vetsheva, E. P. Fisenko, I. S. Kruglov, M. M. Lobas, M. A. Boldyrev

    Objective. To demonstrate, using clinical cases, the diagnostic value and the role of ultrasound in assessing metastatic involvement of superficial regional lymph nodes (LN) in patients with cutaneous melanoma. Materials and Methods. Two clinical cases of patients with cutaneous melanoma and regional lymph nodes metastatic involvement are presented. Results of superficial lymph nodes ultrasound were compared with data of radiological methods (contrast-enhanced CT and SPECT) and verified by histopathological examination of surgical specimens. Results and Discussion. Case No.1 demonstrates the classic ultrasound features of lymph-node malignancy: a polycyclic outer contour, loss of corticomedullary differentiation, and a peripheral type of vascularization. In contrast, Case No. 2 shows poor ultrasound features: a rounded LN shape, focal cortical thickening, and hypoechoic areas with a few vascular loci, which are also indicative of secondary involvement. Conclusion. Ultrasound allows to suspect the secondary metastatic lymph nodes changes by the detection of a set of relevant signs in melanoma patients. It may be used as a first-line diagnostic modality to guide further diagnostic workup and treatment planning in patients with cutaneous melanoma.

  • Design and validation of a technology for 3D printing training phantoms for ultrasound imaging

    by Veronika Grebennikova, Denis Leonov, Zhuhuang Zhou, José Francisco Silva Costa-Júnior, Daria Shestakova, Manob Jyoti Saikia, Natalia Vetsheva, Nicholas Kulberg, Kristina Pashinceva, Olga Omelianskaya, et al.

    Due to high cost, training phantoms are often inaccessible and their manufacturing technologies are quite sophisticated. The purpose of this paper is to develop an inexpensive and reproducible technology for creating ultrasound training phantoms. These phantoms are a 3D printed porous medium composed of 156-µm-thick photopolymer resin fibers and include models of cysts ranging from 4 to 8 mm in diameter, effectively simulating a muscle tissue with anechoic lesions. A custom software generates a virtual phantom model, enabling precise control over its properties. We believe that the results of the acoustic characteristics’ measurements for the designed phantoms provide an opportunity to mimic muscle (1547 m/s) and breast (1510 m/s) tissues. Following the creation of the phantom, a series of assessments were conducted to evaluate its efficacy for needle insertion (involving 3 observers) and to identify its mimicked tissue type (with 29 observers participating). The findings revealed that the phantom is capable of enduring up to 300 punctures in a single location without exhibiting significant decline in image quality. A subsequent survey of ultrasound specialists, who possessed a range of professional experiences, indicated that the ultrasound images produced by the phantom predominantly corresponded to those of muscle tissues upon visual examination. The 3D printing process for the phantom 60 mm × 60 mm × 30 mm in size was completed in 3 h and 23 min. The proposed technology allows creating low-cost, long-lasting phantoms for training in ultrasound diagnostics and ultrasound-guided procedures. The phantom designed using widely available photopolymer resin, while the custom software and high-resolution 3D printing ensures reproducibility of the shape and positions of the fibers and inclusions. The phantom mimics muscle tissues with multiple cysts and can be used to develop basic coordination and navigation skills required for ultrasound diagnostics.


  • Open Access

    Contrast-enhanced ultrasound of kidney allograft in patient with acute rejection. Case report and literature review

    by N. I. Belavina, S. N. Larionova, N. N. Vetsheva, E. S. Stolyarevich, E. I. Peniaeva, N. N. Klochkova, I. V. Barkova, E. V. Parabina, A. A. Shishimorov, N. F. Frolova

    Kidney transplantation is recognized as the optimal modality of renal replacement therapy. In most cases the diagnosis of the causes of kidney allograft dysfunction and subsequent choice of treatment strategy are determined by the results of nephrobiopsy. The search for alternative noninvasive diagnostic modalities, including ultrasound, that could reveal the specific features of the most common causes of renal graft dysfunction remains relevant. Contrast-enhanced ultrasound (CEUS)is considered a promising modality for the diagnosis of renal graft dysfunction in general and of acute rejection in particular. The article presents the analysis of the results of multiparametric ultrasound in a patient with acute antibody-mediated rejection after voluntary complete withdrawal of immunosuppressive therapy. The subcapsular areas of hypoperfusion were found along with a decrease of allograft perfusion in general. The patterns of “slow wash-in – fast wash-out” of contrast medium in the medulla and “fast wash-out” in the cortex were also detected. The comparison of CEUS and histopathological data from the removed allograft identified the foci of cortical necrosis as the substrate of abnormal perfusion areas. Now it seems premature to evaluate the diagnostic capability of CEUS in complex ultrasound of renal allograft. Further research is necessary to determine the role of CEUS in the complex assessment of kidney transplant pathology.


  • Open Access

    Ultrasound capabilities in detecting gas in the portal venous system

    by N. N. Vetsheva, А. А. Sokolov, Yu. P. Zborovskaya, А. P. Stepanchenko, I. A. Semenenko, Ю. П. Зборовская

    Возможности ультразвуковой диагностики газа в системе воротной вены

  • Open Access

    Standardization of the protocol of superficial lymph node ultrasound. Consensus of experts of the Russian association of specialists of ultrasound in medicine (RASUDM)

    by E. P. Fisenko, G. F. Allahverdieva, M. N. Bulanov, Е. А. Бусько, N. N. Vetsheva, O. V. Vozgoment, V. E. Gagonova, T. Yu. Danzanova, N. V. Zabolotskaya, V. V. Kapustin, et al.

    A standard protocol for superficial lymph node (LN) ultrasound is presented. The document consists of a technological (1) and descriptive (2) protocols. The technological protocol describes the technique of superficial LN ultrasound. The descriptive protocol contains a detailed report of the results of superficial LN ultrasound, which ends with a conclusion. Modern domestic and foreign clinical and diagnostic recommendations that determine the indications for superficial LN ultrasound are analyzed. The presented standard protocol for superficial LN ultrasound fully complies with current Russian clinical recommendations and does not contradict foreign clinical and diagnostic recommendations.