Julien Chapleau
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Julien Chapleau has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Dominique M. Rouleau
Universite de Montréal, 2900 Bd Édouard-Montpetit, Montréal, QC H3T 1J4, Canada; Department of Surgery, Université de Montréal, 2900 Boul. Edouard‑Montpetit, Montreal, QC H3T 1J4, Canada; Department of Orthopedic Surgery, CIUSSS Nord-de-L'île-de-Montréal, Hôpital du Sacré-Coeur de Montréal (HSCM), 5400 Boul. Gouin Ouest, Montreal, QC H4J 1C5, Canada
3 shared publications Emilie Sandman
3 shared publicationsBatool Bosakhar
McMaster University Medical Centre, Hamilton, ON, Canada
1 shared publicationBenjamin Léger St-Jean
CIUSSS de l'Est-de-l'Île-de-Montréal, 5415, boulevard l'Assomption, Pavillon Rachel Tourigny, H1T 2M4 Montréal, QC, Canada
1 shared publication- Bradley Lambert
Department of Orthopedics and Sports Medicine, Houston Methodist Hospital, Houston, Texas
1 shared publication Claire Bastard
CIUSSS du Nord-de-l'île-de-Montréal, Hôpital du Sacré-Cœur de Montréal, C2095-5400 Boul. Gouin O, H4J 1C5 Montreal, QC, Canada; Hopital Saint Antoine, Paris, France
1 shared publication
Latest Publications
- 9 June 2026
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 80, 103532
What can be learned from 90 years of published literature on anterior-inferior hip dislocations in pediatrics?
- 9 June 2026
- Published by Elsevier in Journal of Clinical Orthopaedics and Trauma
- Vol. 80, 103532
What can be learned from 90 years of published literature on anterior-inferior hip dislocations in pediatrics?
- Open Access
- 3 June 2026
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (3) , 100789
Retrospective study comparing first- and new-generation proximal humerus locking plates in 152 proximal humerus fracture cases
- 3 June 2026
- Published by Elsevier in JSES Reviews, Reports, and Techniques
- Vol. 6 (3) , 100789
Open AccessRetrospective study comparing first- and new-generation proximal humerus locking plates in 152 proximal humerus fracture cases
- 28 May 2024
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 110 (5) , 103912
Validity, reliability and responsiveness of a French translation of the Western Ontario Osteoarthritis of the Shoulder index (WOOS)
- 28 May 2024
- Published by Elsevier in Orthopaedics & Traumatology: Surgery & Research
- Vol. 110 (5) , 103912
Validity, reliability and responsiveness of a French translation of the Western Ontario Osteoarthritis of the Shoulder index (WOOS)
- 15 February 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (5) , 1084-1091
A novel fragment specific classification of complex olecranon fractures: 3-dimensional model design, radiological validation, and proposed surgical algorithm
- 15 February 2024
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 33 (5) , 1084-1091
A novel fragment specific classification of complex olecranon fractures: 3-dimensional model design, radiological validation, and proposed surgical algorithm
- Open Access
- 8 August 2023
- Published by SAGE Publications in Journal of Orthopaedics, Trauma and Rehabilitation
- Vol. 31 (1) , 60-76
The use of three-dimensional navigation and advanced intraoperative imaging in minimally invasive pelvic and acetabular fracture fixation: A systematic review
Pelvic and acetabular fractures are challenging injuries to treat. This review evaluates three-dimensional intraoperative imaging and navigation-guided percutaneous SI, trans-iliac, trans-sacral, and acetabular screw placement versus conventional methods performed with C-arm imaging. A systematic search of MEDLINE, Embase, and Cochrane was performed. Two reviewers independently extracted data into a collaborative data form designed a priori and piloted prior to its use. Descriptive statistics are presented where applicable. Summary statistics analysis was presented based on the fracture type. Continuous data such as fluoroscopic and operative time were compared with unpaired Student t-test and pooled data of revision rate and complications were compared with chi-square analysis with an alpha set at 0.05. The rate of complications using conventional fluoroscopy was 11.3% (26/230) compared to three-dimensional navigation (6.7% (40/597), X2 (DF: 1, N = 827) = 4.79, p = .028.) which translated to a higher rate of revision surgeries in the conventional fluoroscopy group (10.9% vs. 0.8%) X2 (DF: 1, N = 827) = 47.8, p ≤.001. Average fluoroscopic time was lower for studies using three-dimensional navigation (28.8 ± 14.3 s, n = 71) compared to conventional fluoroscopy (57.8 ± 4.2 s, n = 38, p ≤.001). Three-dimensional navigation during minimally invasive pelvis and acetabular fracture fixation may have some benefits. Level of evidence: IV.
- 8 August 2023
- Published by SAGE Publications in Journal of Orthopaedics, Trauma and Rehabilitation
- Vol. 31 (1) , 60-76
Open AccessThe use of three-dimensional navigation and advanced intraoperative imaging in minimally invasive pelvic and acetabular fracture fixation: A systematic review
Pelvic and acetabular fractures are challenging injuries to treat. This review evaluates three-dimensional intraoperative imaging and navigation-guided percutaneous SI, trans-iliac, trans-sacral, and acetabular screw placement versus conventional methods performed with C-arm imaging. A systematic search of MEDLINE, Embase, and Cochrane was performed. Two reviewers independently extracted data into a collaborative data form designed a priori and piloted prior to its use. Descriptive statistics are presented where applicable. Summary statistics analysis was presented based on the fracture type. Continuous data such as fluoroscopic and operative time were compared with unpaired Student t-test and pooled data of revision rate and complications were compared with chi-square analysis with an alpha set at 0.05. The rate of complications using conventional fluoroscopy was 11.3% (26/230) compared to three-dimensional navigation (6.7% (40/597), X2 (DF: 1, N = 827) = 4.79, p = .028.) which translated to a higher rate of revision surgeries in the conventional fluoroscopy group (10.9% vs. 0.8%) X2 (DF: 1, N = 827) = 47.8, p ≤.001. Average fluoroscopic time was lower for studies using three-dimensional navigation (28.8 ± 14.3 s, n = 71) compared to conventional fluoroscopy (57.8 ± 4.2 s, n = 38, p ≤.001). Three-dimensional navigation during minimally invasive pelvis and acetabular fracture fixation may have some benefits. Level of evidence: IV.