Alexander Ian Wright
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Alexander Ian Wright has a total of 68 co-authors. Here are the top co-authors by number of shared publications:
Darren Treanor
Section of Pathology and Tumour Biology, Leeds Institute of Cancer and Pathology, University of Leeds, Leeds LS9 7TF, UK
4 shared publications- Darren Treanor
Leeds Teaching Hospitals NHS Trust, Leeds, UK
4 shared publications Darren E. Treanor
Section of Pathology and Data Analytics, Leeds Institute of Medical Research, University of Leeds, Leeds, UK
3 shared publications- Gordon G. A. Hutchins
Section of Pathology and Tumour Biology, Leeds Institute of Cancer and Pathology, University of Leeds, Leeds, UK
3 shared publications Daljeet Bansal
National Pathology Imaging Cooperative Leeds Teaching Hospitals NHS Trust Leeds UK
2 shared publicationsDanny Kaye
National Pathology Imaging Cooperative Leeds Teaching Hospitals NHS Trust Leeds UK
2 shared publications
Latest Publications
- 2 July 2026
- Published by Springer Nature
- p. 87-90
MIDOG 2025: Mitotic Figure Detection with Attention-Guided False Positive Correction
- 2 July 2026
- Published by Springer Nature
- p. 87-90
MIDOG 2025: Mitotic Figure Detection with Attention-Guided False Positive Correction
- Open Access
- 10 July 2024
- Published by Wiley in The Journal of Pathology
- Vol. 264 (1) , 80-89
Development of a multi‐scanner facility for data acquisition for digital pathology artificial intelligence
Whole slide imaging (WSI) of pathology glass slides using high‐resolution scanners has enabled the large‐scale application of artificial intelligence (AI) in pathology, to support the detection and diagnosis of disease, potentially increasing efficiency and accuracy in tissue diagnosis. Despite the promise of AI, it has limitations. ‘Brittleness’ or sensitivity to variation in inputs necessitates that large amounts of data are used for training. AI is often trained on data from different scanners but not usually by replicating the same slide across scanners. The utilisation of multiple WSI instruments to produce digital replicas of the same slides will make more comprehensive datasets and may improve the robustness and generalisability of AI algorithms as well as reduce the overall data requirements of AI training. To this end, the National Pathology Imaging Cooperative (NPIC) has built the AI FORGE (Facilitating Opportunities for Robust Generalisable data Emulation), a unique multi‐scanner facility embedded in a clinical site in the NHS to (1) compare scanner performance, (2) replicate digital pathology image datasets across WSI systems, and (3) support the evaluation of clinical AI algorithms. The NPIC AI FORGE currently comprises 15 scanners from nine manufacturers. It can generate approximately 4,000 WSI images per day (approximately 7 TB of image data). This paper describes the process followed to plan and build such a facility. © 2024 The Author(s). The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.
- 10 July 2024
- Published by Wiley in The Journal of Pathology
- Vol. 264 (1) , 80-89
Open AccessDevelopment of a multi‐scanner facility for data acquisition for digital pathology artificial intelligence
Whole slide imaging (WSI) of pathology glass slides using high‐resolution scanners has enabled the large‐scale application of artificial intelligence (AI) in pathology, to support the detection and diagnosis of disease, potentially increasing efficiency and accuracy in tissue diagnosis. Despite the promise of AI, it has limitations. ‘Brittleness’ or sensitivity to variation in inputs necessitates that large amounts of data are used for training. AI is often trained on data from different scanners but not usually by replicating the same slide across scanners. The utilisation of multiple WSI instruments to produce digital replicas of the same slides will make more comprehensive datasets and may improve the robustness and generalisability of AI algorithms as well as reduce the overall data requirements of AI training. To this end, the National Pathology Imaging Cooperative (NPIC) has built the AI FORGE (Facilitating Opportunities for Robust Generalisable data Emulation), a unique multi‐scanner facility embedded in a clinical site in the NHS to (1) compare scanner performance, (2) replicate digital pathology image datasets across WSI systems, and (3) support the evaluation of clinical AI algorithms. The NPIC AI FORGE currently comprises 15 scanners from nine manufacturers. It can generate approximately 4,000 WSI images per day (approximately 7 TB of image data). This paper describes the process followed to plan and build such a facility. © 2024 The Author(s). The Journal of Pathology published by John Wiley & Sons Ltd on behalf of The Pathological Society of Great Britain and Ireland.
- Open Access
Liver-Quant: Feature-Based Image Analysis Toolkit for Automatic Quantification of Metabolic Dysfunction-Associated Steatotic Liver Disease
Introduction: The histological assessment of liver biopsies by pathologists serves as the gold standard for diagnosing metabolic dysfunction-associated steatotic liver disease (MASLD) and staging disease progression. Various machine learning and image analysis tools have been reported to automate the quantification of fatty liver and enhance patient risk stratification. However, the current software is either not open-source or not directly applicable to the whole slide images (WSIs). Methods: In this paper, we introduce “ Liver-Quant ,” an open-source Python package designed for quantifying fat and fibrosis in liver WSIs. Employing colour and morphological features, Liver-Quant measures the Steatosis Proportionate Area (SPA) and Collagen Proportionate Area (CPA). The method’s accuracy and robustness were evaluated using an internal dataset of 424 WSIs from adult patients collected retrospectively from the archives at Leeds Teaching Hospitals NHS Trust between 2016 and 2022 and an external public dataset of 109 WSIs. For each slide, semi-quantitative scores were automatically extracted from free-text pathological reports. Furthermore, we investigated the impact of three different staining dyes including Van Gieson (VG), Picro Sirius Red (PSR), and Masson’s Trichrome (MTC) on fibrosis quantification. Results: The Spearman rank coefficient (ρ) was calculated to assess the correlation between the computed SPA/CPA values and the semi-quantitative pathologist scores. For steatosis quantification, we observed a substantial correlation (ρ=0.92), while fibrosis quantification exhibited a moderate correlation with human scores (ρ=0.51). To assess stain variation on CPA measurement, we collected N=18 cases and applied the three stains. Employing stain normalisation, an excellent agreement was observed in CPA measurements among the three stains using Bland-Altman plots. However, without stain normalisation, PSR emerged as the most effective dye due to its enhanced contrast in the Hue channel, displaying a strong correlation with human scores (ρ=0.9), followed by VG (ρ=0.8) and MTC (ρ=0.59). Additionally, we explored the impact of the apparent magnification on SPA and CPA. High resolution images collected at 0.25 microns per pixel (MPP) [apparent magnification = 40x] or 0.50 MPP [apparent magnification = 20x] were found to be essential for accurate SPA measurement, whereas for CPA measurement, low resolution images collected at 10 MPP [apparent magnification = 1x] were sufficient. Conclusion: The Liver-Quant package offers an open-source solution for rapid and precise liver quantification in WSIs applicable to multiple histological stains.
Open AccessLiver-Quant: Feature-Based Image Analysis Toolkit for Automatic Quantification of Metabolic Dysfunction-Associated Steatotic Liver Disease
Introduction: The histological assessment of liver biopsies by pathologists serves as the gold standard for diagnosing metabolic dysfunction-associated steatotic liver disease (MASLD) and staging disease progression. Various machine learning and image analysis tools have been reported to automate the quantification of fatty liver and enhance patient risk stratification. However, the current software is either not open-source or not directly applicable to the whole slide images (WSIs). Methods: In this paper, we introduce “ Liver-Quant ,” an open-source Python package designed for quantifying fat and fibrosis in liver WSIs. Employing colour and morphological features, Liver-Quant measures the Steatosis Proportionate Area (SPA) and Collagen Proportionate Area (CPA). The method’s accuracy and robustness were evaluated using an internal dataset of 424 WSIs from adult patients collected retrospectively from the archives at Leeds Teaching Hospitals NHS Trust between 2016 and 2022 and an external public dataset of 109 WSIs. For each slide, semi-quantitative scores were automatically extracted from free-text pathological reports. Furthermore, we investigated the impact of three different staining dyes including Van Gieson (VG), Picro Sirius Red (PSR), and Masson’s Trichrome (MTC) on fibrosis quantification. Results: The Spearman rank coefficient (ρ) was calculated to assess the correlation between the computed SPA/CPA values and the semi-quantitative pathologist scores. For steatosis quantification, we observed a substantial correlation (ρ=0.92), while fibrosis quantification exhibited a moderate correlation with human scores (ρ=0.51). To assess stain variation on CPA measurement, we collected N=18 cases and applied the three stains. Employing stain normalisation, an excellent agreement was observed in CPA measurements among the three stains using Bland-Altman plots. However, without stain normalisation, PSR emerged as the most effective dye due to its enhanced contrast in the Hue channel, displaying a strong correlation with human scores (ρ=0.9), followed by VG (ρ=0.8) and MTC (ρ=0.59). Additionally, we explored the impact of the apparent magnification on SPA and CPA. High resolution images collected at 0.25 microns per pixel (MPP) [apparent magnification = 40x] or 0.50 MPP [apparent magnification = 20x] were found to be essential for accurate SPA measurement, whereas for CPA measurement, low resolution images collected at 10 MPP [apparent magnification = 1x] were sufficient. Conclusion: The Liver-Quant package offers an open-source solution for rapid and precise liver quantification in WSIs applicable to multiple histological stains.
- Open Access
Development of a multi-scanner facility for data acquisition for digital pathology artificial intelligence
Whole slide imaging (WSI) of pathology glass slides with high-resolution scanners has enabled the large-scale application of artificial intelligence (AI) in pathology, to support the detection and diagnosis of disease, potentially increasing efficiency and accuracy in tissue diagnosis. Despite the promise of AI, it has limitations. “Brittleness” or sensitivity to variation in inputs necessitates that large amounts of data are used for training. AI is often trained on data from different scanners but not usually by replicating the same slide across scanners. The utilisation of multiple WSI instruments to produce digital replicas of the same glass slides will make more comprehensive datasets and may improve the robustness and generalisability of AI algorithms as well as reduce the overall data requirements of AI training. To this end, the National Pathology Imagine Cooperative (NPIC) has built the AI FORGE ( F acilitating O pportunities for R obust G eneralisable data E mulation), a unique multi-scanner facility embedded in a clinical site in the NHS to (a) compare scanner performance and (b) replicate digital pathology image datasets across WSI systems. The NPIC AI FORGE currently comprises 15 scanners from 9 manufacturers. It can generate approximately 4000 WSI images per day (approximately 7Tb of image data). This paper describes the process followed to plan and build such a facility.
Open AccessDevelopment of a multi-scanner facility for data acquisition for digital pathology artificial intelligence
Whole slide imaging (WSI) of pathology glass slides with high-resolution scanners has enabled the large-scale application of artificial intelligence (AI) in pathology, to support the detection and diagnosis of disease, potentially increasing efficiency and accuracy in tissue diagnosis. Despite the promise of AI, it has limitations. “Brittleness” or sensitivity to variation in inputs necessitates that large amounts of data are used for training. AI is often trained on data from different scanners but not usually by replicating the same slide across scanners. The utilisation of multiple WSI instruments to produce digital replicas of the same glass slides will make more comprehensive datasets and may improve the robustness and generalisability of AI algorithms as well as reduce the overall data requirements of AI training. To this end, the National Pathology Imagine Cooperative (NPIC) has built the AI FORGE ( F acilitating O pportunities for R obust G eneralisable data E mulation), a unique multi-scanner facility embedded in a clinical site in the NHS to (a) compare scanner performance and (b) replicate digital pathology image datasets across WSI systems. The NPIC AI FORGE currently comprises 15 scanners from 9 manufacturers. It can generate approximately 4000 WSI images per day (approximately 7Tb of image data). This paper describes the process followed to plan and build such a facility.
- Open Access
- 18 February 2022
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 109 (3) , 291-297
Increasing frequency of gene copy number aberrations is associated with immunosuppression and predicts poor prognosis in gastric adenocarcinoma
Patients with Epstein–Barr virus-positive gastric cancers or those with microsatellite instability appear to have a favourable prognosis. However, the prognostic value of the chromosomal status (chromosome-stable (CS) versus chromosomal instable (CIN)) remains unclear in gastric cancer. Gene copy number aberrations (CNAs) were determined in 16 CIN-associated genes in a retrospective study including test and validation cohorts of patients with gastric cancer. Patients were stratified into CS (no CNA), CINlow (1–2 CNAs) or CINhigh (3 or more CNAs). The relationship between chromosomal status, clinicopathological variables, and overall survival (OS) was analysed. The relationship between chromosomal status, p53 expression, and tumour infiltrating immune cells was also assessed and validated externally. The test and validation cohorts included 206 and 748 patients, respectively. CINlow and CINhigh were seen in 35.0 and 15.0 per cent of patients, respectively, in the test cohort, and 48.5 and 20.7 per cent in the validation cohort. Patients with CINhigh gastric cancer had the poorest OS in the test and validation cohorts. In multivariable analysis, CINlow, CINhigh and pTNM stage III–IV (P < 0.001) were independently associated with poor OS. CIN was associated with high p53 expression and low immune cell infiltration. CIN may be a potential new prognostic biomarker independent of pTNM stage in gastric cancer. Patients with gastric cancer demonstrating CIN appear to be immunosuppressed, which might represent one of the underlying mechanisms explaining the poor survival and may help guide future therapeutic decisions.
- 18 February 2022
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 109 (3) , 291-297
Open AccessIncreasing frequency of gene copy number aberrations is associated with immunosuppression and predicts poor prognosis in gastric adenocarcinoma
Patients with Epstein–Barr virus-positive gastric cancers or those with microsatellite instability appear to have a favourable prognosis. However, the prognostic value of the chromosomal status (chromosome-stable (CS) versus chromosomal instable (CIN)) remains unclear in gastric cancer. Gene copy number aberrations (CNAs) were determined in 16 CIN-associated genes in a retrospective study including test and validation cohorts of patients with gastric cancer. Patients were stratified into CS (no CNA), CINlow (1–2 CNAs) or CINhigh (3 or more CNAs). The relationship between chromosomal status, clinicopathological variables, and overall survival (OS) was analysed. The relationship between chromosomal status, p53 expression, and tumour infiltrating immune cells was also assessed and validated externally. The test and validation cohorts included 206 and 748 patients, respectively. CINlow and CINhigh were seen in 35.0 and 15.0 per cent of patients, respectively, in the test cohort, and 48.5 and 20.7 per cent in the validation cohort. Patients with CINhigh gastric cancer had the poorest OS in the test and validation cohorts. In multivariable analysis, CINlow, CINhigh and pTNM stage III–IV (P < 0.001) were independently associated with poor OS. CIN was associated with high p53 expression and low immune cell infiltration. CIN may be a potential new prognostic biomarker independent of pTNM stage in gastric cancer. Patients with gastric cancer demonstrating CIN appear to be immunosuppressed, which might represent one of the underlying mechanisms explaining the poor survival and may help guide future therapeutic decisions.
- Open Access
- 20 January 2021
- Published by Springer Nature in Medical Science Educator
- Vol. 31 (2) , 549-556
Development of a Remote Online Collaborative Medical School Pathology Curriculum with Clinical Correlations, across Several International Sites, through the Covid-19 Pandemic
Introduction: Due to the Covid-19 social distancing restrictions, in March 2020, Weill Cornell Medicine-Qatar decided to replace students’ clinical instruction with novel online electives. Hence, we implemented an innovative online and remote pathology curriculum, anchored on virtual microscopy and Zoom videoconferencing: ideal tools to support online teaching.Objective: To assess a new curriculum implementation at Weill Cornell Medicine-Qatar.Materials and Methods: This for-credit, 2-week elective included 6 synchronous Zoom sessions where complex clinicopathological cases were discussed in small groups. We used open access digital microscopy slides from the University of Leeds’ Virtual Pathology Library (http://www.virtualpathology.leeds.ac.uk/slides/library/). Students independently prepared for these sessions by reviewing cases, slides, readings, and questions in advance (asynchronous self-directed learning anchored on a flipped classroom model), and wrote a final review of a case. An assessment and feedback were given to each student.Results: Four elective iterations were offered to a total of 29 students, with learners and faculty spread over 4 countries. During the Zoom sessions, students controlled the digital slides and offered their own diagnoses, followed by group discussions to strengthen autonomy and confidence. We surveyed learners about the elective’s performance (program evaluation). Students conveyed high levels of satisfaction about the elective’s overall quality, their pathology learning and online interactions, with minimal challenges related to the remote nature of the course.Discussion and Conclusions: Technological innovations mitigate sudden disruptions in medical education. A remote curriculum allows instructionat any distance, at any time, from anywhere,enhancing educational exchanges, flexibility and globalization in medical education.
- 20 January 2021
- Published by Springer Nature in Medical Science Educator
- Vol. 31 (2) , 549-556
Open AccessDevelopment of a Remote Online Collaborative Medical School Pathology Curriculum with Clinical Correlations, across Several International Sites, through the Covid-19 Pandemic
Introduction: Due to the Covid-19 social distancing restrictions, in March 2020, Weill Cornell Medicine-Qatar decided to replace students’ clinical instruction with novel online electives. Hence, we implemented an innovative online and remote pathology curriculum, anchored on virtual microscopy and Zoom videoconferencing: ideal tools to support online teaching.Objective: To assess a new curriculum implementation at Weill Cornell Medicine-Qatar.Materials and Methods: This for-credit, 2-week elective included 6 synchronous Zoom sessions where complex clinicopathological cases were discussed in small groups. We used open access digital microscopy slides from the University of Leeds’ Virtual Pathology Library (http://www.virtualpathology.leeds.ac.uk/slides/library/). Students independently prepared for these sessions by reviewing cases, slides, readings, and questions in advance (asynchronous self-directed learning anchored on a flipped classroom model), and wrote a final review of a case. An assessment and feedback were given to each student.Results: Four elective iterations were offered to a total of 29 students, with learners and faculty spread over 4 countries. During the Zoom sessions, students controlled the digital slides and offered their own diagnoses, followed by group discussions to strengthen autonomy and confidence. We surveyed learners about the elective’s performance (program evaluation). Students conveyed high levels of satisfaction about the elective’s overall quality, their pathology learning and online interactions, with minimal challenges related to the remote nature of the course.Discussion and Conclusions: Technological innovations mitigate sudden disruptions in medical education. A remote curriculum allows instructionat any distance, at any time, from anywhere,enhancing educational exchanges, flexibility and globalization in medical education.
- 21 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (2) , 307-314
The Effect of Quality Control on Accuracy of Digital Pathology Image Analysis
Digital slide images produced from routine diagnostic histopathological preparations suffer from variation arising at every step of the processing pipeline. Typically, pathologists compensate for such variation using expert knowledge and experience, which is difficult to replicate in automated solutions. The extent to which inconsistencies affect image analysis is explored in this work, examining in detail, the results from a previously published algorithm automating the generation of tumor:stroma ratio (TSR) in colorectal clinical trial datasets. One dataset consisting of 2,211 cases and 106,268 expert-labelled images is used to identify quality issues, by visually inspecting cases where algorithm-pathologist agreement is lowest. Twelve categories are identified and used to analyze pathologist-algorithm agreement in relation to these categories. Of the 2,211 cases, 701 were found to be free from any image quality issues. Algorithm performance was then assessed, comparing pathologist agreement with image quality classification. It was found that agreement was lowest on poorly differentiated tissue, with a mean TSR difference of 0.25 (sd=0.24). Removing images that contained quality issues increased accuracy from 80% to 83%, at the expense of reducing the dataset to 33,736 images (32%). Training the algorithm on the optimized dataset, prior to testing on all images saw a decrease in accuracy of 4%, indicating that the optimized dataset did not contain enough variation to generate a fully representative model. The results provide an in-depth perspective on image quality, highlighting the importance of the effects on downstream image analysis.
- 21 December 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (2) , 307-314
The Effect of Quality Control on Accuracy of Digital Pathology Image Analysis
Digital slide images produced from routine diagnostic histopathological preparations suffer from variation arising at every step of the processing pipeline. Typically, pathologists compensate for such variation using expert knowledge and experience, which is difficult to replicate in automated solutions. The extent to which inconsistencies affect image analysis is explored in this work, examining in detail, the results from a previously published algorithm automating the generation of tumor:stroma ratio (TSR) in colorectal clinical trial datasets. One dataset consisting of 2,211 cases and 106,268 expert-labelled images is used to identify quality issues, by visually inspecting cases where algorithm-pathologist agreement is lowest. Twelve categories are identified and used to analyze pathologist-algorithm agreement in relation to these categories. Of the 2,211 cases, 701 were found to be free from any image quality issues. Algorithm performance was then assessed, comparing pathologist agreement with image quality classification. It was found that agreement was lowest on poorly differentiated tissue, with a mean TSR difference of 0.25 (sd=0.24). Removing images that contained quality issues increased accuracy from 80% to 83%, at the expense of reducing the dataset to 33,736 images (32%). Training the algorithm on the optimized dataset, prior to testing on all images saw a decrease in accuracy of 4%, indicating that the optimized dataset did not contain enough variation to generate a fully representative model. The results provide an in-depth perspective on image quality, highlighting the importance of the effects on downstream image analysis.
- Open Access
- 1 January 2020
- Published by Elsevier in Journal of Pathology Informatics
- Vol. 11 (1) , 17
A Point-of-Use Quality Assurance Tool for Digital Pathology Remote Working
- 1 January 2020
- Published by Elsevier in Journal of Pathology Informatics
- Vol. 11 (1) , 17
Open AccessA Point-of-Use Quality Assurance Tool for Digital Pathology Remote Working
- Open Access
- 25 July 2016
- Published by Elsevier in Procedia Computer Science
- Vol. 90, 125-131
Incorporating Local and Global Context for Better Automated Analysis of Colorectal Cancer on Digital Pathology Slides
- 25 July 2016
- Published by Elsevier in Procedia Computer Science
- Vol. 90, 125-131
Open AccessIncorporating Local and Global Context for Better Automated Analysis of Colorectal Cancer on Digital Pathology Slides
- Open Access
- 16 December 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-8
The prognostic significance of tumour-stroma ratio in endometrial carcinoma
High tumour stromal content has been found to predict adverse clinical outcome in a range of epithelial tumours. The aim of this study was to assess the prognostic significance of tumour-stroma ratio (TSR) in endometrial adenocarcinomas and investigate its relationship with other clinicopathological parameters. Clinicopathological and 5-year follow-up data were obtained for a retrospective series of endometrial adenocarcinoma patients (n = 400). TSR was measured using a morphometric approach (point counting) on digitised histologic hysterectomy specimens. Inter-observer agreement was determined using Cohen’s Kappa statistic. TSR cut-offs were optimised using log-rank functions and prognostic significance of TSR on overall survival (OS) and disease-free survival (DFS) were determined using Cox Proportional Hazards regression analysis and Kaplan-Meier curves generated. Associations of TSR with other clinicopathological parameters were determined using non-parametric tests followed by Holm-Bonferroni correction for multiple comparisons. TSR as a continuous variable associated with worse OS (P = 0.034) in univariable Cox-regression analysis. Using the optimal cut-off TSR value of 1.3, TSR-high (i.e. low stroma) was associated with worse OS (HR = 2.51; 95 % CI = 1.22–5.12; P = 0.021) and DFS (HR = 2.19; 95 % CI = 1.15–4.17; P = 0.017) in univariable analysis. However, TSR did not have independent prognostic significance in multivariable analysis, when adjusted for known prognostic variables. A highly significant association was found between TSR and tumour grade (P < 0.001) and lymphovascular space invasion (P < 0.001), both of which had independent prognostic significance in this study population. Low tumour stromal content associates with both poor outcome and with other adverse prognostic indicators in endometrial cancer, although it is not independently prognostic. These findings contrast with studies on many - although not all - cancers and suggest that the biology of tumour-stroma interactions may differ amongst cancer types.
- 16 December 2015
- Published by Springer Nature in BMC Cancer
- Vol. 15 (1) , 1-8
Open AccessThe prognostic significance of tumour-stroma ratio in endometrial carcinoma
High tumour stromal content has been found to predict adverse clinical outcome in a range of epithelial tumours. The aim of this study was to assess the prognostic significance of tumour-stroma ratio (TSR) in endometrial adenocarcinomas and investigate its relationship with other clinicopathological parameters. Clinicopathological and 5-year follow-up data were obtained for a retrospective series of endometrial adenocarcinoma patients (n = 400). TSR was measured using a morphometric approach (point counting) on digitised histologic hysterectomy specimens. Inter-observer agreement was determined using Cohen’s Kappa statistic. TSR cut-offs were optimised using log-rank functions and prognostic significance of TSR on overall survival (OS) and disease-free survival (DFS) were determined using Cox Proportional Hazards regression analysis and Kaplan-Meier curves generated. Associations of TSR with other clinicopathological parameters were determined using non-parametric tests followed by Holm-Bonferroni correction for multiple comparisons. TSR as a continuous variable associated with worse OS (P = 0.034) in univariable Cox-regression analysis. Using the optimal cut-off TSR value of 1.3, TSR-high (i.e. low stroma) was associated with worse OS (HR = 2.51; 95 % CI = 1.22–5.12; P = 0.021) and DFS (HR = 2.19; 95 % CI = 1.15–4.17; P = 0.017) in univariable analysis. However, TSR did not have independent prognostic significance in multivariable analysis, when adjusted for known prognostic variables. A highly significant association was found between TSR and tumour grade (P < 0.001) and lymphovascular space invasion (P < 0.001), both of which had independent prognostic significance in this study population. Low tumour stromal content associates with both poor outcome and with other adverse prognostic indicators in endometrial cancer, although it is not independently prognostic. These findings contrast with studies on many - although not all - cancers and suggest that the biology of tumour-stroma interactions may differ amongst cancer types.