Thomas Y. Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Thomas Y. Wu has a total of 94 co-authors. Here are the top co-authors by number of shared publications:
S. W. Chua
National Metrology Centre, A*STAR, 1 Science Park Dr, 118221, Singapore
6 shared publications- Patrice Salzenstein
Centre National de la Recherche Scientifique (CNRS), Franche-Comté Electronique Optique Sciences et Technologies (FEMTO-ST) Institute, Université Marie et Louis Pasteur (UMLP), 15B Avenue des Montboucons, F-25030 Besançon, France
5 shared publications Asaad Kenbar
3 shared publicationsD.C. Munson
Department of Electrical and Computer Engineering, Univeristy of Illinois at Urbana-Champaign, Urbana, IL 61801, USA
3 shared publicationsA.R. Leyman
2 shared publicationsFang-Hsin Lin
Center for Measurement Standards, Industrial Technology Research Institute (CMS/ITRI), Hsinchu, Taiwan
2 shared publications
Latest Publications
- Open Access
The Critical Role of International Comparisons in Global Metrology System: An Overview
International comparisons play a critical role in ensuring precision, accuracy, consistency, and trust in the global metrology system. The Comité International des Poids et Mesures (CIPM) established the Mutual Recognition Arrangement (MRA) in 1999 to facilitate global trade. This paper gives an overview of the critical role of international comparisons to National Metrology Institutes (NMIs), industrial calibration laboratories, and research laboratories in fostering global measurement equivalence and the CIPM MRA. NMIs rely on Key and Supplementary Comparisons to ensure the mutual recognition of calibration and reference material certificates, vital for global trade and regulatory compliance. Industrial calibration laboratories participate in inter-laboratory or international comparisons to validate their calibration and measurement capability (CMC) and balance their risk management. Research laboratories push the frontiers of measurement science and validate their measurement result via international comparisons. Through some examples of comparisons, the paper illustrates how measurement result discrepancies uncovered in comparisons drive technical improvements, uncertainty component identification, and measurement technique refinement. International comparisons enhance scientific credibility, build public trust, support industrial innovation, and drive evolution in measurement science. As technological demands grow, fostering broader participation in international comparisons by various metrology and research laboratories remains crucial to maintain a robust and reliable global metrology system.
Open AccessThe Critical Role of International Comparisons in Global Metrology System: An Overview
International comparisons play a critical role in ensuring precision, accuracy, consistency, and trust in the global metrology system. The Comité International des Poids et Mesures (CIPM) established the Mutual Recognition Arrangement (MRA) in 1999 to facilitate global trade. This paper gives an overview of the critical role of international comparisons to National Metrology Institutes (NMIs), industrial calibration laboratories, and research laboratories in fostering global measurement equivalence and the CIPM MRA. NMIs rely on Key and Supplementary Comparisons to ensure the mutual recognition of calibration and reference material certificates, vital for global trade and regulatory compliance. Industrial calibration laboratories participate in inter-laboratory or international comparisons to validate their calibration and measurement capability (CMC) and balance their risk management. Research laboratories push the frontiers of measurement science and validate their measurement result via international comparisons. Through some examples of comparisons, the paper illustrates how measurement result discrepancies uncovered in comparisons drive technical improvements, uncertainty component identification, and measurement technique refinement. International comparisons enhance scientific credibility, build public trust, support industrial innovation, and drive evolution in measurement science. As technological demands grow, fostering broader participation in international comparisons by various metrology and research laboratories remains crucial to maintain a robust and reliable global metrology system.
- Open Access
- 18 June 2024
- Published by SPIE-Intl Soc Optical Eng
- p. 52
Uncertainty on Brillouin frequency on bulk polymethyl methacrylate for acoustic waves velocities
Access SPIE's growing collection of conference proceeding papers from around the globe. Browse by the latest conferences or optics-based technology.
- 18 June 2024
- Published by SPIE-Intl Soc Optical Eng
- p. 52
Open AccessUncertainty on Brillouin frequency on bulk polymethyl methacrylate for acoustic waves velocities
Access SPIE's growing collection of conference proceeding papers from around the globe. Browse by the latest conferences or optics-based technology.
- 27 November 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12760, 23-83
Uncertainty on Brillouin scattering measurements on bulk materials using a power laser
Through this paper, we describe the method leading to the estimation of the uncertainty. We aim to give an estimation of the uncertainty on the frequency peak by Brillouin Scattering Stimulation. It corresponds to the speed of phonons inside a material excited by a 532nm wavelength laser. The guideline follows the Guide to the Expression of Uncertainty in Measurement and its estimation is of 0.26% on the Brillouin frequency peak at 15.70 GHz for polymethyl methacrylate (PMMA).
- 27 November 2023
- Published by SPIE-Intl Soc Optical Eng
- Vol. 12760, 23-83
Uncertainty on Brillouin scattering measurements on bulk materials using a power laser
Through this paper, we describe the method leading to the estimation of the uncertainty. We aim to give an estimation of the uncertainty on the frequency peak by Brillouin Scattering Stimulation. It corresponds to the speed of phonons inside a material excited by a 532nm wavelength laser. The guideline follows the Guide to the Expression of Uncertainty in Measurement and its estimation is of 0.26% on the Brillouin frequency peak at 15.70 GHz for polymethyl methacrylate (PMMA).
- 22 July 2023
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 7 (4) , 441-454
Investigation of the Artificial Saliva and Saline Droplet Size Measurement Accuracy for COVID-19 Infection Control
- 22 July 2023
- Published by Springer Nature in Aerosol Science and Engineering
- Vol. 7 (4) , 441-454
Investigation of the Artificial Saliva and Saline Droplet Size Measurement Accuracy for COVID-19 Infection Control
- Open Access
- 15 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1429
Uncertainty Estimation for the Brillouin Frequency Shift Measurement Using a Scanning Tandem Fabry–Pérot Interferometer
The expanded uncertainty of the measured Brillouin scattering shift frequencies is essential in assessing the measurements of parameters of various materials. We describe the general operation principles of a Brillouin light scattering (BLS) spectrometer with a high-power laser and a scanning tandem Fabry–Pérot interferometer (TFPI) for material characterization. Various uncertainty components have been analyzed for the BLS spectrometer following the Guide to the Expression of Uncertainty in Measurement (GUM). The expanded relative uncertainty in the measured Brillouin frequency shift of 15.70 GHz for polymethyl methacrylate (PMMA) was estimated to be 0.26%. The calculated Brillouin frequency shift (based on material properties of PMMA) was determined to be 15.44 GHz with expanded relative uncertainty of 2.13%. It was shown that the measured and calculated Brillouin frequency shifts for PMMA agree within their expanded uncertainties. The TFPI-based BLS spectrometer can be used to measure the longitudinal modulus of materials with an expanded uncertainty of 1.9%, which is smaller than that of the ultrasonic velocity-based method (estimated to be 2.9%).
- 15 July 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (7) , 1429
Open AccessUncertainty Estimation for the Brillouin Frequency Shift Measurement Using a Scanning Tandem Fabry–Pérot Interferometer
The expanded uncertainty of the measured Brillouin scattering shift frequencies is essential in assessing the measurements of parameters of various materials. We describe the general operation principles of a Brillouin light scattering (BLS) spectrometer with a high-power laser and a scanning tandem Fabry–Pérot interferometer (TFPI) for material characterization. Various uncertainty components have been analyzed for the BLS spectrometer following the Guide to the Expression of Uncertainty in Measurement (GUM). The expanded relative uncertainty in the measured Brillouin frequency shift of 15.70 GHz for polymethyl methacrylate (PMMA) was estimated to be 0.26%. The calculated Brillouin frequency shift (based on material properties of PMMA) was determined to be 15.44 GHz with expanded relative uncertainty of 2.13%. It was shown that the measured and calculated Brillouin frequency shifts for PMMA agree within their expanded uncertainties. The TFPI-based BLS spectrometer can be used to measure the longitudinal modulus of materials with an expanded uncertainty of 1.9%, which is smaller than that of the ultrasonic velocity-based method (estimated to be 2.9%).
- 1 January 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (1A)
Key comparison COOMET.QM-K120 "Carbon dioxide in air at urban level (480–800) μmol/mol"
Main text: This article presents the report on the COOMET key comparison COOMET.QM-K120, which is designed as linking to the appropriate CCQM comparison - CCQM-K120.b "Carbon dioxide in air at urban level (480–800) μmol/mol" carried out in 2016-2018. CCQM-K120.b is considered as a Track A comparison and tests core skills and competencies required in gravimetric preparation, analytical certification and purity analysis. Participants successful in CCQM-K120.b and the linked COOMET.QM-K120 comparison may use their results in the flexible scheme and underpin claims for all core mixtures in accordance with the GAWG strategy document. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- 1 January 2023
- Published by IOP Publishing in Metrologia
- Vol. 60 (1A)
Key comparison COOMET.QM-K120 "Carbon dioxide in air at urban level (480–800) μmol/mol"
Main text: This article presents the report on the COOMET key comparison COOMET.QM-K120, which is designed as linking to the appropriate CCQM comparison - CCQM-K120.b "Carbon dioxide in air at urban level (480–800) μmol/mol" carried out in 2016-2018. CCQM-K120.b is considered as a Track A comparison and tests core skills and competencies required in gravimetric preparation, analytical certification and purity analysis. Participants successful in CCQM-K120.b and the linked COOMET.QM-K120 comparison may use their results in the flexible scheme and underpin claims for all core mixtures in accordance with the GAWG strategy document. To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database https://www.bipm.org/kcdb/. The final report has been peer-reviewed and approved for publication by the CCQM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
- Open Access
- 19 August 2022
- Published by Elsevier in Measurement
- Vol. 201
Evaluation of aerosol-spectrometer based PM2.5 and PM10 mass concentration measurement using ambient-like model aerosols in the laboratory
- 19 August 2022
- Published by Elsevier in Measurement
- Vol. 201
Open AccessEvaluation of aerosol-spectrometer based PM2.5 and PM10 mass concentration measurement using ambient-like model aerosols in the laboratory
- 1 January 2022
- Published by Elsevier in Measurement
- Vol. 188
LNG mass flow measurement uncertainty reduction using calculated Young’s modulus and Poisson’s ratio for Coriolis flowmeters
- 1 January 2022
- Published by Elsevier in Measurement
- Vol. 188
LNG mass flow measurement uncertainty reduction using calculated Young’s modulus and Poisson’s ratio for Coriolis flowmeters