Alexander S. Parker
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Alexander S. Parker has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Patrick R. Unwin
Department of Chemistry, University of Warwick, Coventry, CV4 7AL, UK
3 shared publications Alexander T. Ashcroft
Unilever Oral Care, Quarry Road East, Bebington, Wirral CH63 3JW, UK
2 shared publicationsAndrew Joiner
Unilever Oral Care, Quarry Road East, Bebington, Wirral CH63 3JW, UK
2 shared publications- Kim McKelvey
MacDiarmid Institute for Advanced Materials and Nanotechnology and School of Chemical and Physical Sciences, Victoria University of Wellington, Wellington, New Zealand
2 shared publications Massimo Peruffo
Unilever Oral Care, Quarry Road East, Bebington, Wirral CH63 3JW, UK
2 shared publicationsMel Carvell
Unilever Oral Care, Quarry Road East, Bebington, Wirral CH63 3JW, UK
2 shared publications
Latest Publications
- Open Access
Investigation into the Release of Respiratory Aerosols by Brass Instruments and Mitigation Measures with Respect to Covid-19
There are a number of recent studies detailing the transmission of SARS-CoV-2 (Covid-19) via both Droplet and Aerosol airborne particle routes of infection. Because of this, it is necessary to understand the release of different sized particles in activities such as playing brass instruments in order for an analysis of risk to take place for such activities. In this investigation, the quantity and size of particles released by brass instruments while they are played was analysed for 7 different types of brass instrument. This was contrasted with the same individuals breathing as a comparison for more general activities as well as the effect of a mitigating polycotton barrier over the end of their instruments. To investigate the particles released, the particles were size sorted and counted with a six-channel laser particle counter. Multiple measurements were made by each individual in each condition investigated. The mean concentration exiting across all instruments measured was found to be 1.21×10 7 ±1.03×10 6 Aerosol type particles/m 3 and 1.43×10 4 ±9.01×10 2 Droplet type particles/m 3 per minute. When breathing, the mean count was 1.61×10 7 ±1.33×10 6 Aerosol type particle/m 3 and 5.45×10 3 ±1.20×10 3 Droplet type particles/m 3 . When playing with a barrier cover, the mean number of particles emitted fell to 2.60×10 6 ±2.11×10 5 Aerosol type particle/m 3 and 5.20×10 3 ±8.02×10 2 Droplet type particles/m 3 . This barrier represented an average 78.5% reduction for the number of respiratory Aerosol type particles and 63.8% reduction for Droplet type particles compared to playing an instrument without the barrier covering. It was investigated what effect playing for a more extended period of time had on the release of particles with comparisons made to singing, breathing and covering the instruments’ bell ends with a barrier cap. This showed that the mean number of Aerosol type particles produced while playing was 5.38×10 7 ±3.15×10 6 Aerosol type particles/m 3 produced and showed a significant drop in Aerosol type particle production when playing with a barrier used, with a mean average of 2.28×10 6 ±8.01×10 4 Aerosol type particles/m 3 . Both breathing and singing showed consistent numbers of Aerosol type particles produced with means of 6.59×10 7 ±7.94×10 5 Aerosol type particles/m 3 and 5.28×10 7 ±5.36×10 5 Aerosol type particles/m 3 respectively. This showed a drop in mean Aerosol type particles/m of 95.7% when using a barrier cap compared to playing without a barrier. It is concluded that, while playing a brass instrument, the propagation of respiratory Aerosols does occur and, to a smaller extent, so do Droplet size particles, but at a lower level than when the subject was breathing without an instrument. Finally, it was shown that the use of a barrier cap on the bell end of the instrument offers a significant reduction in the production of respiratory Aerosols into the immediate surroundings, which offers a possible mitigation method for playing in groups from the release of Aerosol type particles, especially in hard to ventilate spaces. Funding: This study was supported by funds from Arts Council England covering salary support for AP and KC. The cleanroom facility and particle counter were provisioned by Centre Stage Ltd. The funders did not have a role in the experimental design, data collection, analysis or decision to publish and content of the manuscript. Competing Interests: The authors have declared working for Brass Bands England, which exists to support brass bands in England and the wider UK.
Open AccessInvestigation into the Release of Respiratory Aerosols by Brass Instruments and Mitigation Measures with Respect to Covid-19
There are a number of recent studies detailing the transmission of SARS-CoV-2 (Covid-19) via both Droplet and Aerosol airborne particle routes of infection. Because of this, it is necessary to understand the release of different sized particles in activities such as playing brass instruments in order for an analysis of risk to take place for such activities. In this investigation, the quantity and size of particles released by brass instruments while they are played was analysed for 7 different types of brass instrument. This was contrasted with the same individuals breathing as a comparison for more general activities as well as the effect of a mitigating polycotton barrier over the end of their instruments. To investigate the particles released, the particles were size sorted and counted with a six-channel laser particle counter. Multiple measurements were made by each individual in each condition investigated. The mean concentration exiting across all instruments measured was found to be 1.21×10 7 ±1.03×10 6 Aerosol type particles/m 3 and 1.43×10 4 ±9.01×10 2 Droplet type particles/m 3 per minute. When breathing, the mean count was 1.61×10 7 ±1.33×10 6 Aerosol type particle/m 3 and 5.45×10 3 ±1.20×10 3 Droplet type particles/m 3 . When playing with a barrier cover, the mean number of particles emitted fell to 2.60×10 6 ±2.11×10 5 Aerosol type particle/m 3 and 5.20×10 3 ±8.02×10 2 Droplet type particles/m 3 . This barrier represented an average 78.5% reduction for the number of respiratory Aerosol type particles and 63.8% reduction for Droplet type particles compared to playing an instrument without the barrier covering. It was investigated what effect playing for a more extended period of time had on the release of particles with comparisons made to singing, breathing and covering the instruments’ bell ends with a barrier cap. This showed that the mean number of Aerosol type particles produced while playing was 5.38×10 7 ±3.15×10 6 Aerosol type particles/m 3 produced and showed a significant drop in Aerosol type particle production when playing with a barrier used, with a mean average of 2.28×10 6 ±8.01×10 4 Aerosol type particles/m 3 . Both breathing and singing showed consistent numbers of Aerosol type particles produced with means of 6.59×10 7 ±7.94×10 5 Aerosol type particles/m 3 and 5.28×10 7 ±5.36×10 5 Aerosol type particles/m 3 respectively. This showed a drop in mean Aerosol type particles/m of 95.7% when using a barrier cap compared to playing without a barrier. It is concluded that, while playing a brass instrument, the propagation of respiratory Aerosols does occur and, to a smaller extent, so do Droplet size particles, but at a lower level than when the subject was breathing without an instrument. Finally, it was shown that the use of a barrier cap on the bell end of the instrument offers a significant reduction in the production of respiratory Aerosols into the immediate surroundings, which offers a possible mitigation method for playing in groups from the release of Aerosol type particles, especially in hard to ventilate spaces. Funding: This study was supported by funds from Arts Council England covering salary support for AP and KC. The cleanroom facility and particle counter were provisioned by Centre Stage Ltd. The funders did not have a role in the experimental design, data collection, analysis or decision to publish and content of the manuscript. Competing Interests: The authors have declared working for Brass Bands England, which exists to support brass bands in England and the wider UK.
- 14 October 2016
- Published by Wiley in ChemElectroChem
- Vol. 3 (12) , 2212-2220
Electrochemical Control of Calcium Carbonate Crystallization and Dissolution in Nanopipettes
Electrochemically controlled nanopipettes are becoming increasingly versatile tools for a diverse range of sequencing, sizing, and imaging applications. Herein, the use of nanopipettes to induce and quantitatively monitor crystallization and dissolution in real time is considered, using CaCO3 in aqueous solution as an exemplar system. The bias between a quasi‐reference counter electrode in a nanopipette and one in a bulk solution is used to mix (or de‐mix) two different solutions by ion migration and drive either growth or dissolution, depending on the polarity. Furthermore, Raman spectroscopy can be applied simultaneously to identify polymorphs formed in the nanopipette. The technique is supported with a robust finite element method model that allows the extraction of time‐dependent saturation levels and mixing characteristics at the nanoscale. The technique shows great promise as a tool for rapidly screening growth additives and inhibitors, allowing eight different additives to be ranked in order of efficacy for crystal growth rate inhibition.
- 14 October 2016
- Published by Wiley in ChemElectroChem
- Vol. 3 (12) , 2212-2220
Electrochemical Control of Calcium Carbonate Crystallization and Dissolution in Nanopipettes
Electrochemically controlled nanopipettes are becoming increasingly versatile tools for a diverse range of sequencing, sizing, and imaging applications. Herein, the use of nanopipettes to induce and quantitatively monitor crystallization and dissolution in real time is considered, using CaCO3 in aqueous solution as an exemplar system. The bias between a quasi‐reference counter electrode in a nanopipette and one in a bulk solution is used to mix (or de‐mix) two different solutions by ion migration and drive either growth or dissolution, depending on the polarity. Furthermore, Raman spectroscopy can be applied simultaneously to identify polymorphs formed in the nanopipette. The technique is supported with a robust finite element method model that allows the extraction of time‐dependent saturation levels and mixing characteristics at the nanoscale. The technique shows great promise as a tool for rapidly screening growth additives and inhibitors, allowing eight different additives to be ranked in order of efficacy for crystal growth rate inhibition.
- Open Access
- 1 August 2016
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 476, 94-102
Combinatorial localized dissolution analysis: Application to acid-induced dissolution of dental enamel and the effect of surface treatments
- 1 August 2016
- Published by Elsevier in Journal of Colloid and Interface Science
- Vol. 476, 94-102
Open AccessCombinatorial localized dissolution analysis: Application to acid-induced dissolution of dental enamel and the effect of surface treatments
- 1 June 2014
- Published by Elsevier in Journal of Dentistry
- Vol. 42, S21-S29
Measurement of the efficacy of calcium silicate for the protection and repair of dental enamel
- 1 June 2014
- Published by Elsevier in Journal of Dentistry
- Vol. 42, S21-S29
Measurement of the efficacy of calcium silicate for the protection and repair of dental enamel