NFNeus Fabregas

Neus Fabregas

*This is an algorithmically generated author record based on publicly available information.

Neus Fabregas has a total of 141 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Deep brain stimulation under general anaesthesia for Parkinson's disease: A retrospective evaluation of perioperative events and anaesthetic management after switching away from conscious sedation

    by Marta Garcia‐Orellana, Felipe Maldonado, Paola Hurtado, Gabriel Pujol‐Fontrodona, Pedro Roldán, Alejandra Mosteiro, Jordi Rumià, Almudena Sánchez‐Gómez, Nicolás De Riva, Neus Fàbregas, et al.

    Background: Deep brain stimulation has become the standard of care for refractory Parkinson's disease. Neuroimaging advances have led to image‐based targeting of the subthalamic nucleus under general anaesthesia (GA), an approach that renders unnecessary microelectrode recording and stimulation tests under local anaesthesia and conscious sedation (CS). We aimed to compare procedures and incidents related to each anaesthetic approach.Methods: Retrospective descriptive comparison of deep brain stimulation under CS versus G. We collected patient and procedure data (e.g., comorbidities, difficult airway criteria, intraoperative monitoring, duration of surgery, hospitalization and motor outcomes) and reviewed intraoperative and postoperative haemodynamic, neurologic and surgery‐related incidents.Results: Seventy‐eight procedures were analysed, 36 in the CS group (47.4%) and 42 in the GA group (52.6%). One‐third of the patients were women, and the median age was 62 years (range, 33–75). In total, 23 patients experienced at least one perioperative incident, 19 (24.4%) in the CS group and 4 (5.1%) in the GA group (p < .001), even though the GA group included higher‐risk patients (p < .05). Fourteen patients (17.9%) presented disorientation/agitation, 12 in the CS group (p < .01). The median duration of the surgery was 5.2 h (range, 3.5–9.2 h) in the CS group, split into two sessions, and 4.6 h (range, 4.1–5.2 h) in the GA group (p < .001). The median (interquartile range [IQR]) hospital stay was also longer in the CS group, at 7.5 days (IQR 6.75–10), compared to 3 days (IQR 3–4) in the GA group (p < .0001). Pre‐ and postoperative movement disorder evaluations for 38 of the 78 patients (49%) showed significantly improved scores after surgery. No differences were found between the two groups either before (p = .41) or after (p = .52) the surgery.Conclusions: Deep brain stimulation under GA was associated with fewer perioperative incidents, shorter surgeries and shorter hospital stays.Editorial Comment: Patients with Parkinson's disease who are refractory to standard drug therapy may benefit from the implantation of deep‐brain stimulating electrodes. In this report, imaging‐guided electrode implantation under general anaesthesia was associated with fewer adverse perioperative events as well as shorter procedure times, compared to implantation guided by intraoperative electrode recording and stimulation under conscious sedation. Since imaging‐ and stimulation‐guided implantation confers equal long‐term benefits to motor function, the results from the current study suggest that general anaesthesia and imaging‐guided implantation represent an overall quality improvement for these patients.

  • Open Access

    Perioperative patient safety recommendations: systematic review of clinical practice guidelines

    by Ismael Martinez-Nicolas, Daniel Arnal-Velasco, Eva Romero-García, Neus Fabregas, Yolanda Sanduende Otero, Irene Leon, Ashish A Bartakke, Javier Silva-Garcia, Anna Rodriguez, Claudia Valli, et al.

    Background: Surgical-related incidents are a common cause of in-hospital adverse events. Surgical patient safety would benefit from evidence-based practices, but a comprehensive collection of patient safety recommendations is still lacking. This study aimed to compile and assess the perioperative patient safety recommendations for adults. Method: A systematic review of clinical practice guidelines was conducted using Medline, Embase, Cochrane, Virtual Health Library Regional Portal, and Trip Database from 2012 to 2022. Eligibility criteria followed a PICAR strategy for patient safety recommendations in the perioperative care continuum. Guidelines were appraised for quality, particularly focusing on the ‘rigour of development’ domain of the AGREE-II tool for those containing strong recommendations. Descriptive analyses were conducted, emphasizing guideline quality, recommendation strength, and the supporting level of evidence. Results: From the 267 guidelines, 4666 perioperative patient safety recommendations were extracted, of which 44.9% (2095) were strongly recommended. Of these, 322 had the highest level of evidence, but only 18 guidelines met high standards in the AGREE-II ‘rigour of development’ domain. A subset of 78 recommendations ranked the highest in the strength of recommendation, level of evidence, and rigour of development of their guidelines. A gap was found within pre-admission and post-discharge care recommendations. Discussion: This review highlights the noteworthy variability in the methodological quality of the guidelines, and a discordance between strength of recommendation and evidence level of the available perioperative patient safety recommendations. These findings provide valuable information for advising policy decisions and promoting best practices to enhance global surgical safety. Registration: PROSPERO (CRD42022347449).


  • Open Access

    Hemodynamic Response, Coughing and Incidence of Cerebrospinal Fluid Leakage on Awakening with an Endotracheal Tube or Laryngeal Mask Airway in Place after Transsphenoidal Pituitary Surgery: A Randomized Clinical Trial

    by Paola Hurtado, Javier Tercero, Marta Garcia-Orellana, Joaquim Enseñat, Luis Reyes, Gemma Cabedo, Jose Rios, Enrique Carrero, Nicolas de Riva, Jaume Fontanals, et al.

    We aimed to compare systemic and cerebral hemodynamics and coughing during emergence after pituitary surgery after endotracheal tube (ETT) extubation or after replacing ETT with a laryngeal mask airway (LMA). Patients were randomized to awaken with an ETT in place or after replacing it with an LMA. We recorded mean arterial pressure (MAP), heart rate, middle cerebral artery (MCA) flow velocity, regional cerebral oxygen saturation (SrO2), cardiac index, plasma norepinephrine, need for vasoactive drugs, coughing during emergence, and postoperative cerebrospinal fluid (CSF) leakage. The primary endpoint was postoperative MAP; secondary endpoints were SrO2 and coughing incidence. Forty-five patients were included. MAP was lower during emergence than at baseline in both groups. There were no significant between-group differences in blood pressure, nor in the number of patients that required antihypertensive drugs during emergence (ETT: 8 patients (34.8%) vs. LMA: 3 patients (14.3%); p = 0.116). MCA flow velocity was higher in the ETT group (e.g., mean (95% CI) at 15 min, 103.2 (96.3–110.1) vs. 89.6 (82.6–96.5) cm·s−1; p = 0.003). SrO2, cardiac index, and norepinephrine levels were similar. Coughing was more frequent in the ETT group (81% vs. 15%; p < 0.001). CSF leakage occurred in three patients (13%) in the ETT group. Placing an LMA before removing an ETT during emergence after pituitary surgery favors a safer cerebral hemodynamic profile and reduces coughing. This strategy may lower the risk for CSF leakage.


  • Bilateral Bispectral Index Monitoring Performance in the Detection of Seizures in Nonanesthetized Epileptic Patients: An Observational Study

    by Neus Fàbregas, Jose F. Eng Valencia, Isabel Belda, Ana Tercero, Adriana Hervias, Santiago Villafuerte, Pedro L. Gambús, Mar Carreño, Ricard Valero

    Background: The aim of this observational study was to determine whether bilateral bispectral index (BIS) monitoring can detect seizures in epileptic patients. Methods: Four-channel frontal BIS monitoring and standard 40-channel electroencephalography monitoring were conducted in epileptic patients undergoing evaluation for epilepsy surgery. The BIS numerical value, signal quality index, electromyography, suppression ratio, and color density spectral array were continuously recorded. In patients with electroencephalography-confirmed seizures, the mean value and trend (slope of linear regression) of bilateral BIS monitor parameters were analyzed from 1 minute before to 1 minute after seizure onset. Results: Of 48 patients included in the study, 21 (43.8%) had at least 1 seizure. BIS numerical value was not able to detect focal or focal to bilateral tonic-clonic seizures. Considering all seizures, the only significant differences between recordings 1 minute before and 1 minute after seizure onset were a decrease in the signal quality index slope from 1 hemisphere (0.039±0.297 vs. −0.085±0.321, respectively; P=0.029) and in the mean signal quality index recorded from both hemispheres (left hemisphere: 65.775±30.599 vs. 61.032±26.285; P=0.016 and right hemisphere: 63.244±31.985 vs. 59.837±27.360; 0.029); these differences were not maintained after Hochberg adjustment for multiple comparisons. In seizures occurring during sleep, there was a change in the electromyography slope of 1 hemisphere before and after seizure onset (−0.141±0.176 vs. 0.162±0.140, respectively; P=0.038). There were variable responses in BIS parameters in the 3 patients who developed focal nonconvulsive seizure clusters. Conclusion: Bilateral BIS monitoring was not able to detect the occurrence of seizures in epileptic patients.


  • List of Contributors

    by Richa Aggarwal, Zulfiqar Ali, Federico Bilotta, Parmod K. Bithal, Matthew T.V. Chan, Mandy H.M. Chu, Melissa Ehlers, Neus Fabregas, Juan Fernández-Candil, Vinod K. Grover, et al.