GRGabriela Flores Rangel

Gabriela Flores Rangel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Gabriela Flores Rangel has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Linear optical response of monolayer Sb 2 Te 3 under uniaxial strain assessed by time-dependent density functional theory

    by O Ruiz-Cigarrillo, R E Balderas-Navarro, B A Culebro-García, D A Zarazúa-Martínez, U Zavala-Morán, O Del Pozo-Zamudio, G Flores-Rangel, Boris Mizaikoff

    Strain engineering enables control over the optical properties of 2D materials, but systematic theoretical studies are computationally demanding. By using time-dependent density functional theory (TDDFT) with optimized hybrid functionals (B3LYP and Gau-PBE) and a long-range corrected kernel (LRC), we study strain-tunable optical properties in monolayer Sb 2 Te 3 . Uniaxial tensile strain along the x -direction induces optical anisotropy between in-plane components and modified near-infrared absorption. Both functionals yield consistent results for 0%–5% strain, validating our predictions. The TDDFT-LRC approach captures the essential physics, as validated through this comparison with more robust reference calculations, while enabling computationally tractable systematic studies for several strain configurations. Strain-induced anisotropy ( ε x x / ε y y ratios of 1.4–3 eV) suggests applications in polarization-sensitive photodetectors and strain sensors. This work presents a computational framework for strain-engineered optical properties in Sb 2 Te 3 and related chalcogenides, helping in the development of next-generation optoelectronic devices where mechanical deformation modulates optical response.

  • Open Access

    Helicobacter pylori Breath Test via Mid-Infrared Sensor Technology

    by Gabriela Flores Rangel, Lorena Diaz de León Martinez, Boris Mizaikoff

    Helicobacter pylori infection has been associated with various gastrointestinal disorders, most notably with the development of gastric cancer. Therefore, it is important to develop technologies for effective, rapid, sensitive, and personalized infection detection. The present study evaluates the utility of mid-infrared (MIR) exhaled breath sensors utilizing substrate-integrated hollow waveguide (iHWG) technology for the precise determination of the isotopic ratio of 13CO2 vs 12CO2 simulating conditions relevant to the detection of the presence of Helicobacter pylori in the upper gastrointestinal tract via exhaled breath analysis. For future integration of such a sensing module, e.g., into a cell phone attachment, optimized light-gas interaction and sufficient sensitivity are essential, as the diagnosis is based on detecting the presence of 13CO2 30 min after administration of 13C-labeled urea via a gel or pill, which is metabolized by H. pylori. By optimizing the light-gas interaction volume via tailoring of the iHWG, it was demonstrated that sufficient sensitivity and accuracy are achieved for detecting small changes in the isotopic composition of exhaled CO2. While it was demonstrated that the combination of conventional Fourier-transform infrared (FTIR) spectroscopy with iHWGs indeed confirms the utility of this noninvasive breath analysis concept, further device miniaturization utilizing quantum cascade lasers is anticipated to achieve the necessary level of integration for personalized home usage.


  • Open Access

    Infrared Spectroscopic Electronic Noses: An Innovative Approach for Exhaled Breath Sensing

    by Johannes Glöckler, Jan Mitrovics, Sara Beeken, Marcis Leja, Tesfalem Welearegay, Lars Österlund, Hossam Haick, Gidi Shani, Corrado Di Natale, Raúl Murillo, et al.

    Gastric cancer remains a leading cause of cancer-related mortality, requiring the urgent development of innovative diagnostic tools for early detection. This study presents an integrated infrared spectroscopic electronic nose system, a novel device that combines infrared (IR) spectroscopy and electronic nose (eNose) concepts for analyzing volatile organic compounds (VOCs) in exhaled breath. This system was calibrated using relevant gas mixtures and then tested during a feasibility study involving 26 gastric cancer patients and 32 healthy controls using chemometric analyses to distinguish between exhaled breath profiles. The obtained results demonstrated that the integration of IR spectroscopy and eNose technologies significantly enhanced the accuracy of VOCs fingerprinting via principal component analysis (PCA) and partial least-squares-discriminant analysis (PLS-DA). Distinct differences between the study groups were revealed with an accuracy of prediction of 0.96 in exhaled breath samples. This combined system offers a high sensitivity and specificity and could potetially facilitate rapid on-site testing rendering the technology an accessible option for early screening particularly in underserved populations.


  • Open Access

    Optical properties of 2D GeTe under strain: A DFT study

    by O. Ruiz-Cigarrillo, G. Flores-Rangel, U. Zavala-Moran, J. Puebla, R. E. Balderas-Navarro, B. Mizaikoff

    Monolayer germanium telluride (GeTe) exhibits tunable electronic and optical properties, making it promising for device applications. Using Density Functional Theory (DFT), we investigate the impact of uniaxial strain, ϵ, on its band structure and dielectric function (DF), ε̃. Tensile strain along the —zigzag direction induces a direct-to-indirect bandgap transition at ϵ = 2%, reducing the gap from 1.80 to 1.62 eV. Compressive strain narrows the gap while maintaining its indirect nature. Strain also induces in-plane anisotropy in the DF and shifts the optical absorption spectrum. We determine a deformation potential (DP) of −6.45 eV for the bandgap under tensile strain and DPs for other above bandgap high-symmetry points. These findings highlight the potential of strain engineering for tuning GeTe’s properties in devices.


  • Open Access

    A Review on Long COVID Screening: Challenges and Perspectives Focusing on Exhaled Breath Gas Sensing

    by Lorena Díaz de León-Martínez, Gabriela Flores-Rangel, Luz E. Alcántara-Quintana, Boris Mizaikoff

    Long COVID (LC) is a great global health concern, affecting individuals recovering from SARS-CoV-2 infection. The persistent and varied symptoms across multiple organs complicate diagnosis and management, and an incomplete understanding of the condition hinders advancements in therapeutics. Current diagnostic methods face challenges related to standardization and completeness. To overcome this, new technologies such as sensor-based electronic noses are being explored for LC assessment, offering a noninvasive screening approach via volatile organic compounds (VOC) sensing in exhaled breath. Although specific LC-associated VOCs have not been fully characterized, insights from COVID-19 research suggest their potential as biomarkers. Additionally, AI-driven chemometrics are promising in identifying and predicting outcomes; despite challenges, AI-driven technologies hold the potential to enhance LC evaluation, providing rapid and accurate diagnostics for improved patient care and outcomes. This review underscores the importance of emerging and sensing technologies and comprehensive diagnostic strategies to address screening and treatment challenges in the face of LC.


  • Open Access

    Recent advances and trends in mid-infrared chem/bio sensors

    by Gabriela Flores Rangel, Lorena Diaz de León Martínez, Lisa Sophie Walter, Boris Mizaikoff


  • Spin relaxation of conduction electrons in coupled quantum wells

    by C. A. Bravo-Velázquez, L.F Lastras-Martínez, O. Ruiz-Cigarrillo, G. Flores-Rangel, L. E Tapia-Rodríguez, K. Biermann, P. V. Santos

    The spin of the conduction-band electrons in a quantum well constitutes a promising two-level system for realizing a quantum bit in the solid state. One of the important parameters in the spin dynamics is their relaxation time. It is desired to develop models and semiconductor structures in order to control it. There are several reported examples of spin lifetime control in quantum wells. Double quantum wells in a semiconductor heterostructure allow the modulation of the relaxation time. By changing the relative thicknesses of the wells in the double quantum well system, the wave function for the lowest-energy level of the conduction band can be distributed symmetrically or asymmetrically with respect to the coupling barrier between the quantum wells to control the Dresselhaus and Rashba components of the spin-orbit coupling and, consequently, the relaxation time. To detect and characterize this effect, circularly polarized photoluminescence was used at low temperatures (19 K). The results reported in the present paper suggest that this coupled double quantum well system enables the design of structures that allows for the control of the relaxation time and the performance of the electron spin as a quantum bit.


  • Optical anisotropies of asymmetric double GaAs (001) quantum wells

    by O. Ruiz-Cigarrillo, L. F. Lastras-Martínez, E. A. Cerda-Méndez, G. Flores-Rangel, C. A. Bravo-Velazquez, R. E. Balderas-Navarro, A. Lastras-Martínez, N. A. Ulloa-Castillo, K. Biermann, P. V. Santos

    In the present work, we were able to identify and characterize a source of in-plane optical anisotropies (IOAs) occurring in asymmetric double quantum wells (DQWs), namely a reduction of the symmetry from D2d to C2v as imposed by asymmetry along the growth direction. We report on reflectance anisotropy spectroscopy (RAS) of double GaAs quantum well structures coupled by a thin (<2 nm) tunneling barrier. Two groups of DQW systems were studied: one where both QWs have the same thickness (symmetric DQW) and another where they have different thicknesses (asymmetric DQW). RAS measures the IOAs arising from the intermixing of the heavy and light holes in the valence band when the symmetry of the DQW system is lowered from D2d to C2v. If the DQW is symmetric, residual IOAs stem from the asymmetry of the QW interfaces, e.g., that associated with Ga segregation into the AlGaAs layer during the epitaxial growth process. In the case of an asymmetric DQW with QWs with different thicknesses, the AlGaAs layers (that are sources of anisotropies) are not distributed symmetrically at both sides of the tunneling barrier. Thus the system loses its inversion symmetry, yielding an increase in the RAS strength. The RAS line shapes were compared with reflectance spectra in order to assess the heavy- and light-hole mixing induced by the symmetry breakdown. The energies of the optical transitions were calculated by numerically solving the one-dimensional Schrödinger equation using a finite-difference method. Our results are useful for interpretation of the transitions occurring in both symmetric and asymmetric DQWs.