Jose E. Tecuapetla-Trejo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jose E. Tecuapetla-Trejo has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Emmanuel Ortega-Robles
Unidad de Trastornos del Movimiento y Sueño, Hospital General Dr. Manuel Gea González, Calzada de Tlalpan 4800, Mexico City 14080, Mexico
1 shared publication - Jessica Cantillo-Negrete
Technological Research Subdirection, Instituto Nacional de Rehabilitación Luis Guillermo Ibarra Ibarra, Mexico City 14389, Mexico
1 shared publication - Oscar Arias-Carrión
División de Neurociencias Clínica, Instituto Nacional de Rehabilitación
1 shared publication - Paul Carrillo-Mora
Clinical Neurosciences Division, National Institute of Rehabilitation “Luis Guillermo Ibarra Ibarra”, Mexico City 14389, Mexico
1 shared publication - Raquel Valdés-Cristerna
Universidad Autónoma Metropolitana Unidad Iztapalapa
1 shared publication - Rubén Isaac Carino-Escobar
Bioelectronics Section, Department of Electrical Engineering, Centro de Investigación y de Estudios Avanzados del Instituto Politécnico Nacional, Mexico City 07360, Mexico
1 shared publication
Latest Publications
- 26 January 2021
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 59 (2) , 449-456
Automatic selection and feature extraction of motor-evoked potentials by transcranial magnetic stimulation in stroke patients
Transcranial magnetic stimulation (TMS) allows the assessment of stroke patients’ cortical excitability and corticospinal tract integrity, which provide information regarding motor function recovery. However, the extraction of features from motor-evoked potentials (MEP) elicited by TMS, such as amplitude and latency, is performed manually, increasing variability due to observer-dependent subjectivity. Therefore, an automatic methodology could improve MEP analysis, especially in stroke, which increases the difficulty of manual MEP measurements due to brain lesions. A methodology based on time-frequency features of stroke patients’ MEPs that allows to automatically select and extract MEP amplitude and latency is proposed. The method was validated using manual measurements, performed by three experts, computed from patients’ affected and unaffected hemispheres. Results showed a coincidence of 58.3 to 80% between automatic and manual MEP selection. There were no significant differences between the amplitudes and latencies computed by two of the experts with those obtained with the automatic method, for most comparisons. The median relative error of amplitudes and latencies computed by the automatic method was 5% and 23%, respectively. Therefore, the proposed method has the potential to reduce processing time and improve the computation of MEP features, by eliminating observer-dependent variability due to the subjectivity of manual measurements. Graphical abstract
- 26 January 2021
- Published by Springer Nature in Medical & Biological Engineering & Computing
- Vol. 59 (2) , 449-456
Automatic selection and feature extraction of motor-evoked potentials by transcranial magnetic stimulation in stroke patients
Transcranial magnetic stimulation (TMS) allows the assessment of stroke patients’ cortical excitability and corticospinal tract integrity, which provide information regarding motor function recovery. However, the extraction of features from motor-evoked potentials (MEP) elicited by TMS, such as amplitude and latency, is performed manually, increasing variability due to observer-dependent subjectivity. Therefore, an automatic methodology could improve MEP analysis, especially in stroke, which increases the difficulty of manual MEP measurements due to brain lesions. A methodology based on time-frequency features of stroke patients’ MEPs that allows to automatically select and extract MEP amplitude and latency is proposed. The method was validated using manual measurements, performed by three experts, computed from patients’ affected and unaffected hemispheres. Results showed a coincidence of 58.3 to 80% between automatic and manual MEP selection. There were no significant differences between the amplitudes and latencies computed by two of the experts with those obtained with the automatic method, for most comparisons. The median relative error of amplitudes and latencies computed by the automatic method was 5% and 23%, respectively. Therefore, the proposed method has the potential to reduce processing time and improve the computation of MEP features, by eliminating observer-dependent variability due to the subjectivity of manual measurements. Graphical abstract