Daniel A. Enderich
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Daniel A. Enderich has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Brad W. Hoff
Air Force Research Laboratory, Kirtland Air Force Base, Albuquerque, NM, USA
3 shared publications Jeremy W. McConaha
AFRL Directed Energy Directorate, Kirtland AFB, USA
3 shared publications- John W. Luginsland
Wright-Patterson AFB
3 shared publications David Revelli
Lovelace Biomedical Research Institute 7 , Albuquerque, New Mexico 87108, USA
2 shared publications- Hammad Irshad
Lovelace Biomedical
2 shared publications Hugh H. Pohle
Air Force Research Laboratory, Directed Energy Directorate 1 , Kirtland AFB, New Mexico 87117, USA
2 shared publications
Latest Publications
- 31 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (4) , 1085-1091
A Novel Compact and Portable Linear Accelerator Electron Beam System
A lightweight, portable 15 MeV electron beam linear accelerator (LINAC) system has been developed for research applications. Our approach uses a commercial, off-the-shelf magnetron to drive an S-band standing-wave accelerator. The magnetron is driven by a Type-E pulse forming network (PFN), the modulator, switched with a thyratron. Within the modulator macropulse, short ( $<$ 100 ns), high-frequency (up to 3500 Hz) electron beam pulses are produced by gating the electron current from a triode electron gun. The entire system is contained within approximately 2 m $^{3}$ , weighs 250 kg, and can be disassembled into two person-portable components, each weighing 50 kg or less.
- 31 March 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 51 (4) , 1085-1091
A Novel Compact and Portable Linear Accelerator Electron Beam System
A lightweight, portable 15 MeV electron beam linear accelerator (LINAC) system has been developed for research applications. Our approach uses a commercial, off-the-shelf magnetron to drive an S-band standing-wave accelerator. The magnetron is driven by a Type-E pulse forming network (PFN), the modulator, switched with a thyratron. Within the modulator macropulse, short ( $<$ 100 ns), high-frequency (up to 3500 Hz) electron beam pulses are produced by gating the electron current from a triode electron gun. The entire system is contained within approximately 2 m $^{3}$ , weighs 250 kg, and can be disassembled into two person-portable components, each weighing 50 kg or less.
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 640-649
Observed Reductions in the Infectivity of Bioaerosols Containing Bovine Coronavirus Under Repetitively Pulsed RF Exposure
Objective: The purpose of the present study is to investigate the inactivation of bioaerosols containing Bovine Coronavirus, BCov, under repetitively pulsed radio frequency (RF) electromagnetic exposure. Methods: These experiments were performed in a waveguide containing a flowing aerosol stream and were limited to a single RF waveform: ∼2 μs square envelope, 5.6 GHz, 4.8 kHz repetition rate. Aerosol streams were exposed to RF electric field amplitudes in the range of 41.9 +/- 6.2 kV/m. Under laminar flow conditions, 75% of the total collected aerosol stream spends 0.85 seconds or less in the RF exposure region. Results: Application of the RF waveform changes mean survival rate of the aerosolized BCov by -0.58 decades (roughly a 74% reduction) and impacted the variance and standard deviation of the experimental results, with the RF exposure data showing an 800% increase in variance and 196% increase in standard deviation over the control results. Experimental results were compared to those from an analytic electromagnetic-heating inactivation model. Conclusion: The comparison indicated the feasibility that the observed reduction in BCov survival rate might be due to a combination of thermal effects and non-thermal electric field effects. Significance: Developing better insight into the mechanisms of inactivation is important for understanding the potential limits of efficacy for this method. Additionally, these results contribute an important baseline for the impact of electromagnetic fields on aerosolized pathogens.
- 17 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 70 (2) , 640-649
Observed Reductions in the Infectivity of Bioaerosols Containing Bovine Coronavirus Under Repetitively Pulsed RF Exposure
Objective: The purpose of the present study is to investigate the inactivation of bioaerosols containing Bovine Coronavirus, BCov, under repetitively pulsed radio frequency (RF) electromagnetic exposure. Methods: These experiments were performed in a waveguide containing a flowing aerosol stream and were limited to a single RF waveform: ∼2 μs square envelope, 5.6 GHz, 4.8 kHz repetition rate. Aerosol streams were exposed to RF electric field amplitudes in the range of 41.9 +/- 6.2 kV/m. Under laminar flow conditions, 75% of the total collected aerosol stream spends 0.85 seconds or less in the RF exposure region. Results: Application of the RF waveform changes mean survival rate of the aerosolized BCov by -0.58 decades (roughly a 74% reduction) and impacted the variance and standard deviation of the experimental results, with the RF exposure data showing an 800% increase in variance and 196% increase in standard deviation over the control results. Experimental results were compared to those from an analytic electromagnetic-heating inactivation model. Conclusion: The comparison indicated the feasibility that the observed reduction in BCov survival rate might be due to a combination of thermal effects and non-thermal electric field effects. Significance: Developing better insight into the mechanisms of inactivation is important for understanding the potential limits of efficacy for this method. Additionally, these results contribute an important baseline for the impact of electromagnetic fields on aerosolized pathogens.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 064712
Nonlinear transmission line-driven apparatus for short-pulse microwave exposure of aerosolized pathogens
A system capable of exposing a flowing aerosol stream to short duration (2–4 ns), high-power RF waveforms is described. The system utilizes a C-band gyromagnetic nonlinear transmission line source having peak power outputs ranging as high as 80 kW at a center frequency of 4.2 GHz. RF electric field magnitudes of up to 280 kV/m ± 17% are achieved within the aerosol flow region of the RF exposure apparatus.
- 1 June 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (6) , 064712
Nonlinear transmission line-driven apparatus for short-pulse microwave exposure of aerosolized pathogens
A system capable of exposing a flowing aerosol stream to short duration (2–4 ns), high-power RF waveforms is described. The system utilizes a C-band gyromagnetic nonlinear transmission line source having peak power outputs ranging as high as 80 kW at a center frequency of 4.2 GHz. RF electric field magnitudes of up to 280 kV/m ± 17% are achieved within the aerosol flow region of the RF exposure apparatus.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 014707
Apparatus for controlled microwave exposure of aerosolized pathogens
A set of three apparatus enabling RF exposure of aerosolized pathogens at four chosen frequencies (2.8 GHz, 4.0 GHz, 5.6 GHz, and 7.5 GHz) has been designed, simulated, fabricated, and tested. Each apparatus was intended to operate at high power without leakage of RF into the local environment and to be compact enough to fit within biocontainment enclosures required for elevated biosafety levels. Predictions for the range of RF electric field exposure, represented by the complex electric field vector magnitude, that an aerosol stream would be expected to encounter while passing through the apparatus are calculated for each of the chosen operating frequencies.
- 1 January 2021
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 92 (1) , 014707
Apparatus for controlled microwave exposure of aerosolized pathogens
A set of three apparatus enabling RF exposure of aerosolized pathogens at four chosen frequencies (2.8 GHz, 4.0 GHz, 5.6 GHz, and 7.5 GHz) has been designed, simulated, fabricated, and tested. Each apparatus was intended to operate at high power without leakage of RF into the local environment and to be compact enough to fit within biocontainment enclosures required for elevated biosafety levels. Predictions for the range of RF electric field exposure, represented by the complex electric field vector magnitude, that an aerosol stream would be expected to encounter while passing through the apparatus are calculated for each of the chosen operating frequencies.