JLJianjun Lai

Jianjun Lai

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jianjun Lai has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Charge Au@Pt NPs combined with 3D STS-Net for adaptive and sensitized radiotherapy of hepatocellular carcinoma: Synergistic enhancement of therapeutic gain across physical and biological dimensions

    by Ji-Gang Piao, Liting Chen, Weiyi Cheng, Lijuan Shen, Wenfan Deng, Yuan Yang, Yicun Li, Wenhao Lin, Jianjun Lai

    The therapeutic gain ratio (TGR) of radiotherapy for hepatocellular carcinoma (HCC) remains limited by two major barriers: insufficient precision in adaptive radiotherapy (ART) on the physical dimension and the lack of effective radiosensitization on the biological dimension. Although advances have been made separately in accurate dose delivery and tumor-sensitizing strategies, no approach has yet integrated both dimensions to achieve a coordinated improvement in TGR, representing a critical gap in current practice. In this study, we propose an integrated physical–biological strategy that combines nanomaterials with artificial intelligence (AI). We first constructed charge-engineered gold–platinum nanoparticles that respond to the acidic tumor microenvironment and enable prolonged, high-contrast computed tomography imaging of HCC. These enhanced images were then used to develop the first Transformer–convolutional neural network hybrid model (3D STS-Net) tailored for this scenario, enabling high-accuracy three-dimensional segmentation of small HCC for image-guided adaptive radiotherapy. In parallel, we systematically evaluated the nanoparticles’ radiosensitizing effects in vitro and in vivo. The nanoparticles provided stable imaging enhancement for up to 120 h and markedly improved tumor–liver contrast. The 3D STS-Net achieved high segmentation accuracy, supporting more precise contouring for HCC ART. Moreover, the nanoparticles significantly increased radiation-induced reactive oxygen species and enhanced tumor control in animal models. Together, these findings demonstrate that the proposed strategy simultaneously strengthens radiotherapy performance in both physical and biological dimensions, leading to a coordinated improvement in TGR. This integrated “nanomaterial–AI” framework offers a systematic and generalizable approach for enhancing radiotherapy effectiveness in HCC.


  • Open Access

    Application of the Monaco-serial biological function for cardiac dose constraints in DIBH-IMRT treatment planning for left-sided breast cancer

    by Haili Hu, Zhou Jueyi, Jiang Hao, Jianjun Lai

    Background: The Serial function in the Monaco treatment planning system is essential for cardiac dose optimization in left breast cancer radiotherapy; however its optimal K-value for deep-inspiration breath-hold intensity-modulated radiotherapy (DIBH-IMRT) has not been established. This study aims to determine the evidence-based K-value configuration for clinical implementation.Methods: 41 left breast cancer patients undergoing DIBH-IMRT were retrospectively analyzed. Plans were stratified by Monaco-Serial K-values: Group A (K=1), B (2≤K ≤ 4), and C (K>4). Dosimetric parameters (heart, LAD, Lung-L) and dose-volume reduction rates (Groups B/C vs A) were compared. Correlations between K-values and DIBH-induced anatomical changes (Lung-L volume increment rate, Lung-L/Heart volume ratio, and Heart-Breast Distance increment) were assessedResults: All plans satisfied target coverage. Group B achieved optimal cardiac protection: mean heart dose (273.9 ± 91.0 cGy), max heart dose (2676.2 ± 1380.7 cGy), and LAD doses (mean: 411.3 cGy; max: 1483.3 ± 736.3 cGy) significantly decreased versus Group A. Lung-L V500cGy in Group B increased marginally but within clinical tolerance. Correlation analysis confirmed that Group B achieved balanced control of mean/maximum heart doses, aligning with the expected effects of anatomical variations induced by the DIBH technique.Conclusions: Adjusting Monaco-Serial K-value to 2≤K ≤ 4 provides optimal dose constraints for the heart and substructures while ensuring target coverage, making it the optimal parameter setting for left breast cancer DIBH-IMRT.

  • Open Access

    Charged Gold Nanoparticles for Target Identification–Alignment and Automatic Segmentation of CT Image-Guided Adaptive Radiotherapy in Small Hepatocellular Carcinoma

    by Jianjun Lai, Zhizeng Luo, Jiping Liu, Haili Hu, Hao Jiang, Pengyuan Liu, Li He, Weiyi Cheng, Weiye Ren, Yajun Wu, et al.

    Because of the challenges posed by anatomical uncertainties and the low resolution of plain computed tomography (CT) scans, implementing adaptive radiotherapy (ART) for small hepatocellular carcinoma (sHCC) using artificial intelligence (AI) faces obstacles in tumor identification-alignment and automatic segmentation. The current study aims to improve sHCC imaging for ART using a gold nanoparticle (Au NP)-based CT contrast agent to enhance AI-driven automated image processing. The synthesized charged Au NPs demonstrated notable in vitro aggregation, low cytotoxicity, and minimal organ toxicity. Over time, an in situ sHCC mouse model was established for in vivo CT imaging at multiple time points. The enhanced CT images processed using 3D U-Net and 3D Trans U-Net AI models demonstrated high geometric and dosimetric accuracy. Therefore, charged Au NPs enable accurate and automatic sHCC segmentation in CT images using classical AI models, potentially addressing the technical challenges related to tumor identification, alignment, and automatic segmentation in CT-guided online ART.


  • Open Access

    Skin marker combined with surface‐guided auto‐positioning for breast DIBH radiotherapy daily initial patient setup: An optimal schedule for both accuracy and efficiency

    by Jianjun Lai, Zhizeng Luo, Lu Jiang, Haili Hu, Chang Gao, Chuanfeng Zhang, Liting Chen, Jing Wu, Zhibing Wu

    Background and purpose: By employing three surface‐guided radiotherapy (SGRT)‐assisted positioning methods, we conducted a prospective study of patients undergoing SGRT‐based deep inspiration breath‐hold (DIBH) radiotherapy using a Sentine/Catalys system. The aim of this study was to optimize the initial positioning workflow of SGRT‐DIBH radiotherapy for breast cancer.Materials and methods: A total of 124 patients were divided into three groups to conduct a prospective comparative study of the setup accuracy and efficiency for the daily initial setup of SGRT‐DIBH breast radiotherapy. Group A was subjected to skin marker plus SGRT verification, Group B underwent SGRT optical feedback plus auto‐positioning, and Group C was subjected to skin marker plus SGRT auto‐positioning. We evaluated setup accuracy and efficiency using cone‐beam computed tomography (CBCT) verification data and the total setup time.Results: In groups A, B, and C, the mean and standard deviation of the translational setup‐error vectors were small, with the highest values of the three directions observed in group A (2.4 ± 1.6, 2.9 ± 1.8, and 2.8 ± 2.1 mm). The rotational vectors in group B (1.8 ± 0.7°, 2.1 ± 0.8°, and 1.8 ± 0.7°) were significantly larger than those in groups A and C, and the Group C setup required the shortest amount of time, at 1.5 ± 0.3 min, while that of Group B took the longest time, at 2.6 ± 0.9 min.Conclusion: SGRT one‐key calibration was found to be more suitable when followed by skin marker/tattoo and in‐room laser positioning, establishing it as an optimal daily initial set‐up protocol for breast DIBH radiotherapy. This modality also proved to be suitable for free‐breathing breast cancer radiotherapy, and its widespread clinical use is recommended.


  • Open Access

    Influence of Anodal tDCS on the Brain Functional Networks and Muscle Synergy of Hand Movements

    by Sijia Chen, Zhizeng Luo, Jianjun Lai

    Background: Transcranial direct current stimulation (tDCS) is a non-invasive technique that has demonstrated potential in modulating cortical neuron excitability. The objective of this paper is to investigate the effects of tDCS on characteristic parameters of brain functional networks and muscle synergy, as well as to explore its potential for enhancing motor performance. Methods: By applying different durations of tDCS on the motor cortex of the brain, the 32-lead electroencephalogram (EEG) of the cerebral cortex and 4-lead electromyography (EMG) signals of the right forearm were collected for 4 typical hand movements which are commonly used in rehabilitation training, including right-hand finger flexion, finger extension, wrist flexion, and wrist extension. Results: The study showed that tDCS can enhance the brain’s electrical activity in the beta band of the C3 node of the cerebral cortex during hand movements. Furthermore, the structure of muscle synergy remains unaltered; however, the associated muscle activity is amplified (p < 0.05). Conclusions: Based on the study results, it can be inferred that tDCS enhances the control strength between the motor area of the cerebral cortex and the muscles during hand movements.


  • Top Cited Papers
    Open Access

    Advances in nanotechnology-based targeted-contrast agents for computed tomography and magnetic resonance

    by Jianjun Lai, Zhizeng Luo, Liting Chen, Zhibing Wu

    X-ray computed tomography (CT) and magnetic resonance (MR) imaging are essential tools in modern medical diagnosis and treatment. However, traditional contrast agents are inadequate in the diagnosis of various health conditions. Consequently, the development of targeted nano-contrast agents has become a crucial area of focus in the development of medical image-enhancing contrast agents. To fully understand the current development of nano-contrast agents, this review provides an overview of the preparation methods and research advancements in CT nano-contrast agents, MR nano-contrast agents, and CT/MR multimodal nano-contrast agents described in previous publications. Due to the physicochemical properties of nanomaterials, such as self-assembly and surface modifiability, these specific nano-contrast agents can greatly improve the targeting of lesions through various preparation methods and clearly highlight the distinction between lesions and normal tissues in both CT and MR. As a result, they have the potential to be used in the early stages of disease to improve diagnostic capacity and level in medical imaging.


  • Open Access

    SGRT‐based DIBH radiotherapy practice for right‐sided breast cancer combined with RNI: A retrospective study on dosimetry and setup accuracy

    by Jianjun Lai, Zhizeng Luo, Haili Hu, Lu Jiang, Jing Wu, Lan Lei, Li Qu, Zhibing Wu

    Background: We retrospectively studied the dosimetry and setup accuracy of deep inspiration breath‐hold (DIBH) radiotherapy in right‐sided breast cancer patients with regional nodal irradiation (RNI) who had completed treatment based on surface‐guided radiotherapy (SGRT) technology by Sentinel/Catalyst system, aiming to clarify the clinical application value and related issues.Methods: Dosimetric indicators of four organs at risk (OARs), namely the heart, right coronary artery (RCA), right lung, and liver, were compared on the premise that the planning target volume met dose‐volume prescription requirements. Meanwhile, the patients were divided into the edge of the xiphoid process (EXP), sternum middle (SM), and left breast wall (LBW) groups according to different positions of respiratory gating primary points. The CBCT setup error data of the three groups were contrasted for the treatment accuracy study, and the effects of different gating window heights on the right lung volume increases were compared among the three groups.Results: Compared with free breath (FB), DIBH reduced the maximum dose of heart and RCA by 739.3 ± 571.2 cGy and 509.8 ± 403.8 cGy, respectively (p < 0.05). The liver changed the most in terms of the mean dose (916.9 ± 318.9 cGy to 281.2 ± 150.3 cGy, p < 0.05). The setup error of the EXP group in the anterior‐posterior (AP) direction was 3.6 ± 4.5 mm, which is the highest among the three groups. The right lung volume increases in the EXP, SM, and LBW groups were 72.3%, 69.9%, and 67.2%, respectively (p = 0.08), and the corresponding breath‐holding heights were 13.5 ± 3.7 mm, 10.3 ± 2.4 mm, and 9.6 ± 2.8 mm, respectively (p < 0.05).Conclusions: SGRT‐based DIBH radiotherapy can better protect the four OARs of right‐sided breast cancer patients with RNI. Different respiratory gating primary points have different setup accuracy and breath‐hold height.


  • Open Access

    SGRT-based DIBH radiotherapy practice for right breast cancer combined with RNI: A retrospective study on dosimetry and treatment accuracy

    by Jianjun Lai, Haili Hu, Lu Jiang, Jing Wu, Lan Lei, Chuanfeng Zhang, Zhao Jing, Li Qu, Zhibing Wu

    Background: This paper studied retrospectively the dosimetry and therapeutic accuracy of deep inspiration breath hold (DIBH) radiotherapy in regional nodal radiation (RNI)-containing right-sided breast cancer patients who had completed treatment based on surface guided radiotherapy (SGRT) technology, hoping to clarify the clinical application value and related issues . Methods: Free breath (FB) and DIBH plans were prepared for31 RNI-containing right breast cancer patients who had completed DIBH radiotherapy based on SGRT technology. Four organs at risk (OARs) including heart, right coronary artery (RCA), right lung and liver were made dosimetriccomparison on the premise that the planning target volume was met dose-volume prescription requirements. Meanwhile, 31 patients were divided into edge of xiphoid process (EXP), sternum middle (SM)and left breast wall (LBW) groups according to different positions of respiratory gating primary points. The CBCT setup error data of the three groups were contrasted for the treatment accuracy study, and the effects of different gating window heights on the lung volume increment of the right side were compared among the three groups. Results: All planning target volume met the dose-volume coverage criteria. Compared with FB, DIBH slumpedthe maximum dose of heart and RCA by 44.3% and 46.7% respectively. The mean dose was went down by 12.5% for right lung. The mean liver dosedecreased the most, with an average reduction rate of 69.4%. The setup error of EXP group in the anterior-posterior (AP) direction was 3.6±4.5mm, significantly higher than the other two groups (2.2±2.6mm, 2.4±3.1mm). The rightlung volume increment in EXP, SM and LBW groups was 72.3%, 69.9 % and 67.2%, respectively(P=0.08), and the corresponding breath-holding heights were 13.5±3.7mm, 10.3±2.4mm, and 9.6±2.8mm, respectively(pConclusions: SGRT-based DIBH can better protect the heart, RCA, ipsilateral lung and liver of right breast cancer patients combined with RNI. Different respiratory gating primary points have different therapeutic accuracy and breath-hold height. On the premise of reasonable respiratory gating primary points, interfractions can be widely applied as it has high repeatability and breath-holding stability to ensure therapeutic accuracy.

  • Open Access

    Design of a Dual-Polarized Omnidirectional Dielectric Resonator Antenna for Capsule Endoscopy System

    by Jianjun Lai, Ji Wang, Kejia Zhao, Hao Jiang, Liting Chen, Zhibing Wu, Jiping Liu

    In this paper, a new dual-polarized (DP) omnidirectional hemisphere dielectric resonator antenna (DRA) for wireless capsule endoscope system (WCE) is proposed. The antenna was excited in its omnidirectional TM018 and TE018 modes to radiate DP wave by a feeding probe and arc microstrip line, respectively. Omnidirectional DP wave can be obtained when the TM018 and TE018 mode are equal in amplitude and phase. The TM018 mode that is equivalent to electric dipole can be obtained by probe feeding. The TE018 mode is excited by four arc microstrip lines feeding. They provide a pair of equivalent magnetic dipoles that are orthogonal to TM018 mode. The DP omnidirectional DRA be fabricated without the need of feed network than circularly polarized. The WCE and the human body equivalent tissue model are adopted in simulation. Water is equivalent to gastric juice during measurement. Communication links between the proposed capsule antenna and the external receiving antenna are measured to demonstrate the advantages the DP brings when capsule antenna is placed in different orientations. The capsule endoscope system with different antennas is placed in water to measure receiving power. The measurement shows that the fabricated antenna exhibits a wide impedance bandwidth for S11 <; -10 dB (2.4-2.48 GHz). The radiation efficiency of the antenna is between 15-18%, and the peak gain is between -13.5 and -15dBi.