Jonas Räber
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jonas Räber has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Angela Botros
Gerontechnology and Rehabilitation Group, ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
1 shared publication - Benjamin Voumard
ARTORG Center for Biomedical Engineering Research, University of Bern, Bern 3010, Switzerland
1 shared publication - Brett Bell
ARTORG Center for Biomedical Engineering Research, University of Bern, Bern 3010, Switzerland
1 shared publication - Carol Hasler
Orthopaedic Department, Children's Hospital, University of Basel, Switzerland
1 shared publication - Daniel Studer
Universitäts-Kinderspital beider Basel
1 shared publication - Lukas Heydrich
Laboratory of Cognitive Neuroscience, Brain Mind Institute, École Polytechnique Fédérale de Lausanne, Lausanne, Switzerland
1 shared publication
Latest Publications
- Open Access
- 11 December 2024
- Published by JMIR Publications Inc. in JMIR Serious Games
- Vol. 12, e52340
Evaluation of a New Mobile Virtual Reality Setup to Alter Pain Perception: Pilot Development and Usability Study in Healthy Participants
Background: Chronic pain presents a significant treatment challenge, often leading to frustration for both patients and therapists due to the limitations of traditional methods. Research has shown that synchronous visuo-tactile stimulation, as used in the rubber hand experiment, can induce a sense of ownership over a fake body part and reduces pain perception when ownership of the fake body part is reported. The effect of the rubber hand experiment can be extended to the full body, for example, during the full-body illusion, using both visuo-tactile and cardiovisual signals. Objective: This study first aimed to evaluate the usability and accuracy of a novel, mobile virtual reality (VR) setup that displays participants’ heartbeats as a flashing silhouette on a virtual avatar, a technique known as the cardiovisual full-body illusion. The second part of the study investigated the effects of synchronous cardiovisual stimulation on pain perception and ownership in 20 healthy participants as compared with asynchronous stimulation (control condition). Methods: The setup comprised a head-mounted display (HMD) and a heart rate measurement device. A smartphone-based HMD (Samsung Galaxy S8+) was selected for its mobility, and heart rates were measured using smartwatches with photoplethysmography (PPG). The accuracy of 2 smartwatch positions was compared with a 5-point electrocardiogram (ECG) standard in terms of their accuracy (number and percent of missed beats). Each participant underwent two 5-minute sessions of synchronous cardiovisual stimulation and two 5-minute sessions of asynchronous cardiovisual stimulation (total of 4 sessions), followed by pain assessments. Usability, symptoms of cybersickness, and ownership of the virtual body were measured using established questionnaires (System Usability Scale, Simulator Sickness Questionnaire, Ownership Questionnaire). Pain perception was assessed using advanced algometric methods (Algopeg and Somedic algometer). Results: Results demonstrated high usability scores (mean 4.42, SD 0.56; out of 5), indicating ease of use and acceptance, with minimal side effects (mean 1.18, SD 0.46; out of a possible 4 points on the Simulator Sickness Questionnaire). The PPG device showed high heart rate measurement precision, which improved with optimized filtering and peak detection algorithms. However, compared with previous work, no significant effects on body ownership and pain perception were observed between the synchronous and asynchronous conditions. These findings are discussed in the context of existing literature on VR interventions for chronic pain. Conclusions: In conclusion, while the new VR setup showed high usability and minimal side effects, it did not significantly affect ownership or pain perception. This highlights the need for further research to refine VR-based interventions for chronic pain management, considering factors like visual realism and perspective.
- 11 December 2024
- Published by JMIR Publications Inc. in JMIR Serious Games
- Vol. 12, e52340
Open AccessEvaluation of a New Mobile Virtual Reality Setup to Alter Pain Perception: Pilot Development and Usability Study in Healthy Participants
Background: Chronic pain presents a significant treatment challenge, often leading to frustration for both patients and therapists due to the limitations of traditional methods. Research has shown that synchronous visuo-tactile stimulation, as used in the rubber hand experiment, can induce a sense of ownership over a fake body part and reduces pain perception when ownership of the fake body part is reported. The effect of the rubber hand experiment can be extended to the full body, for example, during the full-body illusion, using both visuo-tactile and cardiovisual signals. Objective: This study first aimed to evaluate the usability and accuracy of a novel, mobile virtual reality (VR) setup that displays participants’ heartbeats as a flashing silhouette on a virtual avatar, a technique known as the cardiovisual full-body illusion. The second part of the study investigated the effects of synchronous cardiovisual stimulation on pain perception and ownership in 20 healthy participants as compared with asynchronous stimulation (control condition). Methods: The setup comprised a head-mounted display (HMD) and a heart rate measurement device. A smartphone-based HMD (Samsung Galaxy S8+) was selected for its mobility, and heart rates were measured using smartwatches with photoplethysmography (PPG). The accuracy of 2 smartwatch positions was compared with a 5-point electrocardiogram (ECG) standard in terms of their accuracy (number and percent of missed beats). Each participant underwent two 5-minute sessions of synchronous cardiovisual stimulation and two 5-minute sessions of asynchronous cardiovisual stimulation (total of 4 sessions), followed by pain assessments. Usability, symptoms of cybersickness, and ownership of the virtual body were measured using established questionnaires (System Usability Scale, Simulator Sickness Questionnaire, Ownership Questionnaire). Pain perception was assessed using advanced algometric methods (Algopeg and Somedic algometer). Results: Results demonstrated high usability scores (mean 4.42, SD 0.56; out of 5), indicating ease of use and acceptance, with minimal side effects (mean 1.18, SD 0.46; out of a possible 4 points on the Simulator Sickness Questionnaire). The PPG device showed high heart rate measurement precision, which improved with optimized filtering and peak detection algorithms. However, compared with previous work, no significant effects on body ownership and pain perception were observed between the synchronous and asynchronous conditions. These findings are discussed in the context of existing literature on VR interventions for chronic pain. Conclusions: In conclusion, while the new VR setup showed high usability and minimal side effects, it did not significantly affect ownership or pain perception. This highlights the need for further research to refine VR-based interventions for chronic pain management, considering factors like visual realism and perspective.
- Open Access
- 9 February 2021
- Published by ASME International in Journal of Medical Devices
- Vol. 15 (1)
The Spinebot—A Robotic Device to Intraoperatively Quantify Spinal Stiffness
Degenerative spine problems and spinal deformities have high socio-economic impacts. Current surgical treatment is based on bony fusion that can reduce mobility and function. Precise descriptions of the biomechanics of normal, deformed, and degenerated spinal segments under in vivo conditions are needed to develop new approaches that preserve spine function. This study developed a system that intraoperatively measures the three-dimensional segmental stiffness of patient's spine. SpineBot, a parallel kinematic robot, was developed to transmit loads to adjacent vertebrae. A force/torque load cell mounted on the SpineBot measured the moment applied to the spinal segment and calculated segmental stiffnesses. The accuracy of SpineBot was characterized ex vivo by comparing its stiffness measurement of five ovine specimens to measurements obtained with a reference spinal testing system. The SpineBot can apply torques up to 10 N·m along all anatomical axes with a total range of motion of about 11.5 deg ± 0.5 deg in lateral bending, 4.5 deg ± 0.3 deg in flexion/extension, and 2.6 deg ± 0.5 deg in axial rotation. SpineBot's measurements are noisier than the reference system, but the correlation between SpineBot and reference measurements was high (R2 > 0.8). In conclusion, SpineBot's accuracy is comparable to that of current reference systems but can take intraoperative measurements. SpineBot can improve our understanding of spinal biomechanics in patients who have the pathology of interest, and take these measurements in the natural physiological environment, giving us information essential to developing new “nonfusion” products.
- 9 February 2021
- Published by ASME International in Journal of Medical Devices
- Vol. 15 (1)
Open AccessThe Spinebot—A Robotic Device to Intraoperatively Quantify Spinal Stiffness
Degenerative spine problems and spinal deformities have high socio-economic impacts. Current surgical treatment is based on bony fusion that can reduce mobility and function. Precise descriptions of the biomechanics of normal, deformed, and degenerated spinal segments under in vivo conditions are needed to develop new approaches that preserve spine function. This study developed a system that intraoperatively measures the three-dimensional segmental stiffness of patient's spine. SpineBot, a parallel kinematic robot, was developed to transmit loads to adjacent vertebrae. A force/torque load cell mounted on the SpineBot measured the moment applied to the spinal segment and calculated segmental stiffnesses. The accuracy of SpineBot was characterized ex vivo by comparing its stiffness measurement of five ovine specimens to measurements obtained with a reference spinal testing system. The SpineBot can apply torques up to 10 N·m along all anatomical axes with a total range of motion of about 11.5 deg ± 0.5 deg in lateral bending, 4.5 deg ± 0.3 deg in flexion/extension, and 2.6 deg ± 0.5 deg in axial rotation. SpineBot's measurements are noisier than the reference system, but the correlation between SpineBot and reference measurements was high (R2 > 0.8). In conclusion, SpineBot's accuracy is comparable to that of current reference systems but can take intraoperative measurements. SpineBot can improve our understanding of spinal biomechanics in patients who have the pathology of interest, and take these measurements in the natural physiological environment, giving us information essential to developing new “nonfusion” products.