Yu Tian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yu Tian has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Jianye Niu
Hebei Provincial Key Laboratory of Parallel Robot and Mechatronic System, Yanshan University, Qinhuangdao, China
2 shared publications Bo Cheng
Operating Room, Qinhuangdao Hospital of Traditional Chinese Medicine, Qinhuangdao 066004, China
1 shared publicationBowen Su
Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, Qinhuangdao 066004, China
1 shared publication- Bowen Su
Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, Qinhuangdao, China
1 shared publication Hongbo Wang
Parallel Robot and Mechatronic System Laboratory of Hebei Province, Yanshan University, Qinhuangdao 066004, China
1 shared publication- Hongbo Wang
Fudan University
1 shared publication
Latest Publications
- Open Access
- 17 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 164630-164640
A Multimodal AI-Driven System for Preoperative Difficult Airway Assessment
Preoperative assessment of the difficult airway is essential to ensure anesthetic safety. However, traditional assessment methods rely on subjective clinical evaluations and demonstrate limited predictive accuracy. To address this challenge, we propose a multimodal AI-driven airway assessment system. The hardware architecture consists of an integrated camera module, computation module, and display module, while the software is built on a three-stage intelligent framework that comprises image feature extraction, feature-based parameter quantification, and data fusion-based risk prediction. In the feature extraction stage, the framework employs deep learning (DL) models to process input images. Subsequently, the framework automatically measures five critical airway parameters. In the prediction stage, these parameters are fused with personal basic information. Finally, an eXtreme gradient boosting (XGBoost) model processes the fused data to generate a final risk prediction for airway assessment. We evaluated the system performance using a dataset including 1,207 patients undergoing general anesthesia. On an independent test set, the DL models for feature extraction demonstrate high accuracy, with the AI-driven system achieving an area under the curve (AUC) of 0.831. The proposed system offers an objective and accurate solution for preoperative airway assessment, outperforming traditional methods.
- 17 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 13, 164630-164640
Open AccessA Multimodal AI-Driven System for Preoperative Difficult Airway Assessment
Preoperative assessment of the difficult airway is essential to ensure anesthetic safety. However, traditional assessment methods rely on subjective clinical evaluations and demonstrate limited predictive accuracy. To address this challenge, we propose a multimodal AI-driven airway assessment system. The hardware architecture consists of an integrated camera module, computation module, and display module, while the software is built on a three-stage intelligent framework that comprises image feature extraction, feature-based parameter quantification, and data fusion-based risk prediction. In the feature extraction stage, the framework employs deep learning (DL) models to process input images. Subsequently, the framework automatically measures five critical airway parameters. In the prediction stage, these parameters are fused with personal basic information. Finally, an eXtreme gradient boosting (XGBoost) model processes the fused data to generate a final risk prediction for airway assessment. We evaluated the system performance using a dataset including 1,207 patients undergoing general anesthesia. On an independent test set, the DL models for feature extraction demonstrate high accuracy, with the AI-driven system achieving an area under the curve (AUC) of 0.831. The proposed system offers an objective and accurate solution for preoperative airway assessment, outperforming traditional methods.
- Open Access
- 3 August 2021
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2021, 1-12
Structural Design and Preliminary Tests of a Novel Patient Transfer Apparatus for Medical Scenarios
Patient transfer has always been a difficult problem, usually requiring multiple caregivers to work together, which is time consuming and can easily cause secondary injuries to the patient. In addition, with the crisis of COVID-19, the issue of patient transfer is even more critical, as caregivers are at a high risk of infection, causing significant damage to healthcare resources. In this paper, a patient transfer assist system named E-pat-plus (Easy Patient Transfer plus) has been proposed; it can assist caregivers in transferring patients, reduce direct contact between them, and avoid secondary injuries. In the mechanical structure of this apparatus, a novel five-gear assembly module and a synchronous belt pulley set are proposed; they are the key points to the basic functional realization of the device and can reduce the cost of the prototype. Furthermore, a fuzzy (proportion-integration-differentiation) PID-based cross-coupling control strategy is applied to the apparatus to ensure the stability and safety of the operation. Finally, some preliminary experiments, including current experiments and error experiments, are carried out to verify the reliability of the device and lay the foundation for clinical tests.
- 3 August 2021
- Published by Wiley in Journal of Healthcare Engineering
- Vol. 2021, 1-12
Open AccessStructural Design and Preliminary Tests of a Novel Patient Transfer Apparatus for Medical Scenarios
Patient transfer has always been a difficult problem, usually requiring multiple caregivers to work together, which is time consuming and can easily cause secondary injuries to the patient. In addition, with the crisis of COVID-19, the issue of patient transfer is even more critical, as caregivers are at a high risk of infection, causing significant damage to healthcare resources. In this paper, a patient transfer assist system named E-pat-plus (Easy Patient Transfer plus) has been proposed; it can assist caregivers in transferring patients, reduce direct contact between them, and avoid secondary injuries. In the mechanical structure of this apparatus, a novel five-gear assembly module and a synchronous belt pulley set are proposed; they are the key points to the basic functional realization of the device and can reduce the cost of the prototype. Furthermore, a fuzzy (proportion-integration-differentiation) PID-based cross-coupling control strategy is applied to the apparatus to ensure the stability and safety of the operation. Finally, some preliminary experiments, including current experiments and error experiments, are carried out to verify the reliability of the device and lay the foundation for clinical tests.
- Open Access
- 14 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 14306-14318
Design and Evaluation of a Novel Person Transfer Assist System
Person transfer is a major problem for nursing in home and clinical, and this problem is becoming more prominent with the development of aging society and the change of population structure. In this article, a novel person transfer assist system named E-Pat (Easy-Patient Transfer), which can meet the transfer needs of the patient between beds, has been designed and analyzed. The importance and originality of this study are that it explores a theoretical design method for device to enhance patient comfortably when transferred, and put it into practice. The main tasks completed in this article include: (1) a prototype of the device is designed based on the principle of relative static contact point theory. In addition, the corresponding relationship between the human body pressure and the insertion angle is proposed, which provides a theoretical basis for the optimization of the mechanism; (2) based on STM32 (STMicroelectronics 32-bits Microcontroller) chip, the hardware circuit part of the device is designed. According to the transfer environment requirements of the device, the synchronization control algorithm of the device is designed and the experiment is carried out; (3) the performance evaluation of the device is carried out by means of Analytic Hierarchy Process (AHP), through the research of a group of 30 volunteers, the performance of the system has been evaluated accurately, which provides a reference for the industrialization of the prototype. The whole research of this article proves that this kind of person transfer assist system has good performance, it can also reduce the burden of caregivers.
- 14 January 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 14306-14318
Open AccessDesign and Evaluation of a Novel Person Transfer Assist System
Person transfer is a major problem for nursing in home and clinical, and this problem is becoming more prominent with the development of aging society and the change of population structure. In this article, a novel person transfer assist system named E-Pat (Easy-Patient Transfer), which can meet the transfer needs of the patient between beds, has been designed and analyzed. The importance and originality of this study are that it explores a theoretical design method for device to enhance patient comfortably when transferred, and put it into practice. The main tasks completed in this article include: (1) a prototype of the device is designed based on the principle of relative static contact point theory. In addition, the corresponding relationship between the human body pressure and the insertion angle is proposed, which provides a theoretical basis for the optimization of the mechanism; (2) based on STM32 (STMicroelectronics 32-bits Microcontroller) chip, the hardware circuit part of the device is designed. According to the transfer environment requirements of the device, the synchronization control algorithm of the device is designed and the experiment is carried out; (3) the performance evaluation of the device is carried out by means of Analytic Hierarchy Process (AHP), through the research of a group of 30 volunteers, the performance of the system has been evaluated accurately, which provides a reference for the industrialization of the prototype. The whole research of this article proves that this kind of person transfer assist system has good performance, it can also reduce the burden of caregivers.