Katharina Rippel
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Katharina Rippel has a total of 54 co-authors. Here are the top co-authors by number of shared publications:
- Christian Scheurig-Muenkler
Department of Diagnostic and Interventional Radiology, University Hospital of Augsburg, Germany
10 shared publications - Thomas Kröncke
Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany
9 shared publications - Josua A. Decker
Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Augsburg, Germany
7 shared publications - Bertram Jehs
Comprehensive Cancer Center Augsburg (CCCA), Faculty of Medicine, University of Augsburg, 86156 Augsburg, Germany
4 shared publications - Florian Schwarz
Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, 86156 Augsburg, Germany
4 shared publications - Stefanie Bette
Department of Diagnostic and Interventional Radiology, University Hospital Augsburg, Stenglinstr. 2, 86156 Augsburg, Germany
4 shared publications
Latest Publications
- Open Access
- 17 December 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2843
Virtual Monoenergetic Imaging of Thoracoabdominal Computed Tomography Angiography on Photon-Counting Detector Computertomography: Assessment of Image Quality and Leveraging Low-keV Series for Salvaging Suboptimal Contrast Acquisitions
Background: The aim of this study was to assess the possibility of image improvement of ECG-gated, high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta before transaortic valve replacement (TAVR) on a novel dual-source photon-counting detector CT (PCD-CT) in the setting of suboptimal low-contrast attenuation. Methods: Continuously examined patients who underwent an ECG-gated, high-pitch CTA of the aorta on a PCD-CT with a contrast decrease of at least 50% between the ascending aorta and the common femoral arteries (CFA) were included. Patient characteristics were documented. Virtual monoenergetic imaging (VMI) reconstructions with three keV settings were generated. CT values and noise were measured for five vascular segments of the aorta and the CFA. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Two independent board-certified radiologists rated the images with the focus on vascular attenuation, vessel sharpness, and image quality using a 5-point Likert scale. Results: Fifty-five patients (mean age 77.4 ± 8.5 years; 15 women) were included. The SNR was significantly higher at 40 and 45 keV VMI compared to reference 70 keV (p < 0.001 and p = 0.005, respectively). The same was shown for the CNR (p < 0.001 and p = 0.0049, respectively). Subjective image evaluation showed a significant increase in vessel attenuation in the lower keV reconstructions, while the overall image quality decreased only slightly. Furthermore, 50% (8/16) of primarily non-diagnostic scans were considered diagnostic when using low-keV reconstructions (p > 0.05). Conclusions: ECG-gated CTA of the aorta in high-pitch mode on PCD-CT with suboptimal contrast enhancement at the level of the CFA can be salvaged by using low-keV VMI. This implies the possibility of radiation dose reduction by eliminating the need for repeat scans.
- 17 December 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (24) , 2843
Open AccessVirtual Monoenergetic Imaging of Thoracoabdominal Computed Tomography Angiography on Photon-Counting Detector Computertomography: Assessment of Image Quality and Leveraging Low-keV Series for Salvaging Suboptimal Contrast Acquisitions
Background: The aim of this study was to assess the possibility of image improvement of ECG-gated, high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta before transaortic valve replacement (TAVR) on a novel dual-source photon-counting detector CT (PCD-CT) in the setting of suboptimal low-contrast attenuation. Methods: Continuously examined patients who underwent an ECG-gated, high-pitch CTA of the aorta on a PCD-CT with a contrast decrease of at least 50% between the ascending aorta and the common femoral arteries (CFA) were included. Patient characteristics were documented. Virtual monoenergetic imaging (VMI) reconstructions with three keV settings were generated. CT values and noise were measured for five vascular segments of the aorta and the CFA. Signal-to-noise (SNR) and contrast-to-noise ratios (CNR) were calculated. Two independent board-certified radiologists rated the images with the focus on vascular attenuation, vessel sharpness, and image quality using a 5-point Likert scale. Results: Fifty-five patients (mean age 77.4 ± 8.5 years; 15 women) were included. The SNR was significantly higher at 40 and 45 keV VMI compared to reference 70 keV (p < 0.001 and p = 0.005, respectively). The same was shown for the CNR (p < 0.001 and p = 0.0049, respectively). Subjective image evaluation showed a significant increase in vessel attenuation in the lower keV reconstructions, while the overall image quality decreased only slightly. Furthermore, 50% (8/16) of primarily non-diagnostic scans were considered diagnostic when using low-keV reconstructions (p > 0.05). Conclusions: ECG-gated CTA of the aorta in high-pitch mode on PCD-CT with suboptimal contrast enhancement at the level of the CFA can be salvaged by using low-keV VMI. This implies the possibility of radiation dose reduction by eliminating the need for repeat scans.
- Open Access
- 4 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7379
Differences in Management and Outcomes in Atraumatic Splenic Rupture Compared to Traumatic Injury Following Blunt Abdominal Trauma
Background/Objectives: To evaluate the differences in treatment and outcomes between traumatic and atraumatic splenic lacerations. Methods: This retrospective study included all patients with a diagnosis of splenic lacerations confirmed by computed tomography that presented from 01/2010 to 03/2023 at one tertiary hospital. The exclusion criteria included missing image data and death in the first 24 h due to extensive trauma. The etiology of the splenic laceration, demographic characteristics, and clinical parameters were recorded and evaluated as prognostic factors in therapy success and mortality. Subgroup analyses were undertaken according to the etiology of the splenic laceration and the primary treatment. The extent of splenic laceration was assessed by using the American Association for the Surgery of Trauma (AAST) score in its latest revision (2018). Results: Of all 291 enrolled patients (mean age 47 ± 21 years, 204 males), 50 presented with atraumatic splenic lacerations due to different underlying causes. The occurrence of moderate and high-grade laceration differed significantly between the atraumatic and traumatic study group (45/50 [90%] vs. 139/241 [58%], p < 0.001). Accordingly, the number of patients being treated conservatively differed greatly (20/50 [40%] vs. 164/241 [56%]), with a worse clinical success rate for atraumatic lacerations (75% vs. 94.5%). Atraumatic splenic injuries showed a higher conversion rate to surgery (2/20 [10%] vs. 2/164 [1%]). Despite the lower clinical success rate of splenic artery embolization (SAE) in atraumatic injuries (87% vs. 97%), the number of patients needing treatment for primary SAE in AAST 3 injuries was 14.1 in the traumatic population and only 4 in the atraumatic population. Conclusions: Atraumatic splenic injuries should not be treated as traumatic splenic injuries. An early upgrade to SAE or surgery should be considered for moderate splenic injuries, and they should be evaluated by an interdisciplinary team on a case-by-case basis. However, due to the underlying multimorbidity of patients with atraumatic splenic injuries, a higher mortality is to be expected.
- 4 December 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (23) , 7379
Open AccessDifferences in Management and Outcomes in Atraumatic Splenic Rupture Compared to Traumatic Injury Following Blunt Abdominal Trauma
Background/Objectives: To evaluate the differences in treatment and outcomes between traumatic and atraumatic splenic lacerations. Methods: This retrospective study included all patients with a diagnosis of splenic lacerations confirmed by computed tomography that presented from 01/2010 to 03/2023 at one tertiary hospital. The exclusion criteria included missing image data and death in the first 24 h due to extensive trauma. The etiology of the splenic laceration, demographic characteristics, and clinical parameters were recorded and evaluated as prognostic factors in therapy success and mortality. Subgroup analyses were undertaken according to the etiology of the splenic laceration and the primary treatment. The extent of splenic laceration was assessed by using the American Association for the Surgery of Trauma (AAST) score in its latest revision (2018). Results: Of all 291 enrolled patients (mean age 47 ± 21 years, 204 males), 50 presented with atraumatic splenic lacerations due to different underlying causes. The occurrence of moderate and high-grade laceration differed significantly between the atraumatic and traumatic study group (45/50 [90%] vs. 139/241 [58%], p < 0.001). Accordingly, the number of patients being treated conservatively differed greatly (20/50 [40%] vs. 164/241 [56%]), with a worse clinical success rate for atraumatic lacerations (75% vs. 94.5%). Atraumatic splenic injuries showed a higher conversion rate to surgery (2/20 [10%] vs. 2/164 [1%]). Despite the lower clinical success rate of splenic artery embolization (SAE) in atraumatic injuries (87% vs. 97%), the number of patients needing treatment for primary SAE in AAST 3 injuries was 14.1 in the traumatic population and only 4 in the atraumatic population. Conclusions: Atraumatic splenic injuries should not be treated as traumatic splenic injuries. An early upgrade to SAE or surgery should be considered for moderate splenic injuries, and they should be evaluated by an interdisciplinary team on a case-by-case basis. However, due to the underlying multimorbidity of patients with atraumatic splenic injuries, a higher mortality is to be expected.
- Open Access
- 7 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (22) , 2483
Radiomics Feature Stability in True and Virtual Non-Contrast Reconstructions from Cardiac Photon-Counting Detector CT Datasets
Objectives: Virtual non-contrast (VNC) series reconstructed from contrast-enhanced cardiac scans acquired with photon counting detector CT (PCD-CT) systems have the potential to replace true non-contrast (TNC) series. However, a quantitative comparison of the image characteristics of TNC and VNC data is necessary to determine to what extent they are interchangeable. This work quantitatively evaluates the image similarity between VNC and TNC reconstructions by measuring the stability of multi-class radiomics features extracted in intra-patient TNC and VNC reconstructions. Methods: TNC and VNC series of 84 patients were retrospectively collected. For each patient, the myocardium and epicardial adipose tissue (EAT) were semi-automatically segmented in both VNC and TNC reconstructions, and 105 radiomics features were extracted in each mask. Intra-feature correlation scores were computed using the intraclass correlation coefficient (ICC). Stable features were defined with an ICC higher than 0.75. Results: In the myocardium, 41 stable features were identified, and the three with the highest ICC were glrlm_GrayLevelVariance with ICC3 of 0.98 [0.97, 0.99], ngtdm_Strength with ICC3 of 0.97 [0.95, 0.98], firstorder_Variance with ICC3 of 0.96 [0.94, 0.98]. For the epicardial fat, 40 stable features were found, and the three highest ranked are firstorder_Median with ICC3 of 0.96 [0.93, 0.97], firstorder_RootMeanSquared with ICC3 of 0.95 [0.92, 0.97], firstorder_Mean with ICC3 of 0.95 [0.92, 0.97]. A total of 24 features (22.8%; 24/105) showed stability in both anatomical structures. Conclusions: The significant differences in the correlation of radiomics features in VNC and TNC volumes of the myocardium and epicardial fat suggested that the two reconstructions may differ more than initially assumed. This indicates that they may not be interchangeable, and such differences could have clinical implications. Therefore, care should be given when selecting VNC as a substitute for TNC in radiomics research to ensure accurate and reliable analysis. Moreover, the observed variations may impact clinical workflows, where precise tissue characterization is critical for diagnosis and treatment planning.
- 7 November 2024
- Published by MDPI AG in Diagnostics
- Vol. 14 (22) , 2483
Open AccessRadiomics Feature Stability in True and Virtual Non-Contrast Reconstructions from Cardiac Photon-Counting Detector CT Datasets
Objectives: Virtual non-contrast (VNC) series reconstructed from contrast-enhanced cardiac scans acquired with photon counting detector CT (PCD-CT) systems have the potential to replace true non-contrast (TNC) series. However, a quantitative comparison of the image characteristics of TNC and VNC data is necessary to determine to what extent they are interchangeable. This work quantitatively evaluates the image similarity between VNC and TNC reconstructions by measuring the stability of multi-class radiomics features extracted in intra-patient TNC and VNC reconstructions. Methods: TNC and VNC series of 84 patients were retrospectively collected. For each patient, the myocardium and epicardial adipose tissue (EAT) were semi-automatically segmented in both VNC and TNC reconstructions, and 105 radiomics features were extracted in each mask. Intra-feature correlation scores were computed using the intraclass correlation coefficient (ICC). Stable features were defined with an ICC higher than 0.75. Results: In the myocardium, 41 stable features were identified, and the three with the highest ICC were glrlm_GrayLevelVariance with ICC3 of 0.98 [0.97, 0.99], ngtdm_Strength with ICC3 of 0.97 [0.95, 0.98], firstorder_Variance with ICC3 of 0.96 [0.94, 0.98]. For the epicardial fat, 40 stable features were found, and the three highest ranked are firstorder_Median with ICC3 of 0.96 [0.93, 0.97], firstorder_RootMeanSquared with ICC3 of 0.95 [0.92, 0.97], firstorder_Mean with ICC3 of 0.95 [0.92, 0.97]. A total of 24 features (22.8%; 24/105) showed stability in both anatomical structures. Conclusions: The significant differences in the correlation of radiomics features in VNC and TNC volumes of the myocardium and epicardial fat suggested that the two reconstructions may differ more than initially assumed. This indicates that they may not be interchangeable, and such differences could have clinical implications. Therefore, care should be given when selecting VNC as a substitute for TNC in radiomics research to ensure accurate and reliable analysis. Moreover, the observed variations may impact clinical workflows, where precise tissue characterization is critical for diagnosis and treatment planning.
- Open Access
- 21 February 2024
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (6) , 2236-2246
Evaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography
Purpose: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector–CT (PCD-CT) in comparison with an energy-integrating detector–CT (EID-CT), with a special focus on low-contrast attenuation. Methods: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. Results: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. Conclusion: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. Clinical Impact: ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.
- 21 February 2024
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 32 (6) , 2236-2246
Open AccessEvaluation of ECG-Gated, High-Pitch Thoracoabdominal Angiographies With Dual-Source Photon-Counting Detector Computed Tomography
Purpose: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector–CT (PCD-CT) in comparison with an energy-integrating detector–CT (EID-CT), with a special focus on low-contrast attenuation. Methods: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. Results: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. Conclusion: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. Clinical Impact: ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application.
- Open Access
- 4 January 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (4) , 723-732
Virtual non-contrast series of photon-counting detector computed tomography angiography for aortic valve calcium scoring
The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.
- 4 January 2024
- Published by Springer Nature in The International Journal of Cardiovascular Imaging
- Vol. 40 (4) , 723-732
Open AccessVirtual non-contrast series of photon-counting detector computed tomography angiography for aortic valve calcium scoring
The aim of our study was to evaluate two different virtual non-contrast (VNC) algorithms applied to photon counting detector (PCD)-CT data in terms of noise, effectiveness of contrast media subtraction and aortic valve calcium (AVC) scoring compared to reference true non-contrast (TNC)-based results. Consecutive patients underwent TAVR planning examination comprising a TNC scan, followed by a CTA of the heart. VNC series were reconstructed using a conventional (VNCconv) and a calcium-preserving (VNCpc) algorithm. Noise was analyzed by means of the standard deviation of CT-values within the left ventricle. To assess the effectiveness of contrast media removal, heart volumes were segmented and the proportion of their histograms > 130HU was taken. AVC was measured by Agatston and volume score. 41 patients were included. Comparable noise levels to TNC were achieved with all VNC reconstructions. Contrast media was effectively virtually removed (proportions > 130HU from 81% to < 1%). Median calcium scores derived from VNCconv underestimated TNC-based scores (up to 74%). Results with smallest absolute difference to TNC were obtained with VNCpc reconstructions (0.4 mm, Br36, QIR 4), but with persistent significant underestimation (median 29%). Both VNC algorithms showed near-perfect (r²>0.9) correlation with TNC. Thin-slice VNC reconstructions provide equivalent noise levels to standard thick-slice TNC series and effective virtual removal of iodinated contrast. AVC scoring was feasible on both VNC series, showing near-perfect correlation, but with significant underestimation. VNCpc with 0.4 mm slices and Br36 kernel at QIR 4 gave the most comparable results and, with further advances, could be a promising replacement for additional TNC.
- Open Access
- 8 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3402
Image Characteristics of Virtual Non-Contrast Series Derived from Photon-Counting Detector Coronary CT Angiography—Prerequisites for and Feasibility of Calcium Quantification
In photon-counting detector CT (PCD-CT), coronary artery calcium scoring (CACS) can be performed using virtual non-contrast (VNC) series derived from coronary CT angiography (CCTA) datasets. Our study analyzed image characteristics of VNC series in terms of the efficacy of virtual iodine “removal” and image noise to determine whether the prerequisites for calcium quantification were satisfied. We analyzed 38 patients who had undergone non-enhanced CT followed by CCTA on a PCD-CT. VNC reconstructions were performed at different settings and algorithms (conventional VNCConv; PureCalcium VNCPC). Virtual iodine “removal” was investigated by comparing histograms of heart volumes. Noise was assessed within the left ventricular cavity. Calcium was quantified on the true non-contrast (TNC) and all VNC series. The histograms were comparable for TNC and all VNC. Image noise between TNC and all VNC differed slightly but significantly. VNCConv CACS showed a significant underestimation regardless of the reconstruction setting, while VNCPC CACS were comparable to TNC. Correlations between TNC and VNC were excellent, with a higher predictive accuracy for VNCPC. In conclusion, the iodine contrast can be effectively subtracted from CCTA datasets. The remaining VNC series satisfy the requirements for CACS, yielding results with excellent correlation compared to TNC-based CACS and high predicting accuracy.
- 8 November 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (22) , 3402
Open AccessImage Characteristics of Virtual Non-Contrast Series Derived from Photon-Counting Detector Coronary CT Angiography—Prerequisites for and Feasibility of Calcium Quantification
In photon-counting detector CT (PCD-CT), coronary artery calcium scoring (CACS) can be performed using virtual non-contrast (VNC) series derived from coronary CT angiography (CCTA) datasets. Our study analyzed image characteristics of VNC series in terms of the efficacy of virtual iodine “removal” and image noise to determine whether the prerequisites for calcium quantification were satisfied. We analyzed 38 patients who had undergone non-enhanced CT followed by CCTA on a PCD-CT. VNC reconstructions were performed at different settings and algorithms (conventional VNCConv; PureCalcium VNCPC). Virtual iodine “removal” was investigated by comparing histograms of heart volumes. Noise was assessed within the left ventricular cavity. Calcium was quantified on the true non-contrast (TNC) and all VNC series. The histograms were comparable for TNC and all VNC. Image noise between TNC and all VNC differed slightly but significantly. VNCConv CACS showed a significant underestimation regardless of the reconstruction setting, while VNCPC CACS were comparable to TNC. Correlations between TNC and VNC were excellent, with a higher predictive accuracy for VNCPC. In conclusion, the iodine contrast can be effectively subtracted from CCTA datasets. The remaining VNC series satisfy the requirements for CACS, yielding results with excellent correlation compared to TNC-based CACS and high predicting accuracy.
- Open Access
- 1 May 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (3) , 492-499
Technical success and associated economic implications of conventional re-entry devices in subintimal recanalization of femoro-popliteal chronic total occlusions
Re-entry devices contribute to the high success rate of subintimal recanalization of chronic total occlusions (CTO). However, to date, there are no studies comparing the available conventional re-entry devices concerning the impact of their technical success on economic aspects, as these devices differ greatly in their acquisition costs. This prospective observational study intends to contribute to this question. Prior to the start of the prospective study, all previous applications of the Outback® in femoro-popliteal CTO since its introduction to our hospital were analyzed retrospectively (n = 31). From June 2018 until January 2020, all patients with femoro-popliteal CTO treated with clear subintimal recanalization were included (n = 109). In the case of failed spontaneous re-entry, either the OffRoad® (study arm I, n = 20) or the Enteer® catheter (study arm II, n = 20) was used. If assisted re-entry failed, the Outback® device was used as a bailout. Baseline demographic and clinical data, morphologic characteristics, and technical success were documented. Additional per-patient costs due to the use of re-entry devices were analyzed. A retrospective evaluation of all Outback® applications revealed a technical success rate of 97% (30/31). In the prospective study, 63% (68/109) were successfully treated without using re-entry devices. The overall procedural success was 95% (103/109). In study arm I, the OffRoad® achieved a success rate of 45% (9/20), with a subsequent successful application of the Outback® in 80% (8/10) of the failed cases. In study arm II, the Enteer® was successfully employed in 60% (12/20) of cases, and the Outback® was then used successfully in a further 62% (5/8) of cases. Too large a distance between the device and the target lumen was a knockout criterion for all tested devices, leading to a subgroup analysis with the exclusion of three cases, resulting in a success rate of 47% for the OffRoad® and 67% for the Enteer® device. Furthermore, in severe calcification, only the Outback® reliably enabled revascularization. Significant savings of almost €600 were only achieved in study arm II according to German prices. With proper patient selection, a gradual approach with the Enteer® as the primarily used device, with the Outback® used additionally in case of failure, leads to significant savings and can be recommended. In severe calcification, the Outback® should be used as the primary device.
- 1 May 2023
- Published by Galenos Yayinevi in Diagnostic and Interventional Radiology
- Vol. 29 (3) , 492-499
Open AccessTechnical success and associated economic implications of conventional re-entry devices in subintimal recanalization of femoro-popliteal chronic total occlusions
Re-entry devices contribute to the high success rate of subintimal recanalization of chronic total occlusions (CTO). However, to date, there are no studies comparing the available conventional re-entry devices concerning the impact of their technical success on economic aspects, as these devices differ greatly in their acquisition costs. This prospective observational study intends to contribute to this question. Prior to the start of the prospective study, all previous applications of the Outback® in femoro-popliteal CTO since its introduction to our hospital were analyzed retrospectively (n = 31). From June 2018 until January 2020, all patients with femoro-popliteal CTO treated with clear subintimal recanalization were included (n = 109). In the case of failed spontaneous re-entry, either the OffRoad® (study arm I, n = 20) or the Enteer® catheter (study arm II, n = 20) was used. If assisted re-entry failed, the Outback® device was used as a bailout. Baseline demographic and clinical data, morphologic characteristics, and technical success were documented. Additional per-patient costs due to the use of re-entry devices were analyzed. A retrospective evaluation of all Outback® applications revealed a technical success rate of 97% (30/31). In the prospective study, 63% (68/109) were successfully treated without using re-entry devices. The overall procedural success was 95% (103/109). In study arm I, the OffRoad® achieved a success rate of 45% (9/20), with a subsequent successful application of the Outback® in 80% (8/10) of the failed cases. In study arm II, the Enteer® was successfully employed in 60% (12/20) of cases, and the Outback® was then used successfully in a further 62% (5/8) of cases. Too large a distance between the device and the target lumen was a knockout criterion for all tested devices, leading to a subgroup analysis with the exclusion of three cases, resulting in a success rate of 47% for the OffRoad® and 67% for the Enteer® device. Furthermore, in severe calcification, only the Outback® reliably enabled revascularization. Significant savings of almost €600 were only achieved in study arm II according to German prices. With proper patient selection, a gradual approach with the Enteer® as the primarily used device, with the Outback® used additionally in case of failure, leads to significant savings and can be recommended. In severe calcification, the Outback® should be used as the primary device.
- 1 December 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (3) , 650-652
Anemia Detection by Hemoglobin Quantification on Contrast-enhanced Photon-counting CT Data Sets
See also the editorial by Dodd and MacDermott in this issue.
- 1 December 2022
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 305 (3) , 650-652
Anemia Detection by Hemoglobin Quantification on Contrast-enhanced Photon-counting CT Data Sets
See also the editorial by Dodd and MacDermott in this issue.
- 29 January 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 148, 110181
Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
- 29 January 2022
- Published by Elsevier in European Journal of Radiology
- Vol. 148, 110181
Low-dose CT of the abdomen: Initial experience on a novel photon-counting detector CT and comparison with energy-integrating detector CT
- 1 April 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 137, 109578
Non-operative management of blunt splenic trauma: The role of splenic artery embolization depending on the severity of parenchymal injury
- 1 April 2021
- Published by Elsevier in European Journal of Radiology
- Vol. 137, 109578
Non-operative management of blunt splenic trauma: The role of splenic artery embolization depending on the severity of parenchymal injury