HYHazem Yousef

Hazem Yousef

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hazem Yousef has a total of 72 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Crystal optics select weak response of ultrafast crystallography of the Photoactive Yellow Protein

    by Samuel Perrett, Alisia Fadini, Christopher D.M. Hutchison, Hazel Rycroft, Sayantan Bhattacharya, Dmitry Morozov, Srinivasan Muniyappan, Tek Narsingh Malla, Dmitry Khakhulin, Oleksii Turkot, et al.

    Ultrafast crystallography of light-induced processes can directly capture structural differences driven by short-pulse laser illumination. With short pump-probe observation time and short laser pulse durations, the electronic and nuclear dephasing times determine the extent and amplitude of third-order non-linear response in the measurements. While the third-order molecular response is unavoidable in ultrafast crystallography it is currently unknown to what extent non-linear optical excitation processes could contribute to the data. We present a separation of weak and strong response from pump-probe data of photoactive yellow protein crystals collected at a single laser power, based on a method of indexing transformation followed by optical crystallography. We show that this allows precise separation of the heterogeneous photochemical populations with a very high level of data correlation that is intrinsic from the methodology of serial crystallography data collection. This data correlation supports measurable crystallographic electron density differences for the cis-chromophore photoproduct at 3 ps delay comparing weak and strong interactions. While the resulting coordinate refinements are supported by these differences, their sub-Angstrom modifications are inconsequential when the RMS differences of displacements are considered at room temperature. We conclude that these minor crystallographic differences reflect the higher population and therefore signal-to-noise in the strong interaction dataset. Moreover, radical formation driven by excited state absorption, which is the dominating non-linear photoexcitation process under the conditions used, are not detected in high-quality and high-resolution TR-SFX of the photoactive yellow protein.


  • Open Access

    Diamond sensors for hard X-ray energy and position resolving measurements at the European XFEL

    by Tuba Çonka Yıldız, Wolfgang Freund, Jia Liu, Matthias Schreck, Dmitry Khakhulin, Hazem Yousef, Christopher Milne, Jan Grünert

    The diagnostics of X-ray beam properties has a critical importance at the European X-ray Free-Electron Laser facility. Besides existing diagnostic components, utilization of a diamond sensor was proposed to achieve radiation-hard, non-invasive beam position and pulse energy measurements for hard X-rays. In particular, with very hard X-rays, diamond-based sensors become a useful complement to gas-based devices which lose sensitivity due to significantly reduced gas cross-sections. The measurements presented in this work were performed with diamond sensors consisting of an electronic-grade single-crystal chemical-vapor-deposition diamond with position-sensitive resistive electrodes in a duo-lateral configuration. The results show that the diamond sensor delivers pulse-resolved X-ray beam position data at 2.25 MHz with an uncertainty of less than 1% of the beam size. To our knowledge this is the first demonstration of pulse-resolved position measurements at the MHz rate using a transmissive diamond sensor at a free-electron laser facility. It can therefore be a valuable tool for X-ray free-electron lasers, especially for high-repetition-rate machines, enabling applications such as beam-based alignment and intra-pulse-train position feedback.


  • Open Access

    Experimental capabilities for liquid jet samples at sub-MHz rates at the FXE Instrument at European XFEL

    by F. A. Lima, F. Otte, M. Vakili, F. Ardana-Lamas, M. Biednov, F. Dall'ANtonia, P. Frankenberger, W. Gawelda, L. Gelisio, H. Han, et al.

    The Femtosecond X-ray Experiments (FXE) instrument at the European X-ray Free-Electron Laser (EuXFEL) provides an optimized platform for investigations of ultrafast physical, chemical and biological processes. It operates in the energy range 4.7–20 keV accommodating flexible and versatile environments for a wide range of samples using diverse ultrafast X-ray spectroscopic, scattering and diffraction techniques. FXE is particularly suitable for experiments taking advantage of the sub-MHz repetition rates provided by the EuXFEL. In this paper a dedicated setup for studies on ultrafast biological and chemical dynamics in solution phase at sub-MHz rates at FXE is presented. Particular emphasis on the different liquid jet sample delivery options and their performance is given. Our portfolio of high-speed jets compatible with sub-MHz experiments includes cylindrical jets, gas dynamic virtual nozzles and flat jets. The capability to perform multi-color X-ray emission spectroscopy (XES) experiments is illustrated by a set of measurements using the dispersive X-ray spectrometer in von Hamos geometry. Static XES data collected using a multi-crystal scanning Johann-type spectrometer are also presented. A few examples of experimental results on ultrafast time-resolved X-ray emission spectroscopy and wide-angle X-ray scattering at sub-MHz pulse repetition rates are given.


  • Open Access

    The 1-Megapixel pnCCD detector for the Small Quantum Systems Instrument at the European XFEL: system and operation aspects

    by Markus Kuster, Karim Ahmed, Kai-Erik Ballak, Cyril Danilevski, Marko Ekmedžić, Bruno Fernandes, Patrick Gessler, Robert Hartmann, Steffen Hauf, Peter Holl, et al.

    The X-ray free-electron lasers that became available during the last decade, like the European XFEL (EuXFEL), place high demands on their instrumentation. Especially at low photon energies below 1 keV, detectors with high sensitivity, and consequently low noise and high quantum efficiency, are required to enable facility users to fully exploit the scientific potential of the photon source. A 1-Megapixel pnCCD detector with a 1024 × 1024 pixel format has been installed and commissioned for imaging applications at the Nano-Sized Quantum System (NQS) station of the Small Quantum System (SQS) instrument at EuXFEL. The instrument is currently operating in the energy range between 0.5 and 3 keV and the NQS station is designed for investigations of the interaction of intense FEL pulses with clusters, nano-particles and small bio-molecules, by combining photo-ion and photo-electron spectroscopy with coherent diffraction imaging techniques. The core of the imaging detector is a pn-type charge coupled device (pnCCD) with a pixel pitch of 75 µm × 75 µm. Depending on the experimental scenario, the pnCCD enables imaging of single photons thanks to its very low electronic noise of 3 e− and high quantum efficiency. Here an overview on the EuXFEL pnCCD detector and the results from the commissioning and first user operation at the SQS experiment in June 2019 are presented. The detailed descriptions of the detector design and capabilities, its implementation at EuXFEL both mechanically and from the controls side as well as important data correction steps aim to provide useful background for users planning and analyzing experiments at EuXFEL and may serve as a benchmark for comparing and planning future endstations at other FELs.